• 제목/요약/키워드: Emergency Evacuation

검색결과 301건 처리시간 0.02초

M&S를 통한 비상대피시설의 적정 출입구 개수 산정에 관한 연구 (A Study on the Estimation of the Number of Suitable Entrances for Emergency Evacuation Facilities through Modeling and Simulation)

  • 이정문;노정헌;박영준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.129-130
    • /
    • 2019
  • In this research, we determine the proper number of entrances in the evacuation facilities for civil and military personnel. The current standards on the emergency evacuation facility only sets the number of possible evacuees and the according architectural floor area since the evacuation have been completed. However, other than static standards such as the floor area, there is needs to consider the dynamic standards along with allowable evacuation time such as the number of entrance, staircases and so on. Therefore, we need to consider the number of entrances and their location in order to account for the allowed evacuation time of particular number of people in a set area. The outcome could be contributed to the standards which should contain the dynamic conditions associated with evacuation.

  • PDF

Real-time Intelligent Exit Path Indicator Using BLE Beacon Enabled Emergency Exit Sign Controller

  • Jung, Joonseok;Kwon, Jongman;Jung, Soonho;Lee, Minwoo;Mariappan, Vinayagam;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • 제6권1호
    • /
    • pp.82-88
    • /
    • 2017
  • Emergency lights and exit signs are an indispensable part of safety precautions for effective evacuation in case of emergency in public buildings. These emergency sign indicates safe escape routes and emergency doors, using an internationally recognizable sign. However visibility of those signs drops drastically in case of emergency situations like fire smoke, etc. and loss of visibility causes serious problems for safety evacuation. This paper propose a novel emergency light and exit sign built-in with Bluetooth Low Energy (BLE) Beacon to assist the emergency self-guiding evacuation using devices for crisis and emergency management to avoid panic condition inside the buildings. In this approach, the emergency light and exit sign with the BLE beacons deployed in the indoor environments and the smart devices detect their indoor positions, direction to move, and next exit sign position from beacon messages and interact with map server in the Internet / Intranet over the available LTE and/or Wi-Fi network connectivity. The map server generate an optimal emergency exit path according to the nearest emergency exit based on a novel graph generation method for less route computation for each smart device. All emergency exit path data interfaces among three system components, the emergency exit signs, map server, and smart devices, have been defined for modular implementation of our emergency evacuation system. The proposed exit sign experimental system has been deployed and evaluated in real-time building environment thoroughly and gives a good evidence that the modular design of the proposed exit sign system and a novel approach to compute emergency exit path route based on the BLE beacon message, map server, and smart devices is competitive and viable.

Benefits from Utilizing A Conceptual Model of Indoor GIS Based Evacuation Information System

  • Luo, Wen-Yuan;Ahn, Byung-Ju;Kim, Jae-Jun;Lee, Gwang-Gook;Kim, Whoi-Yul
    • 한국건설관리학회논문집
    • /
    • 제10권5호
    • /
    • pp.148-157
    • /
    • 2009
  • When an emergency situation happens in buildings, the top priority is to ensure the occupant from danger as soon as possible. Achieving that goal is a multifaceted and difficult task. However, current evacuation systems have many deficiencies in dealing with the emergency in multi-level structures. The shortage of abilities to continuously update database, predict the future situation and provide the information to users with contextual information is the limit in current systems. Thus, it is very crucial to introduce Evacuation Information System (EIS), which is able to respond quickly to the emergency, and transfer the information to both the administrator and the occupant. The main purpose of this paper is to build EIS on the basis of the indoor Geographical Information System (GIS). When the emergency happens, EIS gives the instruction to Emergency Response Model (ERM) at once. ERM carries out the order and calculates the optimal evacuation routes, then sends the result to EIS. At last, EIS transmits evacuation messages to the occupant who implements evacuation plan. This paper highlights the benefits of EIS in two aspects. One is that EIS can update the data continuously to support evacuation strategy-making. The other is that it can transmit evacuation messages to both the administrator and the occupant.

