• Title/Summary/Keyword: Energy(EMS)

Search Result 191, Processing Time 0.038 seconds

A Simulation Study on Effect Analysis of EMS Combined Control of Central Cooling and Heating System (중앙냉난방시스템의 EMS 복합제어 효과 분석에 관한 시뮬레이션 연구)

  • Jae-Yeob Song;Byung-Cheon Ahn
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.4
    • /
    • pp.33-44
    • /
    • 2022
  • In this study, we analyze the existing heating and cooling operation method for an office-type complex building with a central heating and cooling system, and examine the effects of applying various EMS that can be applied according to the load size to save energy in the building. For this purpose, simulation analysis was performed. As a control method, reset control of chilled water, hot water, cooling water and supply air temperatures, optimal start/stop of heat source, and number of heat source control were applied according to the load size, and energy consumption was analyzed accordingly. In addition, when all of these control methods were applied, the overlapping energy saving effect was finally confirmed. As a result, it was possible to confirm the energy saving effect when EMS for reset control and heat source control were applied compared to the existing control method of the heating and cooling system, and the effect for the case of using all these control methods in combination was also confirmed.

Application of Energy Storage System for Industrial Customer (산업용 수용가의 에너지저장장치 적용)

  • Hong, Jong-seok;Chai, Hui-seok;Kang, Byoung-wook;Kim, Tae-hyeong;Kim, Jae-chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.992-998
    • /
    • 2015
  • The ESS is composed of Battery Package, PCS(Power Conditioning System) Package, BCU(BESS Control Unit). In Jeju smart grid test-bed, we have developed a business model by ESS power system, renewable energy, transportation, such as customers, and have demonstrated above things. We have analyzed the EMS(Energy Management System) model of KPX where manages supply and demand of domestic electrical power system. We modified and launched EMS for microgrid but the cost was expensive and the system was large size. For releasing this system from industry as a whole, it is imperative to develop PMS(Power Management System) for microgrid. However, the cost of EMS for microgrid is expensive, some systems because it is a large development of the all of the first fruits in urgent PMS(Power Management System) for microgrid to be used in industry in general. Therefore, in this paper, we propose the ESS model considering the power systems characteristics and extensibility in korea. and also we propose the PMS to manage the ESS systems.

Load Forecasting using Hierarchical Clustering Method for Building (계층적 군집분석방법을 활용한 건물 부하의 전력수요예측)

  • Hwang, Hye-Mi;Lee, Sung-Hee;Park, Jong-Bae;Park, Yong-Gi;Son, Sung-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • In recent years, energy supply cases to take advantage of EMS(Energy Management System) are increasing according to high interest of energy efficiency. The important factor for essential and economical EMS operation is the supply and demand plan the hourly power demand of building load using the hierarchical clustering method of variety statistical techniques, and use the real historical data of target load. Also the estimated results of study are obtained the reliability through separate tests of validity.

Implementation and Verification Analysis of Micro-EMS for Controlling EES (EES 제어를 위한 Micro-EMS 구현 및 실증 분석)

  • Kim, Kwang-Ho;Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.1
    • /
    • pp.155-161
    • /
    • 2015
  • The energy storage system is actively used as the widespread of smart grid. In the case of large scale EES, it can be efficiently controlled linked with BEMS or BAS. But, in the case of EES installed in a small sized household, it needs the help of the remote control system because it lacks the expert for controlling and operating of EES. In addition, in the case when the solar energy generation and EES are installed at the same time, a small sized EMS which can be efficiently controlled depending on the solar energy generation or electric power load is needed. In this paper, the EMS which can efficiently control the solar power generation as well as EES installed in a small sized household is implemented and its usefulness is verified through some experimental studies.

Development Plan of Korean-EMS (전력거래소의 한국형EMS 개발 계획)

  • Lee, Jin-Su;Yi, Myoung-Hee;Lee, Hyo-Sang;Kim, Sung-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.408-409
    • /
    • 2007
  • 한국전력거래소는 2005년 11월부터 한국형EMS(K-EMS; Korean Energy Management System) 개발을 추진 중에 있다. 2010년 10월까지 5년간에 걸쳐 3단계로 개발이 진행되는데 Baseline EMS, Prototype EMS 및 Fullscale EMS가 순차적으로 개발되게 된다. 본 논문에서는 한국형EMS 개발의 전반적인 개발 계획에 대해서 기술하고자 한다.

