• Title/Summary/Keyword: Energy Standard

Search Result 3,190, Processing Time 0.034 seconds

Cooling Performance Evaluation study of Dual-Source Heat Pump System (2중열원 히트펌프시스템의 냉방성능예측에 관한 연구)

  • Noh, Kwan-Jong;Kim, Ji-Young;Kang, Eun-Chul;Park, Hye-Moon;Lee, Euy-Joon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • A steady-state simulation model for Dual-Source Heat Pump(DSHP) of 8RT was presented. A Dual-Source Heat Pump(DSHP) has been designed to make up for the conventional air source heat pumps. The performance evaluation has been conducted under internal standard test conditions such as ISO-13256-1 and KS C 9306. However, as test conditions such as entering water, indoor and outdoor air conditions could not be controlled to satisfy the standard test conditions in outdoor tests, a series of experiments have been conducted with the actual test conditions. Then, computer models for DSHP could be used for the standard condition have developed using EES program. The model was developed from basic thermodynamic principles and heat transfer relations. Most of the parameters were obtained with EES from the actual catalog data. The simulation results were in good agreement with the experiments.

  • PDF

Design Assessment and Certification Scheme of Tidal Energy Converters (조류발전설비 설계 평가 및 인증시스템)

  • Kim, Mikum;Kim, Manneung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.238.1-238.1
    • /
    • 2010
  • Researches and developments of tidal energy converters are close to commercialization stage. But, commercialization of tidal energy converters is not ready in korea. In Europe, many experts of company, laboratory and public institution involved in marine energy are active for commercialization of marine energy converters in European Marine Energy Centre. Furthermore, in IEC/TC114, standardization of technical standards for assessment and certification of tidal energy converters of each country is under discussion. Therefore, We have to prepare for commercialization, standardization and entry into the overseas market. In this study, trends of commercialization and standardization of international markets of marine energy converters are investigated and certification schemes of overseas are analyzed. We expect that this study will make contribution to establish the foundation of commercialization of tidal energy converters.

  • PDF

A Study on Fuzzy Control Method of Energy Saving for Activated Sludge Process in Sewage Treatment Plant (하수처리 활성오니공정의 에너지 절감을 위한 퍼지 제어 방법에 관한 연구)

  • Nahm, Eui-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1477-1485
    • /
    • 2018
  • There are two major issues for activated sludge process in sewage treatment plant. One is how to make sewage be more clean and the other is the energy saving in sewage treatment process. The major monitoring sewage qualities are chemical oxygen demand, phosphorus, nitrogen, suspended solid in effluent. These are transmitted to the national TMS(Telemetry Monitoring System) at every hour. If these exceed the environmental standard, the environmental charges imposed. So, these water qualities are to be controlled below the environmental standard in operation of sewage treatment plant. And recently, the energy saving is also important in process operation. Over 50% energy is consumed in blowers and motors for injection oxygen into aeration tank. So, with the water qualities to be controlled below the environmental standard, the energy saving also is to be accomplished for efficient plant management. Almost researches are aimed to control water quality without considering energy saving. AI techniques have been used for control water quality. AI modeling simulator provided the optimal control inputs(blower speed, waste sludge, return sludge) for control water quality. Blower speed is the main control input for activated sludge process. To make sewage be more clean, the excessive blower speed is supplied, but water quality is not better than the previous. In results, non necessary energy is consumed. In this paper we propose a new method that the energy saving also is to be accomplished with the water qualities to be controlled below the environmental standard for efficient plant management. Water qualities in only aeration tank are used the inputs of fuzzy models. Outputs of these models are chemical oxygen demand, phosphorus, nitrogen, suspended solid in effluent and have the environmental standards. In test, we found this method could save 10% energy than the previous methods.

Intercomparison and Determination of Trace Elements in Urban Dust by Neutron Activation Analysis (중성자방사화분석법을 이용한 대기분진중의 미량원소 비교분석)

  • Chung, Yong-Sam;Moon, Jong-Hwa;Kim, Sun-Ha;Park, Kwang-Won;Kang, Sang-Hun
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.179-188
    • /
    • 2000
  • Trace elements in air samples artificially loaded on filters with urban dust and the bulk material of urban dust as an environmental sample were determined non-destructively using instrumental neutron activation analysis. Standard reference material (Urban Dust, SRM 1648) of the National Institute of Standard and Technology was used for the analytical quality control. The relative error for 37 elements was less than 15% and the standard deviation was less than 10%. 29 elements in the urban dust and 21 elements in the loaded filter sample were determined respectively. To evaluate the proficiency and reliability of the measurement, data intercomparison was performed and 39 analytical laboratories participated in the analysis using different analytical methods; neutron activation analysis, particle induced X-ray emission analysis, X-ray fluorescence analysis and atomic absorption spectrometry. Z-scores were calculated using the standard deviation of the laboratorie's mean as target standard deviation, and a good result was obtained that the values fall between -1 and +1 except some elements.

  • PDF

The Hammer Energy Delivered to the Drilling Rod in the SPT 1 (표준관입시험시 롯드에 전달되는 해머의 낙하에너지 평가 1)

  • 조성민;정종홍;김동수;이우진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.469-476
    • /
    • 2001
  • The Ν-value in the standard penetration test(SPT) is affected by the magnitude of the rod penetration energy transmitted from the falling hammer as well as the geotechnical characteristics of the ground. Understanding of the striking energy efficiency in the SPT equipment is getting important for that reason. The energy efficiencies of the doughnut hammer with the hydraulic lift system and the automatic trip hammer system were investigated through field tests using the instrumented rod and wave-signal acquisition systems including the pile driving analyzer(PDA) . The rod energy ratio, ΕR$\_$r/ was defined as the ratio of the energy delivered to the drilling rod to the potential free-fall energy of the hammer. It appears that the type of the hammer and lift/drop system had a strong influence on the energy transfer mechanism and ΕR$\_$r/ also varies according to the energy instrumentation system and the analysis methods.

