• 제목/요약/키워드: Energy detection

검색결과 2,014건 처리시간 0.034초

EDXRF에 의한 용접흄 중의 중금속의 비파괴 정량 (The Non-Destructive Determination of Heavy Metals in Welding Fume by EDXRF)

  • 박승현;정지연;유장진;이나루;유일재;송경석;이용학;한정희;김성진;박정선;정호근
    • 한국산업보건학회지
    • /
    • 제11권3호
    • /
    • pp.229-234
    • /
    • 2001
  • The EDXRF(Energy Dispersive X-ray Fluorescence Spectrometer) technique was applied to the determination of heavy metals in welding fume. The EDXRF method designed in this study was a non-destructive analysis method. Samples were analyzed directly by EDXRF without any pre-treatment such as digestion and dilution. The samples used to evaluate this method were laboratory samples exposed in a chamber connected with a welding fume generator. The samples were first analyzed using a non-destructive EDXRF method. The samples subsequently were analyzed using AAS method to verify accuray of the EDXRF method. The purpose of this study was to evaluate the possibility of the non-destructive analysis of heavy metals in welding fume by EDXRF. The results of this study were as follow: 1.When the samples were collected under the open-face sampling condition, a surface distribution of welding fume particles on sample filters was uniform, which made non-destructive analysis possible. 2. The method was statistically evaluated according to the NIOSH(National Institute for Occupational Safety and Health) and HSE(Health and Safety Executive) method. 3. The overall precision of the EDXRF method Was calculated at 3.45 % for Cr, 2.57 % for Fe and 3.78 % for Mn as relative standard deviation(RSD), respectively. The limits of detection were calculated at $0.46{\mu}g$/sample for Cr, $0.20{\mu}g$/sample for Fe and $1.14{\mu}g$/sample for Mn, respectively. 4. A comparison between the results of Cr, Fe, Mn analyzed by EDXRF and AAS was made in order to assess the accuracy of EDXRF method. The correlation coefficient between the results of EDXRF and AAS was 0.9985 for Cr, 0.9995 for Fe and 0.9982 for Mn, respectively. The overall uncertainty was determined to be ${\pm}12.31%$, 8.64 % and 11.91 % for Cr, Fe and Mn, respectively. In conclusion, this study showed that Cr, Fe, Mn in welding fume were successfully analyzed by the EDXRF without any sample pre-treatment such as digestion and dilution and a good correlation between the results of EDXRF and AAS was obtained. It was thus possible to use the EDXRF technique as an analysis method of working environment samples. The EDXRF method was an efficient method in a non-destructive analysis of heavy metals in welding fume.

  • PDF

가막만 표층퇴적물중 유기물량의 시.공간적 분포 특성 (The Spatio-temporal Distribution of Organic Matter on the Surface Sediment and Its Origin in Gamak Bay, Korea)

