• 제목/요약/키워드: Energy Fluence

검색결과 154건 처리시간 0.031초

Spectrum analysis of acoustic Barkhausen noise on neutron irradiated material

  • Sim Cheul-Muu;Park Seung-Sik;Park Duck-Gum;Lee Chang-Hee
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2000년도 학술발표대회 논문집 제19권 2호
    • /
    • pp.231-234
    • /
    • 2000
  • In relation to a non-destructive evaluation of irradiation damage of micro-structure of interstitial, void and dislocation, the changes in the hysteresis loop and Barkhausen noise amplitude and the harmonics frequency due to neutron irradiation were measured and evaluated. The Mn-Mo-Ni low alloy steel of reactor pressure vessel was irradiated to a neutron fluence of $2.3\times10^{19}n/cm^2$ $(E\ge1MeV)$ at $288^{\circ}C.$The saturation magnetization of neutron irradiated metal did not change. Neutron irradiation caused the coercivity to increase, whereas susceptibility to decrease. The amplitude of Barkhausen noise parameters associated with the domain wall motion were decreased by neutron irradiation. The spectrum of Barkhausen noise was analyzed with an applied frequency of 4Hz and 8Hz, and a sampling time of 50 $\mu$ sec and 20 $\mu$ sec. The harmonic frequency of Joule effect shows 4Hz, 8Hz, 12Hz and 16Hz reflected from an unirradiated specimen. On the contrary, the harmonic frequency disappeared for the irradiated specimen. Harmonic frequency of induced voltage of sinusoidal magnetic field And Spectrum of Barkhausen noise on material is determined.

  • PDF

펄스 레이저 증착법에 의한 $(Pb_{0.72}La_{0.28})Ti_{0.93}O_3$ 박막의 제작 및 특성 (Fabrication and Characterization of$(Pb_{0.72}La_{0.28})Ti_{0.93}O_3$ Thin Films by Pulsed Laser Deposition)

  • 심경석;이상렬
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권5호
    • /
    • pp.303-308
    • /
    • 1999
  • Dielectric thin films of PLT(28) ($(Pb_{0.72}La_{0.28})Ti_{0.93}O_3$) have been deposited on $Pt/Ti/SiO_2/Si$ substrates in situ by a laser ablation. We have systematically changed the laser fluence from 0.4 J/$cm^2$ to 3 J/$cm^2$, and deposition temperature from $450^{\circ}C\; to\; 700^{\circ}C$. The surface morphology was changed from planar grain structure to columnar structure as the nucleation energy was increased. The PLT thin film with columnar structure showed good dielectric properties. The deposition temperature influenced on nucleation energy much stronger than the laser energy density did.

  • PDF

The Development of Gamma Energy Identifying Algorithm for Compact Radiation Sensors Using Stepwise Refinement Technique

  • Yoo, Hyunjun;Kim, Yewon;Kim, Hyunduk;Yi, Yun;Cho, Gyuseong
    • Journal of Radiation Protection and Research
    • /
    • 제42권2호
    • /
    • pp.91-97
    • /
    • 2017
  • Background: A gamma energy identifying algorithm using spectral decomposition combined with smoothing method was suggested to confirm the existence of the artificial radio isotopes. The algorithm is composed by original pattern recognition method and smoothing method to enhance the performance to identify gamma energy of radiation sensors that have low energy resolution. Materials and Methods: The gamma energy identifying algorithm for the compact radiation sensor is a three-step of refinement process. Firstly, the magnitude set is calculated by the original spectral decomposition. Secondly, the magnitude of modeling error in the magnitude set is reduced by the smoothing method. Thirdly, the expected gamma energy is finally decided based on the enhanced magnitude set as a result of the spectral decomposition with the smoothing method. The algorithm was optimized for the designed radiation sensor composed of a CsI (Tl) scintillator and a silicon pin diode. Results and Discussion: The two performance parameters used to estimate the algorithm are the accuracy of expected gamma energy and the number of repeated calculations. The original gamma energy was accurately identified with the single energy of gamma radiation by adapting this modeling error reduction method. Also the average error decreased by half with the multi energies of gamma radiation in comparison to the original spectral decomposition. In addition, the number of repeated calculations also decreased by half even in low fluence conditions under $10^4$ ($/0.09cm^2$ of the scintillator surface). Conclusion: Through the development of this algorithm, we have confirmed the possibility of developing a product that can identify artificial radionuclides nearby using inexpensive radiation sensors that are easy to use by the public. Therefore, it can contribute to reduce the anxiety of the public exposure by determining the presence of artificial radionuclides in the vicinity.

