• 제목/요약/키워드: Electrostatic precipitation

검색결과 40건 처리시간 0.024초

Characterization and pervaporation of chitosan/ polyacrylic acid polyelectrolyte complex membranes

  • Nam, Sang-Yong;Lee, Young-Moo
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1996년도 춘계 총회 및 학술발표회
    • /
    • pp.60-61
    • /
    • 1996
  • Polyanion-polycation complexes had been known for a long time on an empirical basis fromthe mutual precipitation of proteins, before Kossel at the end of the previous century recognized the electrostatic nature of the interaction between oppositely charged polyions. The formation of polyelectmlyte complexes is essentially a result of the electrostatic nature of the interaction between oppositely charged polyions. This interaction in the macroscopic homogeneous system the phase transition by polysalt precipitation as well as the chemical and physical structure of polyelectrolyte complex membranes have been intensively investigated from the themodynamical and kinetical point of view.

  • PDF

활성탄 섬유 필터를 전극으로 활용한 정전 방식의 공기정화장치의 가스 및 입자 제거 특성 분석 (Gas and particle removal characteristics of a novel electrostatic precipitation type air cleaner using an activated carbon filter as an electrode)

  • 임기택;김용진;한방우;우창규;신원규;김학준
    • 한국입자에어로졸학회지
    • /
    • 제14권1호
    • /
    • pp.9-16
    • /
    • 2018
  • We have developed an electrostatic precipitation (ESP) type air cleaner for indoor air quality and investigated its performances regarding CADR (Clean air delivery rate), single-pass efficiency and gas removal efficiency. The ESP air cleaner used an ACF (Activated carbon fiber) filter for gas removal and the ACF as a high voltage electrode for particle removal. The ESP air cleaner was tested in a chamber with the volume of $1m^3$ regarding CADR and gas removal efficiency. The applied CADR area of the ESP was $1.8m^2$. Gas removal efficiency was tested with 3 gases (Acetaldehyde, Acetic acid, Ammonia). As the results of the gas removal efficiency, the ESP air cleaner shows the removal efficiencies of 90, 98 and 85% for acetaldehyde, acetic acid and ammonia, respectively.

전기집진기형 공기청정기의 미세 먼지 저감 특성에 관한 연구 (Characteristics of the Reduction of Fine Particles in an Indoor Air Cleaner Using Electrostatic Precipitation Technique)

  • 목영선;이호원
    • 한국산업융합학회 논문집
    • /
    • 제7권1호
    • /
    • pp.115-120
    • /
    • 2004
  • An indoor air cleaner consisting of a dielectric barrier discharge system and an electrostatic precipitator (ESP) was experimentally investigated. The function of the dielectric barrier discharge is to precharge particles by producing nonthermal plasma before indoor air enters ESP, leading to an enhancement in dust collection efficiency. The dependence of particle size distribution on the plasma discharge was examined to understand the mechanism of the particle precharging. The plasma discharge was found to increase the electrical force of the particles, rather than agglomerate them. Coarse particles in the range of 0.5 to $5.0{\mu}m$ were observed to be easily collected by this indoor air cleaner, and the present study laid emphasis on the removal of fine particles of $0.3{\mu}m$. The collection efficiency of the fine particles was largely enhanced by the plasma discharge.

  • PDF

공조용 박형 전기집진장치 개발에 관한 연구 (A Study on the Development of Thin ESP for High Efficient Air-conditioner)

  • 홍영기;신수연;조정수;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권1호
    • /
    • pp.34-38
    • /
    • 1999
  • In order to develop a thin type ESP(Electrostatic Precipitator) for high efficient air-conditioner with low concentration of ozone generation, collecting electrode spacing should be narrower than that from Deutsch formula and minimizes discharge current in ionizer. In this paper, the effect of applied voltage on the precipitation efficiency and ozone concentration of scroll type ESP was studied. As a result, precipitation efficiency(one pass) was improved by about 30[%] from increment of collector voltage(3.5[㎸]). Precipitation efficiency was increased with increasing ionizer voltage. And after some point, the efficiency was saturated. At the point, voltage and ionizer current was 5.2[㎸] and 95$[\muA]$ per meter respectively. At these applied voltage conditions, ozone concentration was saturated about 0.01[ppm] after 3 hours in 23$[m^3]$ closed room test.

