• Title/Summary/Keyword: Endovascular stent

Search Result 158, Processing Time 0.023 seconds

Amaurosis Fugax Associated with Stenosis of the Intracranial Internal Carotid Artery : Successful Restoration of Ophthalmic Artery Flow by Stent Placement

  • Lee, Chang-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.1
    • /
    • pp.28-30
    • /
    • 2006
  • Two patients presented with amaurosis fugax[AMF]. despite treatment with antiplatelet drugs and anticoagulants due to previous transient ischemic attacks. Angiography demonstrated severe stenosis in the cavernous and petrous internal carotid artery[ICA] respectively, with reduced flow in the ophthalmic artery[OA]. Endovascular stent placement in both patients resulted in normalization of the vessel lumen of the stenotic vessel segments. In addition, complete restoration of OA flow was noted immediately after stenting. Both patients showed no further episode of AMF over a follow-up period of 38 and 23 months respectively. Our clinical and angiographic findings suggest that hemodynamic Insufficiency in retinal vasculature caused by a stenosis of the cavernous or petrous ICA can be treated successfully by endovascular stent.

Treatment of Internal Carotid Artery Dissections with Endovascular Stent Placement: Report of Two Cases

  • Deok Hee Lee;Seung Ho Hur;Hyeon Gak Kim;Seung Mun Jung;Dae Sik Ryu;Man Soo Park
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.52-56
    • /
    • 2001
  • Extracranial carotid artery dissection may manifest as arterial stenosis or occlusion, or as dissecting aneurysm formation. Anticoagulation and/or antiplatelet therapy is the first-line treatment, but because it is effective and less invasive than other procedures, endovascular treatment of carotid artery dissection has recently attracted interest. We encountered two consecutive cases of trauma-related extracranial internal carotid artery dissection, one in the suprabulbar portion and one in the subpetrosal portion. We managed the patient with suprabulbar dissection using a self-expandable metallic stent and managed the patient with subpetrosal dissection using a balloon-expandable metallic stent. In both patients the dissecting aneurysm disappeared, and at follow-up improved luminal patency was observed.

  • PDF

Simple Coiling versus Stent-Assisted Coiling of Paraclinoid Aneurysms : Radiological Outcome in a Single Center Study

  • Kim, Soo Yeon;Park, Dong Sun;Park, Hye Yin;Chun, Young Il;Moon, Chang Taek;Roh, Hong Gee
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.644-653
    • /
    • 2017
  • Objective : Paraclinoid aneurysms are a group of aneurysms arising at the distal internal carotid artery. Due to a high incidence of small, wide-necked aneurysms in this zone, it is often challenging to achieve complete occlusion when solely using detachable coils, thus stent placement is often required. In the present study, we aimed to investigate the effect of stent placement in endovascular treatment of paraclinoid aneurysms. Methods : Data of 98 paraclinoid aneurysms treated by endovascular approach in our center from August 2005 to June 2016 were retrospectively reviewed. They were divided into two groups : simple coiling and stent-assisted coiling. Differences in the recurrence and progressive occlusion between the two groups were mainly analyzed. The recurrence was defined as more than one grade worsening according to Raymond-Roy Classification or major recanalization that is large enough to permit retreatment in the follow-up study compared to the immediate post-operative results. Results : Complete occlusion was achieved immediately after endovascular treatment in eight out of 37 patients (21.6%) in the stent-assisted group and 18 out of 61 (29.5%) in the simple coiling group. In the follow-up imaging studies, the recurrence rate was lower in the stent-assisted group (one out of 37, 2.7%) compared to the simple coiling group (13 out of 61, 21.3%) (p=0.011). Multivariate logistic regression model showed lower recurrence rate in the stent-assisted group than the simple coiling group (odds ratio [OR] 0.051, 95% confidence interval [CI] 0.005-0.527). Furthermore there was also a significant difference in the rate of progressive occlusion between the stent-assisted group (16 out of 29 patients, 55.2%) and the simple coiling group (10 out of 43 patients, 23.3%) (p=0.006). The stent-assisted group also exhibited a higher rate of progressive occlusion than the simple coiling group in the multivariate logistic regression model (OR 3.208, 95% CI 1.106-9.302). Conclusion : Use of stents results in good prognosis not only by reducing the recurrence rate but also by increasing the rate of progressive occlusion in wide-necked paraclinoid aneurysms. Stent-assisted coil embolization can be an important treatment strategy for paraclinoid aneurysms when considering the superiority of long term outcome.

