A Study for the Optimal Operating Conditions of the Gas Turbine Based Combined Cycle Cogeneration Power Plant (가스터빈 복합 열병합 발전의 최적 운전조건에 관한 연구)

  • Cho, Young-Bin;Sohn, Jeong-Lak;Ro, Sung-Tack
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1582-1590
    • /
    • 2004
  • The purpose of this study is to show the existence of optimal operation conditions for minimum fuel consumption of the gas turbine based combined cycle cogeneration power plant. Optimal operational condition means the optimal distribution of the power generated by each gas turbine and the heat generated by each HRSG. Total fuel consumption is calculated by the sum of the fuels for gas turbines and supplementary boiler. Fuel consumption is calculated by numerical methods of energy equations which contain the power generated from gas and steam turbines, the heat generated by HRSG and the heat extracted from high pressure steam turbine.

Development of firing equipment and monitoring system for electric power conversion system for high voltage and large current (고압 대전류용 전력변환 점호장치 및 감시시스템 개발)

  • Lee Joo-Hyun;Lim Ick-Hun;Ryu Ho-Sun
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.481-484
    • /
    • 2006
  • A electric power conversion system in a pumped storage power plant is important equipment for converting electric motor kinetic energy into electric power. A electric power conversion monitoring system consists of high voltage thyristor firing equipment, fault detection module, data gathering module, real time data processing equipment and man machine interface system. This paper describes electric power conversion system overview, the developed SFC monitoring system configuration including system characteristics, and successful application result to San-Cheong pumped storage power plant.

  • PDF

The operation Characteristic of Pilot-scale 2-Stage Coal gasifier (Pilot 규모 2단 형상 가스화기 운전특성 실험)

  • Hong, Jin-Pyo;Chung, Jae-Hwa;Seo, Seok-Bin;Chi, Jun-Hwa;Lee, Seung-Jun;Chung, Suk-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.528-532
    • /
    • 2009
  • Integrated Gasification Combined Cycle (IGCC) power plant converts coal to syngas, which is mainly composed with hydrogen and carbon monoxide, by the gasification process and produces electric power by the gas and steam turbine combined cycle power plant. The purpose of this study is to investigate the influence of gasification process to type and structure of gasifier. For this purpose, the performance characteristics of gasification reaction are analyzed with the operation characteristic of pilot-scale 2-stage coal gasifier. It is found that gasification reaction, floating characteristic of melted slag, particle stick of inside of the gasifier, particle stick and deposit of Syngas cooler are the causes in the different performance characteristics.

  • PDF

The Evaluation of Ductile-Brittle Transition of Fracture Toughness by Material Degradation (재료열화에 따른 파괴인성치의 연성-취성 천이거동 평가)

  • Kim, Sang-Pil;Kim, Hyung-Ick;Seok, Chang-Sung
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.579-584
    • /
    • 2001
  • As the huge energy transfer systems like as nuclear power plant and steam power plant are operated for a long time, mechanical properties are changed and ductile-brittle transition temperature is raised by degradation. So it is required to estimate degradation in order to assess the safety, remaining life, and further operation parameters. The sub-sized specimen test method using surveillance specimen was developed for evaluating the integrity of metallic components. In this study, we would like to present the evaluation technique of the ductile-brittle transition temperature by the sub-sired specimen test. The four classes of the thermally aged 1Cr-1Mo-0.25V specimens were prepared using an artificially accelerated aging method. The tensile test and fracture toughness test were performed. The results of the fracture toughness tests using the sub-sized specimens were compared with the evaluation technique of the ductile-brittle transition temperature.

  • PDF

Numerical Investigation on the Water Discharge Capability of Tidal Power Plant Using CFD (CFD를 사용한 조력발전소 수문의 통수성능 연구)

  • Kim, Gunwoo;Oh, Sangho;Han, Insuk;Ahn, Sukjin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.161-161
    • /
    • 2011
  • The design methodology of the sluice caisson structure is one of important factor that is closely related to the efficiency in tidal power generation. When the sluice caisson is designed to maximize the water discharge capability, it is possible to minimize the number of sluice caissons for attaining the water amount required for achieving the target power generation, which results in reduction of the construction cost for the sluice caisson structure. The discharge capability of sluice caisson is dependent on the geometrical conditions of an apron structure which is placed in both sides of the sluice caisson. In this study, we investigated numerically the variation of water discharge capability of sluice caisson according to the geometrical conditions of apron. Flow fields are simulated with FLOW-3D software using VOF method.

