• 제목/요약/키워드: Emission Control

검색결과 1,564건 처리시간 0.024초

대구시 서구 산업단지 주변 지역의 악취오염도와 악취감시시스템 운영 평가 (Evaluation of the Odor around an Industrial Complex Area and the Operational Effects of the Odor Monitoring System in Seo-gu, Daegu City)

  • 이명숙;금종록;강동훈;조항욱;권병윤;김은덕;이찬형;송희봉;신상희
    • 한국환경보건학회지
    • /
    • 제47권1호
    • /
    • pp.45-54
    • /
    • 2021
  • Objectives: This study evaluated the odor around an industrial complex area (#1-#5) and the operational effects of the Odor Monitoring System in Seo-gu in Daegu City. Methods: Samples were collected from November 2012 to December 2018 and were analyzed for complex odor. The odor occurrence rate and the odor reduction rate were calculated. Results: In 2018, the mean concentration of complex odor decreased 20.9% and the odor occurrence rate decreased from 65.0 to 27.5% around the industrial complex area (#1-#5) in Seo-gu compared to 2013. After the operation of the Odor Monitoring System, the standard excess rate (3.0%→40.8%) and the excess concentration of complex odor (1,442→4,304) increased at odor-emitting workplaces. In addition, the mean concentration of complex odor (15.9%) and the odor occurrence rate (60.6%→32.9%) around the industrial complex area (#1-#5) and the number of odor complaints (23.4%) in Seo-gu decreased. Conclusion: In order to reduce the odor around the industrial complex area, it is important to improve the odor emitting facilities. The Odor Monitoring System uses scientific and systematic monitoring methods that can help control and manage the odor emission facilities.

실험 및 수치해석을 통한 LNG 벙커링 선박들의 이접안 안정성 평가 연구 (Experimental and Numerical Study of Berthing and Unberthing of LNG-Bunkering Vessels)

  • 정성준;오승훈;정동우;김윤호;정동호
    • 한국항해항만학회지
    • /
    • 제44권6호
    • /
    • pp.439-446
    • /
    • 2020
  • 세계적인 환경오염 규제 및 IMO(국제해사기구)의 선박 연료 황 함유량 제한으로 LNG를 선박의 연료로 사용하는 연구 및 사업이 활발히 진행되고 있다. 본 연구에서는 기존 연구를 통해 개발된 부유식 LNG 벙커링 터미널(FLBT, Floating LNG bunkering terminal)을 대상으로, STS LNG 벙커링 작업을 위해 이접안 하는 과정을 벙커링 셔틀선의 환경하중을 모형시험과 수치해석으로 평가하였다. 고차경계요소법을 이용한 수치해석으로 가까운 위치에서 상호작용 하는 4척 선박들의 파랑표류력 변화를 검토하였다. 다양한 이접안 거리에 따라 파랑표류력이 크게 변함을 확인 했다. 모형시험은 선박해양플랜트연구소의 해양공학수조에서 이루어졌다. 모형시험에서는 예인선을 모사하여 대상선박을 밀고 당길 수 있는 치구를 고안하였으며 접안시 마찰력 등의 영향 없이 선박을 밀 수 있도록 하였다. 모형시험 결과 LNG벙커링 선박은 대부분의 1년 환경조건에서 안전한 이접안이 가능하였다. 파랑 방향에 따라 안정성의 차이가 존재함으로, FLBT의 Heading conrol 기능을 적용하여 횡파를 피한다면 더욱 안정적인 운용이 가능할 것이다.

