• Title/Summary/Keyword: Energy Efficiency Measure

Search Result 242, Processing Time 0.026 seconds

Three Dimension Angle Change of the Trunk to the Muscular Endurance during a Prolonged Running (오래 달리기 시 하지 근지구력에 따른 몸통의 3차원 각 변화)

  • Kim, Tae-Sam;Lee, Yeon-Jong
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.61-73
    • /
    • 2007
  • The purpose of this study was to investigate the influence of the muscular endurance on the kinematic factors during a prolonged run. Subjects, 12 males, who were divided into three groups(lower group, general group, and in higher group) after measuring the lower limb's muscular endurance previously. They were asked toe run on the treadmill at 7.4km/h of speed. To analyze the kinematics parameters of the trunk during running, the ProReflex MCU Camera(Qualisys, Sweden) were used. All parameters were sampled from 5 minute, 40 minute, and 60 minute moments during running. An ANOVA with Repeated Measure was used to test the statistic significance between and within groups for all parameters determined with SPSS 11.0. Significance was defined as p<.05. The conclusions were as follows; There was significantly difference within(lapse of running time) groups in the take-off and minimum knee angle event of swing phase of the trunk flexion and extension. In conclusion, the muscular endurance affected on movement of the trunk during a prolonged run. In addition, it showed that there was significant difference in the energy consumption by lapse of running time. Therefore, it seems to be relationships between the muscular endurance and running efficiency.

Disinfection of Water by Ultrasonic Irradiation (초음파 검사에 의한 수중의 살균처리)

  • 손종렬;유병성
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.1
    • /
    • pp.54-61
    • /
    • 1999
  • The industrial techniques of ultrasound have been used in the various fields, such as cleaning, medical surgery, emulsification, cell disruption etc. Especially the application of cell disruption was interested in the field of disinfection process in water by ultrasonic irradiation. It has been recognized that the ultrasounds are irradiated in aqueous solution, cavitation bubbles are generated and shock waves of high temperature and pressure are emitted as the bubbles are developed and finally broken, which function as a energy source to promote reaction efficiencies of various kinds of chemical reactions such as disinfection reaction in water. Therefore, this study was performed to apply the ultrasound for the disinfection method of infected drinking raw water and to discuss the limiting factors such as pH, sample volume and reaction temperature influenced on the removal efficiency of E. coli from experimental analysis of the results obtained in bench-scale plant. For the experiments to measure the influence of reaction parameters in the ultrasonic disinfection process, escalated reactivity of aqueous solutions was excellent when pH in aqueous solution was low, and sample volume was small. On the contrary, the reactivity of disinfection became elevated when reaction temperature was high. It was found that the rate constant of disinfection reaction was applied by Chick's law, reaction kinetics of Chick's law was irreversible and pseudo-first order at all the tested conditions.As a conclusion it appeared that the technology using ultrasonic irradiation can be applied to the treatment of disinfection in infected water which are difficult to be treated by conventional methods.

  • PDF

Numerical Analysis of the Effect of Injection Pressure Variation on Free Spray and Impaction Spray Characteristics

  • Park, Kweon-Ha;Kim, Byung-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.236-250
    • /
    • 2000
  • Compression ignition direct injection diesel engines employed a high pressure injection system have been developed as a measure to improve a fuel efficiency and reduce harmful emissions. In order to understand the effects of the pressure variation, many experimental works have been done, however there are many difficulties to get data in engine condition. This work gives numerical results for the high pressure effects on spray characteristics in wide or limited space with near walls. The gas phase is modelled by Eulerian continuum conservation equations of mass, momentum, energy and fuel vapour fraction. The liquid phase is modelled using the discrete droplet model approach in Lagrangian form and the drop behavior on a wall is calculated with a new droplet-wall interaction model based on the experiments observing individual drops. The droplet distributions, vapour fractions and gas flows are shown in various injection pressure cases. In free spray case which the injection spray has no wall impaction, the spray dispersion and vapour fraction increase and drop sizes decrease with increasing injection pressure. The same phenomena appears more clearly in wall impaction cases.

