• 제목/요약/키워드: Electronics cooling

검색결과 323건 처리시간 0.029초

스윙 압축기의 수치해석적 성능평가 (Numerical Performance Analysis of the Swing Compressor)

  • 문석환;노기율;사범동;양장식;최경민;김덕줄
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.77-84
    • /
    • 2012
  • Numerical performance analysis of the vane-roller integral type swing compressor was conducted. The swing compressor has been investigated for the highly efficient air conditioning system. Performance analysis results of the swing compressor were compared with those of a conventional rotary compressor. Mechanical and gas losses of a swing compressor were larger than those of a rotary compressor. However in case of mass flow rate from the discharge port, the swing compressor was about 6.68% higher than the rotary compressor. Hence the EER, the cooling capacity and the compressor work of the swing compressor were about 3.71%, 6.69% and 2.90% higher than the rotary compressor respectively.

과냉도에 따른 모세관 입구단에서의 냉매 상태 변화가 냉장고 냉매 소음에 미치는 영향의 실험적 분석 (Experimental Analysis of the Effect of Phase Change at the Entrance of a Capillary Tube by Sub-cooling Control on Refrigerant-induced Noise)

  • 오영후;김민성;한형석;김태훈;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제22권12호
    • /
    • pp.1184-1190
    • /
    • 2012
  • This study is focused on the experimental analysis of the noise induced by phase change of refrigerant at the entrance of capillary tube. The refrigerant is usually two-phase condition when it flowed into the capillary tube. At the entrance of capillary tube, the phase condition of refrigerant is formed by sub-cool control. If it has sufficient sub-cool temperature, all of the vapor refrigerants turned to liquid, which means there is only liquid. Otherwise, the gas is coexisted. Based on this theory, we experiment on each case by changing sub-cool temperature using refrigerant-supplying equipment. The noise level is measured for each case and compared.

Sr1-xBaxNb2O6의 유전 특성에 대한 산화/환원 열처리의 영향 (Oxidation/Reduction Effect on Dielectric Properties of Sr1-xBaxNb2O6)

  • 강봉훈;백영섭;주기태
    • 한국세라믹학회지
    • /
    • 제43권3호
    • /
    • pp.173-176
    • /
    • 2006
  • ${Sr_{1-x}Ba_xNb_2O_6$(SBN) have been obtained in Pt crucible by melting and cooling in air atmosphere. Some SBNs being at the bottom of the crucible are black and transparent, and the other SBNs colorless. The black SBN became to be colorless by oxidation heat treatment $1,300^{\circ}C$ for 4 h, Curie temperature is changed by colorless change of black SBN. The reason seems to be $Nb^{5+}$ oxidation of some $Nb^{4+}$ ions in SBN or effect of unknown impurities. Diffused Phase Transition (DPT) was appeared during heating and cooling process. Various sintered SBN ceramics specimen showed relaxor characteristics.

산업용 냉각기의 압축기 회전수 변화에 따른 용량제어 특성 (The characteristics of capacity control using a variable speed compressor in an industrial cooler)

  • 백승문;문춘근;윤정인;정석권;김은필
    • 동력기계공학회지
    • /
    • 제15권2호
    • /
    • pp.37-41
    • /
    • 2011
  • This paper presents the capacity-control characteristics in an industrial cooler with a variable speed compressor. The inverter-type compressor is controlled by the rotational speed of the operational frequency. This type of the compressor performs the wide range of load compared to the on-off type. When the load of the system reduces, the rotational speed will be reduced. Thus, the system leads to the less power consumption and extends the longer durability of the compressor. With the variable rotational speed of the compressor the cooling capacity of the cooler is about 1.6-3.6 kW and the capacity control is about 40-100%. The system showed the highest efficiency when the rotational speed is about 45-70 Hz. The results can be used as the basic design data to control an industrial cooler.

베인-롤러 일체형 로타리 압축기 (Rotary compressor with combined vane and roller)

  • 안종민;김현진;강승민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.904-909
    • /
    • 2009
  • In this paper, a rolling piston rotary compressor having a combined vane and roller unit has been introduced. In a conventional rotary compressor, sliding motion takes place between the vane nose and roller. By combining the vane and the roller in one unit, gas leakage through a clearance between the vane nose and the roller can be eliminated, and the frictional loss between them can also be reduced to almost nought. Compressor model with the combined vane and roller has been fabricated and tested in a compressor calorimeter and computer simulation program has been developed to confirm merits of the new mechanism. In a test, cooling capacity has been found to be increased by 1.4%, and the compressor input decreased by 0.3%, resulting in 1.7% increased in EER. Simulation program confirmed the calorimeter test results and the merits of the new model as mentioned above.

