• Title/Summary/Keyword: Energy Standard

Search Result 3,150, Processing Time 0.03 seconds

Effect of Density Variation of High Tenacity PET Interlace Yarn on the Physical Properties of Pack Style Shock Energy Absorber (고강력 PET Interlace Yarn 밀도변화가 Pack Style Shock Energy Absorber의 물성에 미치는 영향)

  • Cho, Jin Won;Kwon, Sang Jun;Choe, Jong Deok;Kim, Sang Tae;Ji, Byung Chul;Yang, Seong Baek;Yeum, Jeong Hyun
    • Textile Coloration and Finishing
    • /
    • v.27 no.2
    • /
    • pp.132-141
    • /
    • 2015
  • Fall-arrest systems(maximum arrest force and allowable free-fall) have been widely applied to provide a safe stop during fall incidents for various industrial activities. Fabric structure affects on the mechanical properties of shock energy absorber. The object of this study is to perform the basic research for the evaluation of the capacity of fall arrest energy absorber in relation to the different interlace yarn density. In this work, pack style energy absorber was prepared by weaving 10 types(Interlace yarn density used high tenacity PET 1000D : 60, 59, 58, 57, 56, 55, 54, 53, 52, 51). The paper presents the results of theoretical investigations of the performance of adjustable absorber during fall arrest. Dynamic load tests based on the EU fall protection equipment standard(CE : EN355:2002) were conducted. Results showed that the maximum arrest force by dynamic load test of energy absorber was satisfied with global standard(below 6,000N). Also, Maximum allowable free-fall of energy absorber showed below 1.75m.

Comparative Evaluation of Various Standard Methods in Leaching Test of Radioactive Waste Form (방사성고화체로부터의 $^{60}$ Co, $^{137}$ Cs 침출에 대한 표준시험법의 상호비교)

  • Kim, Ki-Hong;Ryu, Young-Gerl;Chung, Kyung-Ki;Hong, Kwon-Pyo;Lee, Nak-Hee;Jeong, Yi-Yeong;Koh, Duck-Joon;Kim, Heon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.93-103
    • /
    • 2003
  • IAEA, FT-04-020, and ANS 16.1, standard leaching test methods, were evaluated comparatively with their test results. Leaching index of $^{60}$ Co and $^{137}$ Cs by ANS 16.1 method for waste forms of paraffin and cement were above 6.0. Their leaching behavior were depending on the type of matrix and leachant. Leachability of $^{60}$ Co for cement waste form was higher in simulated seawater than do-mineralized water, and was higher in de-mineralized water for paraffin waste form. leachability of $^{60}$ Co was contrary to $^{137}$ Cs. Cumulative fraction leached of $^{60}$ Co was higher in order or IAEA > ANS > FT in a cement waste form.

  • PDF

Coulometric Determination of Plutonium in PWR Spent Fuels (PWR 사용후핵연료내 플루토늄의 전기량적 정량)

  • Sohn, Se Chul;Suh, Moo Yul;Kim, Jung Suk;Song, Byung Chul;Jee, Kwang Yong;Choi,In Kyu;Kim, Won Ho
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.6
    • /
    • pp.581-586
    • /
    • 2000
  • Separation and coulometric titration method were applied for the determination of plutonium content in samples of PWR spent fuel. Plutonium was separated on an anion exchange(AG MP-1) column and determined by the controlled-potential coulometric titration. In this study, we discussed some experimental conditions related to the separation and determination of plutonium in PWR spent fuel samples. Average accuracy(recovery of plutonium) for the determination of 0.230∼3.02 mg plutonium standard was 99.36%. Average precision(relative standard deviation, RSD) for the determination of 0.250∼0.450 mg plutonium in PWR spent fuel samples was 0.38%.

