• Title/Summary/Keyword: Energy consumption component

Search Result 114, Processing Time 0.035 seconds

Performance Analysis of Balcony BIPV System (발코니형 BIPV시스템의 성능 분석)

  • Kim, Hyun-Il;Kang, Gi-Hwan;So, Jung-Hoon;Yu, Gwon-Jong;Park, Kyung-Eun;Lee, Kil-Song;Suh, Seung-Jik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.208-209
    • /
    • 2007
  • Photovoltaic(PV) based electricity production is pollution-free at the local as well as the global level, it does not emit greenhouse gases, it dose not dip into finite file resources and it can be easily integrated into the urban environment, close to major consumption needs. So BIPV(Building-Integrated Photovoltaics) system have been increased around the world. This paper presents measuring and analyzing performance of balcony BIPV system which have been installed and monitoring. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. By the results, it is very important to develop optimal design for the balcony PV system.

  • PDF

Thermal Performance Analysis for Optimal Operation of Solar Hot Water System (태양열 급탕시스템의 최적화 운전을 위한 열성능 분석)

  • Shin, U-Cheul;Yoon, Jong-Ho;Baek, Nam-Choon;Kwak, Hee-Yeul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.143-147
    • /
    • 2011
  • On-off differential controller is one of the very important component which has influence on the system performance of the solar hot water system. In this study, it was analysed the influence of "on-off" setting temperature on the system efficiency and the electrical consumption by circulation pump. This study was performed by computer simulation using TRNSYS program. The simulation system was developed in this study was verified the its reliability by the experimental results.

A Study on Countermeasures of Electronic Component Industry according to Korean Emission Trading Scheme Enforcement (국내 배출권거래제 시행에 따른 전자부품산업 대응방안 연구)

  • Choi, Eun Kyung;Lim, Hoseon;Lee, Min Young;Shin, Seung-chol
    • Journal of Climate Change Research
    • /
    • v.5 no.4
    • /
    • pp.331-338
    • /
    • 2014
  • The continued efforts to reduce GHG emission by international cooperation and each country are in progress. As part of these efforts, Korea's ETS is enforced in 2015. This was the time to make strategies for each company to respond Korea's ETS. This study was performed to suggest a draft of basic strategies for electronic component industry in current Korea's ETS stage are as follows; - Analyzing the nature of electronic component industry - Identifying needs for corresponding ETS of electronic component industry - Analyzing basic countermeasures for each stage of ETS - Suggesting drafts of basic strategies for electronic component industry in current Korea's ETS stage The result of this study, the current stage of Korea's ETS is moving from implementation of the scheme become determined and prepare the minimum corresponding to direct corresponding to the regulation and market change. Electronic component industry has many GHG emission growth(or change) factor, and it will be make electronic component industry as a buyer when Korea's ETS is enforced. Korea's ETS will be clearly act as a regulation rather than new business for electronic component industry. Therefore, identifying the Korea's ETS as a regulation is resonable strategy for corresponding the scheme. The basic strategies of electronic component industry th responding Korea's ETS are as follows; - Building internal organization and decision-making system before enforcement the Korea's ETS - Establishing internal basic corresponding strategies according to carbon price forecast scenarios - Considering the energy consumption and GHG emissions in design phase and preparing the global ETS market in mid or long term.

Dynamic Voltage Scaling (DVS) Considering the DC-DC Converter in Portable Embedded Systems (휴대용 내장형 시스템에서 DC-DC 변환기를 고려한 동적 전압 조절 (DVS) 기법)

  • Choi, Yong-Seok;Chang, Nae-Hyuck;Kim, Tae-Whan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.2
    • /
    • pp.95-103
    • /
    • 2007
  • Dynamic voltage scaling (DVS) is a well-known and effective power management technique. While there has been research on slack distribution, voltage allocation and other aspects of DVS, its effects on non-voltage-scalable devices has hardly been considered. A DC-DC converter plays an important role in voltage generation and regulation in most embedded systems, and is an essential component in DVS-enabled systems that scale supply voltage dynamically. We introduce a power consumption model of DC-DC converters and analyze the energy consumption of the system including the DC-DC converter. We propose an energy-optimal off-line DVS scheduling algorithm for systems with DC-DC converters, and show experimentally that our algorithm outperforms existing DVS algorithms in terms of energy consumption.

