• 제목/요약/키워드: Energy input-output analysis

검색결과 247건 처리시간 0.023초

마찰감쇠기가 설치된 건물 응답의 근사해 : 재 고찰 및 새로운 결과 (Approximate solution for a building installed with a friction damper : revisited and new result)

  • 민경원;성지영;이성경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.850-854
    • /
    • 2009
  • Approximate analysis for a building installed with a friction damper is revisited to get insight of its dynamic behavior. Energy balance equation is used to have a closed analytical form solution of dynamic magnification factor (DMF) for the building with combined viscous and friction damping. It is found out that DMF is dependent on friction force ratio and resonance frequency. Linear transfer function from input external force to output building displacement is obtained by simplifying DMF equation. Root mean square of building displacement is derived under earthquake-like random excitation. Finally, design of friction damper is proposed by processing target control ratio, damping ratio factor, and friction force in sequence.

  • PDF

송전선 직렬보상을 이용한 순시전압강하 보상기 (Instantaneous Voltage Sag Corrector Using Series Compensator in Transfer Power Line Generator)

  • 이상훈;민완기;전병석;이대종;홍현문
    • 전기학회논문지P
    • /
    • 제55권1호
    • /
    • pp.21-25
    • /
    • 2006
  • This paper describes the novel control techniques design of VSC(Voltage Sag Corrector) for the purpose of power line quality enhancement. A fast detecting technique of voltage sag is implemented through the detection of instantaneous value on synchronous rotating do-reference frame. The first order digital filter is added in the detection algorithm to protect the insensitive characteristics against the noise. The relationship between the total detection time and cut-off frequency of the filter is described. The size of the capacitor bank used as the energy storage element is designed from the point of view of input/output energy with circuit analysis. Finally, the validity of the proposed scheme is proven through the simulated results.

발전시스템에 물질흐름의 net 개념을 적용한 열경제학 해석 (Thermoeconomics Analysis to apply net concept of material flow to Power System)

  • 김덕진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.962-969
    • /
    • 2000
  • Quality that character of energy is the same at every state in case of equal working fluid and net concept of material flow was applied to thermoeconomics about energy system, and we could naturally explain the suitable degree about this concept, also thermoecomic equations about general power plant was easily deduced. And deduced equations exactly corresponded with principle of thermoeconomics that overall input cost flow rate equal overall output cost flow rate. This equations is applied to gas turbine cogeneration power plant as one example and found the product unit cost. Also this product cost comparison could been naturally explained.

  • PDF

해상풍력터빈 트라이포드 지지구조물의 건전성 모니터링 기법 (Structural Health Monitoring Technique for Tripod Support Structure of Offshore Wind Turbine)

  • 이종원
    • 풍력에너지저널
    • /
    • 제9권4호
    • /
    • pp.16-23
    • /
    • 2018
  • A damage detection method for the tripod support structure of offshore wind turbines is presented for structural health monitoring. A finite element model of a prototype tripod support structure is established and the modal properties are calculated. The degree and location of the damage are estimated based on the neural network technique using the changes of natural frequencies and mode shape due to the damage. The stress distribution occurring in the support structure is obtained by a dynamic analysis for the wind turbine system to select the output data of the neural network. The natural frequencies and mode shapes for 36 possible damage scenarios were used for the input data of the learned neural network for damage assessment. The estimated damages agreed reasonably well with the accurate ones. The presented method could be effectively applied for damage detection and structural health monitoring of various types of support structures of offshore wind turbines.

Implementation of an Interleaved AC/DC Converter with a High Power Factor

  • Lin, Bor-Ren;Lin, Li-An
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.377-386
    • /
    • 2012
  • An interleaved bridgeless buck-boost AC/DC converter is presented in this paper to achieve the characteristics of low conduction loss, a high power factor and low harmonic and ripple currents. There are only two power semiconductors in the line current path instead of the three power semiconductors in a conventional boost AC/DC converter. A buck-boost converter operated in the boundary conduction mode (BCM) is adopted to control the active switches to achieve the following characteristics: no diode reverse recovery problem, zero current switching (ZCS) turn-off of the rectifier diodes, ZCS turn-on of the power switches, and a low DC bus voltage to reduce the voltage stress of the MOSFETs in the second DC/DC converter. Interleaved pulse-width modulation (PWM) is used to control the switches such that the input and output ripple currents are reduced such that the output capacitance can be reduced. The voltage doubler topology is adopted to double the output voltage in order to extend the useable energy of the capacitor when the line voltage is off. The circuit configuration, principle operation, system analysis, and a design example are discussed and presented in detail. Finally, experiments on a 500W prototype are provided to demonstrate the performance of the proposed converter.

