• Title/Summary/Keyword: Energy consumption comparison

Search Result 448, Processing Time 0.027 seconds

Comparative analysis of the fuel consumption during Descent Flight (강하비행시의 연료소모량 비교분석)

  • Shin, Dai-Won;Kim, Yong-Seok
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.19 no.2
    • /
    • pp.58-63
    • /
    • 2011
  • A Continuous Descent Approach(CDA) is defined as a simple, cost-effective, noise and emission abatement technique for any powered aircraft on approach. CDA also can be optimised within energy, speed and safety constraints by avoiding unnecessary flap, air brake and engine thrust. This study includes comparison on fuel consumption between Continuous Descent type and Step Down type by using flight data. In particular, we investigated fuel flow per hour, calibrated airspeed and pressure altitude for all flight time. During descent flight, the fuel consumption of Continuous Descent type was less than the fuel consumption of Step Down type.

An experimental study on the optimal control algorithm for central heating system (중앙난방 시스템의 최적제어 알고리즘의 적용을 위한 실험적 연구)

  • Ahn, Byung-Cheon;Chun, Won-Ik
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.463-468
    • /
    • 2005
  • An experimental study on the optimal control algorithm for central heating system for minimizing energy consumption while maintaining the comfort of indoor thermal en vironment in terms of the environmental variables such as loads and weather. experimental study has been done by one using the prototype of central heating system. As a result the optimal control algorithm shows good energy performance in comparison with conventional control one.

  • PDF

Effects of Various Factors on the Energy Consumption of Korean-Style Apartment Houses (한국형 아파트의 냉난방 에너지에 미치는 제 인자의 영향)

  • 유호선;현석균;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.972-980
    • /
    • 2002
  • This work is aimed at estimating the effects of various factors on the energy consumption of Korean-style apartment houses using TRNSYS. The factors considered here include the nominal size of floor area, type of remodeling, azimuth, sidewall insulation, and window type. Based on some assumptions, an actual apartment house is simplified into a model that is used for thermal load calculations. The simplified model is validated by showing a good agreement with the actual one in the predicted result. Remodeling balconies into unconditioned buffer spaces yields a favorable thermal performance in comparison with the original type regardless of the nominal size. Incorporating balconies into a conditioned indoor space leads to sharp increases in thermal loads, which must be avoided in view of energy conservation as well as structural problem. A quantitative assessment on the azimuthal effect indicates that the heating energy can be saved up to 16% by taking the south or southeast direction. Reduction in the heating load with enhancing the sidewall insulation is gradual, so that a cost-effectiveness analysis may be needed when amending the regulations concerned. Glazing appears to significantly affect the heat transfer through window. A typical case illustrates that the heating load is decreased about 25% by simply adopting triple glazing instead of double glazing.

Performance Analysis of Switching Strategy in LTE-A Heterogeneous Networks

  • Peng, Jinlin;Hong, Peilin;Xue, Kaiping
    • Journal of Communications and Networks
    • /
    • v.15 no.3
    • /
    • pp.292-300
    • /
    • 2013
  • Nowadays, energy saving has become a hot topic and information and communication technology has become a major power consumer. In long term evolution advanced (LTE-A) networks, heterogeneous deployments of low-power nodes and conventional macrocells provide some new features, such as coverage extension, throughput enhancement, and load balancing. However, a large-scale deployment of low-power nodes brings substantial energy consumption and interference problems. In this paper, we propose a novel switching strategy (NS), which adaptively switches on or off some low-power nodes based on the instantaneous load of the system. It is compatible with the microcells' load balancing feature and can be easily implemented on the basis of existing LTE-A specifications. Moreover, we develop an analytical model for analyzing the performance of system energy consumption, block rate, throughput, and energy efficiency. The performance of NS is evaluated by comparison with existing strategies. Theoretical analysis and simulation results show that NS not only has a low block rate, but also achieves a high energy efficiency.

Data Direction Aware Clustering Method in Sensor Networks (데이터 전송방향을 고려한 센서네트워크 클러스터링 방법)

  • Jo, O-Hyoung;Kwon, Tae-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.7B
    • /
    • pp.721-727
    • /
    • 2009
  • Wireless Sensor Networks(WSN) make use of low cost and energy constrained sensor nodes. Thus, reaching the successful execution of its tasks with low energy consumption is one of the most important issues. The limitation of existing hierarchical algorithms is that many times the data are transmitted to the opposite direction to the sink. In this paper, DDACM (Data Direction Aware Clustering Method) is proposed. In this method, the nearest node to the sink is elected as cluster head, and when its energy level reaches a threshold value, the cluster head is reelected. We also make a comparison with LEACH showing how this method can reduce the energy consumption minimizing the reverse direction data transmission.

