• 제목/요약/키워드: Energy and directional distribution

검색결과 44건 처리시간 0.033초

Study of neutron energy and directional distribution at the Beloyarsk NPP selected workplaces

  • Pyshkina, Mariia;Vasilyev, Aleksey;Ekidin, Aleksey;Nazarov, Evgeniy;Nikitenko, Vitaly;Pudovkin, Anton
    • Nuclear Engineering and Technology
    • /
    • 제53권5호
    • /
    • pp.1723-1729
    • /
    • 2021
  • Energy and directional distribution of neutrons at the Beloyarsk NPP workplaces is a subject of this study. Measurements of H*(10) rate and neutron energy distribution were taken at 8 workplaces, which can be divided into three categories: work with spent or fresh nuclear fuel, work with radionuclide neutron sources, work at the rooms adjusted to reactors. The Hp(10) measurements were performed only at 6 out of 8 locations, due to the fact that long term placing of an effective neutron moderator in fresh nuclear fuel storage facility is forbidden. As a result of the research energy and direction distribution of the neutron fields at 8 locations of the Beloyarsk NPP workplaces was obtained. To estimate the accuracy of the H*(10) rate and Hp (10) measurements the reference values of dose equivalents were calculated using energy and directional distribution. To take into account the difference between the reference values and the measured results site-specific correction factors were calculated.

Directional Wigner-Ville Distribution and Its Application for Rotating- Machinery Condition Monitoring

  • Kim, Dong-Wan;Ha, Jae-Hong;Shin, Hae-Gon;Lee, Yoon-Hee;Kim, Young-Baik
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(1)
    • /
    • pp.587-593
    • /
    • 1996
  • Vibration analysis is one of the most powerful tools available for the detection and isolation of incipient faults in mechanical systems. The methods of vibration analysis in use today and under continuous study are broad band vibration monitoring, time domain analysis, and frequency domain analysis. In recent years, great interest has been generated concerning the use of time-frequency representation and its application for a machinery diagnostics and condition monitoring system. The objective of the research described in this paper was to develop a new diagnostic tool for the rotating machinery. This paper introduces a new time-frequency representation, Directional Wigner-Ville Distribution, which analyses the time- frequency structure of the rotating machinery vibration.

  • PDF

Proposed Distribution Voltage Control Method for Connected Cluster PV Systems

  • Lee, Kyung-Soo;Yamaguchi, Kenichiro;Kurokawa, Kosuke
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.286-293
    • /
    • 2007
  • This paper proposes a distribution voltage control method when a voltage increase condition occurs due to reverse power flow from the clustered photovoltaic (PV) system. This proposed distribution voltage control is performed a by distribution-unified power flow controller (D-UPFC). D-UPFC consists of a hi-directional ac-ac converter and transformer. It does not use any energy storage component or rectifier circuit, but it directly converts ac to ac. The distribution model and D-UPFC voltage control using the ATP-EMTP program were simulated and the results show the voltage increase control in the distribution system.

신재생에너지원이 연계된 22.9[kV] 배전계통의 양방향 리클로저와 섹셔널라이저 보호협조 방안 (A study of the directional recloser and sectionalizer protective coordination at 22.9[kV] distribution system with new renewable energy generation)

  • 이연화;최준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.525-526
    • /
    • 2007
  • Recently, there has been growing interest in utilizing distributed generation (DG). However, an insertion of DG to existing distribution system can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc,. The typical protection system of the existing distribution system is designed for radial network. But penetration of DG to distribution system changes existing unidirectional power flow to bidirectional power flow. Therefore, investigation to cover whole field of distribution system must be accomplished such as changing of protection devices rating by increasing fault current, reevaluation of protective coordination. This paper presents that PSCAD/EMTDC simulations was accomplished to analyze effect of DG on the distribution protective coordination. In addition, directional recloser-sectionalizer coordination are evaluates distribution system with DG by using PSCAD/EMTDC simulation.

  • PDF

D-UPFC Application as the Series Power Device in the Massive Roof-top PVs and Domestic Loads

  • Lee, Kyungsoo
    • Current Photovoltaic Research
    • /
    • 제4권4호
    • /
    • pp.131-139
    • /
    • 2016
  • This paper shows the series power device in the massive roof-top PVs and domestic loads. D-UPFC as the series power device controls the distribution voltage during voltage rise (or fall) condition. D-UPFC consists of the bi-directional ac-ac converter and the transformer. In order to verify the D-UPFC voltage control, the distribution model is used in the case study. D-UPFC enables the voltage control in the distribution voltage range. Dynamic voltage control from voltage rise and voltage fall conditions is performed. Scaled-down experimental test of the D-UPFC is verified the voltage control and it is well performed without high voltage spikes in the inductive load.

18650 Li-ion battery Module의 Cell-to-Cell 온도 편차 최소화를 위한 양방향 냉각에 대한 실험적 연구 (Experimental Study on Bi-directional Air Cooling System for 18650 Li-ion Battery Module to Minimize Cell-to-Cell Temperature Variation)

  • 장호선;박민규;전지환;박성수;김태우;박성진
    • 한국수소및신에너지학회논문집
    • /
    • 제28권4호
    • /
    • pp.407-418
    • /
    • 2017
  • Battery heat management is essential for high power and high energy battery system because it affects its performance, longevity, and safety. In this paper, we investigated the temperature of the 18650 Lithium Ion Battery Module used in a Energy Storage System (ESS) and the cooling method to minimize cell-to-cell temperature variation of battery module. For uniform temperature distribution within a battery module, the flow direction of the coolant in a battery module has been changed according to the time interval, and studied the effect of the cooling method on the temperature uniformity in a battery module which includes a number of battery cells. The experimental results show that bi-directional battery cooling method can effectively reduce the cell-to-cell temperature variation compared with the one-directional battery cooling. Furthermore, it is also found that bi-directional battery cooling can reduce the maximum temperature in a battery module.

