• Title/Summary/Keyword: Energy Standard

Search Result 3,150, Processing Time 0.03 seconds

A Cost Effective Energy Saving of Fluorescent Lighting in Commercial Buildings

  • Lee, Seong-Ryong;Nayar, Chemmangot V.
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.215-222
    • /
    • 2012
  • Lighting represents a significant component of commercial buildings, particularly office buildings. Fluorescent lighting is invariably used in all commercial, industrial and residential areas. A significant amount of lighting energy is wasted every day by leaving the lights on and not utilizing daylight energy. However, if daylight illuminance can be harnessed, this will reduce the electricity consumption of fluorescent lamps and save energy. This paper explains possible significant savings in lighting energy consumption and hence in costs, without reducing the performance and visual satisfaction in office or industrial buildings. It is proposed to obtain energy saving by reducing the supply voltage without degradation in lighting performance. Experimental results confirm that as much as 20% of electrical energy can be saved by reducing about 9% of the supply voltage, without noticeably affecting light output while complying with lighting standard limits.

Development of a Building Energy Demand Estimator (건물 단지에 대한 에너지 수요 예측 프로그램 개발)

  • Chung, Mo;Park, Hwa-Choon;Im, Yong-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.127-132
    • /
    • 2009
  • A Microsoft Access application program is developed to calculate energy demands for a Community Energy System (CES) composed of various types of buildings. The field-measured heating, hot water, cooling, and electricity energy consumptions for 14 types of building are systematically organized in forms of database and hourly loads for a span of year (8760 hours) are generated through an automated statistical procedure. User-friendly standard windows interfaces are provided to assist non-expert end users.

  • PDF

A Study on Standard Heating and Cooling Load according to Design Factors using Prototypical Load Model (표준부하모델을 이용한 설계 변수에 따른 표준부하량 분석)

  • Kim, Kwonye;Bae, Sangmu;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.1
    • /
    • pp.1-13
    • /
    • 2021
  • Before newly-built building and building remodeling, it is important to predict and analyze building energy performance through energy simulation programs. Nevertheless, simulation results widely vary depending on individual user experience and input values. Therefore, this study uses prototypical building model, a versatile tool in building energy modeling, simulation and research for researchers and policy-makers, and ASHRAE standards. Then, it analyzed the changes in design type (roof type, number of floors) for the base case. As the result, it was found that the gap of annual energy demand per between them is maximally 9.1%.

Intermediate indicators and sustainability of Renewable Fuel Standard (신재생 연료 혼합 의무화 제도(RFS)의 지속성과 중간지표)

  • Lee, Ah-Young;Koo, Ja-Kong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.1
    • /
    • pp.20-26
    • /
    • 2014
  • Interest in renewable fuel of recent has increased. Among them, From next year the government announced that it would enforce the RFS. Interest associated with it are concentrated. The RFS, for manufacturers of transportation fuels such as a vehicle, you are a renewable fuel a certain percentage of the fuel supplied. In other words, it refers to a system of mandatory to supply by mixing biofuels. Already in Europe, America and other developed countries to diversify energy sources and subjected Additionally there since ancient times for its rural development by introducing the RFS takes effect coming. Further and inspect to deal with climate change, which is performed via the RFS. Some even are represented by five axis of the sustainability of the RFS.

A Study on the Recognition of Green Standard for Energy and Environmental Design(G-SEED) from the Survey of Multi-complex Residents in Newtown (신도시 공동주택 거주자 대상의 녹색건축 인증제도 인식도 조사 및 분석)

  • Mok, Seon-Soo;Park, Ah-Reum;Cho, Dong-Woo
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.23-28
    • /
    • 2013
  • Green Standard for Energy and Environmental Design(G-SEED) has been used for environmental friendly building certification since 2002. The certification criteria initialed with multi-residential building and now it expands to 10 criteria for new and existing building types. The purpose of this study is to understand current recognition of G-SEED from the survey of multi-complex residences in newtown. From the general question, 75.2% of responders answered the period of living term between 1~3 years, 58.6% lived in $102.48{\sim}132.23m^2$ residential area and 65.2% owned their residences. The 43.2% of respondents recognized that their residences gained G-SEED certification by G-SEED emblem(31.6%). This is the significant meaning to understand public recognition of G-SEED and how to approach the strategy for raising the G-SEED recognition. The responders expected positive influence for economical value from G-SEED and also 75.3% of responders agreed with that G-SEED would be a decision make to buy and rent their residences. Second, residents responded that the consideration issue for green building is energy & prevention of environmental pollution(27.7%) which carries equal concern in G-SEED criteria category. The result of this survey verifies that the current level recognition of G-SEED of the responder's perspectives still is not well-known but it confirmed they have a positive expectation. Therefore, from this result, G-SEED needs to draw road map with detail plans for developing G-SEED with public participation.