Comparison of Long-Term Angiographic Results of Wide-Necked Intracranial Aneurysms : Endovascular Treatment with Single-Microcatheter Coiling, Double-Microcatheter Coiling, and Stent-Assisted Coiling

  • Kim, Hyun Sik;Cho, Byung Moon;Yoo, Chan Jong;Choi, Dae Han;Hyun, Dong Keun;Shim, Yu Shik;Song, Joon Ho;Oh, Jae Keun;Ahn, Jun Hyong;Kim, Ji Hee;Chang, In Bok
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.751-762
    • /
    • 2021
  • Objective : Endovascular treatment of intracranial aneurysms is challenging in case of wide-necked aneurysms because coils are prone to herniate into the parent artery, causing thromboembolic events or vessel occlusion. This study aims to compare long-term angiographic results of wide-necked aneurysms treated by stent-assisted, double-microcatheter, or single-microcatheter groups. Methods : Between January 2003 and October 2016, 108 aneurysms that were treated with endovascular coil embolization with a neck size wider than 4 mm and a follow-up period of more than 3 years were selected. We performed coil embolization with single-microcatheter, double-microcatheter, and stent-assisted techniques. Angiographic results were evaluated using the Raymond-Roy occlusion classification (RROC). All medical and angiographic records were reviewed retrospectively. Results : Clinical and angiographic analyses were conducted in 108 wide-necked aneurysms. The immediate post-procedural results revealed RROC class I (complete occlusion) in 66 cases (61.1%), class II (residual neck) in 36 cases (33.3%), and class III (residual sac) in six cases (5.6%). The final follow-up results revealed class I in 48 cases (44.4%), class II in 49 cases (45.4%), and class III in 11 cases (10.2%). Of a total of 45 (41.6%) radiologic recurrences, there were 21 cases (19.4%) of major recurrence that required additional treatment, and 24 cases (22.2%) of minor recurrence. The final follow-up angiographic results showed statistically significant differences between the stent-assisted group and the others (p<0.01). Conclusion : Long-term follow-up angiography demonstrated that the stent-assisted technique had a better complete occlusion rate than the other two techniques.

Long-Term Outcomes of Placement of a Single Transverse Stent through the Anterior Communicating Artery via the Nondominant A1 in Coil Embolization of Wide-Necked Anterior Communicating Artery Aneurysms

  • Ban, Seung Pil;Kwon, O-Ki;Kim, Young Deok
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.1
    • /
    • pp.40-48
    • /
    • 2022
  • Objective : Placement of a single transverse stent via the nondominant A1 across the anterior communicating artery (AComA) into the contralateral A2 can provide sufficient neck coverage for wide-necked bifurcation AComA aneurysms. The authors described the feasibility, safety and long-term outcomes of this technique. Methods : Between January 2015 and February 2018, placement of a single transverse stent via the nondominant A1 was attempted in 17 wide-necked bifurcation AComA aneurysms. The authors reviewed the medical records and radiological studies. Results : The technical success rate was 94.1% (16/17). Periprocedural thromboembolic complications occurred in one patient (6.3%) without permanent neurological deficits. The mean clinical follow-up duration was 39.9±9.8 months. No deaths or delayed thromboembolic complications occurred. The mean angiographic follow-up duration was 38.9±9.8 months. The immediate and final follow-up complete occlusion rates were 87.4 and 93.7%, respectively. There was no recanalization during the follow-up period. Conclusion : Placement of a single transverse stent via the nondominant A1 across the AComA into the contralateral A2 is a feasible and relatively safe endovascular technique for the treatment of wide-necked bifurcation AComA aneurysms, with good long-term occlusion rates and a reasonable complication rate, if only the nondominant A1 is applicable.

Covered Stents for the Endovascular Treatment of a Direct Carotid Cavernous Fistula : Single Center Experiences with 10 Cases

  • Li, Ke;Cho, Young Dae;Kim, Kang Min;Kang, Hyun-Seung;Kim, Jeong Eun;Han, Moon Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.1
    • /
    • pp.12-18
    • /
    • 2015
  • Objective : Covered stent has been recently reported as an effective alternative treatment for direct carotid cavernous fistulas (DCCFs). The purpose of this study is to describe our experiences with the treatment of DCCF with covered stents and to evaluate whether a covered stent has a potential to be used as the first choice in selected cases. Methods : From February 2009 through July 2013, 10 patients underwent covered stent placement for a DCCF occlusion. Clinical and angiographic data were retrospectively reviewed. Results : Covered stent placement was performed for five patients primarily as the first choice and in the other five as an alternative option. Access and deployment of a covered stent was successful in all patients (100%) and total occlusion of the fistula was achieved in nine (90%). Complete occlusion immediately after the procedure was obtained in five patients (50%). Endoleak persisted in five patients and the fistulae were found to be completely occluded by one month control angiography in four. The other patient underwent additional coil embolization by a transvenous approach. Balloon inflation-related arterial dissection during the procedure was noted in two cases; healing was noted at follow-up angiography. One patient suffered an asymptomatic internal carotid artery occlusion noted seven months post-treatment. Conclusion : Although endoleak is currently a common roadblock, our experience demonstrates that a covered stent has the potential to be used as the first choice in DCCF; this potential is likely to increase as experience with this device accumulates and the materials continue to improve.

