• Title/Summary/Keyword: End Effects

Search Result 3,661, Processing Time 0.036 seconds

A Study on the Effect of Dimensional Errors and Roundness in High Speed Cylindrical Machining Al-alloy (Al합금의 고속 원통가공에서 발생하는 치수오차와 진원도의 영향 고찰)

  • 윤종학;서성원;이헌철
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.5
    • /
    • pp.17-24
    • /
    • 2001
  • Recently, the requirements for high precision and efficiency machining are gradually increased to raise international competitiveness at the industrial fields of die and molds. This trend had made effects on the industrial fields in Korea and which needs fur studying of high precision and efficiency machining. This study is to investigate the effects of the non-out of end mill in the external cylindrical machining operated by solid carbide end mills with Al-alloy in high speed machining center relating to high spindle revolution and frost fred per minute on the dimensional precision, roundness of workpiece. From the results of experimentations followings are obtained; when Al-alloy is processed by the external cylindrical cutting of end milling through the high speed revolution, if the spindle revolution is higher relating to radial depth of cut, feed per tooth in very lower situation, finally, productivity can be raised because high precision and quality products are machined high efficiently.

  • PDF

Effects of Mesh Planes on Signal Integrity in Glass Ceramic Packages for High-Performance Servers

  • Choi, Jinwoo;Altabella Lazzi, Dulce M.;Becker, Wiren D.
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.2
    • /
    • pp.35-50
    • /
    • 2013
  • This paper discusses effects of mesh planes on signal integrity in high-speed glass ceramic packages. One of serious signal integrity issues in high-speed glass ceramic packages is high far-end (FE) noise coupling between signal interconnects. Based on signal integrity analysis, a methodology is presented for reducing far-end noise coupling between signal interconnects in high-speed glass ceramic modules. This methodology employing power/ground mesh planes with alternating spacing and a via-connected coplanar-type shield (VCS) structure is suggested to minimize far-end noise coupling between signal lines in high-speed glass ceramic packages. Optimized interconnect structure based on this methodology has demonstrated that the saturated far-end noise coupling of a typical interconnect structure in glass ceramic modules could be reduced significantly by 73.3 %.

Precision Machining Characteristics in Ball-end Milling of Sculptured Surfaces (볼 엔드밀에 의한 자유곡면의 정밀가공특성)

  • 김병희
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.1
    • /
    • pp.78-87
    • /
    • 2001
  • This paper deals with the study on the cutting characteristics in ball-end milling process. First of all, the effects of the geometric cutting conditions such as the cutting speed, feedrates and the path interval on the surface integrity were evaluat-ed by the analytical and the experimental approaches. Secondly, the cutting mechanism model was developed to predict the cutting force accurately. It is possible for the proposed model to predict the shape error, estimate system stability and build the reliable adaptive control system. A large amount of experimental set are performed to show the validities of the proposed theories and to investigate the effect of cutting geometry such as rubbing effects, burr effects and etc.

  • PDF

Detent Force Analysis in Permanent Magnet Linear Synchronous Motor Considering Longitudinal End Effects

  • Li, Liyi;Ma, Mingna;Chan, C.C.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.1
    • /
    • pp.9-15
    • /
    • 2013
  • This paper presents a uniform analytical model by energy method and Fourier series expansion to analyze detent force in uneven magnetic field for permanent magnet linear synchronous motor (PMLSM). The model reveals that detent force in long-primary type is mainly influenced by non-ideal distribution of permanent magnet magnetic motive force, while nounified air-gap permeance makes a great impact on detent force of short-primary type. Hence, magnetic field similarity of motor design techniques referring rotary counterpart are adopted. For long-primary type novel method of splitting edge magnets is proposed to reduce end effects force, and optimal widths of edge tooth in short-primary type also verify the effectiveness of magnetic field similarity. The experimental results validate finite element analysis results.

과업의 불확실성이 최종사용자컴퓨팅 특성과 최종사용자의 만족도에 미치는 영향

  • 김창기;이진주
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1993.04a
    • /
    • pp.329-338
    • /
    • 1993
  • The main objective of this paper is analyzing the effects of task uncertainty on EUC characteristics and end user satisfaction. Task uncertainty were identified as an important determinant of EUC characteristics. And the moderating effect of task uncertainty on the relationship between EUC characteristics and end user satisfaction was suggested. A field study was undertaken to test the hypothesized relationships among task uncertainty, EUC characteristics, and end user satisfaction Data were collected from 138 end-user of 19 Korean business organizations. The empirical results indicated that task uncertainty was significantly related to EUC characteristics and that task uncertainty had significant effect on the relationship between EUC characteristics and end user satisfaction. Implications and future research directions are drawn for the management of EUC and for further research on EUC.