  • 노일현;윤양호;김대일;박종식
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제9권1호
    • /
    • pp.1-13
    • /
    • 2006
  • 가막만 표층퇴적물중 유기물량의 시 공간적 분포 특성 및 기원을 파악하고자 2000년 4윌부터 2002년 3월까지월간격으로 현장조사를 실시하였다. 강열감량(IL)은 $4.6{\sim}11.6%(7.1{\pm}1.6%)$, 화학적산소요구량(CODs)은 $2.25{\sim}99.26mgO_2/g-dry(30.98{\pm}19.09mgO_2/g-dry)$, 총 황화물량(AVS)은 $nd{\sim}10.29mgS/g-dry(1.02{\pm}0.58mgS/g-dry)$, 식물색소량은(phaeopigment) $6.84{\sim}116.18{\mu}g/g-dry(23.72{\pm}21.16{\mu}g/g-dry)$, 입자성유기탄소(POC)는 $5.45{\sim}23.24 mgC/g-dty(10.34{\pm}4.40C\;mgC/g-dry)$, 입자성유기질소(PON)는 $0.71{\sim}2.99mgN/g-dry(1.37{\pm}0.58mgN/g-dry)$, 함수율(water content)은 $43.1{\sim}77.6%(55.8{\pm}5.6%)$의 범위를 나타냈으며 펄 함량(mud content)은 모든 정점에서 95% 이상의 값을 나타냈다. 유기물질의 공간적인 분포는 북서 내만역, 만 중앙부와 동쪽해역 그리고 남쪽만 입구역으로 대별되어, 북서 내만역과 남쪽 만 입구역은 만 중앙부와 동쪽해역 및 백야도 인근해역보다 대부분 항목에서 높은 유기물 농도를 나타내었다. 특히 북서 내만역은 과도한 양식활동에 따른 과잉의 유기물 공급, 육상으로부터 생활하수 및 산업폐수 유입, 분지형태의 지형적 특성에 의한 물질의 장기체류로 유기오염이 매우 심각하게 나타났다. 그리고 그로인한 하계 수온약층에 의한 저층의 무산 소 환경이 형성되고 있다. 경시적인 변동양상은 북서 내만역과 남쪽 만 입구역에서 저수온기보다 고수온기에 주로 높은 농도를 보였다. 반면에 만 중앙부와 동쪽해역은 각 항목에서 변동양상의 일정한 규칙성은 보여지지 않으나 황 화물을 제외하면 주로 저수온기에 더 높은 농도를 나타내었다. 황화물 농도는 모든 정점에서 고수온기에 더 높게 나타났으며, 특히 만 중앙부와 동쪽해역은 화학적산소요구량이 $20mgO_2/g-dry$을 넘는 경우 고수온기를 중심으로 일시적인 황화물 증가양상이 나타났다. 가막만 표층퇴적물중 유기물질의 기원은 C/N 비가 평균 8 이하로, 육상기원보다 해양기원 유기물에 의한 것으로 나타났으나, POC/phaeopigment 비로부터 유기물 조성에 있어서 살아있는 식물플랑크톤보다 유기쇄설물이 우점하며, CODs/IL 비로부터 유기쇄설물은 해양자체 순환에 의해 생산되는 것보다 양식활동에서 발생하는 잉여사료와 생물의 배설물 등 인위적 활동에 의한 부분이 높은 것으로 추정되었다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Graded 다층박막거울을 이용한 단색 엑스선 획득 (Acquisition of Monochromatic X-ray using Graded Multilayer Mirror)

  • 유철우;최병정;손현화;권영만;김병욱;김영주;천권수
    • 한국방사선학회논문지
    • /
    • 제9권4호
    • /
    • pp.205-211
    • /
    • 2015
  • 최근 의료영상기술에서 유방암 엑스선 진단기술의 주요 이슈는 정확한 조기암 진단과 환자의 피폭선량의 감소에 있다. 엑스선 영상대비도를 높이고 피폭선량을 줄이는 기술 중 하나로써 다층박막거울을 이용한 단색 엑스선을 획득하는 연구가 선행되어 왔다. 그러나 기존의 Uniform 다층박막거울은 거울면의 일부 반사영역에서만 원하는 파장대역의 단색 엑스선을 얻을 수 있어서 엑스선 영상기술 응용에 한계가 있다. 본 연구에서는 다층박막거울의 전 영역에 걸쳐 동일한 단색엑스선을 얻기 위해 거울에 입사하는 백색 엑스선의 입사각에 상응하는 선형적 기울기의 박막두께를 갖는 Graded 다층박막거울을 설계하였고, 기존 이온빔 스퍼터링 장치에 마스크 제어 장치를 추가 제작하여 $100{\times}100mm^2$ 크기로 제작하였다. 제작된 Graded 다층박막거울은 17.5keV의 단색 엑스선을 획득할 수 있도록 설계하였으며 박막두께주기는 2.88nm~4.62nm(Center 3.87nm)이다. 엑스선 반사율은 60% 이상이며, 단색 엑스선의 FWHM은 1.4keV 이하이고 엑스선 빔 폭은 3mm정도이다. 유방촬영에 적합한 몰리브덴 특성엑스선에 해당하는 17.5keV의 단색 엑스선을 얻음으로써 저선량 고감도 유방암 진단장치 개발에 응용할 수 있을 것으로 기대된다.

