• 제목/요약/키워드: Emergency Power Generator

검색결과 124건 처리시간 0.022초

건축물 내외부에 설치된 비상용 발전기 소음영향 평가 및 대책방안 사례연구 (A Case Study on Noise Impact Assessments and Countermeasures for Emergency Generators of the Data Center Building)

  • 윤대진;최재성;김창열;김한준
    • 한국소음진동공학회논문집
    • /
    • 제22권10호
    • /
    • pp.932-939
    • /
    • 2012
  • Recently, data centers are being established because IT and telecommunication industries are growing. The data centers have to install emergency generators to prevent unexpected shutdown of the electrical power supply. When the data centers are located in the densely populated urban area, the operating noise of the emergency generators can be a cause of people's complaints. In this case, it is necessary to establish effective countermeasure by noise & vibration specialists. To achieve this, noise reduction measure using noise measurement data and 3D noise analysis method have been employed in this study.

분산발전자원을 활용한 가상발전소 기반 기술의 전력시장 참여 방안에 대한 연구 (A Study on the Participation of Virtual Power Plant Based Technology Utilizing Distributed Generation Resources in Electricity Market)

  • 이윤환
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.94-100
    • /
    • 2016
  • A virtual power plant (VPP) technology is a cluster of distributed generation installations. VPP system is that integrates several types of distributed generation sources, so as to give a reliable overall power supply. Virtual power plant systems play a key role in the smart grids concept and the move towards alternative sources of energy. They ensure improved integration of the renewable energy generation into the grids and the electricity market. VPPs not only deal with the supply side, but also help manage demand and ensure reliability of grid functions through demand response (DR) and other load shifting approaches in real time. In this paper, utilizing a variety of distributed generation resources(such as emergency generator, commercial generator, energy storage device), activation scheme of the virtual power plant technology. In addition, through the analysis of the domestic electricity market, it describes a scheme that can be a virtual power plant to participate in electricity market. It attempts to derive the policy support recommendation in order to obtain the basics to the prepared in position of power generation companies for the commercialization of virtual power plant.

비상디젤발전기 신뢰도에 대한 베이즈추정 (Bayes Estimate for the Reliability of Nuclear-Power Plant Emergency Diesel Generator)

  • 심규박;류부형
    • 품질경영학회지
    • /
    • 제25권3호
    • /
    • pp.108-118
    • /
    • 1997
  • A commercial nuclear power station contains at least two emergency diesel generates(EDG) to control the risk of severe core demage during the station blackout accidents. Therefore the reliability of the EDG's to start and load-run on demend must be maintained at a sufficiently high level. Until now, a simple assessment of start and load-run success rates was used to calculate the EDG's reliability. However, this method has been found to contain many defects. Recently, the work of Martz et al.(1996) proposed the use of the Bayes estimator to find the EDG's reliability. In this paper, we will propose confidence interval for the Bayes estimator, compare the above two methods and, using practical examples, illustrate why the Bayes estimator method is more reasonable in our situation.

  • PDF

Coil Spring & Viscose Damper System의 동적거동특성분석 (Mechanical Characteristics Analysis of Coil Spring & Viscous Damper System)

  • 김민규;전영선
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.471-478
    • /
    • 2006
  • This paper presents the results of experimental studies of the mechanical characteristics of the Coil Spring and Viscous Damper system. The Coil Spring and Viscous Damper systems were selected for the isolation of Emergency Diesel Generator (EDG) which is located in Nuclear Power Plant (NPP). The Coil Spring and Viscous Damper systems were developed for, the operating vibration isolation and seismic isolation for scaled Model EDG System. The damping properties of the viscous damper changes as the variation of velocity. As a results, nonlinear damping characteristics of viscous damper system were evaluated.

  • PDF

최소 컷셋법에 의한 화력발전소 기동전원의 신뢰도 예측에 관한 연구 (A Study on the Reliability Evaluation of Start-up Power Supply in Fossil Power Plant by Minimal Cut-Set Method)

  • 최규식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권4호
    • /
    • pp.358-364
    • /
    • 1999
  • The auxiliary transformers or start-up/stand-by transformer(s) are installed against the start-up and shut-down of generator and emergency status in fossil power plant. The on-site power supply configuration using these transformers must be determined, considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and ecfonomy of plant. The auxiliary or start-up/stand-by power supply configuration has been determined considering only safety requirements and construction cost until now in Korea. This paper presents general theorems for the reliability estimation and proposes 2-unit based 4 alternatives for the start-up power supply stystem of 500㎿ standardized fossil power plant. The reliability and unavailability of equipment, system and configuration are determined using minimal cut-set methodology. The optimized plan of 4 alternatives is determined based on this ultimate reliability and unavailability.

  • PDF

공동주택의 비상발전기 용량산정방식에 관한 고찰 (Some Considerations on the Capacity Estimation of Emergency Electric Generator in Apartment Complex)

  • 김정태;이욱
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제10권4호
    • /
    • pp.68-77
    • /
    • 1996
  • 본 연구에서는 공동주택에 설치되는 비상발전기의 용량산정 방식에 대하여, NEGA C 201 방식을 적용할 때 필요한 동시시동그룹의 구성과 수용률의 적용 방법을 제시하였으며, 대상부하를 "정전시 부하"와 "화재시 부하"로 구분하여 계산할 것을 제안하였다. 아울러, 500호~1,500호 정도의 대.중.소 규모 공동주택 단지를 대상으로 비상발전기의 용량을 산출하고 실측 결과와의 비교를 통해 본 연구의 제시 방안이 타당함을 입증하였다. 또한, 본 연구에 의한 비상발전기 설계용향은 NEGA C 201 방식에 의한 엔진용량 및 기존방식에 의한 엔진용량과 잘 적합되는 것으로 나타났다.용량과 잘 적합되는 것으로 나타났다.

