• Title/Summary/Keyword: Embedded data

Search Result 2,138, Processing Time 0.032 seconds

Effects of dye-guidance brushing etching technique on the performance of pits and fissures sealant (Dye-guidance와 brushing을 통한 산부식 방법이 치면열구전색술의 수복의 질에 미치는 영향)

  • Hung, Phan Ai;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.106-121
    • /
    • 2007
  • The purpose of this study was to examine the effects of suggested etching method on the performance of pits and fissures sealant. In the first part, seventy extracted sound human permanent third molars and premolars were used. The teeth were randomly divided and performed in three different groups as follows : conventional etching, enameloplasty, and testing group. Non-pumicing, dye-guidance vigorous brushing-start etching technique was applied on the occlusal of testing group. Then the pit and fissure sealant was applied on all of the specimens. After the thermocycling and immersing in 1% methylene blue, the resin embedded sections were made. The microleakage data on the section were then recorded under the stereoscope and statistic analysis was done. Additional experiments were also performed : direct fissure surface etched pattern experiment, replica study, and micro-shear bond strength testing observation. The second part included two groups. A paired study was designed to evaluate the influence the environment has on the performance of the sealant. After etching, half of each occlusal surface received one of the two following treatments in succession: sealing in laboratory and intraoral condition (group 1), sealing in intraoral condition with and without a single-bonding agent (group 2). The results of present study can be summarized as follows: - The microleakage of testing group was significant different with conventional method (P<.05) and was not different with the enameloplasty group (P>.05). - The quality and quantity of etched enamel were improved. - Microshear bond strength of testing group was higher than control group (p<.05). - The environmental condition was influenced on the performance of the sealant. The testing etching method modified the capacity of the etching agent to penetrate into the pits and fissures, and simultaneous enhance their efficiency in vitro condition.

  • PDF

A STUDY ON THE SHEAR BOND STRENGTH OF LIGHT CURED GLASS IONOMER CEMENTS TO CONTAMINATED DENTIN (상아질 표면상태에 따른 광중합형 글래스아이오노머 시멘트의 전단결합강도에 관한 연구)

  • Kim, Kyoung-Hwa;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.609-621
    • /
    • 1997
  • The purpose of this study was to evaluate the shear bond strength of three light-cured glass ionomer cements to blood contaminated bovine dentin. The materials used in this study were Fuji II LC, Dyract and Variglass VLC. The dentin conditioners were 10% polyacrylic acid, 10% maleic acid and 10% phosphoric acid. 180 lower anterior bovine teeth were selected in this study. The teeth were embedded in acrylic resin and were grounded with 320 to 600 grit silicon carbide paper to create a flat dentin surface. The teeth were divided into SIX groups. The experimental procedures in six groups were as follows; Group l(GF) : Samples bonded to dentin surface with Fuji II LC after 10% polyacrylic acid treatment. Group 2(BGF) : Samples bonded to dentin surface with Fuji II LC after 10% polyacrylic acid treatment and blood contamination. Group 3(MD) : Samples bonded to dentin surface with Dyract after 10% maleic acid treatment. Group 4(BMD) : Samples bonded to dentin surface with Dyract after 10% maleic acid treatment and blood contamination. Group 5(PV) : Samples bonded to dentin surface with Variglass VLC after 10% phosphoric acid treatment. Group 6(BPV) : Samples bonded-to dentin surface with Variglass VLC after 10% phosphoric acid treatment and blood contamination. Group 1,3 and 5 were classified into the control groups, while group 2,4 and 6 were classified into the experimental groups. Each group contained 30 samples. After 24 hours water storage at $37^{\circ}C$, all smples were subjected to a shear load to fracture at a cross head speed of 1.0 mm/min with Instron universal testing machine(No. 4467). Debonded surfaces were observed under Scanning Electron Microscope(Hitachi S-2300) at 20kvp. The data were evaluated statistically at the 95% confidence level with Student's t-test. The following results obtained; 1. Shear bond strengths were higher in the control groups(1,3,5 group) than in the experimental groups(2,4,6 group). 2. The shear bond strength of group 5(PV) was the highest in the control groups, and the group 5 was significantly higher than the group l(GF) on the shear bond strength. 3. The group 4(BMD) was the highest on the shear bond strength, and the group 2(BGF) was the lowest in the experimental groups. The group 4(BMD) and 6(BPV) showed a significant difference with the group 2 on the shear bond strength. 4. All the groups showed an adhesive-cohesive failure. except the group 2(BGF) showing adhesive failure.

  • PDF

Fostering Entrepreneurship by Maker Education: A Case Study in an Higher Education (메이커 교육(Maker Education)을 통한 기업가정신 함양:대학교 사례연구)

  • Kang, In-Ae;Kim, Yang-Soo;Yoon, Hyea-Jin
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.7
    • /
    • pp.253-264
    • /
    • 2017
  • The advent of the $4^{th}$ industrial Revolution requires entrepreneurship to the student as one able to produce creative solutions of complex problems embedded in society with active engagement. Maker Education indicates a new educational approach in which students produce a tangible output as a concrete solution to their problems, experiencing spirits of productive failure, sharing and openness with others during the process due to its educational values and effects which are well-matched with entrepreneurship. This study, in this context, aimed to verify the effect of the maker education in the sense of cultivating entrepreneurship: For this purpose, this study conducted a case study of Maker Education to 56 university students during 7 weeks (14 hours) in K university. The results based upon data analysis collected from reflective journals and interviews showed attitude change of the students in terms of entrepreneurship characterized as self-directedness, risk-taking, and creativity. For more active practices of Maker Education in higher education, both instructors' role as the facilitator, and easily and freely accessible Maker Space should be considered.

