• Title/Summary/Keyword: End Diaphragm

Search Result 55, Processing Time 0.023 seconds

Dynamic Modeling and of Cylindrical Shell and Design of Active Vibration Controller equipped with MFC actuators (MFC 작동기가 부착된 실린더 쉘 구조물의 동적 모델링과 능동 진동제어기 설계)

  • Bae, Byung-Chan;Song, Myung-Ho;Jung, Moon-San;Kwak, Moon-K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.75-80
    • /
    • 2007
  • This paper is concerned with the dynamic modeling and controller design for a cylindrical shell equipped with MFC actuators. The dynamic model was derived by using Rayleigh-Ritz method based on Donnel-Mushtari shell theory. The actuator and sensors for the MFC actuator equations were derived based on pinforce model. The boundary conditions at both ends were assumed to be shear diaphragm. After calculating the natural vibration characteristics, the positive position feedback controller was designed to cope with the first two modes. To this end, the equations of motion were reduced to modal equations of motion by considering the modes of interest. The theoretical results show that vibrations can be successfully suppressed.

  • PDF

Finite Element Analysis of A Piezoelectric Actuator (압전 작동기 거동해석을 위한 유한요소 모사)

  • Lee, Heung-Shik;Cho, Chong-Du
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1401-1406
    • /
    • 2003
  • Mechanical behavior of a piezoelectric actuator is studied as a preceding research for the manufacturing of three-dimensional micro-structures. It is needed to examine the simulation of a piezoelectric actuator according to applied direction of voltage, by researching displacement characterization of piezoelectric material through piezoelectric theory. To this end, finite element modeling is employed to study the response of a piezoelectric material under the various input voltages. Where the actuator is simulated by use of ANSYS. To avoid direct contact piezoelectric material with working fluid, silicon, polymer, etc., the actuator is modeled with nickel fixed diaphragm.

  • PDF

A Study on Pylon Cable Anchor System in Cable-Stayed Railway Bridge (철도용 사장교의 주탑 케이블 정착부에 관한 연구)

  • Han, Sung-Gwan;Gong, Byung-Seung
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.565-580
    • /
    • 2006
  • Set in constant increase and period current of lively technical development of railroad use and construction of cable stayed bridge railway bridge, one of bridge form of most suitable that think side police officer and the material enemy of bridge that use long rail, is increasing laying stress on the foreign countries. Main tower fixing department of this cable stayed bridge is consisted of main tower flange that support bearing plate, bay ring plate bearing plate, support end rib and diaphragm etc, as stress transmission mechanic that tensility of cable socket into normal force of main tower, and is used this time. These structural elements is very complex the structure and direction of load delivered from socket specially calbe particularly be different, and need FEM analysis that use Thick Shell element for suitable arrangement of mutual stress flowing grasping and absence that follow hereupon because all of the each support plate angle that suport this differ.

  • PDF

Measurement of Variation in Water Equivalent Path Length by Respiratory Organ Movement

  • Minohara, Shinichi;Kanai, Tatsuaki;Endo, Masahiro;Kato, Hirotoshi;Miyamoto, Tadaaki;Tsujii, Hirohiko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.90-93
    • /
    • 2002
  • In particle radiotherapy, a shape of the beam to conform the irradiation field is statically defined by the compensator, collimator and potal devices at the outside of the patient body. However the target such as lung or liver cancer moves along with respiration. This increases the irradiated volume of normal tissue. Prior discussions about organ motions along with respiration have been mainly focused on inferior-superior movement that was usually perpendicular to beam axis. On the other hand, the change of the target depth along the beam axis is very important especially in particle radiotherapy, because the range end of beam (Bragg peak) is so sharp as to be matched to distal edge of the target. In treatment planning, the range of the particle beam inside the body is calculated using a calibration curve relating CT number and water equivalent path length (WEL) to correct the inhomogeneities of tissues. The variation in CT number along the beam path would cause the uncertainties of range calculation at treatment planning for particle radiotherapy. To estimate the uncertainties of the range calculation associated with patient breathing, we proposed the method using sequential CT images with respiration waveform, and analyzed organ motions and WELs at patients that had lung or liver cancer. The variation of the depth along the beam path was presented in WEL rather than geometrical length. In analyzed cases, WELs around the diaphragm were remarkably changed depending on the respiration, and the magnitude of these WEL variations was almost comparable to inferior-superior movement of diaphragm. The variation of WEL around the lung was influenced by heartbeat.