안산·시흥 산업단지 지역 PM2.5 중 이온, 탄소, 원소성분의 특성 연구 (A Study on the Characteristics of Ion, Carbon, and Elemental Components in PM2.5 at Industrial Complexes in Ansan and Siheung)

  • 이혜원;이승현;전정인;이정일;이철민
    • 한국환경보건학회지
    • /
    • 제48권2호
    • /
    • pp.66-74
    • /
    • 2022
  • Background: The health effects of particulate matter (PM2.5) bonded with various harmful chemicals differ based on their composition, so investigating and managing their concentrations and composition is vital for long-term management. As industrial complexes emit considerable quantities of pollutants, higher PM2.5 concentrations and chemical component effects are expected than in other places. Objectives: We investigated the concentration distribution ratios of PM2.5 chemical components to provide basic data to inform future major emissions control and PM2.5 reduction measures in industrial complexes. Methods: We monitored five sites near the Ansan and Siheung industrial complexes from August 2020 to July 2021. Samples were collected and analyzed twice per week in spring/winter and once per week in summer/autumn according to the National Institute of Environmental Research in the Ministry of Environments' Air Pollution Monitoring Network Installation and Operation Guidelines. We investigated and compared composition ratios of 29 ions, carbon, and elemental components in PM2.5. Results: The analysis of PM2.5 components at the five sites revealed that ion components accounted for the greatest total mass at approximately 50% while carbon components and elemental components contributed 23~28% and 8~10%, respectively. Among the ionic components, NO3- occupies the greatest proportion. OC occupies the greatest proportion of the carbon components and sulphur occupies the greatest proportion of elemental components. Conclusions: This study investigated the concentration distribution ratios of PM2.5 chemical components in industrial complexes. We believe these results provide basic chemical component concentration ratio data for establishing future air management policies and plans for the Ansan and Siheung industrial complexes.

피지국에서의 의료폐기물 처리현황과 문제점 (Challenges of Medical Waste Treatment in Fiji)

  • 김대선;;;이철우
    • 적정기술학회지
    • /
    • 제6권1호
    • /
    • pp.37-44
    • /
    • 2020
  • 의료폐기물은 감염성물질을 함유하고 있는 모든 종류의 폐기물을 가리키며 전염을 예방하기 위해 운송에 신중을 기해야 한다. 처리 수단으로의 소각은 부피 감소, 악취 제거, 위해성 측면에서 매립이나 투기보다 장점을 갖고 있다. 야외 소각이나 바람직하지 않은 환경에서의 소각은 환경오염 물질의 대기 중 배출을, 생물학적 폐기물의 매립은 토양과 수질오염을 야기시킨다. 피지의 대부분의 2차 병원은 의료 폐기물을 세 군데에 있는 3차 병원으로 차량 또는 배로 이송하여 소각 처리한다. 어떤 의료폐기물은 일반폐기물로 간주되어 현장에서 야외 소각되거나 출산 시 발생한 생물학적 의료폐기물은 매립되기도 하였다. 이런 측면에서 의료폐기물 처리 관련 인력들에 대한 인식 증진을 위한 교육이 시급하다. 피지에서의 의료폐기물 처리는 단일 도로를 따르는 차량운송, 배를 이용한 도서간 운송보다 소형 소각로를 이용한 현장소각이 권장되며, 가이드라인 제정, 관련 인력 훈련, 정부의 법률적 제정 등 의료 폐기물 처리를 위한 기반 조성이 필요하다.

화력발전소 배출량 제거에 따른 여름철 O3 농도의 변화 특성 (Effect of Removal of Power Plant Emissions on the characteristics of Ozone Concentration Changes in Summer)