  • PDF

The Hammer Energy Delivered to the Drilling Rod in the SPT 2 (표준관입시험시 롯드에 전달되는 해머의 낙하에너지 평가 2)

  • 조성민;정종흥;이우진;김동수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.71-78
    • /
    • 2002
  • The N-value from the standard penetration test(SPT) is affected by the magnitude of the rod penetration energy transmitted from the falling hammer as well as the geotechnical characteristics of the ground. Understanding of the striking energy efficiency in the SPT equipment is getting important for that reason. The energy efficiencies of the various type of equipment were investigated through field tests using the instrumented rod and wave-signal acquisition systems including the pile driving analyzer(PDA). The rod energy ratio, ERr was defined as the ratio of the energy delivered to the drilling rod to the potential free-fall energy of the hammer. It appears that the type of the hammer and lift/drop system had a strong influence on the energy transfer mechanism and ERr also varies according to the energy instrumentation system and the analysis methods.

  • PDF

Cyclic Voltammetry Depending on the Electrode Connection Mode in Small-scale LCC Electrowinning System

  • Kim, Si Hyung;Kim, Taek-Jin;Kim, Gha-Young;Lee, Seul Gi;Jang, Junhyuk;Paek, Seungwoo;Lee, Hansoo;Eun, Hee-Chul;Lee, Sung-Jai;Ahn, Do-Hee
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2017.05a
    • /
    • pp.92-93
    • /
    • 2017
  • In this paper, CV behavior of electrowinning system was studied depending on the electrode connection mode of potentiostat. In this system, currents can be flown from electrodes to SUS parts because the LCC assembly was electrically connected between the SUS parts and electrolytic salt. Standard mode without ground line of multi tab or CE to ground mode is considered to be more reasonable than standard mode when using multi tab having ground line.

  • PDF

Improvement of accuracy in quantitative TXRF analysis of soil sample by applying external standard method (외부표준법을 적용한 토양시료의TXRF 정량분석 정확도 개선)

  • Park, Jinkyu;Park, Ranhee;Han, Sun Ho;Lim, Sang Ho;Lee, Chi Gyu;Song, Kyuseok
    • Analytical Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.261-268
    • /
    • 2016
  • TXRF is a powerful technique for the soil sample analysis due to its ability to conduct quantitative analysis of powder sample without complicated pre-treatment processes. The conventional internal standard method used for this technique suffers from relatively low accuracy because of varying matrix effects of soil. In order to improve the accuracy, external standard method was applied to analyze two types of soil samples; acid-dissolutionized soil solution and detergent-suspended soil powder. Individual ICP-AES/MS grade standards were mixed, diluted and measured to create standard curves, but applying these curves for analyzing the soil solution sample did not make any improvement in comparison with the internal standard method. On the other hand, standard curves were created with using standard soil powders for the analysis of soil powder samples, and we found that this method increased the accuracy significantly relative to the internal standard method. Especially, Al, Fe, K, Ca, Ti, Ba, Mn, Sr, Rb, Cu was measured with relatively high accuracy (relative error = ${\pm}20%$).

Introduction to the standard reference data of electron energy loss spectra and their database: eel.geri.re.kr

  • Jeong Eun Chae;Ji-Soo Kim;Sang-Yeol Nam;Min Su Kim;Jucheol Park
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.2.1-2.7
    • /
    • 2020
  • Electron energy loss spectroscopy (EELS) is an analytical technique that can provide the structural, physical and chemical information of materials. The EELS spectra can be obtained by combining with TEM at sub-nanometer spatial resolution. However, EELS spectral information can't be obtained easily because in order to interpret EELS spectra, we need to refer to and/or compare many reference data with each other. And in addition to that, we should consider the different experimental variables used to produce each data. Therefore, reliable and easily interpretable EELS standard reference data are needed. Our Electron Energy Loss Data Center (EELDC) has been designated as National Standard Electron Energy Loss Data Center No. 34 to develop EELS standard reference (SR) data and to play a role in dissemination and diffusion of the SR data to users. EELDC has developed and collected EEL SR data for the materials required by major industries and has a total of 82 EEL SR data. Also, we have created an online platform that provides a one-stop-place to help users interpret quickly EELS spectra and get various spectral information. In this paper, we introduce EEL SR data, the homepage of EELDC and how to use them.

The Policy Impact of Renewable Energy Subsidies on Solar PV: The Case of Renewable Portfolio Standard in Korea (국내 태양광 발전 보조금 제도의 정책 효과: 공급의무화제도 사례를 중심으로)

  • Kwon, Tae-Hyeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.1
    • /
    • pp.59-69
    • /
    • 2017
  • In 2012, Korea introduced a Renewable Portfolio Standard (RPS) scheme, replacing the Feed-in Tariff (FIT) scheme as a market support policy of renewable energy in the electricity market. RPS is to allocate obligatory quota of renewable energy sources for electricity suppliers, whereas FIT is to guarantee high prices for electricity from renewable energy sources. This study examines the effect of this policy change on solar photovoltaic market. According to the study, solar PV market grew fast under FIT as well as under RPS. However, under RPS the size of subsidy for solar PV suppliers was shrunk substantially. In addition, market risk increased severly under RPS due to the volatility of price of renewable energy certificate (REC) as well as of the electricity market price. The small and medium suppliers of solar PV were suffered the most severly from these policy effects. Therefore, the policy reform of RPS is needed to alleviate the market risk of small and medium suppliers of solar PV.