Dietary Status of the Elderly from the Low Socioeconomic Group on the Suburbs of Jeonju - Focussed on Integration of Family Planning - (도시근교(都市近郊) 노년층(老年層)의 영양실태조사(營養實態調査) - 가족계획(家族計劃)을 통합(統合)하여 -)

  • Kim, In-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.9 no.1
    • /
    • pp.1-14
    • /
    • 1980
  • The purpose of this study was to assess dietary intake and food habits of low-income person aged 60 years or eldary. The hundred fifty persons from the suburbs of Jeonju were surveyed between August 1 to 20,1979. Results were as follows: Family environment Approximately 90% of elderly persons surved, lived with their children and grand-children: 5.2% together as a couple; and 4.4%, widowed, lived alone. Nearly 40% of the households has a average monthly incomes of W40,000 to W100,000. Average food expediture accounted for 50 to 70% of total monthly income, thus indicating that the subject families belonged to the lowest socioeconomic level. As pocket money, 74.5% of male subjects had more than W5,100 per month. whereas, 51.4% of female had less than W5,000. Anthropometric measurements: 97.6% of subjects has heights greater than 90% of the Korean standard for their age group, whereas 45.2% of the subjects were 60 to 89% of standard weight. 88% had an arm circumferences only 60 to 89% of the standard. Nutrient intake: Intake of the majority of nutrients was below the recommended allowances, especially for energy, protein, calcium and iron. The energy input ratio of carbohydrate: protein: fat was 73.1-80.9. 13.3-15.8: 4.5-11.5, showing very heavy dependence on carbohydrates for energy needs. The contribution of animal protein was 24.3% of total protein intake, indicating an improper protein diet. Other factors influenced on the nutrient intake: Poor teeth, illness, and poor appetite were always associated with inadequate intake of energy and nutrients. The larger the family size, the lesser intake of nutrients was observed among those elderly.

  • PDF

The Systematic Study on Reduction of Food Waste Products(II) -Estimation of One Serving Size of Frequently Consumed Korean Dishes - (음식물 쓰레기를 줄이기 위한 체계화 연구(II) -일부 한국음식의 1인 1회 적정 섭취량 평가-)

  • 전예숙;최미경
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.9 no.1
    • /
    • pp.64-73
    • /
    • 1999
  • The purpose of this study was to estimate the effect of serving sizes on dish wastes, nutrient intake, and diet satisfaction for reduction of dish waste products. The dish waste, energy and protein intake, and satisfaction scores before and after dining were compared in 44 subjects fed various serving sizes(100%, 90%, 80% of standard size) of 10 frequently consumed Korean dishes. The result are as follows: 1. Average age, height, and weight of 44 subjects were 30.5, 174.0cm, and 68.1kg in men and 26.2, 164.2cm, and 53.5kg in women, respectively. 2. There was a significant difference in the dish waste rate of 10 Korean dishes to serving sizes. The range of dish waste rates of 10 Korean dishes was 13.14-33.04%. 3. The average energy intake from 10 Korean dishes in which 100% of the standard serving size was served was lower than Korean RDA. Protein intakes from Sulungtang, Yukgaejang, Deunjang-ggigae, and Bibimpab with 100% servins size, Soondubi-ggigae 90% servins size, and Galbitang, Bulgogi-bakpan, Sangsungui-bakpan, Bakpan 80% of standard serving size were higher than Korean RDA. 4. The satisfaction score before dining on Sulungtang, Bulgogi-bakpan, Sangsungui-bakpan decreased with decreasing serving size. However, there was no significant difference in satisfaction score after dining to serving size. These findings indicate that dish waste rate and diet satisfaction of 10 these Korean dishes are fixed and energy intake is insufficient. Therefore, for reduction of food waste and reasonable serving size of dishes evaluated in this study, there should be more studies about Korean menu development with decreasing serving size and increasing energy density.