  • PDF

Effect of Co-initiator on the Size Distribution of the Stable Poly(Styrene-co-Divinylbenzene) Microspheres in Acetone/Water Mixture

  • Choi, Jin-Young;Lee, Kang-Seok;Lee, Byung-Hyung;Choe, Soon-Ja
    • Macromolecular Research
    • /
    • 제17권7호
    • /
    • pp.483-490
    • /
    • 2009
  • Stable poly(styrene-co-divinylbenzene) [P(St-co-DVB)] micro spheres with narrow size distribution were synthesized in the presence of 2,2'-azobis(2,4-dimethyl valeronitrile) (V-65) and co-initiator in an acetone/water mixture in the precipitation polymerization at $53^{\circ}C$ for 24 h. Potassium peroxodisulfate (KPS), ammonium peroxodisulfate (APS) and sodium peroxodisulfate (NaPS) were used as co-initiators. The optimum ratio of acetone to water for the formation of a narrow distribution of P(St-co-DVB) particles was 49:11 (g/g). The optimum co-initiator compositions for narrow distribution were 9:1 (g/g) for V-65 to KPS, 11:1 for V-65 to APS and 6:1 for V-65 to NaPS. The yield for these compositions was $54{\sim}57%$ and the largest particle size was obtained with the lowest zeta-potential and CV values. From the XPS measurements, the charge density was increased but the zeta potential decreased with increasing sulfur content, implying that the sulfate group provides the electrostatic stabilization on the particle surface. This suggested that the self-crosslinking between styrene and DVB, the electrostatic stabilization of initiators, and the balanced hydrophobic and hydrophilic properties of the solvents are responsible for the formation of stable P(St-co-DVB) spherical particles with narrow size distribution.

배가스 내 PM1.0 미세먼지 제거를 위한 정전분무 습식 전기집진기에 대한 연구 (Study on Wet Electric Precipitation with Electrospray for Removal of PM1.0 in Exhaust Gas)

  • 조연주;임현정;김소연;최상미;정민규;김민성
    • 플랜트 저널
    • /
    • 제16권1호
    • /
    • pp.34-37
    • /
    • 2020
  • 최근 한국의 미세 먼지 오염도가 급격히 증가함에 따라 배가스 내 미세먼지를 더욱 효과적으로 집진할 수 있는 기술에 대한 관심 또한 증가하였다. 본 연구에서는 습식 전기집진기와 사이클론 집진기에 정전분무 기술을 결합하여 집진 성능의 증대를 목표로 한다. 정전분무는 일반적으로 질량분석, 혹은 반도체 코팅에 이용되므로 그 유량이 매우 적다. 분무 액적과 미세먼지의 이온결합을 통하여 집진을 해야하는 본 연구의 특성상 기존 정전분무의 유량에 대비하여 매우 큰 유량을 사용하게 된다. 따라서 기존의 정전분무 시작 전압, 혹은 분무 형상과는 다른 형상을 보일 수 있다. 본 연구에서는 기존 정전분무와는 다른 유량 및 전압 범위를 사용함으로써 예상되는 다양한 형상 특성을 살펴보고자 한다.

반도체 제조공정 미세먼지-질소산화물 동시 저감을 위한 오존 고속산화공정 최적화 연구 (Optimization of an Ozone-based Advanced Oxidation Process for the Simultaneous Removal of Particulate Matters and Nitrogen Oxides in a Semiconductor Fabrication Process)

  • 엄성현;이승준;고은하;홍기훈;황상연
    • 공업화학
    • /
    • 제32권6호
    • /
    • pp.659-663
    • /
    • 2021
  • 반도체 제조공정에서 발생하는 미세먼지와 질소산화물 동시처리를 위하여 오존산화, 습식중화 및 습식전기집진 기술들을 직접화한 10 CMM급 복합오염물질 제거시스템을 개발하였으며, NOx 제거효율 증대를 위한 공정변수 제어 및 최적화를 진행하였다. 특히, 전원공급장치를 포함한 습식전기집진장치 핵심부품 안정성 평가를 위해 30일 동안의 장기운전도 병행하였다. 오존산화 기반 DeNOx 공정에서 가장 중요한 운전변수인 O3/NO 비율은 1.5 부근에서 최적화하였으며, 습식중화 공정의 운전변수를 최적화하여 중화반응에 의한 제거효율 기여도를 확인하였다.

