• Title/Summary/Keyword: Energy recovery device

Search Result 80, Processing Time 0.039 seconds

Stress Behaviors of Superheater Tubes under Load Change Operation in HRSG (배열회수보일러의 부하변동 운전에 따른 과열기 튜브들의 응력거동)

  • Chong, Chae-Hon;Song, Jung-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.33-39
    • /
    • 2008
  • The purpose of this study is not only to evaluate the stress behavior of tubes in superheater in HRSG during the load change operation but also to find root causes of failure from stress behavior. Firstly, temperature during operation was collected to perform stress analysis from actual HRSG. Part load and full load stress analysis which can be represented as the whole load change operations were performed using commercial finite element software. The possibility that can lead to tubes failure is found by stress analysis and its results is compared with metallurgical mircrostructure of failed tube which was taken from actual HRSG.

High-efficiency Agricultural Heater and Smart Control System Utilizing Heat Pipe (히트파이프를 활용한 농업용 고효율난방기 및 스마트 제어시스템)

  • Kim, Eung-Kon;Lim, Chang-Gyoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1151-1158
    • /
    • 2017
  • The Effluent Heat Pipe integral with the heater is a device that recreates unused thermal energy from the plant in winter, and thus reuses unused energy before releasing the exhaust heat. Through the establishment of facility horticulture and glass greenhouses, we identified the problems of our agricultural heaters, and we proposed efficient agricultural efficiency and smart control systems for optimum agricultural efficiency and smart house.

A Study on the Optimal Operating Conditions for an Unreacted Hydrogen Oxidation-Heat Recovery System for the Safety of the Hydrogen Utilization Process (수소 활용공정 안전성 확보를 위한 미반응 수소 산화-열 회수 시스템의 운전 조건 최적화 연구)

  • Younghee Jang;Sung Su Kim
    • Applied Chemistry for Engineering
    • /
    • v.34 no.3
    • /
    • pp.307-312
    • /
    • 2023
  • In this study, a catalytic oxidation-heat recovery system was designed that can remove unreacted with a concentration of about 1% to 6% in the exhaust gas of hydrogen fuel cells and recover heat to ensure safety in the hydrogen economy. The safety system was devised by filling hydrogen oxidation catalysts at room temperature that can remove unreacted hydrogen without any energy source, and an exhaust-heat recovery device was integrated to efficiently recover the heat released from the oxidation reaction. Through CFD analysis, variations in pressure and fluid within the system were shown depending on the filling conditions of the hydrogen oxidation system. In addition, it was found that waste heat could be recovered by optimizing the temperature of the exhaust gas, flow rate, and pressure conditions within the heat recovery system and securing hot water above 40 ℃ by utilizing the exhaust gas oxidation heat source above 300 ℃. Through this study, it was possible to confirm the potential of utilizing hydrogen processes, which are applied in small to medium-sized systems such as hydrogen fuel cells, as a safety system by evaluating them at a pilot scale. Additionally, it could be a safety guideline for responding to unexpected hydrogen safety accidents through further pilot-scale studies.

Heat Exchange Performance of Improved Heat Recovery System (개량형 열회수 시스템의 열교환 성능)

  • Suh, Won-Myung;Yoon, Yong-Cheol;Kwon, Jin-Keun
    • Journal of Bio-Environment Control
    • /
    • v.12 no.3
    • /
    • pp.107-113
    • /
    • 2003
  • This study was carried out to improve the performance of pre-developed heat recovery devices attached to exhaust-gas flue connected to combustion chamber of greenhouse heating system. Four different units were compared in the aspect of heat recovery performance; A-, B-, and C-types are exactly the same with the old ones reported in previous studies. D-type newly developed in this experiment is mainly different with the old ones in its heat exchange area and tube thickness. But airflow direction(U-turn) and pipe arrangement are similar with previous three types. The results are summarized as follows; 1. System performances in the aspect of heat recovery efficiency were estimated as 42.2% for A-type, 40.6% for B-type, 54.4% for C-type, and 69.2% for D-type. 2. There was not significant improvement of heat recovering efficiency between two different airflow directions inside the heat exchange system. But considering current technical conditions, straight air flow pattern has more advantage than hair-pin How pattern (U-turn f1ow). 3. The main factors influencing on heat recovery efficiency were presumably verified to be the total area of heat exchange surface, the thickness of ail-flow pipes, and the convective heat transfer coefficient influenced by airflow velocity under the conditions of allowable pipe durability and safety. 4. Desirable blower capacity for each type of heat recovery units were significantly different to each other. Therefore, the optimum airflow capacity should be determined by considering in economic aspect of electricity required together with the optimum heat recovery performance of given heat recovery systems.

