• 제목/요약/키워드: Energy dispersive X-ray spectroscope

검색결과 17건 처리시간 0.017초

임플랜트 표면 처리 방법에 따른 골조직 반응에 대한 연구 (ON THE BONE TISSUE REACTION TO IMPLANTS WITH DIFFERENT SURFACE TREATMENT METHODS)

  • 김용재;조인호
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.71-84
    • /
    • 2007
  • Statement of problem: Implant surface characteristics plays an important role in clinical success and many studies have been made for improvement of success by changing surface roughness. Purpose: Appropriate increase of surface roughness increases the activity of osteoblast and enhance contact and retention between bone and implant. Material and method- Machined, SLA and RBM surface implants, which are the most commonly used implants were implanted into the tibia of rabbits and after 1 week, 4 weeks, 8 weeks and 12 weeks there were histologic and histomorphometric analysis and study for bone gradient and change of Ca/P ratio using EDS(Energy Dispersive X-ray Spectroscope). Results: Comparison of bone-implant contact showed no significant difference among each implant. In comparison of bone area rates, SLA showed higher value with significant difference at 1 week and 4 weeks, and SLA and RBM at 8 weeks than Machined implant (p<0.05). In analysis of bone constituents with EDS, titanium was specifically detected in new bones and the rates were constant by surface treatment method or period. In case of Ca/P ratio, according to surface treatment method, each group showed significant difference. Lots of old bone fragments produced during implantation remained on the rough surface of RBM implant surface and each group showed histological finding with active synthesis of collagen fibers until 12 weeks. In transmission electronic microscopic examination of sample slice after elapse of twelve weeks, tens nm of borderline (lamina limitans like dense line)was seen to contact the bone, on the interface between bone and implant. Conclusion: SLA and RBM implant with rough surface shows better histomorphometrical result and the trend of prolonged bone formation and maturation in comparison with Machined implant. In addition, implant with rough surface seems to be helpful in early stage bone formation due to remaining of old bone fragments produced in implantation. From the results above, it is considered to be better to use implant with rough surface in implantation.

가스분무 Mg-Zn-Y 합금분말 및 압출재의 특성 (Materials Properties of Gas Atomized and Extruded Mg-Zn-Y Alloys)

  • 채홍준;이진규;배정찬;김택수
    • 한국분말재료학회지
    • /
    • 제13권6호
    • /
    • pp.427-431
    • /
    • 2006
  • Mg-4.3Zn-0.7Y (at%) alloy powders were prepared using an industrial scale gas atomizer, followed by warm extrusion. The powders were almost spherical in shape. The microstructure of atomized powders and those extruded bars was examined using Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscope (EDS) and X-ray Diffractometer (XRD). The grain size of the powders was coarsen as the initial powder size increased. After the extrusion, the grain size became fine due to the severe plastic deformation during the extrusion with the ratio of 10:1. Both the ultimate strength and elongation were enhanced with the decrease of initial particle size.

Effect of Powder Size of Mg-Zn-Y Alloy on the Consolidation

  • Kim, Taek-Soo;Chae, H.J.;Lee, J.K.;Jung, H.G.;Kim, Y.D.;Bae, J.C.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1266-1267
    • /
    • 2006
  • [ $MgZn_{4.3}Y_{0.7}$ ] alloy powders were prepared using an industrial scale gas atomizer, followed by warm extrusion. The powders were almost spherical in shape. The microstructure of powders as atomized and bars as extruded was examined as a function of initial powder size distribution using Scanning Electron Microscope (SEM), Energy Dispersive X-ray Spectroscope (EDS) and X-ray Diffractometer (XRD). The grain sizes were decreased with extruding as well as decreasing the initial powder sizes. Both the ultimate strength and elongation were enhanced as the initial powder sizes were decreased.