  • PDF

Drained End Shield Effects on Heat Deposition Rate Distribution in CANDU 6 Reactor End Shield Structure

  • Jin, Yung-Kwon;Kim, Kyo-Youn;Hwang, Hae-Ryong
    • Nuclear Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.570-577
    • /
    • 1994
  • The loss of water in the carbon steel balls and water region of the end shield for CANDU 6 reactor could lead to significant temperature gradient through the end shield structure which amy result in the excessive deformation. With an assumed end shield drained scenario, the heat deposition rates were calculated through the end shield associated with the central fuel channel during full power operation as an initial step to thermal stress analysis. The drained case was compared with that of water present normal case in therms of heat deposition rater and the total heating throughout the end shield regions. The compared results show that the heat deposition and the total heating remain almost the same between the two cases. It was found that the change of volume integrated flux in the end shield regions due to the loss of water contribute a negligible effect on the heat deposition in this region.

  • PDF

A study on the characteristic of the anodic dead-end mode PEM fuelcell and performance improvement by pulsation effect (수소 데드 앤드 연료전지의 특성 및 맥동을 이용한 성능 향상에 관한 실험적 연구)

  • Choi, Jong-Won;Hwang, Yong-Sheen;Kim, Sung-Il;Ha, Jeong-Hoon;Park, Joon-Ho;Cha, Suk-Won;Kim, Min-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.336-340
    • /
    • 2009
  • This paper presents experimental results carried out on the purge characteristic of the anodic dead-end mode fuelcell and how to improve the cell performance by pulsation effects. The dead-end mode fuelcell has some merits that a fuel supplying device is not needed and the cell power is higher than that in the open mode fuelcell. However, the purge is necessary for preventing the porous media from being flooded by liquid water formed in the channel. At this time, the un-reacted fuel is discharged with the liquid water together in purge process. The discharged fuel can make the fuel efficiency lower. Therefore, the number of purge times should be decreased for the better fuel efficiency. In this study, the outlet of the anode channel was equipped with a purge solenoid valve and a pulsation generator. The purge times was decreased when the current density decreased and operation pressure increased without the pulsation effects. In addition, when the pulsation effects such as various frequencies or amplitudes were applied, purge times was alleviated up to 40%.

  • PDF

The Wall Shear Rate Distribution Near an End-to-End Anastomosis : Effects of Graft Compliance and Size

  • Rhee, Kye-Han
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.41-47
    • /
    • 2003
  • The patency rates of small diameter vascular grafts are disappointing because of the formation of thrombus and intimal hyperplasia. Among the various factors influencing the success of graft surgery, the compliance and the size of a graft are believed to be the most important physical properties of a vascular graft. Mismatch of compliance and size between an artery and a graft alters anastomotic flow characteristics, which may affect the formation of intimal hyperplasia. Among the hemodynamic factors influencing the development of intimal hyperplasia, the wall shear stress is suspected as the most important one. The wall shear stress distributions are experimentally measured near the end-to-end anastomosis models in order to clarify the effects of compliance and diameter mismatch on the hemodynamics near the anastomosis. The effects of radial wall motion, diameter mismatch and impedance phase angle on the wall shear rate distributions near the anastomosis are considered. Compliance mismatch generates both different radial wall motion and instantaneous diameter mismatch between the arterial portion and the graft portion during a flow cycle. Mismatch in diameter seems to be affecting the wall shear rate distribution more significantly compared to radial wall motion. The impedance phase angle also affects the wall shear rate distribution.