고에너지 양성자에 의해 결함을 증가시킨 그래핀 소자의 전기적 특성 변화 연구 (High-energy Proton Irradiated Few Layer Graphene Devices)

  • 김홍렬;김지현
    • Korean Chemical Engineering Research
    • /
    • 제49권3호
    • /
    • pp.297-300
    • /
    • 2011
  • Mechanical exfoliation 방법에 의해 제작된 그래핀(Few Layer Graphene: FLG) 소자에 양성자를 조사하여 의도적으로 결함의 수를 증가시켰다. 그 후 공기중에 노출되었을 때와 진공상태에서 보관한 후에 측정된 전기적 특성을 확인하였다. 또한 UV에 노출시킨 후와 진공상태에서 열처리를 진행한 후에 전기적 특성의 변화들을 관찰하였다. 진공상태에서 보관한 그래핀 소자는 표면에 흡착되어 도펀트로 작용하게되는 species의 수가 감소하기 때문에 전류가 감소하는 결과를 나타내었다. UV에 노출된 상태에서는 오존에 의한 영향으로 약간의 전류 상승이 일어나지만 케리어의 이동도가 감소하게 된다. 반면 진공상태에서 열처리 후에는 전류는 매우 감소하게 되지만 결함과 도펀트에 의한 케리어 산란 현상이 감소하게 되므로 이동도는 크게 증가하게 된다.

구법(灸法)과 intense pulsed light(IPL)의 특성 비교 및 광선구(光線灸)의 한방임상(韓方臨床) 활용(活用) (Comparison between Moxibustion and the Intense Pulsed Light (IPL) and the Clinical Application of Photo-moxa)

  • 장인수;선승호;남동현;금수연;서형식
    • 한방안이비인후피부과학회지
    • /
    • 제23권3호
    • /
    • pp.78-83
    • /
    • 2010
  • Objectives : The purpose of this study is to compare the principles between moxibustion and the 'Intense pulsed light (IPL)' and to investigate the clinical application of the photo-moxa for the Korean medicine fields. Methods : The characteristics of moxibustion, IPL, parabolic reflector moxa and the dermatology surgical use of moxibustion were reviewed in the literature. Results : IPL is one type of light treatments that is employed by radiating the short-pulse wave, which is transformed from the light of high intensity. There has been used parabolic reflector in Asia for more than 2,000 years, and this hand-held device used for moxibustion in traditional medicine. Moxibustion is one of the treatment tools in Korean medicine using the heat energy. The fluence or energy density of IPL in clinical circumstances is similar to parabolic reflector moxa of moxibustion. IPL and parabolic reflector moxa shared same treatment principle employing the heat energy. Therefore IPL could apply for many indications in Korean medicine as a moxibustion tool and acupuncture. Conclusions: IPL may be plausible to be a fascinate method in phototherapy of Korean medicine.

