• 제목/요약/키워드: Energy Storage System, ESS

검색결과 400건 처리시간 0.027초

신재생 에너지가 도입된 전력저장장치의 첨두부하절감 효과를 고려한 최적 구성 알고리즘 (Optimal Configuration Algorithm for ESS with Renewable Energy Resources Considering Peak-shaving Effects)

  • 이나은;김욱원;김진오
    • 전기학회논문지
    • /
    • 제63권9호
    • /
    • pp.1199-1205
    • /
    • 2014
  • A power system configuration has been increasingly advanced with a number of generating units. In particular, renewable energy resources are widely introduced due to the environmental issues. When applying the renewable energy sources with the ESS (Energy Storage System), the ESS is the role of a potential generating resource in the power system while mitigating the output volatility of renewable energy resources. Thus, for applications of the ESS, the surrounding environment of it should be considered, which means that capacity and energy of the ESS can be affected. Moreover, operation strategy of the ESS should be proposed according to the installation purpose as well as the surrounding environment. In the paper, operation strategy of the ESS is proposed considering load demand and the output of renewable energy resources on a hourly basis. Then, the cost of electrical energy is minimized based on the economic model that consists of capital cost, operation cost, fuel cost, and grid cost for a year. It is sure that peak-shaving effects can be achieved while satisfying the minimum cost of electrical energy.

Simulink 모델을 활용한 주파수추종용 ESS 운전 특성분석 (Historical Operation Characteristic Analysis of Energy Storage System for Governor Free using Simulink Model)

  • 조성민;임지훈;이성은
    • 전기학회논문지
    • /
    • 제66권6호
    • /
    • pp.905-910
    • /
    • 2017
  • As the development of BESS(Battery Energy Storage System), the application of BESS in load frequency control is considered as effective method. So, KEPCO(Korea Electric Power Corporation) have installed about 236MW ESS for GF(Govner Free) function from 2014. In this paper, we implemented Simulink Model for KEPCO GF ESS and analyzed one year historical operation data generated by Simulink model and actually measured frequency data. The operation results were divided into action for maintaining SOC and frequency. In addition, we also analyzed cycle life of GF ESS using two ESS cycle life model. We concluded the ESS cycle life models are not appropriate, because Most of the SOC swing in operation results are below 10%.

도시철도 시스템 전기요금 절감을 위한 혼합정수계획법 기반 ESS(에너지저장장치) 스케줄링 기법 (Mixed Integer Programming (MIP)-based Energy Storage System Scheduling Method for Reducing the Electricity Purchasing Cost in an Urban Railroad System)

  • 고락경;공성배;주성관
    • 전기학회논문지
    • /
    • 제64권7호
    • /
    • pp.1125-1129
    • /
    • 2015
  • Increasing peak load is one of the major concerns about operation of urban railroad systems. Since ESSs (Energy Storage Systems) have a great potential for shaving the peak load, there has been a growing interest in the use of ESS for peak load reduction. Also, ESS can be optimally scheduled to minimize the electricity purchasing cost under a given ToU (Time-of-Use) tariff by taking advantage of electricity price difference between peak and off-peak time. This paper presents a Mixed Integer Programming (MIP)-based ESS scheduling method to minimize the electricity purchasing cost under a ToU tariff for an urban railroad system.

Development of ESS Scheduling Algorithm to Maximize the Potential Profitability of PV Generation Supplier in South Korea

  • Kong, Junhyuk;Jufri, Fauzan Hanif;Kang, Byung O;Jung, Jaesung
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2227-2235
    • /
    • 2018
  • Under the current policies and compensation rules in South Korea, Photovoltaic (PV) generation supplier can maximize the profit by combining PV generation with Energy Storage System (ESS). However, the existing operational strategy of ESS is not able to maximize the profit due to the limitation of ESS capacity. In this paper, new ESS scheduling algorithm is introduced by utilizing the System Marginal Price (SMP) and PV generation forecasting to maximize the profits of PV generation supplier. The proposed algorithm determines the charging time of ESS by ranking the charging schedule from low to high SMP when PV generation is more than enough to charge ESS. The discharging time of ESS is determined by ranking the discharging schedule from high to low SMP when ESS energy is not enough to maintain the discharging. To compensate forecasting error, the algorithm is updated every hour to apply the up-to-date information. The simulation is performed to verify the effectiveness of the proposed algorithm by using actual PV generation and ESS information.

교류전기철도에서의 에너지저장시스템 적용효과 예측 (Estimation about Application Effects of Energy Storage System at AC Electric Railway)

  • 이장무;이한민;김길동
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1849-1854
    • /
    • 2010
  • Energy Storage System(ESS) is installed at feeding line of railway substation. ESS will absorb regenerative energy when train braking and also charge electric energy when feeding line is no load condition. Absorbed and charged energy will be supplied when train is accelerating condition. Due to ESS the energy variation will be minimized and this effect is estimated.