장기간 항경련제를 복용하고 있는 소아 간질 환아들의 골밀도 및 골대사 지표들 (Bone Mineral Density and Bone Markers in the Children with Epilepsy Taking on Chronic Anticonvulsants)

  • 이순범;강소영;유지숙
    • Clinical and Experimental Pediatrics
    • /
    • 제48권5호
    • /
    • pp.527-533
    • /
    • 2005
  • 목 적 : 소아 간질 환아에서 장기간 항경련제를 투여시 저신장, 저칼슘혈증, 골밀도 저하가 올 수 있는 것으로 알려져 있다. 저자들은 골밀도 및 골표지자의 연구를 통해 항경련제 투여 환아의 골대사 질환의 위험을 조기 발견할 수 있는지 알아보고자 하였다. 방 법 : 간질로 단국대학교병원 소아과에서 12개월 이상 항경련제 치료를 받고 있는 환자들 중 5-16세의 환아 30명을 대상으로 2003년 7월부터 2004년 2월 사이에 본 연구를 시행하였다. 대상 환아들을 carbamazepine과 valproic acid를 단독 투여군과 2가지 이상의 항경련제를 병합투여한 군으로 나누었고, 요추부 골밀도, 체질량지수, 골연령 및 골표지자들을 측정한 후, 남녀별, 연령별로 분류하여 대조군과 비교하였다. 결 과 : 총 30명이었으며, 검사 당시 평균연령은 $10.4{\pm}3.1$세(5-16세)이었다. Carbamazpine 단독 투여군 10명, valproic acid 단독 투여군 6명, 2가지 이상의 약물을 투여 받은 복합 투여군이 14명이었고 복합 투여군 중에는 뇌성마비 2명, 소두증 2명, 뇌연화증 1명, 선천성심장병 1명이 포함되었다. 각 투여군 간에는 요추 골밀도, 칼슘, 인, 알칼리성 인산화효소, $25(OH)D_3$, 오스테오칼신, 부갑상선호르몬, deoxypyridinoline, 골연령 등의 차이는 없었다. 남녀별, 연령별로 나누었을 때 5세 및 15세 여아에서 -2.5 SDS 미만의 의미있는 골밀도의 감소를 보였으며, 체질량지수는 5 percentile 미만의 현저한 감소를 보이고 있었고, 골 연령 및 신장도 감소되어 있었다. 이러한 감소를 보인 두 명의 환아 중 5세 환아는 심방중격결손증 및 소두증을 가지고 있었으며 15세 여아는 뇌성마비 및 뇌연화증이 있었고 좌하지 골절의 기왕력이 있었으며 두 환아 모두 2가지 항경련제를 4년 이상 투약 받았다. 골밀도는 체질량지수 및 골연령과 통계적으로 의미있는 양의 상관관계를 보였다. 결 론 : 장기간 항경련제를 복용하는 소아환자들에 있어 특히, 신체활동이 제한되어 있거나 다른 만성질환을 동반한 경우에는 골대사에 대한 세심한 주의가 필요하며 주기적으로 키, 몸무게를 측정하여 체질량지수 및 신장의 SDS를 산출하는 것이 골대사에 대한 간단하면서도 중요한 검사가 될 수 있을 것으로 생각된다.

화학발광법에 의한 수용액 중의 선택적 수은(II) 이온 정량 (Selective determination of mercury (II) ion in aqueous solution by chemiluminescence method)

  • 김경민;장택균;김영호;오상협;이상학
    • 분석과학
    • /
    • 제24권4호
    • /
    • pp.243-248
    • /
    • 2011
  • 루미놀 화학발광 시스템(luminol-$H_2O_2$)을 이용하여 수용액 중의 수은(II) 이온을 선택적으로 정량분석 하였다. 루미놀과 과산화수소의 반응에서 촉매작용을 하는 구리(II), 철(III), 크롬(III) 이온 등 다양한 금속이온의 농도를 정량분석한 연구결과가 보고되어 있다. 본 연구에서는 수은(II) 이온이 루미놀과 과산화수소의 반응에서 다른 금속이온과 같이 촉매작용을 하는 것을 관찰하였으며, 수용액 중 수은(II) 이온의 정량분석 조건을 최적화하기 위하여 반응시간, pH등에 따른 영향을 조사하였다. 또한 수은이온이 갖는 1가와 2가 산화수 중에서 수은(I) 이온은 루미놀과 과산화수소의 반응에 있어서 촉매작용을 하지 않았을 뿐만 아니라 반응에 어떠한 영향도 미치지 않았다. 또한 수은(I)과 수은(II) 이온이 공존하는 수용액 중의 수은(II) 이온의 분석과정에서 수은(I) 이온의 방해 효과는 관찰되지 않았다. 이를 바탕으로 하여 루미놀 화학발광 시스템을 이용하여 수용액 중의 수은(II) 이온만 선택적으로 분석하는 것이 가능하다는 결과와 함께 화학발광분석법과 ICP분석법으로부터 얻은 실험결과를 비교하여 수용액 내에 존재하는 수은 이온의 산화수별 농도를 확인할 수 있다. 루미놀 화학발광 시스템의 최적 분석조건 하에서, 수용액 중의 선택적 수은(II) 이온의 정량분석을 위해 얻은 검정곡선에서 직선성이 성립하는 농도범위는 $1.25{\times}10^{-5}{\sim}2.50{\times}10^{-3}M$이며, 이때 상관계수는 0.991이고, 검출한계는 $1.25{\times}10^{-7}M$이었다.

