• Title/Summary/Keyword: Elevation Angle

Search Result 346, Processing Time 0.035 seconds

Development of Elbow Joint X-ray Examination Aid for Medical Imaging Diagnosis (의료영상 진단을 위한 팔꿉관절 X-선 검사 보조기구 개발)

  • Hyeong-Gyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.127-133
    • /
    • 2024
  • The elbow joint is made up of three different bones. X-rays or other radiological exams are commonly used to diagnose elbow injuries or disorders caused by physical activity and external forces. Previous research on the elbow joint reported a new examination method that meets the imaging evaluation criteria in the tilt position by Z-axis elevation of the forearm. Therefore, this study aims to design an optimized instrument and develop an aid applicable to other upper extremity exams. After completing the 2D drawing and 3D modeling design, the final design divided into four parts was fabricated with a 3D printer using ABS plastic and assembled. The developed examination aid consists of a four-stage Z-axis elevation tilt angle function (0°, 5°, 10°, and 15°) and can rotate and fixate 360° in 1-degree increments. It was designed to withstand a maximum equivalent stress of 56.107 Pa and a displacement of 1.6548e-5 mm through structural analysis to address loading issues caused by cumulative frequency of use and physical utilization. In addition to X-ray exams of the elbow joint, the developed aid can be used for shoulder function tests by rotating the humerus and also be applied to MRI and CT exams as it is made of non-metallic materials. It will contribute to the accuracy and efficiency of medical imaging diagnosis through clinical applications of various devices and medical imaging exams in the future.

Bit Error Bounds for Trellis Coded Asymmetric 8PSK in Rain Fading Channel (강우 페이딩 채널에서 비대칭 8PSK 트랠리스 부호화방식의 비트에러 상한 유도)

  • 황성현;최형진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5B
    • /
    • pp.797-808
    • /
    • 2000
  • This paper presents the bit error rate(BER) upper bounds for trellis coded asymmetric 8PSK(TC-A8PSK) system using the Ka-band satellite in the rain fading environment. The probability density function(PDF) for the rain fading random variable can be theoretically derived by assuming that the rain attenuation can be approximated to a long-normal distribution and the rain fading parameters are calculated by using the rain precipitation data from the Crane global model. Furthermore, we analyze the BER upper bounds of TC-A8PSK system according to the number of states in the trellis diagram and the availability of channel state information(CSI). In the past, Divsalar and Simon[9] has analyzed the BER upper bounds of 2-state TCM system in Rician fading channels however this paper is the first to analyze the BER upper bounds of TCM system in the rain fading channels. Finally, we summarize the dominant six factors which are closely related to the BER upper bounds of TC-A8PSK satellite system in the rain fading channel as follows: 1) frequency band, 2) rain intensity, 3) elevation angle, 4) signal to noise ratio, 5) asymmetric angle, and 6) availability of CSI.

  • PDF

Development of Cloud Amount Calculation Algorithm using MTSAT-1R Satellite Data (MTSAT-1R 정지기상위성 자료를 이용한 전운량 산출 알고리즘 개발)

  • Lee, Byung-Il;Kim, Yoonjae;Chung, Chu-Yong;Lee, Sang-Hee;Oh, Sung-Nam
    • Atmosphere
    • /
    • v.17 no.2
    • /
    • pp.125-133
    • /
    • 2007
  • Cloud amount calculation algorithm was developed using MTSAT-1R satellite data. The cloud amount is retrieved at 5 km ${\times}$ 5 km over the Korean Peninsula and adjacent sea area. The algorithm consists of three steps that are cloud detection, cloud type classification, and cloud amount calculation. At the first step, dynamic thresholds method was applied for detecting cloud pixels. For using objective thresholds in the algorithm, sensitivity test was performed for TBB and Albedo variation with temporal and spatial change. Detected cloud cover was classified into 3 cloud types (low-level cloud, cirrus or uncertain cloud, and cumulonimbus type high-level cloud) in second step. Finally, cloud amount was calculated by the integration method of the steradian angle of each cloud pixel over $3^{\circ}$ elevation. Calculated cloud amount was compared with measured cloud amount with eye at surface observatory for the validation. Bias, RMSE, and correlation coefficient were 0.4, 1.8, and 0.8, respectively. Validation results indicated that calculated cloud amount was a little higher than measured cloud amount but correlation was considerably high. Since calculated cloud amount has 5km ${\times}$ 5km resolution over Korean Peninsula and adjacent sea area, the satellite-driven cloud amount could show the possibility which overcomes the temporal and spatial limitation of measured cloud amount with eye at surface observatory.

