• Title/Summary/Keyword: Electronics Control

Search Result 11,443, Processing Time 0.045 seconds

The Design of the Greenhouse Control System (PLC에 의한 온실 제어기의 개발)

  • Lim, S.K.;Kim, K.J.;Kook, H.S.;Rhyeo, U.J.;Chin, D.B.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.228-231
    • /
    • 1995
  • The main purpose of this paper is to develop the greenhouse control system by PLC in order to dismiss the subject which sequence control system has. The result of this research will contribute to the competitive agriculture product by offering versatile and tow cost greenhouse control system.

  • PDF

Improved full wave mode ZVT-PWM DC-DC Converters (개선된 전파형 ZVT-PWM DC-DC 컨버터)

  • Kim T.W.;Kang A.J.;Chin G.H.;Kim H.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.777-780
    • /
    • 2003
  • In this paper, an improved full wave mode ZVT-PWM DC-DC Converter is presented to maximize the regeneration ratio of resonant energy by only putting an additional diode in series with auxiliary switch. The operation of auxiliary switch in a half wave mode makes possible the soft switching condition of all switches. Furthermore, the increase of the regeneration ratio to resonant energy results in low conduction losses and minimum voltage and current stresses. The operation principles of the proposed converters are analyzed using the PWM boost converter topology as an example. Theoretically analysis and experimental results verify the validity of the boost converter topology with the proposed full wave mode ZVT-PWM converters

  • PDF

ZVT boost converter with minimizing conduction losses of the main switch (주 스위치의 전도손실을 최소화한 ZVT 부스터 컨버터)

  • Chin Gi-Ho;Kang Ahn-Jong;Kim Tae-Woo;Kim Hack-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.95-98
    • /
    • 2003
  • A ZVT PWM Boost Converter is proposed to reduce current stresses and conduction losses of main switch in a conventional circuit. By attaching resonant inductor Lr1 in parallel with capacitor Cr, the resonant circulating current is diverted to the additional component and then the main switch is subjected to minimum current stresses same as those in their PWM counterparts. Moreover, the operation of the auxiliary switch in a half wave mode to prevent reverse resonant energy from freewheeling can be able to lessen the conduction losses. The operation principles of the proposed converters are analyzed using the PWM boost converter topology as an example. Theoretically analysis and experimental results verify the validity of the boost converter topology with the proposed circuit.

  • PDF

Video Rate Control Using Activity Based Rate Prediction

  • Park, Hyung-Shin;Jung, You-Young;Kim, Young-Ro;Ko, Sung-Jea
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.454-457
    • /
    • 2000
  • In this paper, an efficient rate control algorithm based on rate prediction is proposed for maintaining a smooth buffer variation and a small buffer size. The proposed method adjusts the quantization scaling factor by using the predicted bit-rate to meet the target bit budget exactly. Experimental result show that the proposed prediction-based rate control scheme can regulate the bit-rate across scene changes more effectively and achieve better PSNR performance than existing rate control mechanisms such as the MPEG-2 Test Model 5 (TM5) and the Adaptive Scene Analysis (ASA).

  • PDF

A Study of ZC-ZVS PWM Boost Converter (ZC-ZVS PWM 승압형 컨버터에 관한 연구)

  • Kim Tea-Woo;Jung Hyo-Geun;Ahn Hee-Wook;Kim Hack-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.211-214
    • /
    • 2001
  • This paper introduces a ZC-ZVS PWM(Pulse-Width -Modulation) boost converter. The IGBT(main switch) of the proposed converter is always switched at ZCS and soft switching of MOSFET(auxiliary switch) as well. Therefore, the proposed converter minimized the turn on/turn off switching losses of switches and reduced conduction losses by using IGBT switch. Moreover, using paralleled IGBT-MOSFET switch overcame the switching frequency limitation. Therefore high power density system can be realized. As mentioned above, the characteristics are verified through experimental results.