하이라인 갈색 산란계의 일령별 혈액 화학치 변화 분석 (Analysis of the Age-Dependent Change in the Blood Chemical Values from Hyline Brown Layer Chickens under Field Condition)

  • 손영호;차세연;박종범;박영명;류경선;장형관
    • 한국가금학회지
    • /
    • 제34권2호
    • /
    • pp.91-97
    • /
    • 2007
  • 산란계에서 일령에 따른 생리적인 변화를 구명하기 위하여 혈액의 성상이 분석되었다. 13개의 산란계 농장에서 수집된 48계군에서 1, 11, 21, 50, 80, 120, 180, 240, 300, 400, 500일령에 채혈하였으며, 포도당, 지질, 단백질, 효소, 전해질 등 17종의 혈액을 구성하는 물질이 혈액 자동분석기에 의하여 분석되었다. 혈청 내 포도당의 함량은 사료 내 탄수화물의 함량이나 에너지가와 상관없이 부화시에 가장 높고 서서히 감소되는 경향을 보였지만, 총 단백질, 알부민, 그리고 글로불린의 함량은 사료 내 단백질 함량이 감소되었을지라도 일령이 경과함에 따라 증가하였다. 혈청 내 지방 함량은 사료에 포함된 지방의 함량에 관계없이 지방의 종류에 따라 변화가 상이하였다. 콜레스테롤은 부화 시 가장 높고 120일령까지는 낮은 상태를 유지하다가 180일령 이후에 증가하였으나, HDL-콜레스테롤은 부화 시 가장 높고 이후에 서서히 감소하다가 180 일령 이후에는 급격히 감소하였다. 트리글리세라이드는 부화시에 가장 낮고 120일령까지는 부화시보다 약간 높은 수준을 유지하다가 180일령 이후에 10배 이상 급격히 증가하는 경향을 보였다. 효소의 수치는 AST, ALT, 그리고 GGT는 비교적 일정하게 유지되었으나, 아밀라제는 부화 후 일령이 경과함에 따라 서서히 감소되었다. 또한 인, 나트륨, 칼륨, 그리고 염소의 함량은 대체로 일정하게 유지되었으나, 칼슘의 함량은 180일령을 전후로 2배 이상 상승하여 유지되었다. 혈청내 노폐물인 요소와 요산은 부화시 가장 높고 급격히 감소한 후에 요소는 일정하게 유지되었으나, 요산은 120일령부터 증가하여 180일령 이후에는 일정한 상태를 유지하였다. 이 실험의 결과로 혈청 내 칼슘 함량의 변화와 사료 내 칼슘 함량의 변화 간의 상관 관계에 대한 구명이 추후에 필요하지만 혈청 내 존재하는 여러 종류의 혈청 성분은 대부분이 사료의 성상과 관계없이 일령이 경과함에 따라서 대사 변화에 의해 함량이 변화되는 경향을 보였다.

