• Title/Summary/Keyword: Emergency Power Generator

Search Result 124, Processing Time 0.037 seconds

A Study on Operation Scheme of STS with Emergency Generator for Peak Shedding (첨두부하 저감을 위한 비상발전기 연계형 STS 운영 방안에 관한 연구)

  • Kim, Chang-Hwan;Rhee, Sang-Bong;Kim, Kyu-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.155-156
    • /
    • 2015
  • Recently, electricity consumption has rapidly increased along with economic growth. The operating strategy using emergency generator is aimed, to resolve a demand response management. For strategy of peak shedding using emergency generator, it is essential to introduce the fast transfer switching device. One of the most effective solutions is to use a static transfer switch (STS) based on thyristor. However, the characteristic of natural commutated SCR thyristor should anticipate short duration voltage sag. STS system thus requires more than a quarter cycle to successfully complete transfer process. This paper proposes the operation scheme of the STS system using the forced-commutation technique to mitigate instantaneous voltage sag during peak transfer process. Proposed STS system improved turn-off characteristic thus accomplishes the peak load shedding satisfied power quality. Performance of the proposed STS system is evaluated using electromagnetic transient program (EMTP) to confirm the effectiveness.

  • PDF

Development of Supply Capability Calculation and Prediction Technology for Generator (발전기 공급능력 산정 및 예측 기술개발)

  • Kim, Euihwan;An, Youngmo;Hong, Eunkee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.425-431
    • /
    • 2016
  • Supply Capability of the generator, if the maximum demand occurs, refers to the maximum power that can be stably supplied and it is possible to maintain stable power supply to be greater than actual load. However, unexpected power demand and reduction in supply Capability due to stop of unexpected generator in operation can temporarily make a big chaos in power system. In fact, due to a lack of power supply Capability in the country, enforced emergency load adjustment to the September 15, 2011, the circulation power outage has occurred in several cities. As the result, interrupted operation of the elevator and stopped hospital medical equipment led to a great deal of trouble to people's lives, causing a social problem. At that time, it was found that a failed frequency control because of smaller actual supply Capability than that of predicted. The difference was about 1,170 MW with Gas turbine power plant. By accurately calculating the generator supply capability, we can not only grasp the power reserve rate, but also correspond to the time of power supply instability.

On Hunting Protected Circuit at the Inflow about Load direction Harmonics of a Small Size the Generator (소형 발전기의 부하측 고조파 유입시 HUNTING 방지회로)

  • Bae, Jong-Il;Park, Byeong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2668-2670
    • /
    • 2002
  • The generators of a small size below 100Kw are often used as power suppliers for emergency only in most domestic telecommunication companies. Serious twisted waves occur due to the inflow of harmonies from the generator into a S-type rectifier. And the increasing by stages of load upon the rectifier end up a stoppage of power supply during the serious hunting, which makes it difficult to supply power securely on the other part as well as that of communications. In case of long time of power failure the generators of a small size will be essential because the battery for emergency has a limit in capacity. Therefore it is necessary to solve the problems concerning the generators. This study is focused on the identifying and solving the problem including use of SCR elements connected to the generators.

  • PDF

Investigation of Excitation System for Nuclear Emergency Diesel Generator (원전 비상디젤발전기 여자시스템 고찰)

  • Shin, Man-Su;Lee, Joo-Hyun;Lim, Ick-Hun;Jeong, Tae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1894-1895
    • /
    • 2007
  • It is excitation system for nuclear emergency generator that is to startup automatically and sequentially supply essential loads with power. There are static type and alternating exciter, etc in its excitation system. An object of study is static excitation system which power is taken from power potential transformer and power current transformer. It is to complement curtailment of excitation system ability at happening short accidents. And Startup mode are quick startup and slow startup, etc. Its characteristic is looked into in this paper.

  • PDF

The Proposal for Reliability Improvement of Emergency Diesel Engines through the Evaluation of the Maintenance Program and Overseas Cases for their Applications (정비프로그램 평가 및 해외사례 분석을 통한 비상디젤엔진의 신뢰성 향상방안)

  • Cho, K.H.;Jeong, H.J.;Ahn, S.K.
    • Journal of Power System Engineering
    • /
    • v.8 no.2
    • /
    • pp.5-11
    • /
    • 2004
  • The failure frequency of the Emergency Diesel Generator(EDG) at Nuclear Power Plants(NPPs) is not so much lower than that of the Marine engines, whereas the running hours of the diesel engine at NPPs is much less than those of the engines for commercial service. The primary factor results from the severe surveillance test requirements such as fast start, large number of starting test, fast load-run, high load running, etc. The other factor comes from the excessive maintenance based on the engine maker's instruction manual that did not incorporate the peculiar characteristics of the diesel engines at NPPs. In this paper, the present preventive maintenance program on the basis of the Pielstick diesel engines was reviewed for the purpose of securing the reliability of the emergency diesel generator at NPPs and the ways for its improvement were presented by referring to the overseas cases for their applications.

  • PDF

A Field Test of Diesel Generator Excitation Control System Using Real Time Simulator (실시간 시뮬레이터를 이용한 디젤발전기 여자시스템 현장시험)

  • Lee, Joo-Hyun;Rhew, Ho-Sun;Jeong, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1314-1319
    • /
    • 2010
  • The excitation control system of an emergency diesel generator is classified as a kind of safety-related system. Compared with other control systems in a power plant, this system is required to be more reliable and have better performance. KEPCO Research Institute successfully developed the excitation control system for a diesel generator. This paper presents its field test results by using a real time simulator on a nuclear power plant.

Operating Vibration Reduction Effect Evaluation of EDG at the NPP Site (원자력발전소 비상디젤발전기의 가동중 진동저감 효과)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.111-118
    • /
    • 2006
  • The Emergency Diesel Generator(EDG) is a very important piece of equipment for the safety of a Nuclear Power Plant(NPP). In this study, the operating vibration or three kinds or EDG system was measured. The target EDG systems art Yonggwang 5 unit, Ulchin 2 unit and Ulchin 3 unit. The Yonggwang 5 and Ulchin 3 unit EDG system is the same type but the foundation systems are different. One is an anchor bolt type and the other is a spring and viscous-damper type. The purpose of this measurement is for a verification of the vibration isolation effect according to the foundation system. As a result. it can he said that the spring and viscous damper system of the EDG performed well for the vibration isolation.

  • PDF