  • PDF

Evaluation of various large-scale energy storage technologies for flexible operation of existing pressurized water reactors

  • Heo, Jin Young;Park, Jung Hwan;Chae, Yong Jae;Oh, Seung Hwan;Lee, So Young;Lee, Ju Yeon;Gnanapragasam, Nirmal;Lee, Jeong Ik
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2427-2444
    • /
    • 2021
  • The lack of plant-side energy storage analysis to support nuclear power plants (NPP), has setup this research endeavor to understand the characteristics and role of specific storage technologies and the integration to an NPP. The paper provides a qualitative review of a wide range of configurations for integrating the energy storage system (ESS) to an operating NPP with pressurized water reactor (PWR). The role of ESS technologies most suitable for large-scale storage are evaluated, including thermal energy storage, compressed gas energy storage, and liquid air energy storage. The methods of integration to the NPP steam cycle are introduced and categorized as electrical, mechanical, and thermal, with a review on developments in the integration of ESS with an operating PWR. By adopting simplified off-design modeling for the steam turbines and heat exchangers, the results show the performance of the PWR steam cycle changes with respect to steam bypass rate for thermal and mechanical storage integration options. Analysis of the integrated system characteristics of proposed concepts for three different ESS suggests that certain storage technologies could support steady operation of an NPP. After having reviewed what have been accomplished through the years, the research team presents a list of possible future works.

ESS기반 클린에너지, 스마트홈 IoT 플랫폼 연구 (A Study on ESS-based Clean Energy, Smart Home IoT Platform)

  • 김희철
    • 한국전자통신학회논문지
    • /
    • 제13권1호
    • /
    • pp.147-152
    • /
    • 2018
  • 본 연구는 전력에너지 효율사용 분야의 주요 설비인 ESS(: Energy Storage System, 에너지저장장치)를 기반으로 한 공동주택의 수요관리 및 에너지절감 방안을 연구하고 제반 기술적 요소와 운용에 필요한 표준화를 제시함으로서 ESS 산업 확산에 기여한다. 또한, 공동주택 및 스마트 홈을 대상으로 ESS 시장의 창출을 위하여 주택 IoT 기술을 활용, 공동주택과 스마트 홈 기반 ESS을 통합하여 전력사용자의 이용 효율성과 경제성 확보가 실현되어 기존 ESS 보다 우월한 전력사용자의 수용성을 재고 할 수 있는 사업모델을 연구하고자 한다.

HILS를 이용한 신재생 에너지원이 포함된 에너지 저장시스템의 운영 시나리오 개발 (Development of Operation Scenarios by HILS for the Energy Storage System Operated with Renewable Energy Source)

  • 신동철;전지환;박성진;이동명
    • 전기학회논문지
    • /
    • 제67권2호
    • /
    • pp.224-232
    • /
    • 2018
  • According to government policy, renewable energy facility such as solar power generation is being implemented for newly constructed buildings. In recent years, the introduction of Energy Storage System (ESS) served as an emergency power for replacing an existing diesel generator has been increasing. Furthermore, in order to expand the efficacy of the ESS operation, operation in combination with renewable energy sources such as solar and wind power generation is increasing. Hence, development of the ESS operation algorithms for emergency mode as well as the peak power cut mode, which is the essential feature of ESS, are necessary. The operational scenarios of ESS need to consider load power requirement and the amount of the power generation by renewable energy sources. For the verification of the developed scenarios, tests under the actual situation are demanded, but there is a difficulty in simulating the emergency operation situation such as system failure in the actual site. Therefore, this paper proposes simulation models for the HILS(Hardware In the Loop Simulation) and operation modes developed through HILS for the ESS operated with renewable energy source under peak power reduction and emergency modes. The paper shows that the ESS operation scenarios developed through HILS work properly at the actual site, and it verifies the effectiveness of the control logic developed by the HILS.

ESS(Energy Storage System) 기술동향에 관한 연구 (The Study on the Technical Trends of ESS(Energy Storage System))

  • 배진용;김용;권순도;이은영;조규만;엄태민;홍성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.637-638
    • /
    • 2015
  • This paper review the technical trends of ESS(Energy Storage System). The ESS has been displaced by cathode, anode, electrolyte, and separator. The lithium-ion battery is getting the most attention in the ESS. In this paper, we especially want to review a look at technology trends of the cathode and the separator for lithium-ion battery.

  • PDF

ESS 연동형 스마트 플러그 기반의 미디어 플랫폼 설계 (Design of Smart Plug based Media Platform interlocking with ESS)

  • 강민구
    • 스마트미디어저널
    • /
    • 제3권2호
    • /
    • pp.37-42
    • /
    • 2014
  • 본 논문에서는 갑작스런 전력난이나 피크 전력시간 등의 비상 전력상황에서 필수적으로 동작해야 할 정보기기기가 전력을 공급받기 위해 우선순위(Priority) 제어기능을 부여한 스마트 플러그 기반의 스마트 콘센트에 의한 스마트 모니터링 및 표시장치를 갖는 스마트 미디어 플랫폼의 제어기능 설계를 제안한다. 이러한 스마트 게이트웨이는 에너지 저장장치(ESS, Energy Storage System)와 연동함으로서 스마트 플러그가 양방향 송배전과 우선순위 제어형 스마트 제어모듈에 의한 전력관리 효율을 극대화할 수 있다.