Kinematical Analysis of Tippelt Motion in Parallel Bars (평행봉 Tippelt 동작의 기술 분석)

  • Back, Hun-Sik;Kim, Min-Soo;Moon, Byoung-Yong;Back, Jin-Ho;Yoon, Chang-Sun
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.167-176
    • /
    • 2007
  • The purpose of this study was to offer suitable model for performing Tippelt motion and data for training Tippelt motion through the quantitative kinematical analysis of Tippelt motion in parallel bars. The results of analysing kinematic variations through three-dimensional reflection analysis of three members of the national team as the objects of the study were shown as follows. 1. It seemed that the shoulder-joints which are stretched as much as possible affects the whole Tippelt motion while one is swinging downward. The time of process of the center of mass for the body reaching to the maximum flection point should be quick and body's moving from the vertical phase to the front direction should be controled as much as possible. 2. While one is swinging upward, the stability of flying motion could be made certain by the control of body's rapid moving to the front direction and stretching shoulder-joints and hip-joint to reverse direction. 3. While one is flying upward, the body should be erected quickly and lessening the angle of the hip-joint affects the elevation of flight. When the powerful counter turn motion is performed, the stable motion could be made. As a result of this study, It seems that sudden fall and the maximum stretch of shoulder-joints is important during performing Tippelt motion in parallel bars. Also, it concludes that the maximum bending of hip-joints at the starting point of upward swing, sudden stretch to the reverse direction of shoulder-joints and hip-joints when one is leaving bars, control of body's moving to the front direction, and lessening the angle of hip-joints at the flying phase is important.

Distribution of Photovoltaic Energy Including Topography Effect (지형 효과를 고려한 지표면 태양광 분포)

  • Jee, Joon-Bum;Zo, Il-Sung;Lee, Kyu-Tae;Choi, Young-Jean
    • Journal of the Korean earth science society
    • /
    • v.32 no.2
    • /
    • pp.190-199
    • /
    • 2011
  • A photovoltaic energy map that included a topography effect on the Korean peninsula was developed using the Gangneung-Wonju National University (GWNU) solar radiation model. The satellites data (MODIS, OMI and MTSAT-1R) and output data from the Regional Data Assimilation Prediction System (RDAPS) model by the Korea Meteorological Administration (KMA) were used as input data for the GWNU model. Photovoltaic energy distributions were calculated by applying high resolution Digital Elevation Model (DEM) to the topography effect. The distributions of monthly accumulated solar energy indicated that differences caused by the topography effect are more important in winter than in summer because of the dependency on the solar altitude angle. The topography effect on photovoltaic energy is two times larger with 1 km resolution than with 4 km resolution. Therefore, an accurate calculation of the solar energy on the surface requires high-resolution topological data as well as high quality input data.

Estimation Technique of Direction of Arrival for Location Service in the next Generation Mobile Communication System (차세대 이동통신시스템에서 Location Service를 위한 신호도착방향 추정기법)

  • 이성로;최명수;김철희;안동순;김종화
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.5A
    • /
    • pp.284-293
    • /
    • 2003
  • Location service is usually provided by the GPS method using satellites. In the next generation mobile communication systems which use smart antennas, location service can be accomplished using direction of arrival (DOA) estimation techniques. In this paper, we propose a DOA estimation technique for the location service of the next generation mobile communication systems and investigate the validity of the proposed technique through computer simulation. First, DOA estimation problems of distributed sources are considered using vortical and horizontal array processors which are orthogonal to each other. The DOA of the elevation angle is estimated by the vertical array processor and then that of the azimuth angle is estimated by the horizontal array processor. Finally, the procedures of the location service for specific signal sources using three smart antennas are exhibited by computer simulation to show that the proposed DOA estimation technique can be used for the location service in the next generation mobile communication systems.

The antenna azimuth correction method for a special purpose mobile video terminal tracking antenna system implementation (특수목적을 위한 이동형 영상 터미널 장비의 추적안테나 시스템에 적용하기 위한 방위각보정 알고리즘 구현)

  • Kim, Nam-Woo;Hur, Chang-Wu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.11
    • /
    • pp.2541-2546
    • /
    • 2013
  • In this paper, we proposed on the azimuth correction method for a line-of-sight data-link tracking antenna system. Tracking antenna system is essential to maintain line-of-sight between moving object and data-link equipment. In order to calculate the azimuth and elevation between the moving object and antenna system, we used GPS data. also to match the each coordinate systems, we used geomagnetic sensor or beacon. However, the geomagnetic disturbance-prone terrain in places difficult to correct calibration. The first step, finds the location of the strongest RF signal, we should remember the difference between the reference point and the detected position of the antenna. The second step, we could communicate each other. And the azimuth angle is calculated by GPS values. Despite the geomagnetic interference, we can correct the azimuth angle quickly and easily.