EMTP를 이용한 ESS가 연계된 배전계통에서 직격뢰 발생 시 계통 및 ESS 측의 서지 해석 (Analysis of Surge in Distribution System and ESS due to Direct Lightning in Distribution System with ESS using EMTP)

  • 서훈철
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.47-53
    • /
    • 2015
  • The study concerning about the grid connection of the large-capacity energy storage system(ESS) is increasing. However, the transient study such as lightning or switching surge necessarily occurred at power system with ESS has been hardly performed. Therefore, this paper performs the analysis of lightning surge in distribution system with ESS using electromagnetic transient program(EMTP). The battery model in Matlab/Simulink is modeled by EMTP, which is the specialized software for power system transient study. Also, the bi-directional power electronics for interconnection of the battery and distribution system are modeled by EMTP. When the lightning is occurred at interconnection point of ESS, this paper simulates the existence of ESS and operation conditions of ESS and analyzes the surge in distribution system and ESS according to the various conditions.

The Impact of Product Distribution and Information Technology on Carbon Emissions and Economic Growth: Empirical Evidence in Korea

  • Lee, Jung Wan
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제1권3호
    • /
    • pp.17-28
    • /
    • 2014
  • The paper deals with the impact of the product distribution and information technology sectors on energy resource use, carbon emissions and economic growth by examining the long-run equilibrium relationships and Granger causal relationships among these variables in South Korea. The quarterly time series data from the first quarter of 1970 to the third quarter of 2010 (163 observations) are collected and retrieved from the Bank of Korea database. The paper examines the long-run equilibrium relationships using cointegration techniques and Granger causality using vector error correction models. Test results indicate a long-run equilibrium relationship exists among these variables. In testing directional causality, both the product distribution and the information technology sectors show direct effects on economic growth but only marginal effects on carbon emissions.

Fick's second law 를 이용한 수냉식 발전기 고정자 권선의 건전성 예지 (Health prognostics of stator Windings in Water-Cooled Generator using Fick's second law)

  • 윤병동;장범찬;김희수;배용채
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.533-538
    • /
    • 2014
  • Power generator is one of the most important component of electricity generation system to convert mechanical energy to electrical energy. I t designed robustly to maintain high system reliability during operation time. But unexpected failure of the power generator could happen and it cause huge amount of economic and social loss. To keep it from unexpected failure, health prognostics should be carried out In this research, We developed a health prognostic method of stator windings in power generator with statistical data analysis and degradation modeling against water absorption. We divided whole 42 windings into two groups, absorption suspected group and normal group. We built a degradation model of absorption suspected winding using Fick's second law to predict upcoming absorption data. Through the analysis of data of normal group, we could figure out the distribution of data of normal windings. After that, we can properly predict absorption data of normal windings. With data prediction of two groups, we derived upcoming Directional Mahalanobis Distance (DMD) of absorption suspected winding and time vs DMD curve. Finally we drew the probability distribution of Remaining Useful Life of absorption suspected windings.

  • PDF

절리의 기하학적 속성이 절리성 암반의 이방적 변형 특성에 미치는 영향 (Effect of Joint Geometry on Anisotropic Deformability of Jointed Rock Masses)

  • 류성진;엄정기
    • 자원환경지질
    • /
    • 제53권3호
    • /
    • pp.271-285
    • /
    • 2020
  • 본 연구는 절리의 기하학적 속성이 절리성 암반의 변형 특성에 미치는 영향을 평가하기 위하여 삼차원 불연속절리망(DFN; discrete fracture network) 시스템에 대한 개별요소법 기반의 응력-변형 해석과 관련된 수치실험을 수행하였다. 1~2 개의 확정적 방향성을 갖는 절리군을 사용하여 절리의 빈도와 길이분포를 달리하며 추계론적으로 생성한 총 12개의 1000㎥ 정육면체 DFN 블록에 대하여 삼차원 직교좌표계의 축 방향에 따른 변형계수가 산정되었다. 또한, 일부 DFN 블록은 삼차원상에서 매 30° 간격의 선주향 및 선경사 방향을 축차응력 방향으로 설정하고 변형계수를 산정하였다. 절리의 길이가 증가할수록 DFN 블록의 변형계수는 더욱 저감되는 것으로 평가되었다. 절리의 빈도 증가는 절리의 길이가 짧아서 상대적으로 암교 효과가 큰 경우 DFN 블록의 변형계수 저감에 유의미한 영향을 미치지 못 할 가능성도 있지만 절리길이가 길수록 절리빈도의 증가가 DFN의 이방적 변형계수에 지대한 영향을 미치는 것으로 평가되었다. 절리의 길이와 빈도 변화에 따른 이방적 변형계수의 변화는 DFN에 분포하는 절리군의 개수 및 방향성에 크게 좌우된다. DFN 블록의 변형 특성은 삼차원상의 방향에 따라 다르게 발현되는 것으로 평가되었다. 마지막으로 본 연구는 절리의 기하학적 속성이 고려된 응력-변형 해석을 위한 수치해석 절차를 제시하였으며 현장규모의 실무 적용을 위한 방법론에 대하여 토의하였다.