Design and Analysis of Universal Power Converter for Hybrid Solar and Thermoelectric Generators

  • Sathiyanathan, M.;Jaganathan, S.;Josephine, R.L.
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.220-233
    • /
    • 2019
  • This work aims to study and analyze the various operating modes of universal power converter which is powered by solar and thermoelectric generators. The proposed converter is operated in a DC-DC (buck or boost mode) and DC-AC (single phase) inverter with high efficiency. DC power sources, such as solar photovoltaic (SPV) panels, thermoelectric generators (TEGs), and Li-ion battery, are selected as input to the proposed converter according to the nominal output voltage available/generated by these sources. The mode of selection and output power regulation are achieved via control of the metal-oxide semiconductor field-effect transistor (MOSFET) switches in the converter through the modified stepped perturb and observe (MSPO) algorithm. The MSPO duty cycle control algorithm effectively converts the unregulated DC power from the SPV/TEG into regulated DC for storing energy in a Li-ion battery or directly driving a DC load. In this work, the proposed power sources and converter are mathematically modelled using the Scilab-Xcos Simulink tool. The hardware prototype is designed for 200 W rating with a dsPIC30F4011 digital controller. The various output parameters, such as voltage ripple, current ripple, switching losses, and converter efficiency, are analyzed, and the proposed converter with a control circuit operates the converter closely at 97% efficiency.

원자력발전소(原子力發電所)가 지역(地域)의 생산(生産), 소득(所得)과 고용(雇傭)에 미치는 효과(效果) 분석(分析) (Regional Production, Income and Employment Impact of Nuclear Power Plant)

  • 신용인;양광남
    • 농업과학연구
    • /
    • 제23권2호
    • /
    • pp.272-284
    • /
    • 1996
  • The present study has quantitatively assessed the regional production, income and employment impact resulting from the construction and operation of nuclear power plant (NPP) upon the domestic local areas by applying the regional input-output analysis model to the case of Wolsong unit-l site. The conclusions regarding the most likely regional economic impacts upon the wolsong site are summarized as follows: 1. The income multipliers are calculated to be 1.563 for the construction phase and 1.500 for the operation phase. These values are relatively high compared with those of other conventional facilities. 2. The level of total employee's wage induced employment associated with the construction phase has been estimated to be 37,000 while that with the operational phase in 1990 to be 5,610. 3. With relation to the aspect of resident welfare it is found that the industrial sector associated with electricity, gas and water supply have remarkably improved with the construction of the NPP. 4. The NPP siting has induced substantial changes in interindustry (input-output) structures of the Wolsong unit-l site which is one of the rural areas where all the domestic NPPs are sited. Such changes are attributed to the industrial recomposition of the region. 5. With the application of other regional economic analysis models and the use of more sufficient regional data, other detailed studies on the economic impact analysis of domestic NPP-related facility sitings are suggested to be carried out further since the influence of NPP sitings is significant to the national economic impact as well as the regional economic impact.

  • PDF

Analysis and Implementation of a New Single Switch, High Voltage Gain DC-DC Converter with a Wide CCM Operation Range and Reduced Components Voltage Stress

  • Honarjoo, Babak;Madani, Seyed M.;Niroomand, Mehdi;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.11-22
    • /
    • 2018
  • This paper presents a single switch, high step-up, non-isolated dc-dc converter suitable for renewable energy applications. The proposed converter is composed of a coupled inductor, a passive clamp circuit, a switched capacitor and voltage lift circuits. The passive clamp recovers the leakage inductance energy of the coupled inductor and limits the voltage spike on the switch. The configuration of the passive clamp and switched capacitor circuit increases the voltage gain. A wide continuous conduction mode (CCM) operation range, a low turn ratio for the coupled inductor, low voltage stress on the switch, switch turn on under almost zero current switching (ZCS), low voltage stress on the diodes, leakage inductance energy recovery, high efficiency and a high voltage gain without a large duty cycle are the benefits of this converter. The steady state operation of the converter in the continuous conduction mode (CCM) and discontinuous conduction mode (DCM) is discussed and analyzed. A 200W prototype converter with a 28V input and a 380V output voltage is implemented and tested to verify the theoretical analysis.