A Study of the Effect of Asperity Change on the Shear Strength of Joint Plane (절리면의 거칠기 변화가 전단강도에 미치는 영향)

  • Cho, Taechin;Suk, Jaewook;Lee, Jonggun
    • Tunnel and Underground Space
    • /
    • v.23 no.5
    • /
    • pp.401-412
    • /
    • 2013
  • Multi-stage shear test has been performed using joint specimens of gneiss, granite and shale to investigate the influence of micro-scale asperity change on the shear strength of joint plane. For each shear test asperity degradation characteristics of joint specimens of different joint surface strength have been analyzed by utilizing the optimum asperity parameter which can reflect the sequential asperity degradation. Elevation of joint surface profile has been measured and both the changes of asperity parameters and micro-scale asperity distribution have been investigated. Two distinctive variation modes of cohesion and friction angle have been delineated and major cause of shear strength parameter change has been analyzed by considering the micro-scale asperity angle change resulting from the abrasion, fracturing and regeneration of micro-scale asperities. Effects of micro-scale asperity variation on the joint shear strength have been also investigated.

The Biomechanical Analysis of Ballet Arabesque by Using Elastic Band (탄성밴드 사용유무에 따른 발레 아라베스크 동작의 운동 역학적 분석)

  • Kim, Min-Jung;Yi, Kyung-Ock
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.265-274
    • /
    • 2015
  • Objective : The purpose of this study was to analyze the effect of the elastic band on ballet arabesque based on kinematics analysis. Methods : To observe the effect of the elastic band, the availability of the elastic band during movement was set as the independent variable, and the dependent variables were set by using factors from two different categories such as motor mechanics and kinematics variables. For motor mechanics variable, the muscle activity and the center of pressure(COP)'s trajectory and velocity were used. Furthermore, the physical angle was used for kinematic variables. Data samples from the experiment was used to understand the correlation between independent and dependent variables while using paired samples t-test as a data analysis tool. Results : After analyzing the result of experiment, the usage of the Elastic band on ballet arabesque movement seemed to increase the activity of the agonistic muscle, which is mainly used for movement, and to improve the stability of the supporting leg by decreasing the trajectory and velocity of the center of pressure(COP). Moreover, the elastic band increased the level of elevation of the stretching leg with reducing the angle of the hip joint that resulted into a more stable movement and furthermore providing more beauty while standing on it. Conclusion : The movement training program while the using elastic band are expected to lead to appropriate muscular development and reduce the muscle imbalance, which usually occurs to dancers, during training with unfamiliar specific movements or strengthening muscular strength for a specific movement. In addition, this work is expected to be used as a training reference to understand and learn the fundamentals of movements of ballet and other dance fields.

An Influence Stretching Exercise with Ultrasound and Microwave Application Having on Knee Joint Position Sense after Induction to Muscle Fatigue (근피로 유발 후 신장운동시 심부투열치료가 슬관절 위치감각에 미치는 영향)

  • Park, Jang-Sung;Choi, Eun-Young;Jung, Hwa-Su
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.8 no.1
    • /
    • pp.37-42
    • /
    • 2010
  • Purpose : This study will recognize about the influences that stretching exercise with ultrasound and microwave application has on a knee joint position sense after induction to muscle fatigue. Methods : The object by each ten people divided at random thirty physical healthy adult men to constant group 1, group 2, group 3 to the objects. Treadmill exercised for induction to muscle fatigue, and let an exercise intensity decided on 85% of the maximum heart beat number with the goal heart beat number, and you exercise. Goal heart beat number measured as used heat rate monitor, and measured a oneself at the scale in order to recognize own physical state after end treadmill exercise to all objects to criteria to evaluate an ability shown in case of sports. Knee joint position sense used a N-K table, and experimenter did so as adaptation got passively arbitrary three angle done, and to order an original position. The object carried in person out one angle that experimenter designated, and measured repeatedly an error along him to this three times after being so. Rear before induction to muscle fatigue a position sense and measured after stretching exercise application, and played. Stretching exercise after induction applied stretching exercise, stretching exercise with ultrasound, stretching exercise with microwave, and applied to each group 1, group 2 and group 3 to muscle fatigue. Results : The result each group the difference which considers does not come out it was not but, improvement of the position sense is the possibility of knowing was from group 1, group 2 and group 3. Conclusion : These findings stretching exercise and stretching exercise with ultrasound and microwave after induct ion give help to a position sense elevation, and execute stretching exercise, and be effective against damage prevention by physical insecurity to muscle fatigue, and look.