  • 김동진;전원배;박재형;문정혁
    • 한국지구과학회지
    • /
    • 제42권2호
    • /
    • pp.149-163
    • /
    • 2021
  • 본 연구에서는 광화학 대기질 모델인 CMAQ을 활용해 화력발전소 배출량 제거에 따른 O3 농도의 변화 특성을 분석하였다. 하동 화력발전소를 대상으로 주변 지역의 O3 농도 변화에 대한 발전소 배출량의 영향을 조사하기 위해 하동 화력발전소의 배출량 제거 전과 후의 CMAQ 수치 모의를 수행하였다. 수치 모의 결과 O3의 주요 전구 물질인 NOx (-18.87%)와 VOCs (-11.27%)의 농도가 감소한 반면에 O3 (25.24%)의 농도는 증가한 것으로 나타났다. 화력발전소 배출량 제거로 인한 NO와 O3 농도의 상대적인 변화를 비교해 본 결과 높은 음의 상관관계(R= -0.72)를 나타내는 것이 확인되었다. 이러한 결과는 O3의 농도 증가가 NO 농도 감소로 인한 O3의 적정 효과 완화로 설명 될 수 있음을 의미한다. 해당 지역의 O3의 농도 증가가 NO의 농도 감소에 주로 영향을 받은 이유는 해당 지역이 VOC-limited (i.e., NOx-saturated) 지역이기 때문으로 분석되었다. 이러한 결과는 특정 지역의 O3의 농도가 단순히 배출량의 증감에 따라 비례하게 나타나지 않을 수 있다는 것을 암시한다. 따라서 화력발전소 배출량 저감 조치로 인한 대기 중 O3 농도 개선 효과를 정확히 예측 및 평가하기 위해서는 지역 별 O3의 생성 및 소멸 기작에 대한 심도 있는 이해가 필요하다.

Acetohydroxamic acid 이용한 Urea로부터 암모니아 발생 저감 연구 (Reduction of ammonia conversion from urea by adding acetohydroxamic acid)

  • 윤광수;오하은;정민웅;황옥화;윤여명
    • 유기물자원화
    • /
    • 제29권4호
    • /
    • pp.5-13
    • /
    • 2021
  • 가축분뇨의 요소에서 유래하는 암모니아는 미세먼지(PM2.5) 생성의 주요 전구체로 작용하여 대기질을 저하시키고 공중 보건에 유해한 영향을 미치는 것으로 알려져 있다. 본 연구의 목적은 Acetohydroxamic acid(AHA)의 주입에 따른 요소로부터 암모니아 전환의 억제에 대한 효과를 평가하는 것이었다. 실험은 다양한 요소 농도(500-4,000 mg Urea-N/L), AHA 농도(0-4,000 mg AHA/L), pH(pH 6-10) 및 온도(10-35℃)범위에서 수행되었다. 그 결과 AHA 농도가 높을수록 Urease 억제 효율이 증가함을 보여주었다. 그러나 특정 Urease 억제 활성은 pH가 높을수록 감소하여 pH 6에서 867.1±6.7 Unit/g AHA, pH 10에서 1,167.9±17.4 Unit/g AHA를 나타냈다. AHA와 대조군 모두에서 높은 온도에서 요소분해효소 억제 효율이 감소됨을 확인하였다. 본 연구결과를 통해 AHA가 가축분뇨 관리에서 암모니아 배출을 줄이기 위한 요소분해효소 억제제로 사용될 수 있음을 확인하였다.

Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar

  • Chae, Sung-Ki;Cho, Won-Tak;Choi, Jae-Won;Bae, Eun-Bin;Bae, Ji-Hyeon;Bae, Gang-Ho;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.12-21
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models. MATERIALS AND METHODS. Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADD-TOC; PNUAdd Co., Ltd., Busan, Republic of Korea) as the experimental group. A CAD-CAM milled bar was mounted on a master model and 3 threaded holes for connecting a bar attachment was formed using a tap. Locator and ADD-TOC attachments were then attached to the milled bar. Simulated mastication and repeated insertion/removal were performed over 400,000 cyclic loadings and 1,080 insertions/removals, respectively. Wear patterns on deformed attachment were investigated by field emission scanning electron microscopy. RESULTS. For the ADD-TOC attachments, chewing simulation and repeated insertion/removal resulted in a mean initial retentive force of 24.43 ± 4.89 N, which were significantly lower than that of the Locator attachment, 34.33 ± 8.25 N (P < .05). Amounts of retention loss relative to baseline for the Locator and ADD-TOC attachments were 21.74 ± 7.07 and 8.98 ± 5.76 N (P < .05). CONCLUSION. CAD-CAM milled bar with the ADD-TOC attachment had a lower initial retentive force than the Locator attachment. However, the ADD-TOC attachment might be suitable for long-term use as it showed less deformation and had a higher retentive force after simulated mastication and insertion/removal repetitions.