PDFF 기법을 적용한 플라이휠 에너지 저장장치용 PWM 인버터 시스템 제어 (PWM Inverter System Control for Flywheel Energy Storage System using PDFF(Pseudo-Derivative Control with Feedforward Gain) Algorithm)

  • 박종찬;정병환;최해용;최규하
    • 전력전자학회논문지
    • /
    • 제12권3호
    • /
    • pp.267-275
    • /
    • 2007
  • 본 논문은 현재 청정에너지의 개념으로 대두되고 있는 에너지원 가운데 기계적인 에너지로 저장하여 필요 시 꺼내어 사용할 수 있는 플라이휠 에너지 저장장치에 대한 에너지 입, 출력 모델링 및 PWM 인버터 시스템의 해석 및 제어에 관한 논문으로서, 플라이휠 저장장치 특성 및 시스템 모델링에 관해 논의한다. 재질에 따른 플라이휠의 특성과 플라이휠 에너지 저장장치의 속도 특성에 따른 전압과 전류의 변화량을 수식으로 간략화 하여 분석하고, 시뮬레이션을 통하여 플라이휠의 에너지 저장상태를 분석하였다. 또한, 부하측 전원의 이상유무에 관계없이 에너지를 공급할 수 있는 Online UPS로 사용하기 위해 PDFF 제어기법을 이용하여 전압제어 및 전류제어의 이중루프 제어로 구성된 단상 PW방식의 인버터 시스템 제작하였으며, 실험을 통하여 실제로 0.1[p.u], 1[p.u]에서의 제어되는 전압, 전류제어파형 및 THD 특성에 관하여 평가한다.

탄소세 도입의 지역별 및 산업별 영향 분석: 에너지 연소 온실가스 배출량을 중심으로 (The Impacts of Carbon Taxes by Region and Industry in Korea: Focusing on Energy-burning Greenhouse Gas Emissions)

  • 박종욱
    • 자원ㆍ환경경제연구
    • /
    • 제33권1호
    • /
    • pp.87-112
    • /
    • 2024
  • 이 연구는 2019년 지역산업연관표와 지역별 및 산업별 온실가스 배출량을 추정하여 우리나라 온실가스 배출현황 및 탄소중립을 위한 탄소세 부과의 경제적 효과를 지역별 및 산업별로 분석하였다. 분석결과 제조업 중심의 광역자치도에서 온실가스 배출량, 배출계수 및 배출유발계수가 높게 추정되었다. 동일한 산업일지라 하더라도 온실가스 배출계수가 지역에 따라 다른 것으로 나타났는데, 이는 대분류 기준에 따른 상품 분류, 생산기술의 특성, 생산요소 투입구조의 지역별 차이 등에 기인하는 것으로 추정된다. 한편 탄소세가 부과될 경우 온실가스 배출량이 많은 제조업을 중심으로 생산비용이 상승하고 수요 및 생산이 감소할 것으로 예측되었다. 이에 비해 탄소세 부과가 각 지역에 미치는 영향은 지역별로 차이가 상대적으로 크지 않을 것으로 예측되었는데, 이는 지역별로 산업비중이 달라 탄소세 부과가 지역에 미치는 직접적인 영향이 다를지라도 산업연관효과에 의해 그 차이가 완화되기 때문인 것으로 판단된다. 이처럼 탄소세 부과의 영향은 특정 지역에 집중되지 않고 전 지역에 파급될 것으로 예상되는 만큼 향후 탄소중립 이행과정에서 지자체 간의 긴밀한 협조가 필요할 것으로 생각된다.