원격탐사의 지하수 수자원 적용 사례 고찰 (Review of Remote Sensing Studies on Groundwater Resources)

  • 이정호
    • 대한원격탐사학회지
    • /
    • 제33권5_3호
    • /
    • pp.855-866
    • /
    • 2017
  • 본 논문에서는 지하수 수자원의 부존 및 대수층의 역학적 변화를 원격 탐사 방법으로 해석한 연구사례를 고찰하였다. 지질 분포, 지표수 및 지형 고도차, 식생 분포, 강수량과 증발산량의 변화를 측정하는 기법에는 항공 자력 탐사 분석에 의한 지질 선구조 해석, DEM, 엽면적지수, 정규 식생 지수 및 지표면 에너지 밸런스 계산 등이 있으며, 모두 원격 탐사로 수득된 자료에 기반하며, 광역적 차원에서의 지하수 수자원 부존 여부를 정성적으로 분석할 수 있다. 위성 센서 자료의 직접 이용을 통한 지하수 부존 및 동력학의 정량적 해석은 현재까지 GRACE와 InSAR가 가장 각광받는 탐사 방법임을 알 수 있었다. GRACE는 미소 중력장 변화를 지구 표면 및 내부 수체의 질량 변화로 전환할 수 있는 센서 보유 위성으로서, 센서 자료의 보정이 필요 없고, 지하수 부존 정량 분석을 위한 보조 자료를 모두 다른 위성 센서 자료에서 수득할 수 있으며, 자료처리 알고리즘의 지속적인 개선이 진행되고 있어서, 전세계적으로 수많은 연구가 수행되었다. 그러나, 위성센서의 검출 한계로 인해 협소한 지역에서의 지하수 질량 변화 정량이 부정확할 수 있고, 현장 조사 자료와 연동할 경우 과대 추정된 결과가 도출될 수 있다. InSAR는 특정 대수층에서 지표의 수직 변위가 지하수위와 비례한다는 원리를 이용, mm 단위의 지표 수직 변위를 측정하여 대수층 및 대수층 내 지하수의 물리적 특징을 정량화할 수 있다. 그러나, 지표의 토지 피복이 단순한 건조-반건조 기후 지역에 한정되어 적용되고 있으며, 지표면과의 긴밀도 값 손실이 우려되는 지역에서는 적용이 힘들다. 상기 두 위성을 이용하여 우리나라 지하수 수자원의 질량 변화 및 흐름 특징을 광역적으로 정량화하기 위해서는 우리나라의 지형 및 지질, 자연 조건에 알맞은 자료 전처리 알고리즘 개발 및 적용이 선행되어야 할 것이다.

직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작 (The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector)

  • 노시철;강상식;정봉재;최일홍;조창훈;허예지;윤주선;박지군
    • 한국방사선학회논문지
    • /
    • 제6권1호
    • /
    • pp.73-77
    • /
    • 2012
  • 최근 디지털 방사선 영상획득을 위한 평판형 X선 검출기에 이용되는 광도전체(a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ 등)에 대한 관심이 증대되고 있다. 본 연구에서는 입자침전법 적용이 가능한 광도전 물질을 이용하여 X선 영상 검출기 적용을 위한 필름층을 제작하여 평가하였다. 먼저, X선 영상에서 일반적으로 사용되는 에너지대역인 70 kVp 의 연속 X선에 대한 필름 두께별 양자효율을 몬테카를로 시뮬레이션을 통해 조사하였다. 평가결과, 현재 상용화된 500 ${\mu}m$ 두께의 a-Se 필름에 대한 양자효율인 64 %와 유사한 $HgI_2$의 필름의 두께는 180 ${\mu}m$ 정도였으며, 240 ${\mu}m$ 두께에서 74 %의 높은 양자효율을 보였다. 입자침전법을 이용하여 제작된 239 ${\mu}m$ 필름에 대한 전기적 측정결과, 10 $pA/mm^2$ 이하의 매우 낮은 암전류를 보였으며, X선 민감도는 1 $V/{\mu}m$의 인가전압에서 19.8 mC/mR-sec의 높은 감도를 보였다. 영상의 대조도에 영향을 미치는 신호 대 잡음비 평가결과 0.8 $V/{\mu}m$의 낮은 동작전압에서 3,125의 높은 값을 보였으며, 전기장의 세기가 높아질수록 암전류의 급격한 증가에 의해 SNR 값이 지수적으로 감소하였다. 이러한 결과는 종래의 a-Se을 이용하는 평판형 검출기를 입자 침전법으로 제작 가능한 필름으로 대체하여 저가형 고성능 영상검출기 개발이 가능할 것으로 기대된다.