Desalting of tobacco extract using electrodialysis

  • Ge, Shaolin;Li, Wei;Zhang, Zhao;Li, Chuanrun;Wang, Yaoming
    • Membrane and Water Treatment
    • /
    • v.7 no.4
    • /
    • pp.341-353
    • /
    • 2016
  • Papermaking reconstituted tobacco is an important strategy for recycling the waste tobacco residues. To indentify the influences of the inorganic components on harmful components delivery in cigarette smoke, a self-made electrodialysis stack was assembled to desalt the tobacco extract. The influences of the applied current and extract content on the removal rate of the inorganic ions were investigated. Results indicated that the applied current was a dominant impact on the desalination performance. High currents lower than the limiting current density could accelerate the desalting efficiency but cause higher energy consumption. A current of 2 A, or current density of ${\sim}11mA{\cdot}cm^{-2}$, was an optimal choice by considering both the energy consumption and desalting efficiency. A 20% tobacco extract was an appropriate content for the electrodialysis process. More than 90% of inorganic ions could be removed under the optimum condition. The preliminary result indicated that removal of inorganic components was beneficial to decrease the harmful component delivery in cigarette smoke. Naturally, ED is an environmentally friendly and high-effective technology for desalting the tobacco extract.

Task Scheduling Technique for Energy Efficiency in Wireless Sensor Networks (무선 센서 네트워크 환경에서의 에너지 효율성을 고려한 태스크 스케줄링 기법)

  • Lee Jin-Ho;Choi Hoon;Baek Yun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.9A
    • /
    • pp.884-891
    • /
    • 2006
  • A wireless sensor node is typically battery operated and energy constrained. Therefore it is critical to design efficient power management technique and scheduling technique. In this paper, we propose an OS-level power management technique for energy saving of wireless sensor node, it is called EA-SENTAS (Energy-Aware Sensor Node TAsk Scheduling). It can decrease the energy consumption of a wireless sensor node to use task scheduling technique that shut down components or use low power mode of each component when not needed. Simulation results show that EA-SENTAS saves energy up to 56 percent to compare with conventional duty cycle.

Application of Conservation Voltage Reduction using Automatic Voltage Regulator of Linear Voltage Control in Campus Microgrid with Power Consumption Reduction (에너지 절감을 고려한 캠퍼스 마이크로그리드에서 선형 전압제어 방식의 AVR을 이용한 CVR의 적용)

  • Lim, Il-Hyung;Lee, Myung-Hwan;Shin, Yong-Hark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1039-1046
    • /
    • 2017
  • Campus microgrid is designed and built by considering not only power generation but also power consumption management as connected microgrid type because the main goal of the campus microgrid is to save power consumption costs. There are many functions to achieve the goal and they are mainly to use generation-based functions such as islanding operation for peak management and for emergency events. In power distribution operation, Conservation Voltage Reduction (CVR) is applied in order to reduce power consumption. The CVR is defined as a function for load consumption reduction by voltage reduction in order to reduce peak demands and energy consumption. However, application of CVR to microgrid is difficult because the microgrid cannot control a tap of transformer in a substation and the microgrid normally is not designed with phase modifying equipment like a step-voltage-regulator which can control voltage in power distribution system operation. In addition, an impact of the CVR is depended on load characteristics such as a normal load, a rated power, and synchronous motors. Therefore, this paper proposes an application of CVR using linear voltage control based AVR in campus microgrid with power consumption reduction considering characteristics of load and component in the microgrid. The proposed system can be applied to each buildings by a configuration of power distribution cables; and the application results and CVR factor are presented in this paper.

