• Title/Summary/Keyword: Electrospray ionization tandem mass spectrometry

Search Result 123, Processing Time 0.021 seconds

Simultaneous determination of carbaryl & organophosphorous pesticides in water by liquid chromatography-tandem mass spectrometry (LC/MS/MS를 이용한 수중의 카바릴·유기인계 농약 동시분석)

  • Park, Keun-Young;Shin, Jung-Chul;Pyo, Dongjin
    • Analytical Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • Carbaryl and seven organophosphorous pesticides were analyzed simultaneously using on-line solid phase extraction (on-line SPE) coupled with liquid chromatography tandem mass spectrometry (LC/MS/MS). The target pesticides are Carbaryl, Methyl demeton, Fenitrothion, Malathion, Parathion, Phenthoate, Diazinon, and EPN. This method includes the direct injection of $500{\mu}L$ in the water sample, a 15 min separation period using a rapid resolution liquid chromatography system with on-line SPE, and detection through electrospray ionization (ESI) positive mode. The percentage of recovery of all pesticides ranged from 85.3 % to 100 %. This method showed an accuracy of ${\geq}90.0%$, possessing limits of detection and quantification within 0.05 to $0.28{\mu}g/L$ and 0.16 to $0.89{\mu}g/L$, respectively. The correlation coefficients (r) for the calibration curves within a range of 0.5 to $8.0{\mu}g/L$ were higher than 0.99. The evaluation results showed the efficacy of the method for all contents, and no pesticides were detected in the water quality sample.

Development and validation of a selective and sensitive LC-MS/MS method for determination of misoprostol acid in human plasma: Application to bioequivalence study

  • Park, Yong Sun;Kim, Keun Nam;Kim, Ye Na;Kim, Jung Hwan;Kim, Jin Young;Sim, Soo Ji;Lee, Heon Soo
    • Analytical Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.17-25
    • /
    • 2015
  • A rapid, sensitive and specific method was developed and validated using electrospray ionization (ESI) tandem mass spectrometry (LC-MS/MS) for determination of misoprostol acid in human plasma. Misoprostol $acid-d_5$ was used as in internal standard (IS). The analyte and IS were extracted by simple one step solid phase extraction (SPE). Linearity in plasma was obtained over the concentration range 10~3000 pg/mL and lower limit of quantification (LLOQ) was identifiable and reproducible at 10 pg/mL. The intra- and inter-day precision values were below 9% and the accuracy was ranged from 93.81% to 102.02% at all four quality control samples. The method was has been successfully applied for routine assay to support pharmacokinetic study of misoprostol acid in human plasma after an oral administration of 0.4 mg misoprostol.

Rapid Screening of Phospholipid Biomarker Candidates from Prostate Cancer Urine Samples by Multiple Reaction Monitoring of UPLC-ESI-MS/MS and Statistical Approaches

  • Lim, Sangsoo;Bang, Dae Young;Rha, Koon Ho;Moon, Myeong Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.1133-1138
    • /
    • 2014
  • Ultrahigh performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI- MS/MS) provides a high-speed method to screen a large number of samples for small molecules with specific properties. In this study, UPLC-ESI-MS/MS with multiple reaction monitoring (MRM) was employed to screen urinary phospholipid (PL) content for biomarkers of prostate cancer. From lists of urinary PLs structurally identified using nanoflow LC-ESI-MS/MS, 52 PL species were selected for quantitative analysis in urine samples between 22 cancer-free urologic patients as controls and 45 prostate cancer patients. Statistical treatment of data by receiver operating characteristic (ROC) analysis yielded 14 PL species that differed significantly in relative concentrations (area under curve (AUC) > 0.8) between the two groups. Among PLs present at higher levels in prostate cancer urine, phosphatidylcholines (PCs) and phosphatidylinositols (PIs) constituted the major head group PLs (3 PCs and 7 PIs). For technical reasons, PL species of low abundance may be underrepresented in data from UPLC-ESI-MS/MS performed in MRM mode. However, the proposed method enables the rapid screening of large numbers of plasma or urine samples in the search for biomarkers of human disease.