  • PDF

Magnetic Measurement of PLS Storage Ring Prototype Dipole Magnet (방사광 가속기용 2극 전자석 특성측정 및 보정)

  • 강봉구;박기현;윤종렬;구양모
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.2
    • /
    • pp.163-168
    • /
    • 1992
  • Results of magnetic measurement of a prototype Storage Ring dipole magnet for the Pohang Light Source (PLS) are summarized. Hall probe mapping and rotating coil methods are used to measure field profiles and integrated field properties. End chamfering experiments are performed on the as-built magnet, which has four removable pole-end pieces, to meet the specifications set from beam dy-namics requirement. The corrected magnet has efficiency of 99.7% at 2.0 GeV excitation ad higher order multipole error levels less than the specifications for all excitations, showing that the magnet has appropriate properties for the PLS Storage Ring.

  • PDF

Design and Implementation of a DSP-Based Multi-Channel Power Measurement System

  • Jeon Jeong-Chay;Oh Hun
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.214-220
    • /
    • 2005
  • In order to improve energy efficiency and solve power disturbances, power components measurement for both the supply and demand side of a power system must be implemented before appropriate action on the power problems can be taken. This paper presents a DSP (Digital Signal Processor)-based multi-channel (voltage 8-channel and current 10-channel) power measurement system that can simultaneously measure and analyze power components for both supply and demand. Voltage 8-channel and current 10-channel measurement is made through voltage and current sensors connected to the developed system, and power components such as reactive power, power factor and harmonics are calculated and measured by the DSP. The measured data are stored in a personal computer (PC) and a commercial program is then used for measurement data analysis and display. After voltage and current measurement accuracy revision using YOKOGAWA 2558, the developed system was tested using a programmable ac power source. The test results showed the accuracy of the developed system to be about 0.3 percent. Also, a simultaneous measurement field test of the developed system was implemented by application to the supply and demand side of the three-phase power system.

Development of several hundred kV Air Core pulse transformer (수백 kV급 공심형 펄스 변압기 개발)

  • Kim, S.C.;Park, S.S.;Kim, S.H.;Heo, H.;Nam, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2132-2135
    • /
    • 2005
  • Cylindrical type air core pulse transformers capable of passing high voltage and energy pulse waveforms with high efficiency and low distortion require a much more delicate design balance of physical dimensions and electrical parameters than iron or ferrite core units. The structure of an air core high voltage pulse transformer is relatively simple, but considerable attention is needed to prevent breakdown between transformer windings. Since the thickness of the windings in spiral type is on the order of sub-millimeter, field enhancement at the edge of the windings is very high. It is, therefore, important to find proper electrical insulation Parameter to make the system compact. Several shapes of the winding are considered for air core pulse transformer development. In this paper, we are described design procedure, parameters measure and experiment results of air core type HV pulse transformer.

  • PDF

Manufacturing Activated Carbon from Rice Shell or Saw Dust and Their Adsorption Performance for the Surfactants (왕겨 및 톱밥을 이용한 활성탄 제조 및 계면활성제 흡착성능)

  • KIM, T.Y.;Baek, I.H.;Yun, Y.G.;Jeong, N.H.;Nam, K.D.
    • Journal of the Korean Applied Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.79-90
    • /
    • 1998
  • One of the objectives of this study were to develop a process for manufacturing activated carbons from agricultural by-products(rice shells and saw dust) and another is to measure the iodine number, ash content and removal ratio of COD. The other is to compare those values with those of commercialized activated carbons. Agricultural by-products based activated carbons were manufactured through the steam-reaction method. A rotary kiln type furnace was used for both carbonization and activation. The optimum operating temperatures for carbonization and activation were $650^{\circ}C$ and $900^{\circ}C$, respectively. For the activated carbons produced under these conditions, the iodine number was 1,127mg/g. Especially, removal efficiency of COD was 61.5% for 40mg/L of wastewater and 30% for 150mg/L of SLS(Sodium Lauryl Sulfate).