  • PDF

정전분무 열분해법에 의한 나노분말의 제조 및 하이드록시 아파타이트 형성능력 평가 (Preparation of electrostatic spray pyrolysis derived nano powder and hydroxyapatite forming ability)

  • 이영환;전경옥;전영선;이지창;황규석
    • 한국결정성장학회지
    • /
    • 제16권6호
    • /
    • pp.244-249
    • /
    • 2006
  • 본 연구에서는 새로운 나노 분말 제조방법 중의 하나인 정전분무 열분해법을 이용하여 칼슘 포스페이트 나노분말을 제조하였다. 정전 분무된 분말은 공기 중에서 $400^{\circ}C$로 30분간 열처리하여 고상화하였다. 결정화된 분말의 하이드록시 아파타이트 형성능력을 평가하기 위하여 Eagle's minimum essential medium solution(MEM)을 사용하였으며, MEM 용액에 침전된 후의 분말의 특성평가를 위하여 X-선 회절 분석법, 전계 방사 주사형 전자 현미경, 에너지 분산 X-선 분광계 및 퓨리에 변환 적외선 분광계를 사용하여 분석을 행하였다. 비정질 구조를 가진 나노 분말은 MEM 용액에 15일 침전 후, 분말의 표면에 유도된 하이드록시 아파타이트 결정을 확인할 수 있었다.

Sn-Xwt%Cu 솔더의 젖음성에 관한 연구 (The wettability of Sn-Xwt%Cu solder)

  • 이종범;노보인;정승부
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2006년 추계학술발표대회 개요집
    • /
    • pp.199-201
    • /
    • 2006
  • The wetting balance test was carried out to compare the wettability of Sn-Xwt%Cu($0{\sim}3$wt%) solders. And, IMCs which were formed at interface between solders and substrates were investigated by using XRD(x-ray diffractometer), SEM(scanning electron microscope) and EDS(energy dispersive spectroscope). The value of ${\gamma}_[fl}$ and(${\gamma}_{fs}-{\gamma}_{ls}$) had a tendency to increase with increasing wetting temperature. The activation energy that was calculated between the bare Cu substrate and flux was increased in the following order Sn-0.7wt%Cu(68.42 kJ/mol);Sn-3.0wt%Cu(72.66 kJ/mol);100wt%Sn solder(94.53 kJ/mol).

  • PDF

상수관로 내부 오염물질의 물리화학적 특성 분석 (A study of physical and chemical properties of internal accumulated material in water mains)

  • 배철호;최두용;이두진;김도환
    • 상하수도학회지
    • /
    • 제28권5호
    • /
    • pp.589-600
    • /
    • 2014
  • Tuberculation and slime accumulated in water mains play an important role in modifying water quality of drinking water. Therefore, in this study, it was investigated that what materials were accumulated, and what components were included in the tuberculation and slime of water mains. The Various tuberculation and slime sample were collected from the 12 water mains to analyze their physical and chemical properties and crystal structure. As a analysis method, VSS(Volatile suspended solid), SEM(scanning electron microscope), EDS(Energy Dispersive X-ray spectroscope), ICP(Inductively Coupled Plasma Mass Spectrometer) and XRD(X-Ray Diffractomete) were used. The results of analysis on the samples, the representative materials were verified such as iron corrosion products, the fine sand particles generated during backwash, fine particles of activated carbon, aluminum used in coagulation process, and manganese included in raw water.

스퍼터링으로 제조된 니켈실리사이드의 미세구조 및 물성 연구 (Microstructure Evolution and Properties of Silicides Prepared by dc-sputtering)

  • 안영숙;송오성;이진우
    • 한국재료학회지
    • /
    • 제10권9호
    • /
    • pp.601-606
    • /
    • 2000
  • Ni mono-silicide는 선폭이 0.15$\mu\textrm{m}$이하에서도 전기저항이 커지는 현상이 없고 Ni와 Si이 1:1로 반응하기 때문에 얇은 실리사이드의 제조가 가능하고 도펀트의 재분포 현상을 감소시킬수 있다. 따라서 0.15$\mu\textrm{m}$급 이하 디바이스에 사용이 기대되는 NiSi의 제조를 위한 Ni 박막의 증착조건 확보와 열처리 조건에 따른 NiSi의 기초 물성조사를 수행하였다. Ni mono-silicide는 sputter의 물리적 증착방법으로 Ni 박박을 증착후 관상로를 상용하여 $150~1000^{\circ}C$ 온도 범위에서 제조하였다. 그후 SPM을 이용하여 각 시편의 표면조도를 측정하였고, 미세구조와 성분분석은 EDS가 장착된 TEM을 사용하여 측정하였다. 각 열처리 온도별 생성상의 전기적 성질은 4 point probe로 측정하였다. 본 연구의 결과, SPM은 비파괴 방법으로 NiSi가 NiSi$_2$로 변태되었는지 확인할 수 있는 효과적인 공정모니터링 방법임을 확인하였고, $800^{\circ}C$이상 공온 열처리에 잔류 Ni의 산화방지를 의해 산소분압의 제어가 $Po_2$=1.5$\pm$10(sup)-11색 이하가 되어야 함을 알 수 있었으며, 전지적 특성실험으로부터 본 연구에서 제조된 박막의 NiSi$\longrightarrow$NiSi$_2$ 상태변온도는 $700^{\circ}C$라고 판단되었다.