  • PDF

A dynamic simulation study on SCR (Stream Carbon dioxide Reforming) process for pilot plant operation (파일럿 플랜트 최적운전을 위한 SCR공정 동적 모사)

  • Kim, Yong Heon;Bae, Ji Han;Park, Myoung Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.136.2-136.2
    • /
    • 2011
  • A dynamic simulation study on SCR process in GTL process was carried out in order to find optimum operation conditions for pilot plant operation. Optimum operating conditions for SCR synthesis gas process were determined by changing operation variables such as feed temperature and pressure. It was also assumed that physical properties of reaction medium were governed by RKS (Redlich-Kwong-Soave) equation. The effect of temperature and pressure on synthesis gas process $H_2$/CO ratio were mainly examined. Dynamic simulation results were fed back to feed operation condition for optimizing productivity, especially for appropriate condition to FT (Fischer-Tropsch) synthesis unit.

  • PDF

Development of Small Scale Commercial Plant of Rotary Kiln Type for Pyrolysis of Waste Plastic (소규모 로터리 킬른형 폐플라스틱 유화 상용 장치 개발 현황)

  • Lee, Kyong-Hwan;Liu, The Ming
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.142-144
    • /
    • 2008
  • 본 논문은 정부의 연구 지원에 의해 참여기업인 (주)동명알피에프에 설치되고 있는 상용인 반연속식 로터리 킬른형 유화 장치 개발 현황에 대해 논하고자 한다. 본 공정의 특징은 지자체에서 수거된 EPR 종말품을 대상 원료로 하였고, 2기의 병렬로 설치된 킬른형 반응기를 사용하여 주기적 처리에 의해 효율적인 동시에,처리량을 크게 향상시켰다.이 반응 시스템은 용융 및 열분해가 동시에 이루어짐에 따라 공정은 단순하지만 생성 오일의 질이 저하되어 후단에 오일 고급화 공정과 정제 공정이 설치되어 최종 제품의 질을 향상시켰다.이에 대한 전반적인 현황과 공정 기술에 대해 언급되었다.

  • PDF

STATUS OF THE PSHA IN KOREA FOR NUCLEAR POWER PLANT SITES

  • Seo, Jeong-Moon;Noh, Myung-Hyun;Chang, Chun-Joong;Yun, Kwan-Hee
    • Nuclear Engineering and Technology
    • /
    • v.41 no.10
    • /
    • pp.1255-1262
    • /
    • 2009
  • This paper introduces the status of and issues related to the PSHA (Probabilistic Seismic Hazard Analysis) of Korean Nuclear Power Plant sites. PSHA was first introduced to the nuclear industry in the mid-1980s. The Korean PSHA is based on Cornell and accommodates the modem approach for eliciting expertise and statistical treatment. Due to the low seismicity in Korea, large uncertainties exist in the PSHA database including seismic source maps, seismicity parameters of seismic sources, and attenuation formulae. Though research in seismology, geology, and earthquake engineering since the mid-1990s has significantly reduced uncertainties, a considerable amount still exists. Considering the low seismicity of the Korean Peninsula, especially the lack of strong motion data, further reduction will take several decades.

Studies on the heat performance and stability for multi spray type desuperheater of the power plant (발전소용 다중 스프레이형 과열저감기의 열성능 및 안정성에 관한 연구)

  • Cho, Nam-Cheol;Lee, Deok-Gu;Lee, Chae-Moon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.185-190
    • /
    • 2011
  • The important use of the desuperheater(multi spray type) changes the superheated steam into the saturated steam. It is more efficient and suitable for using the process. Also, it is more convenient and stable regarding the process temperature control. In this study, transient and quasi-static analysis were done for the evaluation of structural integrity of the multi spray type desuperheater of the power plant. Computational analysis was used to calculate the thermal stress, and the vibration test was done to evaluate the structural stability. This paper is verified by analysis that water spray nozzle(${\phi}=28mm$) shows the best ability. The results show that structural stability of the desuperheater under the real operating condition was proven.

  • PDF

Chromosome numbers of Euphorbia pekinensis complex in Far East Asia

  • Park, Ki-Ryong;Kurosawa, Takahide;Seo, Min-Gyeong;Lee, Bo-Eun;Ahn, Soo-Kyeong
    • Korean Journal of Plant Taxonomy
    • /
    • v.47 no.4
    • /
    • pp.304-307
    • /
    • 2017
  • We report somatic chromosome numbers for three species belonging to the Euphorbia pekinensis complex distributed in Far East Asia. In E. pekinensis populations distributed in Korea, 2n = 28 and 56 were found, while the Japanese native E. lasiocaula was also found at 2n = 28 and 56 and the Japanese endemic E. sinanensis was found at 2n = 20. Based on the number of chromosomes, E. lasiocaula distributed in Japan supports treatment as a variety of E. pekinensis rather than as a different species, while E. sinanensis should be recognized as a distinct species rather than as a variety of E. pekinensis. In the same populations of E. pekinensis and E. lasiocaula, diploid and tetraploid individuals were found, and the diversity of these chromosome numbers was consistent with the morphological diversity of these populations, suggesting the future evolutionary potential of this species.