Numerical Analysis of Heat Transfer Characteristics of Cooling System for 2.3 kW EV Battery Pack (2.3 kW급 전기자동차 배터리팩용 냉각 장치의 열전달 특성에 관한 해석적 연구)

  • Seong, Dong-Min;Park, Yong-Seok;Sung, Hong-Seok;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.6
    • /
    • pp.44-49
    • /
    • 2022
  • The improvement in the battery performance and life using a battery thermal management system directly affects the improvement in the performance, life, and energy efficiency of electric vehicles. Therefore, this study numerically analyzed the heat exchange processes between the coolant inside the cooling plate channel and the heat generated by the battery. The cooling performance was analyzed based on the average temperature, temperature uniformity, and the maximum and minimum temperature differences of the battery. A performance difference existed depending on the coolant inlet temperature but showed the same tendency of cooling performance according to the shape of each plate's channel. Type 1 showed the best results in terms of battery temperature uniformity, which is the most important measure of battery performance; Type 2 showed the best results in terms of the average temperature of the battery; and Type 3 showed the best results in terms of the maximum and minimum temperature differences of the battery compared with that of the other cooling plates.

Key Management Framework based on Double Hash Chain for Secure Smart Grid Environments (안전한 스마트 그리드 환경을 위한 이중 해쉬 체인 기반 키 관리 프레임워크)

  • Lee, Young-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.9
    • /
    • pp.2063-2072
    • /
    • 2013
  • Smart Grid is the next-generation intelligent power grid that maximizes energy efficiency with the convergence of IT technologies and the existing power grid. It enables consumers to check power rates in real time for active power consumption. It also enables suppliers to measure their expected power generation load, which stabilizes the operation of the power system. However, there are high possibility that various kinds of security threats such as data exposure, data theft, and privacy invasion may occur in interactive communication with intelligent devices. Therefore, to establish a secure environment for responding to such security threat with the smart grid, the key management technique, which is the core of the development of a security mechanism, is required. Using a hash chain, this paper suggests a group key management mechanism that is efficiently applicable to the smart grid environment with its hierarchical structure, and analyzes the security and efficiency of the suggested group key management framework.

Development of EIS Evaluation Method about PEMFC 1kW STACK (가정용 연료전지 스택의 EIS 평가 기법 개발)

  • Park, Chaneom;Han, Woonki;Jung, Jinsu;Ko, Wonsik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.100.1-100.1
    • /
    • 2011
  • Electrochemical impedance spectroscopy(EIS) are using widely as a useful technique mainly in the field of electrochemical for the analysis of electrode reactions or characteristics of the composites. The response analysis of the systems technique provides comprehensive informations about the characteristic and structure of complex and internal reaction. The EIS is the method to measure impedance of the measurement target classified by the frequency, it select the equivalent impedance model to give same response from the result and it calculate the parameter. Therefore, the chemical reaction inside the fuel cell is to modeling to electrical impedance. And as repeating the same experiment in each of the operating point, we can get each different parameter. As a result, we can establish the equivalent impedance model in each operating point. Therefore, if we use these models, we can evaluate the fuel cell without the internal design parameter of the fuel cell as required in existing modeling. The EIS is used typically technique for distinguish status of fuel cell called SOH(State Of Health). When the fuel cell is degradation, Efficiency and health of the fuel cell is reduced because internal impedance is increase. As usage of these principles, we can evaluate state of fuel cell through the impedance analysis of fuel cells. In this study, we are presents EIS distinction system and algorithm for residential fuel cell systems. At the time of the fuel cell installation in the fields, the EIS system and proposed algorithm will be able to apply as technique for efficiency and performance evaluation about fuel cell system.

  • PDF