  • PDF

Ni Nanoparticles-hollow Carbon Spheres Hybrids for Their Enhanced Room Temperature Hydrogen Storage Performance

  • Kim, Jin-Ho;Han, Kyu-Sung
    • 한국수소및신에너지학회논문집
    • /
    • 제24권6호
    • /
    • pp.550-557
    • /
    • 2013
  • A glucose hydrothermal method is described for preparing hollow carbon spheres (HCS), which have a regular morphology and a high Brunauer-Emmett-Teller surface area of 28.6 m2/g. Scanning electron microscopy shows that they have thin shells and diameter between 2 and 8 ${\mu}m$. The HCSs were modified for the enhanced room temperature hydrogen storage by employing Ni nanoparticles on their surface. The Ni-decorated HCSs were characterized by X-ray diffraction, transmission electron microscopy coupled with an energy dispersive spectroscope, and an inductively coupled plasma spectrometer, indicating that fine and well-distributed Ni nanoparticles can be accomplished on the HCSs. The hydrogen uptake capacity in HCSs with and without Ni loading was evaluated using a high-pressure microbalance at room temperature under a hydrogen pressure upto 9 MPa. As much as 1.23wt.% of hydrogen can be stored when uniformly distributed Ni nanoparticles are formed on the HCSs, while the hydrogen uptake capacity of as-received HCSs was 0.41 wt.%. For Ni nanoparticle-loaded HCSs, hydrogen molecules could be easily dissociated into atomic hydrogen and then chemically adsorbed by the sorbents, leading to an enhanced capacity for storing hydrogen.

급속응고한 고합금 고속도 공구강의 미세조직 특성 (Microstructural Characteristics of Rapidly Solidified Highly Alloyed High Speed Tool Steels)

  • 이인우;김명호
    • 한국주조공학회지
    • /
    • 제15권3호
    • /
    • pp.242-251
    • /
    • 1995
  • Highly alloyed high speed tool steels(ASP steels) were rapidly solidified by melt spinning process, and the microstructures of melt spun tool steel ribbons were examined by optical microscopy and transmission electron microscopy with energy dispersive x-ray spectroscope. The microstructure of melt spun tool steel ribbon was found to be consisted of ${\delta}-ferrite$ cells surrounded by austenite and V-rich MC carbides. The size of ${\delta}-ferrite$ cells and intercellular MC carbides were about $0.4{\mu}m$ or less and 30nm or less, respectively. From the melt spun tool steel ribbons, only the MC type carbide phase was observed, instead of $M_2C$, $M_{23}C_6$ and $M_6C$ carbides which were generally observed in other rapidly solidified high speed steels. Such a change in type of carbide phase formed could be attributed to the increase in alloying content of vanadium and carbon. However, changes in microsturcture of melt spun tool steels with alloying content of cobalt, vanadium and carbon were not observed.

  • PDF

Effects of TiN Coating on the Fatigue Fracture of Dental Implant System with Various Cyclic Loads

  • Jung, Da-Un;Chung, Chae-Heon;Son, Mee-Kyoung;Choe, Han-Cheol
    • 한국표면공학회지
    • /
    • 제48권6호
    • /
    • pp.283-291
    • /
    • 2015
  • The purpose of this study was to investigate effects of TiN coating on the fatigue fracture of dental implant system with various cyclic loads. TiN coated abutment screw, the fixture, and abutment of internal hex type were prepared for fatigue test. The fatigue test was carried out according to ISO 14801:2003(E) using tensile and compression tester with repeated load from 30% to 80% of static fracture force. Morphology and fractured surface was observed by field emission scanning electron microscope(FE-SEM) and energy dispersive X-ray spectroscope(EDS). The fracture cycle drastically decreased as repeated load increased. Especially, in the case of TiN-coated abutment screw, fracture cycle increased compared to non-coated abutment screw. The fatigue crack was propagated fast as repeated load increased. The plastic deformation region decreased, whereas, cleavage fracture region increased as repeated load increased.