• Title/Summary/Keyword: Energy consumption factor

Search Result 381, Processing Time 0.024 seconds

Study on the Safety of Kamikaekyuk-tang Ethanol Extract (가미계격탕 주정추출물의 안전성에 대한 연구)

  • Lee, Eun-Ok;Seo, Nam-Jun;Jung, Hee-Jae;Kang, Jong-Gu;Kim, Sung-Hoon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.4
    • /
    • pp.799-804
    • /
    • 2009
  • Kamikaekyuk-tang(KMKKT), a formula of ten Oriental herbs, was orientally designed to promote vital energy, to remove blood stasis, and to decrease inflammation for treating cancers. KMKKT and its component had potent antiandrogen and androgen receptor activities in prostate cancer and also inhibited angiogenesis induced by basic fibroblast growth factor (bFGF) in human umbilical vein endothelial cells and suppressed the tumor growth in LLC-bearing mice, and liver metastasis of colon 26-L5 cancer cells, suggesting a potent cancer preventive agent. Nevertheless, there is no safety study of KMKKT before clinical trial so far. Thus, in the current study, we investigated the toxicity about ethanol-extracted KMKKT. Male and female Spraque Dawley (SD) rats were given orally by KMKKT at 250, 500, and 1000 mg/kg for 4 weeks. Mortality, clinical signs and measured change of body weight, food consumption and water consumption were observed. In addition, we performed ophthalmologic, urinary, hematological, blood serum biochemical and histopathological examination. Any general toxicity was not found in KMKKT treated group. Also, there were no significant differences in the parameters such as body weight, food consumption and water consumption, a lot of urine and blood factor levels except WBC, MCHC and Ca level compared with control group. Although WBC and MCHC were elevated in female rats and Ca level was decreased in male rats, these were within normal ranges. Finally, we determined that maximum tolerated dose (MTD) was 1000 mg/kg and no observed adverse effect level (NOAEL) was 500 mg/kg. Taken together, these results demonstrated that KMKKT is very safe to SD rats.

Monitoring of the Carbon Emission and Energy Consumption of CVD and Etcher for Semiconductor Manufacturing (반도체 제조용 CVD 및 Etcher 장비의 탄소배출량과 에너지 소비량 모니터링)

  • Ko, Dong Guk;Bae, Sung Woo;Kim, Kwang Sun;Im, Ik-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.3
    • /
    • pp.19-22
    • /
    • 2013
  • The purpose of this study is to develop a system that can monitor the amounts of energy consumption during CVD and etching process for semiconductor manufacturing. Specifically, this system is designed to measure the $CO_2$ emission amounts quantitatively by measuring the flow rate of gas used and amount of power consumed during the processes. The processes of CVD equipment can be classified generally into processing step and cleaning step and all the two steps were monitored. In CVD and etcher equipments, various gases including Ar and $O_2$ are used, but Ar, $O_2$ and He were monitored with the use of the LCI data of Korea Environmental Industry & Technology Institute and carbon emission coefficients of EcoInvent. As a result, it was found that the carbon emission amounts of CVD equipment for Ar, $O_2$ and He were $0.030kgCO_2/min$, $4.580{\times}10^{-3}kgCO_2/min$ and $6.817{\times}10^{-4}kgCO_2/min$, respectively and those of etcher equipment for Ar and $O_2$ are $5.111{\times}10^{-3}kgCO_2/min$ and $7.172kgCO_2/min$, respectively.

Performance Prediction on the Application of a Ground-Source Heat Pump(GSHP) System in an Office Building (업무용 건물의 지열 히트펌프 시스템에 대한 성능 예측)

  • Sohn, Byonghu;Kwon, Han Sol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.9
    • /
    • pp.409-415
    • /
    • 2014
  • Ground-source heat pump (GSHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy efficiency. These systems use the ground as a heat source and the heat sink for cooling mode operation. The purpose of this simulation study is to evaluate the performance of a hypothetical GSHP system in an office building and to assess the energy saving effect against the existing HVAC systems (boiler and turbo chiller). We collected monthly energy consumption data from an actual office building ($32,488m^2$) in Seoul, and created a model to calculate the hourly building loads with EnergyPlus. In addition, we used GLD (Ground Loop Design) V8.0, a GSHP system design and simulation software tool, to evaluate hourly and monthly performance of the GSHP system. The energy consumption for the GSHP system based on the hourly simulation results were estimated to be 582.6 MWh/year for cooling and 593.2 MWh/year for heating, while those for the existing HVAC systems were found to be 674.5 MWh/year and 2,496.4 MWh/year, respectively. The seasonal performance factor (SPF) of the GSHP system was also calculated to be in the range of 3.37~4.28.

