• Title/Summary/Keyword: Electroplating method

Search Result 143, Processing Time 0.021 seconds

Field Validation of an IC/Visible Spectrophotometry Method for the Determination of Cr(VI) in Mist (미스트중 6가 크롬 측정을 위한 IC/Visible Spectrophotometry 방법 (Shin & Paik′s Method)의 현장 평가)

  • 신용철;백남원;김상우;김선자;이유미
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.40.1-43
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of hexavalent chromium, Cr(VI) in mist from field plating operation. The Procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute for Occupational Safety and Health (NIOSH) Method 7600, and the filter sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(VI) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(VI) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(VI) on PVC filters and storing the sample filters in screw-capped vials according to the NIOSH method, and analyzing Cr(VI) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(VI) into 0.02 MN/sub a/Hco₃ solution in midget impinger, and analyzing the Cr(VI) in samples using IC/VS. The third method was the OSHA Method Id-215. Using these four different methods, four replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and Paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r/sup 2/=0.99) between Cr(VI) concentrations measured by the shin & Paik's Method and an impinger method (p>0.05). However, Cr(VI) concentrations determined by Shin & Paik's Method were Significantly different form those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(VI) concentrations of Shin & Paik's Method were Significantly higher than those of the NIOSH/EPA Method or the OSHA method. We concluded that the Shin & Paik's Method could prevent Cr(VI) losses caused by reduction and give more reliable results of airborne Cr(VI) concentrations in work environments.

  • PDF

Change of physical properties after diameter increase by electroplating of orthodontic rectangular stainless steel wire (전기도금을 이용한 스테인레스 스틸 각형 선재의 굵기 증가 후 물성 변화)

  • Lee, Jeong-Seok;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.131-140
    • /
    • 2003
  • The purpose of this study was to evaluate clinical applications of electroplating method through investigation of the physical properties of orthodontic rectangular wires according to varying their cross section. For the study, it was accomplished to electroplate the 0.016-inched orthodontic rectangular stainless steel wire. The cross section of stainless steel orthodontic rectangular wire increased from $0.016{\times}0.016inch\;to\;0.017{times}0.017inch$ by electroplating. The wire was heat treated to improve an adhesion between the wire and electroplated metal. h three-point bending test and torsion test were conducted in order to compare physical properties among three wire groups; $0.016{\times}0.016wires(group 016),\; electroplated\;0.016{\times}0.016wires(group\;016P)\;and\;0.017{\times}0.017$ wires (group 017). Through the investigations of each wire group, following results were obtained 1. At three-point bending test, the group Ol6P showed higher tendency in the degree of stiffness, yield strength and ultimate tensile strength than the group 016. Stiffness and ultimate tensile strength showed statistically significant differences between two groups at three-point bending test (p<0.05). 2. Stiffness, yield strength, and ultimate tensile strength of the group 016P showed lower tendency than those of the group 017 Stiffness showed statistically significant differences between two groups at three-point bending test (p<0.05). 3. Torque/twist rate, yield torsional moment, and ultimate torsional moment of the group 016P showed higher tendency than those of the group 016. All measurements showed statistically significant differences between two groups alter torsion test (p<0.05). 4. Torque/twist rate, yield torsional moment, and ultimate torsional moment of the group 0166P showed lower tendency than those of the group 017. Yield torsional moment, and ultimate torsional moment showed statistically significant differences between two groups after torsion test (p<0.05).

Microdevice for Separation of Circulating Tumor Cells Using Embedded Magnetophoresis with V-shaped Ni-Co Nanowires and Immuno-nanomagnetic Beads

  • Park, Jeong Won;Lee, Nae-Rym;Cho, Sung Mok;Jung, Moon Youn;Ihm, Chunhwa;Lee, Dae-Sik
    • ETRI Journal
    • /
    • v.37 no.2
    • /
    • pp.233-240
    • /
    • 2015
  • The novelty of this study resides in a 6"-wafer-level microfabrication protocol for a microdevice with a fluidic control system for the separation of circulating tumor cells (CTCs) from human whole blood cells. The microdevice utilizes a lateral magnetophoresis method based on immunomagnetic nanobeads with anti-epithelial cell adhesive molecule antibodies that selectively bind to epithelial cancer cells. The device consists of a top polydimethylsiloxane substrate for microfluidic control and a bottom substrate for lateral magnetophoretic force generation with embedded v-shaped soft magnetic microwires. The microdevice can isolate about 93% of the spiked cancer cells (MCF-7, a breast cancer cell line) at a flow rate of 40/100 mL/min with respect to a whole human blood/buffer solution. For all isolation, it takes only 10 min to process 400 mL of whole human blood. The fabrication method is sufficiently simple and easy, allowing the microdevice to be a mass-producible clinical tool for cancer diagnosis, prognosis, and personalized medicine.