  • PDF

Effects of anesthesia on echocardiograms in myocardial infarcted dogs (심근경색 유발견에서 마취가 심초음파에 미치는 영향)

  • Yoon, Jung-hee;Sung, Jai-ki
    • Korean Journal of Veterinary Research
    • /
    • v.37 no.3
    • /
    • pp.669-685
    • /
    • 1997
  • The present study was performed to evaluate the effects of xylazine and tiletamine + zolazepam on echocardiograms before and after experimental myocardial infarctions in clinically normal dogs taken preliminary examinations related to cardiac function. The results are as follows. With xylazine administration, left ventricle end-diastolic dimension, left ventricle end-systolic dimension, left atrium/aorta, ejection time and velocity of circumferential fiber shortening increased and mitral valve CD slope, % delta D decreased(p<0.01). In tiletamine+zolazepam administered group, interventricular septum amplitude(p<0.01), mitral valve DE slope(p<0.05) and ejection time(p<0.01) decreased and left atrium/aorta, ejection time also decreased compared with xylazine group(p<0.01). In 48 hours after experimental myocardial infarction group, anterior aortic wall amplitude decreased compared with control, xylazine, tiletamine + zolazepam group, respectively(p<0.01). Posterior aortic wall amplitude decreased compared with control(p<0.01). Left ventricle end systolic dimension increased compared with control and tiletamine + zolazepam group, respectively(p<0.01). Left ventricular posterior wall end systolic dimension decreased compared with control(p<0.01). Left ventricular posterior wall amplitude decreased compared with control and tiletamine+zolazepam group(p<0.01). Left atrium/aorta decreased compared with xylazine group(p<0.01). % thickening left ventricular posterior wall decreased compared with control(p<0.05). % delta D decreased compared with control and tiletamine+zolazepam group(p<0.01). Ejection time decreased compared with xylazine(p<0.01). Velocity of circumferential fiber shortening increased compared with control and tiletamine + zolazepam group(p<0.01). With xylazine administration 48 hours after experimental myocardial infarction, anterior aortic wall amplitude, posterior aortic wall amplitude decreased compared with control(p<0.01). Left ventricle end-diastolic dimension increased compared with control(p<0.01). Left ventricle end-systolic dimension increased compared with control and tiletamine + zolazepam group, respectively(p<0.01). Left ventricular posterior wall end-systolic dimension and left ventricular posterior wall end-diastolic dimension decreased compared with control(p<0.01). Left atrium/aorta decreased compared with xylazine group(p<0.01). % thickening left ventricular posterior. wall(p<0.05) and % delta D(p<0.01) decreased compared with control. Velocity of circumferential fiber shortening increased compared with tiletamine + zolazepam group(p<0.01). With tiletamine + zolazepam administration 48 hours after experimental myocardial infarction, anterior aortic wall amplitude decreased compared with control, xylazine and tiletamine+zolazepam group, respectively(p<0.01). Posterior aortic wall amplitude decreased compared with control(p<0.01). Left ventricle end-systolic dimension increased compared with control and tiletamine+zolazepam group(p<0.01). Left ventricular posterior wall end-systolic dimension, left ventricular posterior wall end-diastolic dimension and interventricular septum amplitude decreased compared with control(p<0.01). Left atrium/aorta decreased compared with xylazine group(p<0.01). % delta D decreased compared with control and tiletamine + zolazepam group(p<0.01). Ejection time decreased compared with xylazine group and velocity of circumferential fiber shortening increased compared withtiletamine+zolazepam group(p<0.01). Conclusively, echocardiography was proved to be a useful, diagnostic, non-invasive and simple method for establishing the diagnosis of myocardial infarction and evaluating the effects of drug on cardiac function before and after myocardial infarction.

  • PDF

Development of Tube End-forming Process using Roll Die (롤다이를 이용한 튜브 축관공정 개발)

  • Kim, Yeong-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.4
    • /
    • pp.121-126
    • /
    • 2011
  • An accumulator placed on the refrigerant cycle pipe lines is a part to relax fluctuations of pressure within the pipe lines and stabilize refrigerants flowed into pipe. The accumulator has been mainly manufactured by the process of tube spinning using CNC(Computer Numerical Control) lathe. However, this process has the defects which are low productivity per hour and high cost. For that reason, tube end-forming using roll die is actively being developed, recently. The purpose of this study is to develope the tube end-forming process using roll die in order to manufacture the accumulator for the refrigeration pipe lines. First, the process design of tube end-forming was performed based on specification of product, and then was verified with FE analysis. Also, the effects of friction coefficient and revolution speed of roll die on forming load were investigated. The analytical results were applied in the final process design of tube end-forming. Finally, tube end-forming test was carried out to verify the validity of the FE analysis and the process design.