The Physiological Role of CPR1 in Saccharomyces cerevisiae KNU5377 against Menadione Stress by Proteomics

  • Kim, Il-Sup;Yun, Hae-Sun;Kwak, Sun-Hye;Jin, Ing-Nyol
    • Journal of Microbiology
    • /
    • v.45 no.4
    • /
    • pp.326-332
    • /
    • 2007
  • In order to understand the functional role of CPRl in Saccharomyces cerevisiae KNU5377 with regard to its multi-tolerance characteristics against high temperatures, inorganic acids, and oxidative stress conditions, whole cellular proteins were analyzed via liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). This procedure was followed by two-dimensional (2-D) gel electrophoresis. Under menadione stress conditions, the 23 upregulated proteins were clearly identified only in the wild- type strain of KNU5377. Among the proteins, Sodl1p Tsa1p, Ahp1, Cpr1p, Cpr3, Ssb2p, and Hsp12p were identified as components of antioxidant systems or protein-folding related systems. The CPR1 protein could not be completely detected in the $cpr1{\Delta}$ mutant of KNU5377 and the other upregulated proteins in the wild-type strain evidenced a clear correlation with the results of immunoblot analysis. Moreover, a reduction in growth patterns (about 50%) could be observed in the $cpr1{\Delta}$ mutant, as compared with that of the wild-type strain under mild MD stress conditions. These results indicate that the upregulation of CPR1 may contribute to tolerance against MD as an inducer of oxidative stress.

Development and Validation of the Determination of Sorafenib in Human Plasma using Tandem Mass Spectrometry Coupled with Liquid Chromatography (고속액체크로마토그래피 텐덤질량분석기법을 이용한 사람 혈장 내 소라페닙 농도분석법의 개발 및 검정)

  • Park, Daejin;Lee, Sunggon;Kim, Woomi
    • Journal of Life Science
    • /
    • v.22 no.11
    • /
    • pp.1456-1462
    • /
    • 2012
  • Sorafenib is a multikinase inhibitor and an oral anticancer drug approved for the treatment of patients with advanced renal cell carcinoma and those with unresectable hepatocellular carcinoma. The purpose of this study was to develop an efficient method of the determination of sorafenib in human plasma using tandem mass spectrometry coupled with liquid chromatography (LC/MS/MS) and validate the method by the guidelines of the Korean Food and Drug Administration (KFDA). Plasma samples ($100{\mu}l$) were added with chlorantraniliprole as an internal standard and then mixed with the 0.1% formic acid-containing extraction solution composed of isopropyl alcohol and ethyl acetate (1:4, v/v). After centrifugation, the supernatant was concentrated at $45^{\circ}C$ under negative pressure and centrifugal force. The residue was reconstituted with a mobile phase and injected into the HPLC instrument using a reverse phase Waters XTerra$^{TM}$ C18 column (particle size $3.5{\mu}m$). Liquid chromatography was carried out within the run time of 5 min using a mobile phase composed of buffer (0.1% formic acid and 10 mM ammonium formate), methanol, and acetonitrile (1:6:3, v/v/v). The analytes were monitored by tandem mass spectrometry in the multiple reaction monitoring method programmed to detect sorafenib at 'm/z 465.2 ${\rightarrow}$ 252.5' and chlorantraniliprole at 'm/z 484.4 ${\rightarrow}$ 286.2' with positive electrospray ionization mode ($ES^+$). The result showed the proper linearity ($r^2$ > 0.99) over the range of 2,000-5,000 ng/ml with good accuracy (90.7-103.9%) and precision (less than 10%). The newly developed method using LC/MS/MS was validated by the guideline of KFDA and identified as more sensitive compared to the previous methods.