A Study on New Twist-Diamond Wire Characteristics for Improving Processing Performance (트위스트 다이아몬드 와이어의 성능향상을 위한 특성평가에 관한 연구)

  • Park, Chang-Yong;Kweon, Hyun-Kyu;Peng, Bo;Jung, Bong-Gyo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.1
    • /
    • pp.26-33
    • /
    • 2016
  • In this study, a new method to develop a fixed diamond wire for silicon wafer machining by the multi-wire cutting method was developed. The new twist diamond wire has improved performance with high breaking strength and chip flutes structure. According to these characteristics, the new twist diamond wire can be used in the higher speed multi-wire cutting process with a long lifetime. Except the design of the new structure, the twist diamond wire is coating by electroless-electroplating process. It is good for reducing breakage and the falling-off of diamond grains. Based on the silicon material removal mechanism and performance of the wire-cutting machine, the optimal processing condition of the new twist diamond wire has been derived via mathematical analysis. At last, through the tensile testing and the machining experiments, the performance of the twist diamond wire has been obtained to achieve the development goals and exceed the single diamond wire.

Environment-friendly Trivalent Chromate Treatment for Zn Electroplating (아연도금용 친환경 3가 크로메이트 표면처리기술)

  • Kim, Soo Won;Lee, Chul Tae
    • Applied Chemistry for Engineering
    • /
    • v.17 no.5
    • /
    • pp.433-442
    • /
    • 2006
  • Hexavalent chromium passivation, as very effective anti-corrosion method, can not be used in the field of surface treatment for metal, any more. Throughout the world, this regulations which was applied to automotive industries will be extended to all industries including electronics industries in the near future. Therefore a new anti-corrosion method should be established without delay, and trivalent chromium passivation as an alternatives replace the hexavalent chromium passivation for the time being. This paper gives an overview of the currently available trivalent chromium passivation processes, and then it attempts to give an insight to develop a more effective trivalent chromium conversion coating process for possible substitution of the hexavalent chromium passivation process.

Development of an Electromagnetic Actuator for Probe-based Data using Si Storage by Process and Cu Electroplating (실리콘 공정 및 동 도금 기술을 이용한 탐침형 정보저장장치의 전자기력 미디어 구동기 제작)

  • 조진우;이경일;김성현;최영진
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.4
    • /
    • pp.225-230
    • /
    • 2004
  • An electromagnetic actuator has been designed and fabricated for Probe-based data storage applications. The actuator consists of permanent magnets(SmCo) housing and a media Platform which is connected to the Si frame by four couples of Si leaf springs. In order to generate electromagnetic force, Cu coils were electroplated under the media platform. The magnetic field distribution was calculated with 3D Finite Element Method of Maxwell 3D program. The field strength felt by Cu coils was estimated to be about 0.33T when the distance between the media platform and permanent magnets is $200\mu\textrm{m}$. The static and dynamic motions of the actuator were analyzed by FEM method with ANSYS 5.3. The measured displacements of the actuator were about $\pm$$92\mu\textrm{m}$ for input current of $\pm$40㎃ and the resonance frequency was 100Hz. The proposed electromagnetic actuator can be utilized for media driver of probe-based data storage system.

Rapid Fabrication of Micro Lens Array by 355nm UV Laser Irradiation (355nm UV 레이저를 이용한 마이크로 렌즈 어레이 쾌속 제작)

  • Je, Soon-Kyu;Park, Kang-Su;Oh, Jae-Yong;Kim, Kwang-Ryul;Park, Sang-Hoo;Go, Cheong-Sang;Shin, Bo-Sung
    • Laser Solutions
    • /
    • v.11 no.2
    • /
    • pp.26-32
    • /
    • 2008
  • Micro lens array (MLA) is widely used in information technology (IT) industry fields, for examples such as a projection display, an optical power regulator, a micro mass spectrometer and for medical appliances. Recently, MLA have been fabricated and developed by using a reflow method, micro etching, electroplating, micromachining and laser local heating. Laser local thermal-expansion (LLTE) technology demonstrates the formation of microdots on the surface of polymer substrate, in this paper. We have also investigated the new direct fabrication method of placing the MLA on the surface of a SU-8 photoresist layer. We have obtained the 3D shape of the micro lens processed by UV laser irradiation and have experimentally verified the optimal process conditions.

  • PDF

Accuracy and Precision of Microwave Oven Digestion/Atomic Absorption Spectrophotometry for Analyzing Airborne Chromium Collected on MCE Filter in Plating Operation (도금공정 크롬시료 분석을 위한 Microwave Oven Digestion/Atomic Absorption Spectrophotometry 방법의 정확도 및 정밀도 평가)