  • PDF

FTA기법에 의한 원전기동전원의 이용율 예측에 관한 연구 (A Study on the Availability Prediction of Start-up Power Supply in Nuclear Power Plant by FTAMethod)

  • 최규식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권5호
    • /
    • pp.517-523
    • /
    • 1999
  • The Start-up transformers or on-site stand-by transformers are installed for the start-up and shut-down of generator and emergency status in unclear power plant. The on-site power supply configuration using these transformers must be detemined by considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and benefit of plant. The start-up or stand-by power supply configuration has been determined considering only safety requirements and construction cost up to now in Korea. I study various reliability estimating methods for the prediction of availability, and estimate the unavailability for the start-up power supply system of two 1,000㎿ unclear power plants. I also detemine the reliability and unavailability and unavailavility of equipment, system and configuration using FTA method.

  • PDF

원전 비상디젤발전기 신뢰도 관리시스템 개발 (Development of Reliability Management System of Emergency Diesel Generator for Nuclear power plants)

  • 송재주;이정일;신진호;강주영;이봉재
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2005년도 한국컴퓨터종합학술대회 논문집 Vol.32 No.1 (B)
    • /
    • pp.115-117
    • /
    • 2005
  • 본 논문은 원자력발전소 비상디젤발전기의 신뢰도 및 성능변화 추이를 감시하고, 이에 필요한 데이터를 관리하는 비상디젤발전기 신뢰도 프로그램 개발에 관하여 기술하였다. 이 프로그램은 인트라넷 기술을 이용하여 신뢰도 감시, 성능 감시, 그리고 관련정보로 크게 3가지 모듈로 구분하여 개발하였다. 현재 이를 통하여 원전 비상디젤발전기의 운전 및 정기점검 데이터를 입력 관리할 수 있도록 서비스를 개시하였으며, 이미 기존에 입력된 데이터를 이용하여 신뢰도 및 이용 불능도를 계산할 수 있고 또한 성능변화 추이를 감시할 수 있다.

  • PDF

비상전원 기능을 갖는 하이브리드 에너지저장시스템 표준화 기술 (Hybrid Energy Storage System with Emergency Power Function of Standardization Technology)

  • 홍경진
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권2호
    • /
    • pp.187-192
    • /
    • 2019
  • 수요관리와 정전에 대한 비상전원 기능을 갖춘 하이브리드 전력저장시스템으로 비상발전설비가 필요한 빌딩 및 공장건축 시에 투자비를 최소화하고, 상시 전력비를 절감함으로서 경제성을 확보할 수 있 기술을 개발함으로써 새로운 비즈니스 모델을 제시한다. 평상시에 STS(Static Transfer Switch)를 통해 부하에 계통 전력을 공급하고 PCS는 계통에 병렬로 연계되어 수요관리를 수행한다. EMS는 수요예측을 통한 전력의 효율적 운용을 위해 ESS에 충방전 지령을 PMS(Power Management System)로 하달하고 PMS는 다시 PCS 제어기로 지령을 전달하여 시스템을 운용한다. 정전시에는 STS가 계통으로부터 빠르게 이탈되면서 PCS는 독립 전원이 되어 부하 측에 정전압/정주파수의 전력을 공급할수 있는 구조이다. 따라서 하이브리드 ESS에 대한 실 계통 연계 및 독립 운전 성능 검증을 통한 신뢰성을 확보할수 있고, 저탄소 녹색성장 기술의 효율적 전력망과 연계 운영이 가능하게 함으로써 ESS 연계를 통한 신재생에너지 발전에 의한 불규칙한 전력 품질개선, 피크부하 기여도 제고가 가능하다. 또한 현재 석탄 화력이 담당하고 있는 주파수추종 예비력을 ESS로 대체함에 따라 연료비가 높은 LNG 발전기 가동비용을 절감할 수 있는 기대효과가 있다.

자가발전용 휴대폰 케이스에 관한 연구 (Study on the mobile phone case for self-power generation)

  • 김진호;박창형;한승철
    • 한국산학기술학회논문지
    • /
    • 제18권6호
    • /
    • pp.8-12
    • /
    • 2017
  • 본 논문에서는 휴대폰의 배터리 방전 시에도 비상전화나 문자 메시지의 사용을 가능하게 해주는 자가발전기에 관한 연구를 진행하여 휴대폰 케이스를 통한 휴대폰의 재충전 방법을 제시한다. 사용자가 스마트 폰 케이스를 흔들게 되면 전자기 코일과 발전기의 영구 자석의 상호 작용을 통해 리튬 이온 배터리를 충전 하며 전기 에너지가 생성된다. 이 때 생성된 전기에너지는 사용자가 몇 분의 통화 또는 문자 메시지를 사용할 수 있는 전력을 제공 해준다. 또한 사람이 걸을 때 위상의 변화에 의해 2 ~ 3 Hz 주파수의 진동 에너지가 발생하는데, 이를 획득하는 에너지 하베스팅 과정을 통해 배터리를 충전한다. 그리고 발전량을 분석하는 것은 상용 전자기 해석 프로그램인 MAXWELL을 사용하여 모델링 후 시뮬레이션 하였다. 마지막으로 분석한 결과를 바탕으로 자가 발전을 위한 휴대폰 케이스의 프로토타입을 구축하고 그 측정값과 시뮬레이션 값을 비교함으로써 프로토타입의 성능을 검증하였다.