Purification and Identification of Antioxidant Peptides from Enzymatic Hydrolysate of Spirulina platensis

  • Yu, Jie;Hu, Yuanliang;Xue, Mingxiong;Dun, Yaohao;Li, Shenao;Peng, Nan;Liang, Yunxiang;Zhao, Shumao
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.7
    • /
    • pp.1216-1223
    • /
    • 2016
  • The aim of this study was to isolate antioxidant peptides from an enzymatic hydrolysate of Spirulina platensis. A novel antioxidant peptide was obtained by ultrafiltration, gel filtration chromatography, and reverse-phase high-performance liquid chromatography, with the 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging assay used to measure the antioxidant activity, and the sequence was determined to be Pro-Asn-Asn (343.15 Da) by electrospray ionization tandem mass spectrometry. This peptide was synthesized to confirm its antioxidant properties, and it exhibited 81.44 ± 0.43% DPPH scavenging activity at 100 μg/ml, which was similar to that of glutathione (82.63 ± 0.56%). Furthermore, the superoxide anion and hydroxyl free-radical scavenging activities and the SOD activity of the peptide were 47.84 ± 0.49%, 54.01 ± 0.82%, and 12.55 ± 0.75%, respectively, at 10 mg/ml. These results indicate that S. platensis is a good source of antioxidant peptides, and that its hydrolysate may have important applications in the pharmaceutical and food industries.

Development and validation of LC-MS/MS for bioanalysis of hydroxychloroquine in human whole blood

  • Park, Jung Youl;Song, Hyun Ho;Kwon, Young Ee;Kim, Seo Jin;Jang, Sukil;Joo, Seong Soo
    • Journal of Biomedical and Translational Research
    • /
    • v.19 no.4
    • /
    • pp.130-139
    • /
    • 2018
  • This study aimed to analyze a high-performance liquid chromatography (HPLC) separation using a pentafluorophenyl column of parent drug hydroxychloroquine (HCQ) and its active metabolite, desethylhydroxchloroquine (DHCQ) applying to determine bioequivalence of two different formulations administered to patients. A rapid, simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for bioanalysis of HCQ and its metabolite DHCQ in human whole blood using deuterium derivative $hydroxychloroquine-D_4$ as an internal standard (IS). A triple-quadrupole mass spectrometer was operated using electrospray ionization in multiple reaction monitoring (MRM) mode. Sample preparation involves a two-step precipitation of protein techniques. The removed protein blood samples were chromatographed on a pentafluorophenyl (PFP) column ($50mm{\times}4.6mm$, $2.6{\mu}m$) with a mobile phase (ammonium formate solution containing dilute formic acid) in an isocratic mode at a flow rate of 0.45 mL/min. The standard curves were found to be linear in the range of 2 - 500 ng/mL for HCQ; 2 - 2,000 ng/mL for DHCQ in spite of lacking a highly sensitive MS spectrometry system. Results of intra- and inter-day precision and accuracy were within acceptable limits. A run time of 2.2 min for HCQ and 2.03 min for DHCQ in blood sample facilitated the analysis of more than 300 human whole blood samples per day. Taken together, we concluded that the assay developed herein represents a highly qualified technology for the quantification of HCQ in human whole blood for a parallel design bioequivalence study in a healthy male.

Biological Monitoring of Workers Exposed to Diisocyanates using Urinary Diamines (소변 중 디아민을 이용한 디이소시아네이트 노출 근로자의 생물학적 모니터링)

  • Lee, Jong Seong;Kim, Boowook;Shin, Jungah;Baek, JinEe;Shin, Jae Hoon;Kim, Ji-hye
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.2
    • /
    • pp.178-187
    • /
    • 2016
  • Objectives: Diisocyanates are a potent inducer of diseases of the airways, especially asthma. In this study, toluenediamine(TDA) and methylenedianiline(MDA) in urine were evaluated as biomarkers of exposure to tolunenediisocyanate(TDI) and methylenediphenyl diisocyanate(MDI), respectively. Methods: Workers exposed to TDI and MDI, as well as non-occupationally exposed subjects, were studied and pre- and post-shift urine samples were collected from 8 control subjects and 8 workers from a factory which manufactures polyurethane products for reducing noise and vibration in automobiles. Airborne TDI and MDI(n=8) were sampled on solvent-free glass filters impregnated with n-butylamine and detected by liquid chromatography atmospheric pressure ionization tandem mass spectrometry. Urinary TDA and MDA were detected as pentafluoropropionic acid anhydride(PFPA) derivatives by liquid chromatography electrospray ionization tandem mass spectrometry. Results: The median levels of urinary 2,6-TDA(p<0.001), 2,4-TDA(p=0.001), and MDA(p<0.001) of workers in post-shift samples were significantly higher than those of controls. The median levels of urinary 2,6-0TDA($0.63{\mu}g/g$ creatinine vs $0.34{\mu}g/g$ creatinine, p=0.017) and MDA($4.21{\mu}g/g$ creatinine vs $3.18{\mu}g/g$ creatinine, p=0.017) of workers in post-shift samples were significantly higher than those of the pre-shift samples. There were significant correlations between the urinary 2,6-TDA, 2,4-TDA, and MDA of workers in post-shift samples and the airborne 2,6-TDI(rho=0.952, p<0.001), 2,4-TDI(rho=0.833, p=0.001), and MDI(rho=0.952, p<0.001). Conclusions: These urinary diamines, metabolites of diisocyanates, in post-shift samples were useful biomarkers to assess occupational exposure to diisocyanates.