Machine learning modeling of irradiation embrittlement in low alloy steel of nuclear power plants

  • Lee, Gyeong-Geun;Kim, Min-Chul;Lee, Bong-Sang
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4022-4032
    • /
    • 2021
  • In this study, machine learning (ML) techniques were used to model surveillance test data of nuclear power plants from an international database of the ASTM E10.02 committee. Regression modeling was conducted using various techniques, including Cubist, XGBoost, and a support vector machine. The root mean square deviation of each ML model for the baseline dataset was less than that of the ASTM E900-15 nonlinear regression model. With respect to the interpolation, the ML methods provided excellent predictions with relatively few computations when applied to the given data range. The effect of the explanatory variables on the transition temperature shift (TTS) for the ML methods was analyzed, and the trends were slightly different from those for the ASTM E900-15 model. ML methods showed some weakness in the extrapolation of the fluence in comparison to the ASTM E900-15, while the Cubist method achieved an extrapolation to a certain extent. To achieve a more reliable prediction of the TTS, it was confirmed that advanced techniques should be considered for extrapolation when applying ML modeling.

IRRADIATION DEVICE FOR IRRADIATION TESTING OF COATED PARTICLE FUEL AT HANARO

  • Kim, Bong Goo;Park, Sung Jae;Hong, Sung Taek;Lee, Byung Chul;Jeong, Kyung-Chai;Kim, Yeon-Ku;Kim, Woong Ki;Lee, Young Woo;Cho, Moon Sung;Kim, Yong Wan
    • Nuclear Engineering and Technology
    • /
    • 제45권7호
    • /
    • pp.941-950
    • /
    • 2013
  • The Korean Nuclear-Hydrogen Technology Development (NHTD) Plan will be performing irradiation testing of coated particle fuel at HANARO to support the development of VHTR in Korea. This testing will be carried out to demonstrate and qualify TRISO-coated particle fuel for use in VHTR. The testing will be irradiated in an inert gas atmosphere without on-line temperature monitoring and control combined with on-line fission product monitoring of the sweep gas. The irradiation device contains two test rods, one has nine fuel compacts and the other five compacts and eight graphite specimens. Each compact contains about 260 TRISO-coated particles. The irradiation device is being loaded and irradiated into the OR5 hole of the in HANARO core from August 2013. The device will be operated for about 150 effective full-power days at a peak temperature of about $1030^{\circ}C$ in BOC (Beginning of Cycle) during irradiation testing. After a peak burn-up of about 4 atomic percentage and a peak fast neutron fluence of about $1.7{\times}10^{21}\;n/cm^2$, PIE (Post-Irradiation Examination) of the irradiated coated particle fuel will be performed at IMEF (Irradiated Material Examination Facility). This paper reviews the design of test rod and irradiation device for coated particle fuel, and discusses the technical results for irradiation testing at HANARO.

시분해 레이저 유도 백열법을 이용한 매연 입자 크기에 관한 수치적 연구 (Numerical Investigation on Soot Primary Particle Size Using Time Resolved Laser Induced Incandescence (TIRE-LII))

  • 이종호;김정용;정동수;장영준;전충환
    • 대한기계학회논문집B
    • /
    • 제29권9호
    • /
    • pp.1022-1031
    • /
    • 2005
  • Temporal behavior of the laser induced incandescence (LII) signal is often used for soot particle sizing, which is possible because the cooling behavior of a laser heated particle is dependent on the particle size. In present study, LII signals of soot particles are modeled using two non-linear coupled differential equations deduced from the energy- and mass-balance of the process. The objective of this study is to obtain an appropriate calibration curve for determining primary particle size by comparing the gated signal ratio and double-exponential curve fitting methods. Not only the effects of laser fluence and gas temperature on the cooling behavior but also heat transfer mechanisms of heated soot particle have been investigated. The second-order exponential curve fitting showed better agreements with the LII signals than the gated signal ratio method which was based on the lust-order exponential curve fit. And the temporal decay rate of the LII signal and primary particle size showed nearly linear relationship, which was little dependent on the laser fluence. And it also could be reconfirmed that vaporization was dominant process of heat loss during first loons after laser pulse, then heat conduction played most important role while thermal radiation had little influence all the time.