Energy Efficient Architecture Using Hardware Acceleration for Software Defined Radio Components

  • Liu, Chen;Granados, Omar;Duarte, Rolando;Andrian, Jean
    • Journal of Information Processing Systems
    • /
    • v.8 no.1
    • /
    • pp.133-144
    • /
    • 2012
  • In order to make cognitive radio systems a practical technology to be deployed in real-world scenarios, the core Software Defined Radio (SDR) systems must meet the stringent requirements of the target application, especially in terms of performance and energy consumption for mobile platforms. In this paper we present a feasibility study of hardware acceleration as an energy-efficient implementation for SDR. We identified the amplifier function from the Software Communication Architecture (SCA) for hardware acceleration since it is one of the functions called for most frequently and it requires intensive floating-point computation. Then, we used the Virtex5 Field-Programmable Gate Array (FPGA) to perform a comparison between compiler floating-point support and the on-chip floating-point support. By enabling the on-chip floating-point unit (FPU), we obtained as high as a 2X speedup and 50% of the overall energy reduction. We achieved this with an increase of the power consumption by no more than 0.68%. This demonstrates the feasibility of the proposed approach.

Comparison Study of Air-conditioning Systems using LCC Analysis (LCC를 이용한 공조 방식별 비교 연구)

  • Kim, Joung-Kuk;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.3
    • /
    • pp.12-18
    • /
    • 2012
  • The purpose of this study is to make an economic analysis(Life cycle cost) of selecting optimal air conditioning system for a research building which is 8 stories with a total floor area of $32,010m^2$. Energy consumptions of three proposed air-conditioning systems(Alt-1,2,3) that reflect the government green-growth policy are calculated and compared. The results show that life cycle cost of Alt-3(Ventilation DX AHU+EHP) is less than Alt-1(EHP+ventilation DX AHU) by 5.1%, and Alt-2(Absorption chiller/heater+EHP) by 34.3%. Annual energy consumption of Alt-3 is less than Alt-1 by 9.9%, and Alt-2 by 37.4%. Annual $CO_2$ emission of Alt-3 is less than Alt-1 by 9.9%, and Alt-2 by 0.2%.

Evaluation of Delamination for Fiber Reinforced Metal Laminates Using a Pseudo Crack Model (가균열 모델을 이용한 섬유강화 금속적층재의 층간분리 평가법)

  • Song, Sam-Hong;Kim, Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.2
    • /
    • pp.174-180
    • /
    • 2004
  • If Fiber Reinforced Metal Laminates(FRMLs) were delaminated, the decrease of stiffness and fiber bridging effect would result in the sudden aggravation of fatigue characteristics. It was reported that the delamination of FRMLs resulted from the crack of metal layers and that it depended on the crack growth. While cracks were made in FRMLs containing a saw-cuts under fatigue loading, cracks could be produced or not in FRMLs with circular holes under the same condition. When the FRMLs with the circular holes produce not the crack but the delamination, it is not possible to analyze it by the conventional fracture parameters expressed as the function of the crack. And so, this research suggests a new analytical model of the delamination to make the comparison of the delamination behavior possible whenever the cracks occur or not. Therefore, a new analytical model called Pseudo Crack Model(PCM) was suggested to compare the delaminations whether cracks were made or not. The relationship between the crack energy consumption rate( $E_{crack}$) and the delamination energy consumption rate( $E_{del}$) was discussed and it was also known that the effect of $E_{del}$ was larger than that of $E_{crack}$.

Combustion Characteristics of a Direct Injection Agricultural Diesel Engine with Rapeseed Oil (유채유를 연료로 한 직접분사식 농용 디젤기관의 연소특성)

  • Choi, S.H.;Byeon, J.W.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.3
    • /
    • pp.135-139
    • /
    • 2009
  • Harmful exhaust emissions of diesel engines are recognized as main causes of air pollution in these days. But, the direct injection diesel engine is widely used for sake of minimization on energy consumption. Because biodiesel fuel is a renewable and alternative fuel for a diesel engine, its usability is expanded. To investigate the effect of biodiesel fuel(extracted from rapeseed oil) on the characteristics of performance and exhaust emissions in an agricultural diesel engine, the biodiesel fuel derived from rapeseed oil was applied in this study. Smoke emission of esterified rapeseed oil was reduced remarkably by approximately 44.5% at 1500 rpm, full load in comparison with the commercial diesel fuel. The power, torque and brake specific energy consumption of the diesel engine showed very slight differences. It was concluded that esterified rapeseed oil could be utilized effectively as an alternative and renewable fuel for agricultural direct injection diesel engines.

Design of a Low Power 108-bit Conditional Sum Adder Using Energy Economized Pass-transistor Logic(EEPL) (EEPL을 사용한 저 전력 108-bit 조건합 가산기의 설계)

  • 조기선;송민규
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.363-367
    • /
    • 1999
  • In this paper, a novel 108-bit conditional sum adder(CSA) with Energy Economized Pass-transistor Logic(EEPL) is proposed. A new architecture is adopted, in order to obtain a high speed operation, which is composed of seven modularized 16-bit CMS's and two separated carry generation block. Further a design technique based on EEPL is proposed to reduce the power consumption. With 0.65${\mu}{\textrm}{m}$ single poly, triple metal, 3.3V CMOS process, its operating speed is about 4.95㎱ and the power consumption is reduced in comparison with that of the conventional adder.

  • PDF