  • PDF

An Energy Saving Protocol to Eliminate Overhearing Problem in Active RFID System (능동형 RFID 시스템에서 태그의 Overhearing을 제거하기 위한 에너지 절약 프로토콜)

  • Lee, Chae-Seok;Kim, Dong-Hyun;Kim, Jong-Deok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.1
    • /
    • pp.1-11
    • /
    • 2013
  • Reducing the energy that consumed by tag is a key requirement for the wider acceptance of the active RFID systems that use battery constrained tags. When the reader is not interrogating, the active RFID standard protocols try to reduce energy consumption of tags by using sleep mode. On sleep mode tags is active by receiving a specific signals from reader, until tag receive a sleep mode command from the reader, a tag waste energy for remaining in RX mode. Overhearing is a state of a tag in which it wastes energy for maintaining active RX state while there is no frame destined to it. According to our analysis, the amount of energy consumed by a tag due to overhearing is several time larger than that consumed by the effective communication. We propose RANO(Reservation Aloha for No Overhearing) that is designed to inform a tag of its effective communication intervals to eliminate overhearing problem in active RFID communication. The performance of the proposed protocol was evaluated through the real world by changing the number of tags and size of data. The result of an experiment, the proposed protocol performed saving about 22 times less than the standard protocol did.

Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

  • Lee, Seung Kyu;Chang, Insu;Kim, Sang In;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul;Kim, Min Chae
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.72-78
    • /
    • 2019
  • Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system, beam alignment as well as the verification of beam qualities was conducted. Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber. Results and Discussion: Beam alignment was performed in three steps, and collimators and other components were arranged to maintain the uniformity of the mean air kerma rate within ${\pm}2.5%$ at the effective beam diameter of 28 cm. The beam quality was verified by using half-value layer measurement methods specified by American National Standard Institute (ANSI) N13.11-2009 and International Organization for Standardization (ISO)-4037. For each of the nine beams than can be generated by the new X-ray irradiation system, air kerma rates for X-ray fields of different beam qualifies were measured. The results showed that each air kerma rate and homogeneity coefficient of the first and second half-value layers were within ${\pm}5%$ of the recommended values in the standard documents. Conclusion: The results showed that the new X-ray irradiation system provides beam qualities that are as high as moderate beam qualities offered by National Institute of Standards and Technology in ANSI N13.11-2009 and those for narrow-spectrum series of ISO-4037.

A Case Study on the Islanding Detection Protection of PV System and ESS System (태양광 발전과 ESS 시스템의 연계운전시 단독운전 방지 사례 연구)

  • Lim, Jong Rok;Hwang, Hye-Mi;Shin, Woo Gyun;Ju, Young-Chul;Jung, Young Seok;Kang, Gi-Hwan;Ko, Suk-Whan
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.1
    • /
    • pp.59-66
    • /
    • 2019
  • BIPV or BAPV installation applied to building is increasing through public utility mandates enterprise. Solar PV energy generates only during the day, but if it is operated in convergence with ESS, which stores electrical energy, it can restrain the fossil energy used in buildings throughout the day. A solution is to converge with PV system and ESS. However, PV systems and ESS connected to the power grid in parallel can cause problems of electrical stability. A study was conducted on the case of failure to detect islanding operation under the parallel operation of PV generation and ESS that are connected in parallel to power grid. Experiments conducted various non-islanding detections under the operating conditions. In the experiment results, when one PCS - PV inverter or ESS inverter - was operating under the islanding condition, it stopped working within 0.5 seconds of the Korean grid standard. However, when both of PV inverter and ESS inverter were operating at the same time under the islanding situation, the anti-islanding algorithm did not operate normally and both inverters continuously supplied power to the connected RLC loads. islanding detection Algorithm developed by each inverter manufacturer has caused this phenomenon. Therefore, this paper presented a new test standard for islanding detection.

Study on the Interaction of U(VI) Species With Natural Organic Matters in KURT Groundwater (KURT 지하수의 천연 유기물질과 6가 우라늄 화학종의 상호작용에 관한 연구)

  • Jung, Euo Chang;Baik, Min Hoon;Cho, Hye-Ryun;Kim, Hee-Kyung;Cha, Wansik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.2
    • /
    • pp.101-116
    • /
    • 2017
  • The interaction of U(VI) (hexavalent uranium) species with natural organic matter (NOM) in KURT (KAERI Underground Research Tunnel) groundwater is investigated using a laser spectroscopic technique. The luminescence spectra of the NOM are observed in the ultraviolet and blue wavelength regions by irradiating a laser beam at 266 nm in groundwater. The luminescence spectra of U(VI) species in groundwater containing uranium concentrations of $0.034-0.788mg{\cdot}L^{-1}$ are measured in the green-colored wavelength region. The luminescence characteristics (peak wavelengths and lifetime) of U(VI) in the groundwater agree well with those of $Ca_2UO_2(CO_3)_3(aq)$ in a standard solution prepared in a laboratory. The luminescence intensities of U(VI) in the groundwater are weaker than those of $Ca_2UO_2(CO_3)_3(aq)$ in the standard solution at the same uranium concentrations. The luminescence intensities of $Ca_2UO_2(CO_3)_3(aq)$ in the standard solution mixed with the groundwater are also weaker than those of $Ca_2UO_2(CO_3)_3(aq)$ in the standard solution at the same uranium concentrations. These results can be ascribed to calcium-U(VI)-carbonate species interacting with NOM and forming non-radiative U(VI) complexes in groundwater.