Effect of Provisional Restorative and Filling Materials on Bond Strength of Adhesive Resin Cement between Lithium Disilicate Glass-Ceramic and Dentin (Lithium Disilicate Glass-ceramic과 상아질 간의 접착성 레진 시멘트의 결합강도에 대한 임시 수복재와 임시 충전재의 영향)

  • Oh, Sang-Chun;Sim, Hun-Bo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.359-365
    • /
    • 2013
  • The aim of this study was to evaluate the effect of temporary restorative and filling material on bonding strength between lithium disilicate glass-ceramic and dentin. 60 extracted human molars were cross-sectioned at occlusal third and were embedded into self-cure acrylic resin. Then the teeth were randomly divided into four groups of 15 each. Lithium disilicate glass-ceramic is cemented to dentin as follows: after no any application of the provisional materials (Group A), after application of ALIKETM (GC America Inc.)(Group B), after application of Luxatemp$^{(R)}$ Automix plus (DMG, Germany)(Group C), after application of Fermit$^{(R)}$ (Ivoclar Vivadent, Leichtenstein)(Group D). After the specimens were stored in distilled water for 24 hours, the shear bond strength of the specimens were measured using UTM (Zwick 1456 41, Zwick, Germany) at a crosshead speed of 1mm/min. The data were analysed by one-way ANOVA and Tukey HSD tests. There were no statistically significant differences of bond strength among the groups. Fracture type was showed mixed type of adhesive and cohesive fracture in most of specimens. Within the limitation of this study, bond strength of adhesive resin cement between lithium disilicate glass-ceramic and dentin was not affected by provisional restorative and filling materials.

A study of Tumor Angiogenesis in Human Lung Cancer by Immunohistochemical Stain (Human Lung Cancer에서 면역세포화학적 방법을 이용한 Tumor Angiogenesis에 관한 연구)

  • Cheon, Seon Hee;Kim, Sung Sook;Rha, Sun Young;Chung, Hyun Cheol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.894-902
    • /
    • 1996
  • Background : Tumor angiogenesis is the growth of new vessels toward and within tumor. It has been demonstrated that the growth of tumor beyond a certain size requires angiogenesis and it is closely involved in tumor progression and metastasis. The finding that intensity of neovascularization correlates independently with metastasis may lead to identification of patients in whom radical surgery should be supplemented by systemic treatment. Method : We have collected paraffin blocks of bronchoscopic biopsy of patients with non-small cell lung cancer. We highlighted the vessel by staining endothelial cell with JC70 monoclonal antibody(to CD31) immunohistochemically and counted microvessels under 200 X field using light microscopy. Results : 1) The mean microvessel count was $32.7{\pm}20.8$ (9-96) in total 29 cases. 2) There were no correlations between microvessel counts and pathologic cell type, T staging, node melastasis(N) and hematogenous metastasis(M) (p>0.05). 3) The median follow-up duration was 15 months(2-46) and there was no correlation between the microvessel counts and survival rate of lung cancer patients (p>0.05). Conclusion : Tumor angiogenesis seems to be an important prognostic factor suggesting the probability of metastasis. But the microvessel count in the bronchoscopic biopsy specimen was inadequate and very limited. There has been no data about angiogenesis of lung cancer in korea yet So the study of tumor angiogenesis using resected lung tumor specimen would be demanded.

  • PDF

Recognition and Performance of Patient Private Information Protection (PPIP) in Nursing Students (환자 개인정보보호에 대한 간호대학생의 인식과 실천)

  • Kim, Chang-Hee;Jeong, Sun-Young;Song, Yong-Shin
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.479-490
    • /
    • 2013
  • In this research we surveyed level of textual recognition and of practice by nursing students regarding patient privacy protection. The subjects were 383 nursing students. The questionnaire developed by Lee and Park (2005) were modified and used. Data analysis was conducted through descriptive statistics, t-test, ANOVA, and Pearson correlation coefficients. The result shows that about 96.1% of the subjects received education on patient privacy protection in school or hospital but 48.0% of all received education of 10 minutes or less. Average score for recognition of patient privacy protection was a 4.13 but average practice score was 3.84. Among all areas, communication tasks showed the highest scores for both recognition and practice. There are differences according to grade in school and age of the subject, and experience with clinical practice, existence of regular educational program embedded in clinical practice at hospitals, and the length of each educational session. For both total score and score for every domain, there was a correlation between recognition and practice. The conclusions drawn from this research will help colleges of nursing and hospitals to design and develop contents of educational programs for nursing students.