Types of Thromboembolic Complications in Coil Embolization for Intracerebral Aneurysms and Management

  • Kim, Hong-Ki;Hwang, Sung-Kyun;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.3
    • /
    • pp.226-231
    • /
    • 2009
  • Objective : We describe our clinical experiences and outcomes in patients who had thromboembolic complications occurring during endovascular treatment of intracerebral aneurysms with a review of the literature. The types of thromboembolic complications were divided and the treatment modalities for each type were described. Methods : Between August 2004 and March 2009 we performed endovascular embolization with Guglielmi detachable coils for 173 patients with 189 cerebral aneurysms, including ruptured and unruptured aneurysms at our hospital. Sixty-eight patients were males and 105 patients were females. The age of patients ranged from 22-82 years (average, 58.8 years). We retrospectively evaluated this group with regard to complication rates and outcomes. The types of thromboembolic complications were classified into the following three categories: mechanical obstruction, distal embolic stroke, and stent-induced complications, which corresponded to types I, II, and III, respectively. A comparison of the clinical results was made for each type of complication. Results : Only eight patients had a thromboembolic complication during or after a procedure (4.6%). Of the eight patients, two had a mechanical obstruction as the causative factor; the other three patients had distal embolic stroke as the causative factor. The remaining three patients had stent-induced complications. In cases of mechanical obstruction, recanalization occurred due to the use of intra-arterial thrombolytic agents in one of two patients. Nevertheless, a poor prognosis was seen. In the cases of stent-induced complications, in one of three patients in whom a thrombus developed following stent insertion, a middle cerebral artery territory infarct developed with a poor prognosis despite the use of wiring and an intra-arterial thrombolytic agent. In the cases of distal embolic stroke, all three patients achieved good results following the use of antiplatelet agents. Conclusion : Treatment for thromboemboic complications due to mechanical obstruction and stent-induced complications include antiplatelet and intra-arterial thrombolytic agents; however, this cannot guarantee a sufficient extent of effectiveness. Therefore, active treatments, such as balloon angioplasty, stent insertion, and clot extraction, are helpful.

Mid-Term Results of Using the Seal Thoracic Stent Graft in Cases of Aortopathy: A Single-Institution Experience

  • Cho, Jun Woo;Jang, Jae Seok;Lee, Chul Ho;Hwang, Sun Hyun
    • Journal of Chest Surgery
    • /
    • v.52 no.5
    • /
    • pp.335-341
    • /
    • 2019
  • Background: The endovascular approach to aortic disease treatment has been increasingly utilized in the past 2 decades. This study aimed to determine the long-term results of using the Seal thoracic stent graft. Methods: We retrospectively reviewed the outcomes of patients who underwent thoracic endovascular aortic repair or a hybrid procedure using the Seal thoracic stent graft (S&G Biotech, Seongnam, Korea) from January 2008 to July 2018 at a single institution. We investigated in-hospital mortality and the incidence of postoperative complications. We also investigated the mid-term survival rate and incidence of aorta-related complications. Results: Among 72 patients with stent grafts, 15 patients underwent the hybrid procedure and 21 underwent emergency surgery. The mean follow-up period was $37.86{\pm}30.73$ months (range, 0-124 months). Five patients (6.9%) died within 30 days. Two patients developed cerebrovascular accidents. Spinal cord injury occurred in 2 patients. Postoperative renal failure, postoperative extracorporeal membrane oxygenation support, and pneumonia were reported in 3, 1, and 6 patients, respectively. Stent-related aortic complications were observed in 5 patients (6.8%). The 1- and 5-year survival and freedom from stent-induced aortic event rates were 81.5% and 58.7%, and 97.0% and 89.1%, respectively. Conclusion: The use of the Seal thoracic stent graft yielded good mid-term results. Further studies are needed to examine the long-term outcomes of this device.

Retrograde Aortic Dissection after Thoracic Endovascular Aortic Repair for Descending Aorta - 2 case reports- (하행 대동맥 내 스텐트-도관 삽입 후 발생한 역행성 대동맥 박리 - 2예 보고 -)

  • Hong, Soon-Chang;Kim, Jung-Hwan;Lee, Hee-Jeong;Youn, Young-Nam
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.758-763
    • /
    • 2010
  • In current era, thoracic endovascular aortic repair (TEVAR) has gained popularity. But, it bears the risk of serious complications such as treatment failure from endoleak, retrograde aortic dissection caused by injury of aortic wall at landing zone, or aortic rupture resulting from stent graft infection. We report two cases of surgical repair of retrograde aortic dissection after TAVAR applied to acute Stanford type B aortic dissection or traumatic aortic disruption.

Retrieval of a dislodged and dismounted coronary stent; using a rendezvous and snare technique at the brachial artery level via femoral approach

  • Jeong, Min-Woong;Sohn, Chang-Bae;Kim, Su Hong;Park, Jong-Ik;Park, Se-Ryeong;Min, Jun-Sik
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.2
    • /
    • pp.138-141
    • /
    • 2016
  • Coronary stent dislodgement during percutaneous coronary intervention, which occurs when the stent is passed through tortuous and calcified lesions, is not a rare complication. Without proper treatment, such as fixing with another stent in the coronary artery or removing the undeployed stent from the coronary artery or systemic artery system, this complication can cause serious problems. We experienced the unusual situation of a dismounted and dislodged coronary stent, in which retrograde retrieval to the radial artery was impossible during transradial coronary intervention. We report on use of a rendezvous and snare technique at the brachial artery level via femoral puncture, which resulted in resolution without surgery.