Electrospray ionization tandem mass fragmentation pattern of camostat and its degradation product, 4-(4-guanidinobenzoyloxy)phenylacetic acid (Camostat 및 분해산물 4-(4-guanidinobenzoyloxy)phenylacetic acid의 전자분무 이온화 텐덤 질량 fragmentation 패턴)

  • Kwon, Soon-Ho;Shin, Hye-Jin;Park, Ji-Myeong;Lee, Kyoung-Ryul;Kim, Young-Jin;Lee, Sang-Hoo
    • Analytical Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.78-84
    • /
    • 2011
  • The fragmentation patterns of a serine protease inhibitor, camostat, and its degradation product, 4-(4-guanidinobenzoyloxy)phenylacetic acid (GBPA), were for the first time investigated by a triple quadrupole tandem mass spectrometry equipped with an electrospray source (ESI-MS/MS) in positive and/or negative ion mode under collision-induced dissociation (CID). The positive CID spectrum of camostat showed distinctly that the single bond (C-O) cleavage between carbonyl group and oxygen atom of the ester bonds of the compound favorably occurred and then the loss of N,N-dimethylcarbamoylmethyl group was more susceptible than that of guanidine moiety. In the positive ion CID spectrum of GBPA, the initial cleavage between the carbonyl group and oxygen atom of 4-guanidinobenzoyloxy group also occurred, yielding the most abundant fragment ion at m/z 145. On the other hand, the negative CID spectrum of GBPA characteristically showed the occurrence of the most abundant peak at m/z 226 resulting from the sequential neutral losses of $CO_2$ and HN=C=NH from the parent ion at m/z 312.

Monitoring of Veterinary Antibiotics in Agricultural Soils using Liquid Chromatography Coupled with Tandem Mass Spectrometry (LC-MS/MS를 이용한 농경지 토양 중 항생제 모니터링)

  • Lee, Young-Jun;Choi, Jeong-Heui;Chung, Hyung Suk;Lee, Han Sol;Park, Byung-Jun;Kim, Jang-Eok;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.3
    • /
    • pp.166-174
    • /
    • 2016
  • BACKGROUND: The current study developed a monitoring method of 6 veterinary antibiotics (amoxicillin, ampicillin, enrofloxacin, tetracycline, chlortetracycline, oxytetracycline) in agricultural soils using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in positive electrospray ionization mode.METHODS AND RESULTS: Sample preparation was carried out using acidic acetonitrile and citrate salts followed by purification with dispersive solid phase extraction (d-SPE). Separation on Eclipse Plus C18 column was conducted in gradient of the mobile phase, 0.1% formic acid and 5 mM ammonium formate in methanol (A) and 0.1% formic acid and 5 mM ammonium formate in distilled water (B). The linearity of the matrix-matched calibrations expressed as the coefficient of determination was good with R2≥0.9900. The limit of quantifications (LOQs) ranged from 0.5 to 10 μg/kg for all analytes. Analysis of 51 agricultural soil samples taken in the Republic of Korea revealed concentrations less than 1.9 μg/kg for enrofloxacin, 75.5 μg/kg for chlortetracycline.CONCLUSION: The method was successfully applied to monitor 6 veterinary antibiotics from 51 field incurred agricultural soil samples in 17 provincial areas throughout the Republic of Korea. The developed method was simple, easy, and versatile and can be used for monitoring various veterinary antibiotics in soil.