Risk assessment for Soil Contamination Warning Standard and Soil Background Concentration (토양오염 우려기준과 토양 자연배경농도에 대한 위해성평가)

  • Shin, Dong;Park, Seong-Jae;Jo, Young Tae;Bong, Jae-eun;Park, Jeong-Hun
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.3
    • /
    • pp.37-49
    • /
    • 2021
  • There is domestic Soil Contamination Warning Standard (SCWS) as remediation standard concentration of contaminated soils. No risk should be observed at soil concentration less than SCWS. Therefore, SCWS was evaluated to confirm the risk assessment. Background Concentration of Soil (BGC) and target remediation concentration were also assessed. The results show that Excess Cancer Risk (ECR) of SCWS was the highest in the groundwater intake pathway (Adult: 6.27E-04, Child: 2.81E-04). Total Cancer Risk (TCR) was 7.76E-04 and 4.30E-04 for adult and child, exceeding reference value (10-6). Hazard Quotient (Non-Carcinogenic Risk, HQ) was the highest in the indoor air inhalation pathway (Adult: 3.64E+03, Child: 8.74E+02). Hazard Index (Total Non-Carcinogenic Risk, HI) exceeded reference value 1. ECR of the BGC was the highest in the groundwater intake pathway (Adult: 1.71E-04, Child: 7.67E-05). TCR was 2.12E-04 for adults and 1.17E-04 for children, exceeding the reference value (10-6). HQ was the highest in groundwater intake pathway (Adult: 4.10E-01, Child: 1.84E-01). HI was lower than reference value 1 (Adult: 4.78E-01, Child: 2.50E-01). The heavy metal affecting ECR was Arsenic (As). The remediation-concentration of As was 7.14 mg/kg which is higher than BGC (6.83 mg/kg). TCR of As should be less than reference value (10-6), but it was higher for all of SCWS, BGC and target remediation concentration. Therefore, it is suggested that risk assessment factors should be re-evaluated to fit domestic environmental settings and SCWS should be induced to satisfy the risk assessment.

A Study on the Process of Energy Demand Prediction of Multi-Family Housing Complex in the Urban Planning Stage (공동주택단지의 개발계획단계 시 에너지 수요예측 프로세스에 관한 연구)

  • Mun, Sun-Hye;Huh, Jung-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.304-310
    • /
    • 2008
  • Currently energy use planning council system is mandatory especially for the urban development project planned on a specified scale or more. The goal of existing demand prediction was to calculate the maximum load by multiplying energy load per unit area by building size. The result of this method may be exaggerated and has a limit in the information of period load. The paper suggests a new forecasting process based on standard unit household in order to upgrade the limit in demand prediction method of multi-family housing complex. The new process was verified by comparing actual using amount of multi-family housing complex to forecasting value of energy use plan.

  • PDF

Energy Calibration for Neutron Capture Resonance of Natural Sm by Using 46-MeV Electron Linear Accelerator

  • Lee, Jae-Hong;Lee, Sam-Yol
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.2
    • /
    • pp.31-35
    • /
    • 2007
  • Energy calibration is important to identify accurate neutron capture resonance energy in the neutron TOF (Time-of-Flight) experiment. In present study, the accurate neutron capture resonance energies of natural Sm were measured by using a 46-MeV electron linear accelerator (linac) at the Research Reactor Institute, Kyoto University(KURRI). The BGO spectrometer were adopted for measurement the prompt capture gamma-ray of the sample. To obtain energy calibration curve, resonance energy of a gold sample used as standard resonance energy Mughabghab's data (From neutron resonance parameters data). Previous data (by Mughabghab) of natural Sm sample have been compared with the present result.

  • PDF