Numerical Study on the Thermal Control Device for Satellite Components Using the Phase Change Material Combined with Heat Pipe in Parallel (상변화물질과 열관을 병렬 조합한 위성부품 열제어장치의 수치해석적 연구)

  • Shin, Yoon Sub;Kim, Tae Su;Kim, Taig Young;Seo, Young Bae;Seo, Jung-gi;Hyun, Bum-Seok;Cheon, Hyeong Yul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.4
    • /
    • pp.373-379
    • /
    • 2016
  • The thermal control device for the periodic working component combined solid-liquid phase change material (PCM) with heat pipes is designed and numerically studied. Due to high latent heat and retaining constant temperature during melting process the component peak temperature, not withstanding small radiator size, is reduced. The warm-up heater power consumption to keep the minimum allowed temperature is also cut down since the accumulated thermal energy is released through the solidification. The thermal buffer mass (TBM) made of Al can give the similar effect but the mass and power consumption of warm-up heater should increase compared to PCM. The amount of PCM can be optimized depending on the component heat dissipation and on/off duty time.

Nonlinear collision analysis of heavy trucks onto steel highway guard fences

  • Itoh, Yoshito;Liu, Chunlu;Usami, Koichi
    • Structural Engineering and Mechanics
    • /
    • v.12 no.5
    • /
    • pp.541-558
    • /
    • 2001
  • The design specifications of guard fences in Japan were reexamined and the revised specifications were implemented from April 1999. Because of the huge consumption in time and cost to test the performances of full-scale guard fences in the field, some assumptions are adopted while modifying the design specifications, and numerical analyses are necessary to confirm the impact performance and safety level of new types of steel highway guard fences. In this study, the finite element models are developed for the heavy trucks and steel highway guard fences to reenact their behaviors, and the solution approach is carried out using nonlinear dynamic analysis software of structures in three dimensions (LS-DYNA). The numerical simulation results are compared with the full-scale on-site testing results to verify the proposed analysis procedure. The collision process is simulated and it is also made possible to visualize the movement of the truck and the performances of guard fences. In addition, the energy shift of the truck kinetic energy to the truck and guard fence Internal energy, and the energy absorption of each guard fence component are studied for the development of a new design methodology of steel highway guard fences based on the energy absorption capacity.

Heating and Cooling Energy Demand Evaluating of Standard Houses According to Layer Component of Masonry, Concrete and Wood Frame Using PHPP (PHPP를 활용한 조적, 콘크리트, 목조 레이어 구성별 표준주택 냉·난방 에너지 요구량 평가)

  • Kang, Yujin;Lee, Junhee;Lee, Hwayoung;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.1-11
    • /
    • 2017
  • A lot of the energy are consumed on heating and cooling in buildings. The buildings need to minimize the heating and cooling loads for $CO_2$ emissions and energy consumption reduction. In recently, also demand of detached houses were increase while the residential culture was changed. The structure of the domestic detached houses can be divided into masonry, concrete, wood frame houses. Therefore, in this study, the heating and cooling load and energy demand were analyzed on the equal area detached house consisting of three structural methods (Masonry, Concrete, Wood frame). Layer of wall, roof, and floor were composited by structure. Thermal transmittance (U-value) of each layer was using the PHPP calculation for considering stud, such as the wood frame wall. In addition, the case of without considering for studs in wood frame wall (Non-studs) was analyzed in order to compare the difference between studs or not. Analysis was performed using self-developed heating and cooling load calculation program (CHLC) based excel and ECO2. The results of cooling and heating load and energy demand showed the highest values in the wood frame structure, and the concrete structure were confirmed to maintain a high value secondly. Two structure were determined to be disadvantageous on the energy consumption. Consequently, the masonry structure have an advantage over the other structure under the identical conditions. It was determined that if the except for thermal bridges due to the studs in the wood frame structure, it can be reduced the energy consumption.