Properties of Water Substitute Solid Phantoms for Electron Dosimetry

  • Saitoh, Hidetoshi;Tomaru, Teizo;Fujisaki, Tatsuya;Abe, Shinji;Myojoyama, Atsushi;Fukuda, Kenichi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.255-259
    • /
    • 2002
  • To reduce the uncertainty in the calibration of radiation beams, absorbed dose to water for high energy electrons is recommended as the standards and reference absorbed dose by AAPM Report no.51 and IAEA Technical Reports no.398. In these recommendations, water is, defined as the reference medium, however, the water substitute solid phantoms are discouraged. Nevertheless, when accurate chamber positioning in water is not possible, or when no waterproof chamber is available, their use is permitted at beam qualities R$\_$50/ < 4 g/cm$^2$ (E$\_$0/ < 10 MeV). For the electron dosimetry using solid phantom, a depth-scaling factor is used for the conversion of depth in solid phantoms to depth in water, and a fluence-scaling factor is used for the conversion of ionization chamber reading in plastic phantom to reading in water. In this work, the properties, especially depth-scaling factors c$\_$p1/ and fluence-scaling factors h$\_$pl/ of several commercially available water substitute solid phantoms were determined, and the electron dosimetry using these scaling method was evaluated. As a result, it is obviously that dose-distribution in solid phantom can be converted to appropriate dose-distribution in water by means of IAEA depth-scaling.

  • PDF

ITO, PR, 격벽 재료의 레이저 직접 미세가공

  • 이천;이경철;안민영;이홍규
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.80-80
    • /
    • 1999
  • 플라즈마 디스플레이 패널(PDP)의 공정을 간단히 하기 위하여 포토레지스트, ITO, 격벽재료를 Ar+ laser(λ-514 nm, CW)와 Nd:YAG laser(λ=532, 266nm, pulse)로 직접 패터닝 하였다. 레이저에 의한 포토레지스트의 패턴결과, 아르곤 이온 레이저의 포토레지스트 가공의 반응 메카니즘은 레이저 빔의 열에 의한 시료 표면의 국부적인 온도상승에 의한 용융작용이며, 그 결과 식각 후 형성된 패턴의 단면 모양도 레이저빔의 profile과 같은 가우시안 형태를 나타낸다. Nd:YAG 레이저의 4고조파(532nm)를 이용한 경우 200$\mu\textrm{m}$/sce의 주사속도에서 포토레지스트를 패턴하기 위한 임계에너지(threshold energy fluence) 값은 25J/cm2이며, 약 40J/cm2의 에너지 밀도에서 하부기판의 손상이 발생하기 시작하였다. 글미 1은 Nd:YAG 레이저 4고조파를 이용하여 포토레지스트를 식각한 경우 SEM 표면사진(위)과 단차특정기에 의한 단면형상(아래)이다. ITO 막의 레이저에 의한 직접 패턴 결과, ITO 막은 레이저 펄스에 의한 급속 가열 및 증발에 의한 메커니즘으로 식각이 이루어지며, 레이저 파장에 따른 광흡수 정도의 차이에 의해 2고조파 (532nm)에서 ITO 막의 가공 품질이 4고조파(266nm)에 비해 우수하며 패턴의 폭도 출력에 따라 제어가 용이하였다. 그림 2는 Nd:YAG 레이저 2고조파를 이용하여 ITO를 식각한 경우 SEM표면 사진(위)과 단차측정기에 의한 단면형상(아래)이다. 격벽 재료의 레이저에 의한 직접 패턴 결과, Ar+ 레이저(514nm)는 출력 밀도 32NW/cm2에서 격벽을 유리 기판의 경계면까지 식각하였다. Nd:YAG 레이저(532nm)는 laser fluence가 6.5mJ/cm2에서 격벽을 식각하기 시작하였으며, 19.5J/cm2에서 유리기판의 rudraus(격벽 두께 130$\mu\textrm{m}$)까지 식각하였다.

  • PDF