  • PDF

Experimental Study of the Shock Wave Dynamics in Micro Shock Tube (Micro Shock Tube에서 발생하는 충격파 실험)

  • Park, Jinouk;Kim, Gyuwan;Kim, Heuydong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.5
    • /
    • pp.54-59
    • /
    • 2013
  • Micro shock tubes are now-a-days used for a variety engineering applications such as in the field of aerospace, combustion technology and drug delivery systems. But the flow characteristics of micro shock tube will be different from that of well established conventional macro shock tube under the influence of very low Reynolds number and high Knudsen number formed due to smaller diameter. In present study, experimental studies were carried out to a closed end (downstream) Micro Shock Tube with two different diameters were investigated to understand the flow characteristics. Pressure values were measured at different locations inside the driver and driven section. The results obtained show that with the increase in diameter the shock propagation velocity increases as well as the effect of reflected shock wave will be more significant under the same diaphragm rupture pressure.

Relationship between Breathing Pattern Disorder and Pain in Patients with Chronic Low Back Pain (만성요통환자의 호흡패턴이상과 통증과의 상관관계)

  • Lim, Chae-Gil
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.4
    • /
    • pp.355-363
    • /
    • 2020
  • To investigate the relationship between breathing pattern disorder and pain in patients with chronic low back pain(CLBP). One hundred four patients were measured the End-tidal CO2(EtCO2) and respiration rate(RR) using capnography. Also, The Breathing-hold time(BHT), Nijmegen Questionnaire(NQ), and Thoracic excursion examinated. There was a significant correlation between EtCO2 and BHT, thoracic excursion(r=.302, r=.281)(p<.01), and a low negative correlation with RR, VAS(r=-.253, -200)(p<.05). There was a significant correlation between NQ and RR(r=.237)(p<.05). There was a low correlation between thoracic excursion and VAS(r=-.370)(p<.01). There was a significant difference in the EtCO2, RR, BHT, thoracic excursion, and VAS between the thoracic and diaphragm breathing pattern(p<.05). There were no significant differences in the NQ(p>.05). There was a correlation between EtCO2 and BHT, thoracic excursion, RR, VAS in patients with CLBP. In addition, There was a correlation between RR and NQ, thoracic excursion, and VAS. As a result, it was found that there is a close relationship between breathing pattern disorder and pain. There was a significant difference in the EtCO2 level, RR, BHT, thoracic excursion and VAS value in the comparison of thoracic breathing pattern and diaphragm breathing pattern. This is a meaningful result of suggesting a breathing pattern treatment approach in the rehabilitation and pain management of chronic low back pain patients in clinical practice.

Influence of stiffeners on the performance of blind-bolt end-plate connections to CFST columns

  • Ding, Fa-xing;Pan, Zhi-cheng;Liu, Peng;Huang, Shi-jian;Luo, Liang;Zhang, Tao
    • Steel and Composite Structures
    • /
    • v.36 no.4
    • /
    • pp.447-462
    • /
    • 2020
  • The paper aims to investigate the mechanical mechanism and seismic effect of stiffeners in blind bolt endplate connection to CFST column. A precise 3D finite element model with considering the cyclic properties of concrete and steel materials was established, and the efficiency was validated through monotonic and cyclic test data. The deforming pattern and the seismic performance of the unstiffened and stiffened blind bolt endplate connections were investigated. Then a parametric analysis was conducted to analyze the contribution of stiffeners and the joint working behaviors with endplate under cyclic load. The joint stiffness classifications were compared and a supplement stiffness classification method was proposed, and the energy dissipation ability of different class connections were compared and discussed. Results indicated that the main deformation pattern of unstiffened blind bolt endplate connections was the local bending of end plate. The vertical stiffeners can effectively alleviate the local bending deformation of end plate. And influence of stiffeners in thin endplate and thick endplate was different. Based on the stiffness of external diaphragm welded connection, a more detailed rigidity classification was proposed which included the pin, semi-rigid, quasi-rigid and rigid connection. Beam was the main energy dissipation source for rigid connection. For the semi-rigid and quasi-rigid connection, the extended endplate, stiffeners and steel beam would all participate in the energy dissipation.

Animal Experiment of the Pneumatic Ventrivular Assist Device (공압식 심실 보조기의 동물실험)