대피장애 행동특성을 반영한 비상사태 피난 시뮬레이터 개발 연구 (A Study on the Development of Emergency Evacuation Simulator Considering the Characteristic of the Behavior Pattern in Crowding)

  • 리송준;이상현
    • 한국산학기술학회논문지
    • /
    • 제9권5호
    • /
    • pp.1319-1327
    • /
    • 2008
  • 비상시 대피 상황을 분석하기 위한 다양한 종류의 시뮬레이터 개발 관련 연구가 있어왔다. 하지만 주목할만한 것은 비상사태에서 과밀로 인한 대피장애 행동특성을 고려한 연구는 아주 미미하다는 점이다. 본 연구는 화재와 같은 비상사태 시 과밀공간에서 생기는 재실자간의 충돌, 짓밟음 등과 같은 대피장애 행동특성을 반영하는 비상사태 피난 시뮬레이터(EAS: Evacuation Agent Simulator)를 개발하여 건조물 내에서 과밀로 인한 대피장애를 예측함으로써 피난계획 수립에 필요한 정보를 제공하는 것을 목적으로 하고 있다.

병원 외래진료부에서의 피난 과밀 공간 분석 모델에 관한 연구 (A Space Analysis Model of Evacuation Overcrowding at Hospital Outpatient Department)

  • 이주희;권지훈
    • 대한건축학회연합논문집
    • /
    • 제21권3호
    • /
    • pp.109-116
    • /
    • 2019
  • This study aimed to suggest a quantitative model analyzing overcrowding area under emergency evacuation situation in the outpatient department of hospital. Overall study process included the review on legal conditions of an emergency evacuation, the investigation of precedent research documents and the analysis of spatial configuration. The user movement with considering exit gates and the one without considering exit gates were analyzed for routine activity condition. An agent-based simulation was applied for the analysis. Also, user movement for the emergency condition was tested with evacuation simulation. The variation of simulation conditions revealed the difference between overcrowding spaces from situation change. At all nodes, visit frequencies derived from different conditions and situations were compared. The overcrowding spaces are to increase the risk of delaying emergency evacuation time which is critical for user safety. It suggests the need for dispersing overcrowding spaces under evacuation situation. The suggested analysis model can evaluate overcrowding spaces in the outpatient department of hospital and provide locational data for distributing evacuation design resources.

Evaluation of Evacuation Safety in University Libraries Based on Pathfinder

  • Zechen Zhang;Jaewook Lee;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권2호
    • /
    • pp.237-246
    • /
    • 2024
  • In recent years, the frequent occurrence of fire accidents in university libraries has posed significant threats to the safety of students' lives and property, alongside negative social impacts. Accurately analyzing the factors affecting evacuation during library fires and proposing optimized measures for safe evacuation is thus crucial. This paper utilizes a specific university library as a case study, simulating fire evacuation scenarios using the Pathfinder software, to assess and validate evacuation strategies and propose relevant optimizations. Pathfinder, developed by Thunderhead Engineering in the United States, is an intuitive and straightforward personnel emergency evacuation assessment system, offering advanced visualization interfaces and 3D animation effects. This study aims to construct evacuation models and perform simulation analysis for the selected university library using Pathfinder. The library's structural layout, people flow characteristics, and the nature of fire and smoke spread are considered in the analysis. Additionally, evacuation scenarios involving different fire outbreak locations and the status of emergency exits are examined. The findings underscore the importance of effective evacuation in fire situations, highlighting how environmental conditions, individual characteristics, and behavioral patterns significantly influence evacuation efficiency. Through these investigations, the study enhances understanding and optimization of evacuation strategies in fire scenarios, thereby improving safety and efficiency. The research not only provides concrete and practical guidelines for building design, management, and emergency response planning in libraries but also offers valuable insights for the design and management of effective evacuation systems in buildings, crucial for ensuring occupant safety and minimizing loss of life in potential hazard situations

Implementation of Occupant Density and Walking Pattern Measurement for Emergency Evacuation and Safety in High-Rise Multi-Purpose Facilities

  • Lee, Myung Sik
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.409-415
    • /
    • 2018
  • Recently, many countries around the world began to show interest in safety against terrorism, fire, and natural disasters. This study aimed to propose a quantitative measurement system for emergency evacuation and safety for various kinds of terrorism and fire within high-rise multi-purpose facilities, which can measure the pedestrians' ordinary walking patterns in the concourse with the highest pedestrian volume out of all the spaces within multi-story buildings, predict pedestrians' evacuation walking lines when a sudden disaster breaks out, and analyze the gait coefficient, occupant density, and evacuation behavior time.