  • PDF

고온가스 및 액체 바이패스 적용 용량가변 히트펌프의 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of Hot-gas and Liquid Bypass Heat Pump Systems for Capacity Modulation)

  • 안재환;주영주;윤원재;강훈;김용찬
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.137-142
    • /
    • 2013
  • A small air-conditioner or chiller for a constant temperature bath normally uses a constant speed compressor. The constant speed compressor is relatively inexpensive, but it uses on/off control for capacity modulation. The on/off control has several disadvantages, specifically energy loss and large temperature fluctuation. Continuous operation with a bypass system can be an alternative to on/off control, for capacity modulation. In this study, a heat pump system having a hot-gas bypass and a liquid bypass was adopted. The performance of the bypass-type heat pump was measured, by varying the bypass valve opening. The differences of the COP between the hot-gas bypass and the liquid bypass, in the cooling and heating operations, were within 2% and 1%, respectively. The liquid bypass showed a wider range of capacity control in the cooling operation but the hot-gas bypass showed a wider range of capacity control in the heating operation.

저온용 대체냉매의 성능 특성 연구 (Performance Characteristics Study on an Alternative Refrigerant in Low Temperature Applications)

  • 신정섭;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제27권4호
    • /
    • pp.462-469
    • /
    • 2016
  • This paper presents the results of thermodynamic cycle analysis and performance tests of alternative mixtures in low temperature applications. Two near-azeotropic binary mixtures R-152a/R-1270 (35:65 by wt.%) and R-290/E170 (35:65 by wt.%) are considered in this study. They have zero ODP (Ozone Depletion Potential) and much lower GWP (Global Warming Potential) than R-404A which is an alternative of R-502. Refrigeration cycle characteristics such as cooling capacity, coefficient of performance, suction and discharge pressures and temperatures are compared to those for the baseline refrigerants (R-502 and R-404A) cycles. The performance tests are conducted at the evaporation and condensation temperatures of $5^{\circ}C$ and $45^{\circ}C$, subcooling and superheating temperatures of $5^{\circ}C$, respectively. Performance comparisons between baseline and alternative refrigerants are conducted on the same cooling capacity. The system performance of newly proposed refrigerant mixtures show promising results.

태양광 발전의 성능향상을 위한 PV/T 시스템 개발 (Development of PV/T for Performance Improvement of Photovoltaic System)

  • 최정식;고재섭;강성준;백정우;장미금;문주희;정동화
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.95-96
    • /
    • 2010
  • This paper proposes photovoltaic thermal hybrid module to get the electrical and Thermal performance of building integrated photovoltaic(BIPV) system. BIPV system is decreased the system efficiency because output of PV is decreased by the thermal rising on generating. In order to improve the efficiency of BIPV module, water cooling system is applied and generated thermal is used the warm water system. Water cooling system uses the flux control algorithm considering water temperature and power loss. Electrical and thermal performance of proposed photovoltaic thermal hybrid module is confirmed through the actual experiment and herby proved the valid of this paper.

  • PDF

Synthesis of Few-layer Graphene Film on a Ni Substrate by Using Filtered Vacuum Arc Source Method

  • 김창수;서지훈;강재욱;김도근;김종국;이형우
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.157-157
    • /
    • 2011
  • Graphene has generated significant interest in the recent years as a functional material for electronics, sensing, and energy applications due to its unique electrical, optical, and mechanical properties. Much of the considerable interest in graphene stems from results obtained for samples mechanically exfoliated from graphite. Practical applications, however, require reliable and well-controlled methods for fabrication of large area graphene films. Recently high quality graphene layers were fabricated using chemical vapor deposition (CVD) on nickel and copper with methane as the source of the carbon atoms. Here, we report a simple and efficient method to synthesize graphene layers using solid carbon source. Few-layer graphene films are grown using filtered vacuum arc source (FVAS) technique by evaporation of carbon atom on Ni catalytic metal and subsequent annealing of the samples at 800$^{\circ}$C. In our system, carbon atoms diffuse into the Ni metal layer at elevated temperatures followed by their segregation as graphene on the free surface during the cooling down step as the solubility of carbon in the metal decrease. For a given annealing condition and cooling rate, the number of graphene layers is easily controlled by changing the thickness of the initially evaporated amorphous carbon film. Based on the Raman analysis, the quality of graphene is comparable to other synthesis methods found in the literature, such as CVD and chemical methods.

  • PDF

R32 인버터 히트펌프 시스템의 성능향상에 관한 실험적 연구 (An Experimental Study on the Performance Improvement of an R32 Inverter Heat Pump System)

  • 박윤기;하만영
    • 설비공학논문집
    • /
    • 제26권11호
    • /
    • pp.547-552
    • /
    • 2014
  • As global warming in recent years has raised ever more critical concern, refrigerants with high global warming potentials (GWP) are facing the challenge of being phased out. R410A, with a GWP of 2,088, has been widely used in residential air-conditioning and heat pump systems. A potential substitute for R410A is R32, which has a GWP of 675. The present study presents experimental results of an inverter heat pump system that uses R32 as an alternative refrigerant to R410A. Drop-in tests with R32 indicated that the energy efficiency ratio of the system increased by 5.3% in cooling standard mode, and by 4.2% in heating standard mode at the same capacity; and that the cooling and heating capacity increased by about 12% at the same compressor operating frequency, while the annual performance factor (APF) of the system increased by 5.3%.