Analysis of Dynamics Characteristics of Water Injection Pump through the 2D Finite Element (2D 유한요소 해석을 통한 물 분사 펌프의 동특성 분석)

  • Lee, Jong-Myeong;Kim, Yong-Hwi;Kim, Jun-Ho;Choi, Hyeon-Cheol;Choi, Byeong Keun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.6
    • /
    • pp.462-469
    • /
    • 2014
  • After drilling operations at the offshore plant, crude oil is producted under high pressure. After that time, oil recovery is reduced, because the pressure of the pipe inside is low during the secondary produce. At that time injection sea water at the pipe inside through water injection pump that the device increase to recovery. A variety of mathematical analysis during the detailed design analysis was not made through the dynamics characteristic at the domestic company. 2D model has reliability of analysis results for the uncomplicated model. Also element and the node the number of significantly less than in the 3D model. So, the temporal part is very effective. In addition, depending on the quality of mesh 3D is a real model and FEM model occurs error. So, user needs a lot of skill. In this paper, a 2D finite element analysis was performed through the dynamics analysis and the study model was validated.

Multisample Extraction system for Solid Phase Extraction of Dissolved Organic Compounds from Sea Water (해수로부터 용존 윤기물의 Solid Phase Extraction을 위한 다수 시료 처리 장치)

  • Cho Ki Woong;Jung Kyungwha;Shin Jongheon;Kim Suk Hyun;Hong Gi-Hoon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.3
    • /
    • pp.34-40
    • /
    • 2000
  • A multisample extraction device was newly designed for efficient extraction of dissolved lipophillic organic compounds from sea water sample. This device allowed extraction of organic compounds from up to 96 sample at a time using 96 multifolder on the principle of solid phase extraction with commercially available octadecyl silane (ODS) cartridges. The recovery yield of the new divice was higher than 90 % while that of conventional liquid-liquid extraction process are only 60 - 70 %. The amount of solvent required for the new device could be reduced to less than 20㎖ per 1ℓ of sample while 1 - 2 ℓ of solvent were used in the conventional liquid-liquid extraction process. The usefulness of this novel method was demonstrated with sea water samples collected from Yellow sea, and the qualitative and quantitative analyses results of the dissolved hydrocarbon showed this method was superior to that of conventional liquid-liquid extraction process in efficiency and reliability.

  • PDF

Investigation of Dual-Spin Turn and Attitude Acquisition of Satellite (위성의 Dual-Spin Turn 방법 분석 및 자세획득)

  • Seo, Hyeon-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.2
    • /
    • pp.36-47
    • /
    • 2006
  • The process of dual spin turn maneuver is introduced for attitude acquisition or recovery from flat spin state of a satellite. The physical principle of momentum transfer during dual spin turn is explained clearly. The case studies of special dual spin turn, in addition to the conventional dual spin turn, that are known as an acceptable cases, are performed to investigate the principle of dual spin turn and to provide a physical insight as well as the solution of dual spin turn. This study is done based on case-study simulation, which includes two-state control scheme composed of open-loop maneuver and energy dissipation device. Furthermore, we investigate the stability for the verification of all control cases after implementing two-stage control. We also provide the simulation scenario of flat spin recovery using dual spin turn method as an example.