하향식 피난구의 경제성 및 피난 소요시간 분석 (Economic and Evacuation Time Analysis of Horizontally-installed Indoor Emergency Exit)

  • 유월;김선국;김기혁;이동훈
    • 한국건축시공학회지
    • /
    • 제18권4호
    • /
    • pp.363-373
    • /
    • 2018
  • 고층 공동주택에서 화재시 현관문을 통해 탈출이 불가능할 경우를 대비해 발코니를 통해 피난이 가능하도록 피난시설을 설치한다. 이는 공동주택 세대의 양방향 피난이 가능하게 하며, 이로 인해 인명피해를 줄일 수 있다. 본 연구에서는 양방향 피난시설인 경량 칸막이, 발코니 대피 공간, 실내형 하향식 피난구의 특징을 살펴보고 이들의 문제점을 개선한 실외형 하향식 피난구를 제시하고 경제성에 대해 분석하였다. 화재 발생 시 피난자는 전통식 피난구를 사용할 때보다 하향식 피난구를 사용할 때 능동적인 탈출 가능 여부를 더 자율적으로 판단 할 수 있다. 따라서 피난자의 피난방식에 따라 피난소요시간에 미치는 영향을 고려하여 계단식과 하향식 피난구를 통한 4가지 피난방식의 피난 소요시간은 시뮬레이션 pathfinder를 활용하여 비교분석하였다. 피난 소요 시간 단축을 위한 적합한 대피방식을 예측 분석 판단하였다. 본 연구의 결과 고층 아파트 하향식 피난구는 계단식보다 총 피난소요시간을 단축할 수 있는 것으로 분석되었다.

Analysis of University Cafeteria Safety Based on Pathfinder Simulation

  • Zechen Zhang;Jaewook Lee;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권2호
    • /
    • pp.209-217
    • /
    • 2024
  • Recent years have seen a notable increase in fire incidents in university cafeterias, yet the social attention to these occurrences remains limited. Despite quick responses to these incidents preventing loss of life, the need for large-scale evacuation in such high foot traffic areas can cause significant disruptions, economic losses, and panic among students. The potential for stampedes and unpredictable damage during inadequate evacuations underscores the importance of fire safety and evacuation research in these settings. Previous studies have explored evacuation models in various university environments, emphasizing the influence of environmental conditions, personal characteristics, and behavioral patterns on evacuation efficiency. However, research specifically focusing on university cafeterias is scarce. This paper addresses this gap by employing Pathfinder software to analyze fire spread and evacuation safety in a university cafeteria. Pathfinder, an advanced emergency evacuation assessment system, offers realistic 3D simulations, crucial for intuitive and scientific evacuation analysis. The studied cafeteria, encompassing three floors and various functional areas, often exceeds a capacity of 1500 people, primarily students, during peak times. The study includes constructing a model of the cafeteria in Pathfinder and analyzing evacuation scenarios under different fire outbreak conditions on each floor. The paper sets standard safe evacuation criteria (ASET > RSET) and formulates three distinct evacuation scenarios, considering different fire outbreak locations and initial evacuation times on each floor. The simulation results reveal the impact of the fire's location and the evacuation preparation time on the overall evacuation process, highlighting that fires on higher floors or longer evacuation preparation times tend to reduce overall evacuation time.In conclusion, the study emphasizes a multifaceted approach to improve evacuation safety and efficiency in educational settings. Recommendations include expanding staircase widths, optimizing evacuation routes, conducting regular drills, strengthening command during evacuations, and upgrading emergency facilities. The use of information and communication technology for managing emergencies is also suggested. These measures collectively form a comprehensive framework for ensuring safety in educational institutions during fire emergencies.

학교강당의 평면적 특징에 따른 대피효율에 관한 연구 (Evacuation Efficiency on School Auditorium Floor Layout)

  • 권준범;김덕수;김길채
    • 교육시설 논문지
    • /
    • 제24권2호
    • /
    • pp.3-10
    • /
    • 2017
  • This study compared evacuation effectiveness between the conventional school auditorium plan and a suggested hypothetical plan that was generated by a mathematical model, which is commonly applied in the field of industrial engineering. Recent school buildings became much more complicated in floor planning due to new social needs and modern curriculum than the old days. Nevertheless, architect's approach to floor composition in terms of fire emergency evacuation planning, still has no relation to optimized effective but relies more on an conventional school planning. Therefore, since school buildings are much more likely to be exposed to any fire related events than any other building types, emergency exit effectiveness based on spatial composition has to be seriously evaluated with a scientific method. The algorithm, which acquires the number of persons in each spatial type(node) per floor and the minimum physical distance between spatial types(arc), can propose the most optimized spatial layout per floor regarding emergency evacuation event. Consequently, this study evaluated school's fire exit effectiveness focusing on auditorium area with the scientific tool and suggested the most reliable spatial layout regarding possibile emergency evacuation event.