  • Park, Seong-Sik;Kim, Sam-hyun;Seo, Pil-won;Choi, Chang-hyu;Lee, Sang-hoon;Lee, Hyuk-soo;Hwang, Seung-ok;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.32 no.12
    • /
    • pp.1065-1077
    • /
    • 1999
  • Background : Ventricular assist devices(VADs) are being used for patients in postcvardiotomy cardiogenic shock status bridge to cardiac transplant settings and in post-myocardial infarction cardiogenic shock. The VAD which was developed at the Deparment of medical engineering in Dankook University College of Medicine was a pneumatically driven device and can maintain pulsatile flow. The goal of this study is to develop animal experimental models using the VAD and to clarify the reliability and hemodynamic property adequacy of end organ perfusion durability and severity of thrombotic-hemolytic tendency of the device. Material and Method : The pneumatic VAD was applied to 8 adult female lambs, We examined some hemodynamic parameters such as arterial blood pressure pulmonary capillary wedge pressure(pcwp) pulmonary artery pressure(PAP) left atrial pressure hour urine output cardiac index VAD flow EKG to determine the reliability of the VAD and hemodynamic compatibility of the experimental animals within 24 hours of experiment. We also observed the end organ perfusion durability of the VAD and thrombotic-hemolytic property of the VAD after 24 hours of VAD insertion. Result: We could monitor all hemodynamic parameters including pcwp PAP cardiac index EKG, adn hour urine as true clinical settings. We observed that the reliability of the VAD was excellent and the hemodynamic property of the experimental animal and end organ perfusion were adequate within 24 hours of experiment. In four lambs surviving 24 hours after insertion the reliability of the VAD and end organ perfusion were excellent and no thrombotic-hemolytic tendency was noted. However after 15 days of experiment the diaphragm of the VAD was torn and it was recommende that the durability of the VAD should be extended. Conclusion : e conclude that the pneumatic VAD developed at Dankook University Biomedical Engineering has good hemodynamic property and low thromboembolic tendency and presents adequate end organ perfusion but we noted that the durability of the device should be expanded further. It will be possible to do more reliable experiment in the future according to the animal experimental method developed in this study especially with the heart failure models.

  • PDF

Lamellar Body Counts in Fetal Rabbits' Experimental Diaphragmatic Hernia and Tracheal Ligation (기도결찰을 시행한 토끼 태자의 실험적 횡격막탈장에서 Lamellar body counts)

  • Chun, Yong-Soon;Jung, Soo-Jin;Lee, Jeong-Nyeo
    • Advances in pediatric surgery
    • /
    • v.17 no.2
    • /
    • pp.179-187
    • /
    • 2011
  • Experimental tracheal ligation (TL) has been shown to reverse the pulmonary hypoplasia associated with congenital diaphragmatic hernia (CDH) and to normalize gas exchange. The purpose of this study was to determine whether the TL would correct the surfactant deficiency present in the fetal rabbit model of CDH by using lamellar body count. Lamellar bodies are synthesized and secreted by the type II pneumocytes of fetal lung. The phospholipids present in these bodies constitute the major component of pulmonary surfactant. Twenty-one pregnant New Zealand rabbits underwent hysterotomy and fetal surgery on gestational day 24. Two fetuses of each pregnant rabbit were operated. In the fetus of one end of bicornuate uterus, left DH was created by excision of fetal diaphragm through open thoracotomy (DH Group). In the fetus of the other end of bicornuate uterus, left DH and TL were created (TL Group). The fetuses were delivered by Cesarean section on gestational day 31. Fourteen in control group, 12 in the DH group and 13 in TL group were born alive. En bloc excision of lungs, bronchi and trachea was done in all newborn rabbits. A five Fr catheter was inserted through trachea and repeated irrigations with 10 cc normal saline were done. The irrigated fluid was centrifuged at $280{\times}g$ for 5 minutes and the lamellar bodies were counted with the upper level fluid in platelet channel of electronic cell counter. The average lamellar body counts were $37.1{\pm}14.2{\times}10^3/{\mu}L$ in control group, $11.5{\pm}4.4 {\times}10^3/{\mu}L$ in DH group, and $6.5{\pm}0.9{\times}10^3/{\mu}L$ in TL group. Lamellar body count in DH group was lower than in control group and did not increase after TL. This study shows TL has no therapeutic effect on decreased surfactant level of CDH and the pregnant rabbit is appropriate for the animal model of CDH.

  • PDF

An Extended Data Model based on the IFC for Representing Detailed Design Information of Steel Bridge Members (강교 부재의 상세 설계정보 표현을 위한 IFC기반의 데이터 모델 확장)

  • Lee, Jin-Hoon;Lee, Ji-Hoon;Kim, Hyo-Jin;Lee, Sang-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.3
    • /
    • pp.253-263
    • /
    • 2008
  • Extension of IFC data model for steel bridge members is proposed to represent detailed design information. First of all, the design data items and their representation method are classified by analyzing primary references such as design specification, structural calculation documents and shop drawings. Some of the classified items are enough to be represented by the existing IFC model. However, the need of additional model is noted to systematically represent the design information for other items such as stiffener, diaphragm, joint system, and shear connector. An inheritance relations and properties for added model are also defined. The application program based on the proposed data model is developed. In the end, by loading the application program on the AutoCAD 2002 program, end-users can input the design information of steel bridge members. The applicability and efficiency of the proposed data model and the program are verified by checking the section area, intervals, and interferences.