울산 산단지역 PM2.5 중 중금속 노출에 의한 건강위해성평가 (Health Risk Assessment by Exposure to Heavy Metals in PM2.5 in Ulsan Industrial Complex Area)

  • 정지윤;이혜원;박시현;이정일;윤단기;이철민
    • 한국환경보건학회지
    • /
    • 제49권2호
    • /
    • pp.108-117
    • /
    • 2023
  • Background: When particles are absorbed into the human body, they penetrate deep into the lungs and interact with the tissues of the body. Heavy metals in PM2.5 can cause various diseases. The main source of PM2.5 emissions in South Korea's atmosphere has been surveyed to be places of business. Objectives: The concentration of heavy metals in PM2.5 near the Ulsan Industrial Complex was measured and a health risk assessment was performed for residents near the industrial complex for exposure to heavy metals in PM2.5. Methods: Concentrations of heavy metals in PM2.5 were measured at four measurement sites (Ulsan, Mipo, Onsan, Maegok) near the industrial complexes. Heavy metals were analyzed according to the Air Pollution Monitoring Network Installation and Operation Guidelines presented by the National Institute of Environmental Research. Among them, only five substances (Mn, Ni, As, Cd, Cr6+) were targeted. The risk assessment was conducted on inhalation exposure for five age groups, and the excess cancer risk and hazard quotient were calculated. Results: In the risk assessment of exposure to heavy metals in PM2.5, As, Cd, and Cr6+ exceeded the risk tolerance standard of 10-6 for carcinogenic hazards. The highest hazard levels were observed in Onsan and Mipo industrial complexes. In the case of non-carcinogenic hazards, Mn was identified as exceeding the hazard tolerance of 1, and it showed the highest hazard in the Ulsan Industrial Complex. Conclusions: This study presented a detailed health risk from exposure to heavy metals in PM2.5 by industrial complexes located in Ulsan among five age groups. It is expected to be utilized as the basis for preparing damage control and industrial emission reduction measures against PM2.5 exposure at the Ulsan Industrial Complex.

전탕 전과 후의 한약재 및 처방에 포함된 위해물질의 농도변화 -다빈도 한약 처방을 중심으로- (Concentration of Hazardous Substances of Before/after a Decoction- In Prescription of High Frequency -)

