• 제목/요약/키워드: Emergency lantern

검색결과 4건 처리시간 0.017초

자동화재탐지설비와 휴대용비상조명등의 연동에 대한 연구 (The study of Connection Emergency lantern with Fire Alarm System)

  • 전중함;이상화;권오수
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.108-111
    • /
    • 2008
  • Emergency lantern is an escape equipment of fire fighting. This equipment of obligation installation in buildings. But, We cast doubt on this equipment's reliability. Therefor we have need to study of this equipment's reliability. This paper research general emergency lantern for up grade reliability. For connection to fire alarm system, alarm for get lost general emergency lantern, and pilot lamp for interruption of electric power, and charge to rechargeable battery in general emergency lantern from fire alarm system. Then view very good result in reliability.

  • PDF

자동이탈식 비상침선표지 개발을 위한 개념설계 연구 (The Conceptual Design of Auto Releasing Emergency Wreck Marking Buoys)

  • 국승기;박혜리
    • 해양환경안전학회지
    • /
    • 제22권5호
    • /
    • pp.417-422
    • /
    • 2016
  • 항로표지란 해상교통의 안전을 도모하고 선박운항 능률을 향상시키기 위한 해양교통안전시설로 새로운 위험물(New Danger)은 측방표지, 방위표지, 고립장해표지 등을 이용하거나 비상침선표지(Emergency Wreck Marking Buoy)를 사용하여 적절하게 표시하여야 한다. 그러나, 침선표지의 경우 설치의 신속성, 정확성, 부표의 특성 등의 문제로 인해 실질적인 설치 운영상의 문제가 제기 되고 있으며, 선박침몰 사고의 경우 기상악화, 해역의 특성, 사고 위치의 확인이 어려워 신속한 신위험물표지(New Danger Mark) 설치가 어려운 실정이다. 이 연구는 항상 선박 상갑판에 부착된 해양안전설비 중 하나로 Maritime Buoyage System(MBS)에 근거한 자동이탈식 비상침선표지를 개발하였다. 자동이탈식 비상침선표지Auto Releasing Emergency Wreck Marking Buoy)는 총 3개의 세부기술(자동이탈, 자동릴체인, 자동구동등명기)로 구성되며, 선박 상갑판에 부착된 자동이탈식 비상침선표지가 선박의 좌초 전복 침몰 등 해양사고 발생 시 일정수압에 의해 자동으로 이탈(Auto Release) 후 자기 부상(Auto Buoyance)하여 사고 발생 지점에 신속하고 정확하게 설치된다. 이러한 자동이탈식 비상침선표지는 선박의 항해안전을 위협하는 장해물로부터 해당 해역에서의 2차 사고를 방지하고, 신속한 수색 및 구조가 이루어질 수 있도록 한다.

사고사례 정밀분석을 통한 상압저장탱크의 안전에 관한 연구 (A Study on Safety of Atmospheric Storage Tank through Detailed Analysis of Accident Case)

  • 임지표;박수율
    • 한국안전학회지
    • /
    • 제34권4호
    • /
    • pp.41-48
    • /
    • 2019
  • In October 2018, a large fire occurred after an explosion in an internal floating roof tank (IFRT) that stores gasoline by wind lantern in Goyang city, Gyeonggi-do. Although there was no casualty damage, the fire inside the tank lasted for 17 hours, and caused a great wave socially, and it was a chance to review the safety of the atmospheric storage tank. In this study, the necessity of installing a flame arrester at peripheral vents was examined through the calculation of the size of ventilation pipe and ventilation rate of internal floating roof tanks in terms of the function of the peripheral vent. Next, the necessity of the emergency shut-off valve linked with the high-level alarm to prevent the overflow of the atmospheric storage tank was confirmed by LOPA. Finally, safety measures to prevent overpressure, flame propagation and overflow which cause major accidents in atmospheric storage tank are suggested.

자동이탈식 위험표시부표 개발에 관한 연구 (Study on the Development of Auto Releasing New Danger Mark Buoy)

  • 국승기;박혜리
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2016년도 춘계학술대회
    • /
    • pp.20-21
    • /
    • 2016
  • 항로표지란 해상교통의 안전을 도모하고 선박운항의 능률성을 향상시키기 위한 해양교통안전시설로서 국제적으로 IALA 규정 및 권고사항에 따라 적용하고 있다. 그 중 "새로운 위험물(New Danger)"는 항해용 해도 등의 수로서지에 미기재된 것으로 새로이 발견된 위험장해물을 라고 정의하고 있으며, 사주나 암초 등의 자연적 장해물 또는 침선과 같은 인위적 장해물을 포함한다. 이러한 새로운 위험물은 측방표지, 방위표지, 고립장해표지 등을 이용하거나 비상침선표지(Emergency Wreck Marking Buoy)를 사용하여 적절하게 표시하여야 한다. 그러나, 침선표지의 경우 설치의 신속성, 정확성, 부표의 특성 등의 문제로 인해 실질적인 설치 운영상의 문제가 제기 되고 있으며, 선박 침몰 사고의 경우 기상악화, 해역의 특성, 사고 위치의 확인이 어려워 신속한 신위험물표지(New Danger Mark) 설치가 어려운 실정이다. 이 연구는 선박 상갑판에 부착된 소형 침선표지가 선박의 실종 전복 침몰 등 해양사고 발생 시 일정수압에 의해 자동으로 이탈(Auto Release) 후 자기 부상(Auto Buoyance)하여 사고 발생 지점에 신속하고 정확하게 설치되도록 하는 시스템을 개발하고자 한다.

  • PDF