Separation of Succinic Acid from Organic Acid Mixture Using Electrodialysis (전기투석에 의한 유기산 혼합물로부터 숙신산의 분리)

  • Kim, Sang-Hun;Lee, Byung-Chul
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.266-271
    • /
    • 2005
  • This paper studied succinic acid recovery from organic acid mixture by using mono-polar membrane electrodialysis. Current efficiency, solute recovery efficiency, energy consumption, and separation factor were measured at various pHs and concentration ratios. The separation factor of succinic acid could be interpreted in terms of ionization degree, molecular weight, ionic conductance, average charge, and initial feed composition.

Development of a Low-Price Device for Standby Power Cut-off (저가형 대기전력 차단장치 개발)

  • Lee, Sang-Yun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.3
    • /
    • pp.115-121
    • /
    • 2015
  • A device which could cut off the consumption of standby power by electric or electronic devices at homes and offices while waiting for a command to carry out the main functions from the inside or the outside was developed at a low price. Efforts to save standby power have been made on a global scale as well as by advanced countries. The consumption of standby power in South Korea is also increasing gradually due to increasing trend in the number of electronic and electric devices per household, becoming a major factor for waste of electric energy. The previous standby power cutoff devices themselves have high electric energy consumption and complicated structures, making the purpose less meaningful. Therefore, a low-priced standby power cutoff device is suggested in this study, which compensates such problems and cuts off the consumption of standby power completely. The circuit of the suggested standby power cutoff device was designed and implemented by applying it to an earth leakage breaker and an (electrical) outlet. Experimental results show its superiority.

An Efficient Game Theory-Based Power Control Algorithm for D2D Communication in 5G Networks

  • Saif, Abdu;Noordin, Kamarul Ariffin bin;Dimyati, Kaharudin;Shah, Nor Shahida Mohd;Al-Gumaei, Yousef Ali;Abdullah, Qazwan;Alezabi, Kamal Ali
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.7
    • /
    • pp.2631-2649
    • /
    • 2021
  • Device-to-Device (D2D) communication is one of the enabling technologies for 5G networks that support proximity-based service (ProSe) for wireless network communications. This paper proposes a power control algorithm based on the Nash equilibrium and game theory to eliminate the interference between the cellular user device and D2D links. This leadsto reliable connectivity with minimal power consumption in wireless communication. The power control in D2D is modeled as a non-cooperative game. Each device is allowed to independently select and transmit its power to maximize (or minimize) user utility. The aim is to guide user devices to converge with the Nash equilibrium by establishing connectivity with network resources. The proposed algorithm with pricing factors is used for power consumption and reduces overall interference of D2Ds communication. The proposed algorithm is evaluated in terms of the energy efficiency of the average power consumption, the number of D2D communication, and the number of iterations. Besides, the algorithm has a relatively fast convergence with the Nash Equilibrium rate. It guarantees that the user devices can achieve their required Quality of Service (QoS) by adjusting the residual cost coefficient and residual energy factor. Simulation results show that the power control shows a significant reduction in power consumption that has been achieved by approximately 20% compared with algorithms in [11].

Environmental Impact of Soil Washing Process Based on the CO2 Emissions and Energy Consumption (토양세척 공정의 환경영향 분석 - 이산화탄소 배출량 및 에너지 사용량을 중심으로)

  • Kim, Do-Hyung;Hwang, Bo-Ram;Her, Namguk;Jeong, Sangjo;Baek, Kitae
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.119-125
    • /
    • 2014
  • This study evaluated the environmental impacts of a soil washing (SW) process, especially, we compared the on-site and off-site remediation of TPH-contaminated soil using green and sustainable remediation (GSR) tool. To assess relative contribution of each stage on environmental footprints in the entire soil washing process, we classified the process into four major stages: site foundation (stage I), excavation (stage II), separation & washing (stage III), and wastewater treatment (stage IV). In on-site SW process, the relative contribution of $CO_2$ emissions and energy consumption were 87.1% and 80.4%, respectively in stage I, and in off-site SW process, the relative contribution of $CO_2$ emissions and energy consumption were 82.7% and 80.5%, respectively in stage II. In conclusion, the major factor contributing environmental impact in the SW process were consumable materials including steel and stainless steel for washing equipment in on-site treatment and fuel consumption for transportation of soil in off-site treatment.