  • 서창섭;황대선;이준경;하혜경;천진미;엄영란;장설;신현규
    • 대한본초학회지
    • /
    • 제24권2호
    • /
    • pp.13-20
    • /
    • 2009
  • Objectives: To compare the contents of hazardous substances before/after a decoction. Methods : The heavy metal contents before/after a decoction were measured by Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES) and mercury analyzer. In order to analyze pesticides in 6 samples we used simultaneous multi-residue analysis of pesticides by GC/ECD, which was followed by GC/MSD analysis to confirm the identity of the detected pesticide in each sample. In addition, the contents of sulfur dioxide (S02) were performed by Monier-Williams distillation method. Results : 1. The mean values of heavy metal contents (mg/kg) for the samples were as follows: Socheongryong-tang (before decoction - Pb; 1.115, Cd; 0.179, As; 0.069 and Hg; 0.028, after decoction - Pb; 0.110, Cd; 0.011, As; 0.005 and Hg; 0.002), Insampaedok-san (before decoction - Pb; 1.207, Cd; 0.148, As; 0.171 and Hg; 0.026, after decoction - Pb; 0.075, Cd; 0.006, As; not detected and Hg; O.OOD, Oryung-san (before decoction - Pb; 1.955, Cd; 0.430, As; 0.063 and Hg; 0.027, after decoction - Pb; 0.083, Cd; 0.013, As; 0.006 and Hg; 0.002), Hwangryunhaedok-tang (before decoction - Pb; 1.825, Cd; 0.210, As; 0.050 and Hg; 0.009, after decoction - Pb; 0.107, Cd; 0.010, As; 0.005 and Hg; O.OOD, Bangpungtongseong-san (before decoction - Pb; 1.740, Cd; 0.162, As; 0.585 and Hg; 0.018, after decoction - Pb; 0.041, Cd; 0.006, As; 0.022 and Hg; not detected) and Oyaksungi-san (before decoction - Pb; 1.199, Cd; 0.183, As; 0.321 and Hg; 0.031, after decoction - Pb; 0.096, Cd; 0.008, As; 0.021 and Hg; 0.0004). 2. Contents (mg/kg) of sulfur dioxide (S0$_2$) before a decoction in Socheongryong-tang, Insampaedok-san, Oryung-san, Hwangryunhaedok-tang, Bangpungtongseong-san and Oyaksungi-san exhibited 3.2, 5.7, 4.5, 49.8, 7.8 and 22.4, respectively. However, contents of sulfur dioxide after a decoction in all samples were not detected. 3. Contents (mg/kg) of residual pesticides before/after a decoction in all samples were not detected. Conclusions : These results will be used to establish a criterion of heavy metals, residual pesticides and sulfur dioxide.

항공기 기내 청소노동자의 분진, 초미세먼지(PM2.5) 및 블랙카본 노출수준 평가 (Exposure Assessment of Dust, Ultra Fine Dust(Particulate Matter 2.5, PM2.5) and Black Carbon among Aircraft Cabin Cleaners)

  • 박현희;김세동;김성호;박승현
    • 한국산업보건학회지
    • /
    • 제33권2호
    • /
    • pp.171-187
    • /
    • 2023
  • Objectives: Aircraft cabin cleaning work is characterized by being performed within a limited time in a narrow and enclosed space. The objective of this study was to evaluate the exposure levels to dust, ultra fine dust(PM2.5) and black carbon(BC) among aircraft cabin cleaners. Methods: Active personal air sampling for respirable dust(n=73) and BC(n=47) was conducted during quick transit cleaning(cabin general and vacuum-specific) and seat cover replacement and total dust and PM2.5 were area-air-sampled as well. Also, size distribution of particle was identified with the cleaning workers targeted. Dusts were collected with PVC filters using gravimetric analysis. The concentration of PM2.5 and the particle size distribution were measured with real-time direct reading portable equipment using light scattering analysis. The concentration of BC was measured by aethalometer(filter-based real-time light absorption analysis instrument). Results: The geometric mean of respirable dust was the highest at vacuum cleaning as 74.4 ㎍/m3, following by replacing seat covers as 49.3 ㎍/m3 and cabin general cleaning as 47.8 ㎍/m3 . The arithmetic mean of PM2.5 was 4.83 ~ 9.89 ㎍/m3 inside the cabin, and 28.5~44.5 ㎍/m3 outside the cabin(from bus and outdoor waiting space). From size distribution, PM2.5/PM10 ratio was 0.54 at quick transit cleaning and 0.41 at replacing seat covers. The average concentration of BC was 2~7 ㎍/m3, showing a high correlation with the PM2.5 concentration. Conclusions: The hazards concentration levels of aircraft cabin cleaners were very similar to those of roadside outdoor workers. As the main source of pollution is estimated to be diesel vehicles operating at airports, and it is necessary to replace older vehicles, strengthen pollutant emission control regulations, and introduce electric vehicles. In addition, it is necessary to provide as part of airport-inftastructure a stable standby waiting space for aircraft cabin cleaners and introduce a systematic safety and health management system for all workers in the aviation industry.