An Experimental Study on the Heat Transfer Characteristics of Two-phase closed Thermosyphon (밀폐형 2상 열사이폰의 열전달 특성에 관한 실험적 연구)

  • Cho, Ki-Hyun;Paek, Yee;Chung, Hyung-Kil
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.165-171
    • /
    • 2002
  • The thermosyphon has been used as a heat transmission device in the heat recovery of low level energy and cooling for heat generating equipments. Many studies on the working fluids and wicks have been reported to improve the heat transfer efficiency of the thermosyphon. A low temperature heat pipe with acetone is chosen in the present study to compare the heat transfer characteristics due to pouring amount of working fluid, magnitude of power supplied and tilt angles. The thermosyphon made ⵁ$15.88{\times}0.8t{\times}600mm$ of copper, evaporation section 200mm, insulation section 25mm, condensation 375mm. Heat transfer rate of the thermosyphon increase as magnitude of power supplied increase and observe dry out phenomenon at 5~10% of pouring amount of working fluid. So thermosyphon at the 150kJ/s judged to need 12% or more. Heat transfer rate of the thermosyphon have nothing to do with tilt angles. Dry out phenomenon of the thermo syphon makes it possible that a low temperature thermosyphon may be used to control temperature and heat transfer of a system when the critical quantity of a working fluid is supplied in the thermosyphon.

  • PDF

Effect of flap angle on transom stern flow of a High speed displacement Surface combatant

  • Hemanth Kumar, Y.;Vijayakumar, R.
    • Ocean Systems Engineering
    • /
    • v.10 no.1
    • /
    • pp.1-23
    • /
    • 2020
  • Hydrodynamic Drag of Surface combatants pose significant challenges with regard to fuel efficiency and exhaust emissions. Stern flaps have been used widely as an energy saving device, particularly by the US Navy (Hemanth et al. 2018a, Hemanth Kumar and Vijayakumar 2018b). In the present investigation the effect of flap turning angle on drag reduction is numerically and experimentally studied for a high-speed displacement surface combatant fitted with a stern flap in the Froude number range of 0.17-0.48. Parametric investigations are undertaken for constant chord length & span and varying turning angles of 5° 10° & 15°. Experimental resistance values in towing tank tests were validated with CFD. Investigations revealed that pressure increased as the flow velocity decreased with an increase in flap turning angle which was due to the centrifugal action of the flow caused by the induced concave curvature under the flap. There was no significant change in stern wave height but there was a gradual increase in the stern wave steepness with flap angle. Effective length of the vessel increased by lengthening of transom hollow. In low Froude number regime, flow was not influenced by flap curvature effects and pressure recovery was marginal. In the intermediate and high Froude number regimes pressure recovery increased with the flap turning angle and flow velocity.

A Study on Battery Chargers for the next generation high speed train using the Phase-shift Full-bridge DC/DC Converter (위상전이 풀-브리지 DC/DC 컨버터를 이용한 차세대 고속 전철용 Battery Charger에 관한 연구)

  • Cho, Han-Jin;Kim, Keun-Young;Lee, Sang-Seok;Kim, Tae-Hwan;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.384-387
    • /
    • 2009
  • There is an increasing demand for efficient high power/weight auxiliary power supplies for use on high speed traction application. Many new conversion techniques have been proposed to reduce the voltage and current stress of switching components, and the switching losses in the traditional pulse width modulation (PWM) converter. Especially, the phase shift full bridge zero voltage switching PWM techniques are thought must desirable for many applications because this topology permits all switching devices to operate under zero voltage switching(ZVS) by using circuit parasitic components such as leakage inductance of high frequency transformer and power device junction capacitance. The proposed topology is found to have higher efficiency than conventional soft-switching converter. Also it is easily applicable to phase shift full bridge converter by applying an energy recovery snubber consisted of fast recovery diodes and capacitors.

  • PDF