A Study on the Application of a Wind Power Generation System Using Outdoor Air on the Rooftop and Indoor Ventilation (건물 옥상외기와 실내배기를 활용한 풍력발전시스템 적용 연구)

  • Lee, Yong-Ho;Park, Jin-Chul;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.72-80
    • /
    • 2014
  • This study proposed a wind power generation system utilizing outdoor air on the rooftop and indoor ventilation, which would increase according to the building height, as a way to help to save energy consumption in a building by using wind power energy of the new renewable energy sources. The study measured the distribution of air currents and power generation according to the usage factor of exhaust pipes in the kitchen and bathroom and identified the elements to consider when applying a wind power generation system to buildings in order to use outdoor air on the rooftop increasing according to the height and the indoor ventilation produced in the facility vertical shafts inside the buildings by installing a wind power generation system on the rooftop. (1) The study measured the ventilation velocity of the kitchen hood and bathroom ventilation fan by changing the zone areas by the households according to the usage factor of [${\alpha}$]=33~100%. As a result, the kitchen ventilation pipe generated the ventilation wind of 3.0m/s or more at the usage factor of [${\alpha}$] 66% or higher, and the bathroom ventilation pipe generated ventilation velocity lower than 3.0m/s, the blade velocity of the wind power generator, even after the usage factor rose to [${\alpha}$]=100%. (2) As the old bathroom ventilation pipe generated the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, even with the rising usage factor [${\alpha}$], the application of an outdoor air induction module increased the ventilation velocity by 2.9m/s at the usage factor of [${\alpha}$]=33%, 3.8m/s at the usage factor of [${\alpha}$]=66%, and 3.6m/s at the usage factor of [${\alpha}$]=100%. Thus the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, or higher was secured. (3) The findings prove that the applicability of a wind power generation system using outdoor air on the rooftop and indoor ventilation is excellent, which raises a need for various efforts to increase the possibility of its commercialization such as securing its structural stability according to momentary gusts on the rooftop and typhoons in summer and making the structure light to react to the wind directions of outdoor air on the rooftop according to the seasons.

Modelling Voltage Variation at DC Railway Traction Substation using Recursive Least Square Estimation (순환최소자승법을 이용한 직류도시철도 변전소의 가선전압변동 모델링)

  • Bae, Chang-Han
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.6
    • /
    • pp.534-539
    • /
    • 2015
  • The DC overhead line voltage of an electric railway substation swings depending on the accelerating and regenerative-braking energy of trains, and it deteriorates the energy quality of the electric facility in the DC railway substation and restricts the powering and braking performance of subway trains. Recently, an energy storage system or a regenerative inverter has been introduced into railway traction substations to diminish both the variance of the overhead line voltage and the peak power consumption. In this study, the variance of the overhead line voltage in a DC railway substation is modelled by RC parallel circuits in each feeder, and the RC parameters are estimated using the recursive least mean square (RLMS) scheme. The forgetting factor values for the RLMS are selected using simulated annealing optimization, and the modelling scheme of the overhead line voltage variation is evaluated through raw data measured in a downtown railway substation.

Adaptive method for selecting Cluster Head according to the energy of the sensor node

  • Kim, Yong Min;LEE, WooSuk;Kwon, Oh Seok;Jung, Kyedong;Lee, Jong-Yong
    • International Journal of Advanced Culture Technology
    • /
    • v.4 no.2
    • /
    • pp.19-26
    • /
    • 2016
  • The most important factor in the wireless sensor network is the use of effective energy and increase in lifetime of the individual nodes in order to operate the wireless network more efficiently. For this purpose, various routing protocols have been developed. The LEACH such a protocol, well known among typical cluster routing protocols. However, when a cluster head is selected, the energy consumption may not be equal because it does not take into account the energy of the nodes. In this paper, we seek to improve the cluster head selection method according to residual energy of each sensor node. This method then adaptively applies the LEACH algorithm and the cluster head section algorithm with consideration of node energy in accordance with the energy of the whole sensor field. Through the simulation, it was found that this proposed algorithm was effective.