  • PDF

Automatic Syncronization Method and Development of the Dispatcher Operating system for EMS (EMS를 위한 급전원 운영 시스템의 자동동기 방법 및 개발)

  • Yun, Jang-Hyeok;Lee, Seung-Ju;Kong, Shin-Jo;Jang, Seung-Hwan;Lee, Seok-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.581-582
    • /
    • 2015
  • Energy management system (EMS)는 전력시스템에서 운영자에 의해 발전과 송전의 성능을 감시, 제어, 그리고 성능 최적화를 위하여 운영하는 시스템이다. 본 연구에서는 차세대 EMS(Next Generation Energy Management System : NG-EMS)에서 클라이언트 운영 시스템의 자동 동기 방법을 제안한다. 인트라넷 네트워크 망에서 클라이언트 운영 시스템의 효율적인 유지 보수를 위해 운영 소프트웨어 패치 및 엔지니어링을 통해 만들어진 그래픽 화면을 여러 클라이언트에 자동 동기 및 갱신 기능을 특징으로 한다. 또한 자동 동기 빌더를 이용하여 클라이언트에 동기 할 항목을 패키징하는 기능을 포함한다. 본 연구의 구성에 의해 자동 동기 서버 측에서 클라이언트의 동기 및 갱신주기를 효율적으로 관리하다. 클라이언트가 메인으로 접속하여 자동동기 상태를 체크하는 서버에 문제가 발생했을 경우 다중 동기 서버 형태로 운영하여 만일에 발생할 문제에 효율적으로 대처가 가능하다.

  • PDF

Application of the SCGE Assay for Detecting Induced DNA Damage in Plant Leaves

  • Kim, Jin Kyu;Song, Hi Sup;Kim, Do Young;Gichner, Tomas
    • Proceedings of the Korea Society of Environmental Biology Conference
    • /
    • 2003.11a
    • /
    • pp.68-73
    • /
    • 2003
  • The possibility of using the alkaline protocol of the single cell gel electrophoresis (SCGE) assay as a method for detecting induced DNA damage has been studied for six major plants. The EMS was applied as a model genotoxic agent on young excised leaves of the tested crops for 18 h at 26$^{\circ}C$ in the dark. With increasing concentrations of 0 to 10 mM EMS, the DNA damage, expressed by the averaged median tail moment values, significantly increased in nuclei of all plants studied. As the results, no correlation between the diameter of nuclei and sensitivity to EMS treatment was observed. The data obtained demonstrate the feasibility of using the SCGE assay for detecting induced DNA damage in plants.

  • PDF

EMS 메모리 데이터베이스 동기화 기능 개선 개발

  • Kim, Tae-Seop;Kwak, Jong-Kab;Lee, Seok-Chan
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.1131-1133
    • /
    • 2015
  • EMS(Energy Management System)는 우리나라 전체 전력 계통을 실시간으로 감시, 제어하고 계통 주파수를 자동으로 조정하여 성능 최적화를 유도하는 시스템으로 전력 계통의 두뇌와 같은 역할을 한다. 본 연구에서는 차세대 EMS(Next Generation Energy Management System: NG-EMS)에서 Enable과 Standby 서버 간 데이터베이스 동기화 기능 개선 개발 기술을 소개한다. EMS는 원방제어감시에 사용되는 SCADA(Supervisory Control And Data Acquisition) 데이터를 포함하여 자동발전, 경제급전 등의 전력 계통을 위해 가공된 데이터를 메모리 데이터베이스에 저장한다. 본 연구에서는 EMS의 메모리 데이터베이스에 저장되어 있는 데이터를 시스템 운영자가 선별을 하여 동기화를 수행할 수 있도록 한다. 또한 동기화 되고 있는 현황을 가시적으로 보임으로써 Enable 서버의 장애 발생 시 Standby 서버로의 대체가 유연하고 안정적이며, 신뢰성을 줄 수 있다.

An improvement and application for EMS RTU configuration method in K-water hydropower plants (수력발전소 EMS RTU 구성방식 개선 적용)

  • Kim, Yong-Hwan;Lee, Gyeong-Bae;Ka, Pil-Sun;Lee, Sung-Woo;Kim, Jong-Gyeum
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.770-771
    • /
    • 2011
  • 발전사업자는 한국전력거래소(KPX)의 급전지령을 원활히 수행하기 위해 EMS(Energy Management System) RTU를 설치하고 있다. 한국수자원공사는 수력발전소에 전기판넬 형식의 EMS RTU 대신 컴퓨터 기반의 가상(Virtual) EMS RTU를 설치하여 기존의 RTU방식에 비하여 설비 면적을 대폭 줄였으며, 설비 변동에 따른 감시제어 데이터의 수정시 하드웨어적인 작업을 소프트웨어적으로 간단하게 처리할 수 있다. 그래서 가상 EMS RTU는 발전통합운영시스템(GIOS)을 실시간으로 운영, 감시하여 장애를 신속히 복구함으로써 중앙급전소 발전기 원격운전 응답 특성을 향상시켜 전력계통의 안정적인 운영에 크게 기여하고 있다.

  • PDF