  • Lee, Byung-Kyu;Lee, Ji-Tae;Shin, Yong-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.48-55
    • /
    • 2001
  • The purpose of this study was to evaluate the analytical accuracy and precision of microwave oven digestion/atomi absorption spectrophotometry (AAS) for analyzing airborne chromium collected on mixed cellulose ester membrane (M filter from the work environment, and to compare the accuracy and the precision with those of the National Institute for Occupational Safety and Health (NIOSH) Method #7024 hot plate digestion/AAS method. For this study, field air sample pairs were collected from a electroplating process, and spiked samples in a laboratory were prepared and using these samples. Two digestion methods were comp; and evaluated in terms of recovery rate and bias as indices of accuracy and coefficient of variation as a index of precision. The results and conclusions are as follows. In spiked samples, the accuracies (% mean recoveries) of hot plate/AAS and microwave oven/AAS method were 97.19%, 97.1%, respectively, and the precisions (pooled respectively, and the precisions (pooled coefficient of variance, $CV_{pooled}$) 6.93% and 3.88%, respectively. The biases of hot plate ani microwave oven methods were 4.56 - 14.7% and 2.22 - 7.42% respectively. There was no statistically significant difference between hot plate and microwave oven methods recovery rates of spiked samples (p>0,05). Also, no statistically significant difference was shown among the concentrations of air samples determined by two method (p>0.05). In conclusion, microwave oven/AAS method h excellent accuracy and precision, and advantages such as time-saving and simple procedure in comparison with the classical NIOSH method. Therefore, this method can be use widely to analyze airborne chromium collected on MCE filter from the work environments.

  • PDF

A Study on the standardize the characteristic evaluation of DC magnetron sputtered silver coatings for engineering purposes (D.C. magnetron sputter를 이용한 Ag layer 건식 도금층의 특성 평가 국제 표준화에 대한 연구)

  • Gyawali, Gobinda;Choi, Jinhyuk;Lim, Tae Kwan;Jung, Myoung Joon;Lee, Soo Wohn
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.249-249
    • /
    • 2015
  • Silver films have been of considerable interest for years due to their better performance relative to other metal films for engineering applications. A series of multi-layer silver coatings with different thickness (i.e. 0.3 um to 1.5 um) were prepared on Aluminium substrate containing copper undercoat by direct current (DC) magnetron sputtering method. For the comparative purpose, similar thickness silver coatings were prepared by electrolytic deposition method. Microstructural, morphological, and mechanical characteristics of the silver coatings were evaluated by means of scanning electron microscope (SEM), X-ray diffraction (XRD), Surface roughness test, microhardness test and nano-scratch test. From the results, it has been elucidated that the silver films prepared by DC magnetron sputtering method has superior properties in comparison to the wet coating method. On the other hand, DC magnetron sputtering method is relatively easier, faster, eco-friendly and more productive than the electrolytic deposition method that uses several kinds of hazardous chemicals for bath formulation. Therefore, a New Work Item Proposal (NWIP) for the test methods standardization of DC magnetron sputtered silver coatings has recently been proposed via KATS, Korea and a NP ballot is being progressed within a technical committee "ISO/TC107-metallic and other inorganic coating".

  • PDF

The Treatment of Heavy Metal-cyanide Complexes Wastewater by Zn$^{+2}$/Fe$^{+2}$ Ion and Coprecipitation in Practical Plant (II) (아연백법 및 공침공정을 이용한 복합 중금속-시안착염 폐수의 현장처리(II))

  • Lee, Jong-Cheul;Lee, Young-Man;Kang, Ik-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.5
    • /
    • pp.524-533
    • /
    • 2008
  • Industrial wastewater generated in the electroplating and metal finishing industries typically contain toxic free and complex metal cyanide with various heavy metals. Alkaline chlorination, the normal treatment method destroys only free cyanide, not complex metal cyanide. A novel treatment method has been developed which destroys both free and complex metal cyanide as compared with Practical Plant(I). Prior to the removal of complex metal cyanide by Fe/Zn coprecipitation and removal of others(Cu, Ni), Chromium is reduced from the hexavalent to the trivalent form by Sodium bisulfite(NaHSO$_3$), followed by alkaline-chlorination for the cyanide destruction. The maximum removal efficiency of chromium by reduction was found to be 99.92% under pH 2.0, ORP 250 mV for 0.5 hours. The removal efficiency of complex metal cyanide was max. 98.24%(residual CN: 4.50 mg/L) in pH 9.5, 240 rpm with 3.0 $\times$ 10$^{-4}$ mol of FeSO$_4$/ZnCl$_2$ for 0.5 hours. The removal efficiency of Cu, Ni using both hydroxide and sulfide precipitation was found to be max. 99.9% as Cu in 3.0 mol of Na$_2$S and 93.86% as Ni in 4.0 mol of Na$_2$S under pH 9.0$\sim$10.0, 240 rpm for 0.5 hours. The concentration of residual CN by alkaline-chlorination was 0.21 mg/L(removal efficiencies: 95.33%) under the following conditions; 1st Oxidation : pH 10.0, ORP 350 mV, reaction time 0.5 hours, 2nd Oxidation : pH 8.0, ORP 650 mV, reaction time 0.5 hours. It is important to note that the removal of free and complex metal cyanide from the electroplating wastewater should be employed by chromium reduction, Fe/Zn coprecipitation and, sulfide precipitation, followed by alkaline-chlorination for the Korean permissible limit of wastewater discharge, where the better results could be found as compared to the preceding paper as indicated in practical treatment(I).