기류형성을 위한 고전압 이온풍 발생장치와 코로나 제어기술에 관한 기초적 연구 (Investigation of the HV Ionic Wind Generator and the Control of Corona Discharge for Air-flow Formation)

  • 이복희;엄주홍;강성만;장근철;안창환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1707-1709
    • /
    • 2002
  • Ionic wind may be produced by DC corona discharges. In this work, the electrical effect has studied to evaluate applicability in fields of electrostatic cooling, ozone generation, electrostatic precipitation, heat transfer, air flow modification, and etc. The ionic wind velocity was measured as a function of the distance of pin to plate and the diameter of punched hole. The pin to punched-plate electrode generates airflow from pin to plate and the flow direction is controlled by the hole size of punched-plate, input voltage and distance between two electrodes. As a consequence, the ionic wind velocity is nearly proportional to the applied voltages and ranges from 1 to 3 m/sec.

  • PDF

터널팬 샤프트 환기 방식에 따른 열 및 연기배출효과에 관한 연구 (A study of Heat & Smoke Extraction Effects by the Various Operation of funnel Fan Shaft Ventilation)

  • Rie, Dong-Ho;Yoo, Ji-Oh
    • 한국화재소방학회논문지
    • /
    • 제18권2호
    • /
    • pp.49-56
    • /
    • 2004
  • 지하철은 다른 구조물과 비교하여 화재발생 시 화재진압 및 인명구조에 본질적으로 취약한 구조적 특성을 내포하고 있다. 국내의 경우, 지하철 승강장 제연설비는 전용설비로 구축되어 있지 않고 화재발생 시 승강장환기설비 및 본선터널부의 환기설비를 제연모드로 절환하여 운영되고 있다. 제연효과는 이러한 까닭으로 환기설비의 위치, 용량 및 급배기방식에 종속된다. 본 연구에서는 지하철 승강장에서 열차 화재 발생 시, 승객의 안전한 대피로 확보가 가능한 선로부 환기기의 제연운전 효과의 실효성에 대한 검증을 목표로 한다. 따라서 지하승강장을 대상으로 승강장 내 기류해석 및 3차원 화재시뮬레이션을 수행하여 열차화재에 따른 승강장내 열 및 물질이동특성해석으로부터 선로부 배연운전모드에 따른 특성을 규명함으로서 승객안전성 확보에 목표를 둔다.

반도체 배기 공정에서 복합 처리 방식으로 인한 폭발 사고 예방대책에 관한 연구 (A Study on Prevention of Explosion Accidents by Complex Treatment Methods in Semiconductor Exhaust Process)

  • 최세욱;이대준;김상령;김상길;정정희;양원백
    • 한국가스학회지
    • /
    • 제26권5호
    • /
    • pp.28-34
    • /
    • 2022
  • 반도체 공장은 인구가 밀집된 지역에 위치하여 제조 공정에서 취급되는 위험물질의 안전한 처리가 무엇보다 중요하다. 특히나 반도체 제조 공정에서 취급 후 배출되는 위험물의 종류는 매우 다양하며 물질별로 연소, 흡수, 흡착 방식 등 처리 방법도 매우 복잡하다. 따라서 최근 반도체 배기 처리 공정에서는 하나의 처리 설비에 두 개 이상의 처리 방식을 적용하고 있는데, 이러한 복합 처리방식 적용으로 예상치 못한 사고가 발생하고 있다. 본 연구에서는 최근의 사고 사례인 Scrubber 방식과 전기 집진방식을 함께 적용한 처리 설비의 사고 원인을 파악하고 예방대책을 제시하여 복합 처리방식 적용 시 유의해야 할 점을 알아보고자 한다.