  • PDF

A Study on the Earthquake Safety Assessment of Energy Storage Facilities According to Climate Change (기후변화에 따른 에너지 저장시설 지진 안전성평가에 관한 연구)

  • Ham, Eun-Gu;Lee, Sung-Il
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.226-235
    • /
    • 2021
  • Purpose: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Method: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Result: In this study, by statically loading earthquake loads and evaluating the level of collapse prevention of special-class structures, facility managers can easily recognize and evaluate the risk level, and this analysis result can be applied to future facility risk management. Earthquake analysis was performed so that. Conclusion: As a result of analyzing the Coalescer facility according to the current design standard KBC2016, the stress ratio of the main supporting members was found to be up to 4.7%. Therefore, the members supporting Coalescer were interpreted as being safe against earthquakes with a reproducibility period of 2400 years that may occur in Korea.

Feasibility study of CdZnTe and CdZnTeSe based high energy X-ray detector using linear accelerator

  • Beomjun Park;Juyoung Ko;Jangwon Byun;Byungdo Park ;Man-Jong Lee ;Jeongho Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2797-2801
    • /
    • 2023
  • CdZnTeSe (CZTS) has attracted attention for applications in X- and gamma-ray detectors owing to its improved properties compared to those of CdZnTe (CZT). In this study, we grew and processed single crystals of CZT and CZTS using the Bridgeman method to confirm the feasibility of using a dosimeter for high-energy X-rays in radiotherapy. We evaluated their linearity and precision using the coefficient of determination (R2) and relative standard deviation (RSD). CZTS showed sufficient RSD values lower than 1.5% of the standard for X-ray dosimetry, whereas CZT's RSD values increased dramatically under some conditions. CZTS exhibited an R2 value of 0.9968 at 500 V/cm, whereas CZT has an R2 value of 0.9373 under the same conditions. The X-ray response of CZTS maintains its pulse shape at various dose rates, and its properties are improved by adding selenium to the CdTe matrix to lower the defect density and sub-grain boundaries. Thus, we validated that CZTS shows a better response than CZT to high-energy X-rays used for radiotherapy. Further, the applicability of an onboard imager, a high-energy X-ray (>6 MV) image, is presented. The proposed methodology and results can guide future advances in X-ray dose detection.

Effective Volume of the Korea Research Institute of Standards and Science Free Air Chamber L1 for Low-Energy X-Ray Measurement

  • Chul-Young Yi;Yun Ho Kim;Don Yeong Jeong
    • Progress in Medical Physics
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Purpose: To evaluate the effective volume of the Korea Research Institute of Standards and Science free air chamber (KRISS FAC) L1 used for the primary standard device of the low-energy X-ray air kerma. Methods: The mechanical dimensions were measured using a 3-dimensional coordinate measuring machine (3-d CMM, Model UMM 500, Carl Zeiss). The diameter of the diaphragm was measured by a ring gauge calibrator (Model KRISS-DM1, KRISS). The elongation of the collector length due to electric field distortion was determined from the capacitance measurement of the KRISS FAC considering the result of the finite element method (FEM) analysis using the code QuickField v6.4. Results: The measured length of the collector was 15.8003±0.0014 mm with a 68% confidence level (k=1). The aperture diameter of the diaphragm was 10.0021±0.0002 mm (k=1). The mechanical measurement volume of the KRISS FAC L1 was 1.2415±0.0006 cm3 (k=1). The elongated length of the collector due to the electric field distortion was 0.170±0.021 mm. Considering the elongated length, the effective measurement volume of the KRISS FAC L1 was 1.2548±0.0019 cm3(k=1). Conclusions: The effective volume of the KRISS FAC L1 was determined from the mechanically measured value by adding the elongated volume due to the electric field distortion in the FAC. The effective volume will replace the existing mechanically determined volume in establishing and maintaining the primary standard of the low-energy X-ray.