Site Monitoring of Crews and Passengers on Board by the BLE and PLM Combination (BLE와 PLM 조합의 승선자 위치 모니터링)

  • Kwon, Hyuk-Joo;Yang, Hyun-Suk;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.463-467
    • /
    • 2015
  • When unforeseen accidents occur in a ship, it is important to save passengers safely and remove them from the accident area quickly. To solve such a situation, site information of passengers on board always must be identified. This paper implemented a site monitoring of crews and passengers based on the BLE and PLM combination, to prepare for unexpected accidents of the ships. This system was composed of BLE tag for crews, passengers and each room, PLM networks, data server, and monitoring PC. In this system, site information derived from the tag attached to the bodies and cabins of crews and passengers are transmitted through a power line network, and monitored on the screen of a monitoring PC. The proposed system guides them into the only authorized area considering the ship security and passengers' safety, and even has a special alarm call to warn them after entering an unauthorized area. This system enables the BLE-embedded tag battery to use for a long time because the BLE consumes low electric power, and can gain an economic advantage.

In Vivo Dosimetry with MOSFET Detector during Radiotherapy (방사선 치료 중 MOSFET 검출기를 이용한 체표면 선량측정법)

  • Kim Won-Taek;Ki Yong-Gan;Kwon Soo-Il;Lim Sang-Wook;Huh Hyun-Do;Lee Suk;Kwon Byung-Hyun;Kim Dong-Won;Cho Sam-Ju
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.17-23
    • /
    • 2006
  • In Vivo dosimetry is a method to evaluate the radiotherapy; it is used to find the dosimetric and mechanical errors of radiotherapy unit. In this study, on-line In Vivo dosimetry was enabled by measuring the skin dose with MOSFET detectors attached to patient's skin during treatment. MOSFET dosimeters were found to be reproducible and independent on beam directions. MOSFET detectors were positioned on patient's skin underneath of the dose build-up material which was used to minimize dosimetric error. Delivered dose calculated by the plan verification function embedded in the radiotherapy treatment planning system (RTPs), was compared with measured data point by point. The dependency of MOSFET detector used in this study for energy and dose rate agrees with the specification provided by manufacturer within 2% error. Comparing the measured and the calculated point doses of each patient, discrepancy was within 5%. It was enabled to verify the IMRT by using MOSFET detector. However, skin dosimetry using conventional ion chamber and diode detector is limited to the simple radiotherapy.

  • PDF

Spatial Characters of Workplace and Everyday Life of Immigrant Workers in S. Korea (한국 이주노동자의 일터와 일상생활의 공간적 특성)

  • Choi, Byung-Doo
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.319-343
    • /
    • 2009
  • This paper considers some kinds of socio-spatial constraints and strategies for overcoming them which immigrant workers in Korea have experienced in their work-place and life-space, with an analysis of questionnaire data and of direct interview materials on them. Though they appear somewhat satisfactory or positive with their work-place, this can be seen as a hypocritical or false attitude rather than a real one: they are forced to work with long hours (more than 70 hours per week) and rigid controls in the other' territory. Their daily life-spaces also are severe: they can be hardly embedded in an existing community with a sense of place due to serious institutional and interaction constraints, even though they seem to have a basic mobility to survive in life-spaces. In order to escape or alleviate such local constraints, they try to constitute multi-scalar (local, trans-regional, and transnational) networks, and to find informations and means to resolve or cope with them. However, this kind of endeavors of immigrant workers to make a trans-national network and social space has a limitation for them to be free entirely from constraints, which might be strengthened with a lack of geographical knowledge of them. Then immigrant workers in Korea live ineluctably with not only hybrid national identity but also with disturbed local identity in an aliened workplace and life-spaces.

  • PDF

Design of an $SpO_2$ Transmission Agent based on ISO/IEEE 11073 Standard Protocol (ISO/IEEE 11073 표준 프로토콜 기반의 산소포화도 전송 에이전트 설계)

  • Pak, Ju-Geon;Im, Sung-Hyun;Park, Kee-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.462-465
    • /
    • 2011
  • A pulse oximeter is a device which provides non-invasive estimate of percentage oxygen saturation of haemoglobin (SpO2). Due to the limitations of resources of personal health devices (PHDs) including pulse oximeters, they generally transmit the estimated data to a remote monitoring server through a close manager (e.g. mobile device or PC). Therefore, communication protocols between PHDs and a manager is an important research topic in terms of interoperability. In this paper, we present design results of an SpO2 transmission agent based on the ISO/IEEE 11073 (X73) protocol. The protocol is an international standard for PHDs. The agent is an embedded program which generates X73 messages from the estimated pulse rates and SpO2, and transmits the messages to a close manager. The agent consists of a Session, Message and Memory Handler. The Session Handler manages a communication session with the manager, and the Message Handler generates and analyzes the exchanged messages according to the X73 protocol. The Memory Handler extracts pulse rates and SpO2s which are stored in a memory of the pulse oximeter. The SpO2 transmission agent allows pulse oximeters to communicate with managers based on x73 standard. Consequently, the interoperability between the pulse oximeters and the managers is guaranteed.

  • PDF