  • PDF

Hybrid Sliding-Mode Controller for the Speed Control of a Hydraulic Inverter-Fed Elevator (유압식 인버터 엘리베이터의 속도제어를 위한 하이브리드 슬라이딩모드제어기)

  • Han, Gueon-Sang;Park, Jae-Sam;Ahn, Hyun-Sik;Kim, Do-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.6
    • /
    • pp.37-47
    • /
    • 2001
  • Due to the friction characteristics of pump, cylinder packing and passenger car, in the elevator actuated with hydraulic inverter-fed systems, there exist dead zones, which cannot be controlled by a PID controller. To overcome the drawbacks, in this paper, we propose a new hybrid control scheme, which switches the modes between a sliding mode controller and a PID controller. The proposed hybrid control scheme achieves an improved control performance by using both controllers. We first propose a design method of sliding mode controller for a hydraulic elevator system controlled by inverters, then fellowed by a design method of a hybrid sliding mode control scheme is proposed. The effectiveness of the proposed control scheme are shown by simulation results, which the proposed hybrid control method yields better control performance then the PID controlled scheme, not only in the zero-crossing speed region but also in the overall control region including steady-state region.

  • PDF

Full digital control of permanent magnet AC servo motors

  • Lee, Jin-Won;Kim, Dong-Il;Jin, Sang-Hyun;Oh, In-Hwan;Kim, Sungkwun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.218-223
    • /
    • 1993
  • In this paper, we present a full digital control scheme which controls currents and speed of the permanent magnet AC servo motor with large range of bandwidth and high performance. The current equations of the permanent magnet AC servo motor are linearized by feedback linearization technique. Both acceleration feedforward terms and IP controllers, whose gains are functions of motor speed, are used in order to control motor currents. In addition the phase delays in current control loops are compensated by placing phase lead-lag compensators after current commands, which make it possible to avoid high gains in the current controllers. Unity power factor can be achieved by the proposed current controller. Pulsewidth modulation is performed by way of the well-known comparison with a triangular carrier signals. The velocity controller is designed on the basis of the linearized model of the permanent magnet AC servo motor by the proposed current controller. The performance of the entire control system is analyzed in the presence of uncertainty in the motor parameters. The proposed control scheme is implemented using the digital signal processor-based controller composed of an Analog Device ADSP 2111 and a NEC78310. The pulsewidth modulation (PWM) signals are generated through a custom IC, SAMSUNG-PWM1, which has the outputs of current controllers as input. The experimental results show that the permanent magnet AC servo motor can be always driven with high dynamic performance by the proposed full digital control scheme of motor speed and motor current.

  • PDF

Device Independent Remote Controlling Using a 8-bit Microcontroller (마이크로콘트롤러를 사용한 만능 적외선 리모컨 제어)

  • Kim, Jin Young;Moon, Sangook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.412-413
    • /
    • 2016
  • Remote control for consumer electronics products that nowadays are divided by the state only performs each function. In any case, there is also the case that the number of losing too many messes Where remote control. In this paper, the reason and remote control using infrared remote control transmission, will be able to see the modulation method of the received remote control method. The experiment will be able to see that by looking at the LCD to ATmega128 control home appliances (TV, air conditioning, etc.). As a result, it will be able to deal with a single remote control electronics to reduce the number of the remote control to handle all further electronics in the home.

  • PDF

Modified Finite Control Set-Model Predictive Controller (MFCS-MPC) for quasi Z-Source Inverters based on a Current Observer

  • Bakeer, Abualkasim;Ismeil, Mohamed A.;Orabi, Mohamed
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.610-620
    • /
    • 2017
  • The Finite Control Set-Model Predictive Controller (FCS-MPC) for quasi Z-Source Inverters (qZSIs) is designed to reduce the number of sensors by proposing a current observer for the inductor current. Unlike the traditional FCS-MPC algorithm, the proposed model removes the inductor current sensor and observes the inductor current value based on the deposited prior optimized state as well as the capacitor voltage during this state. The proposed observer has been validated versus a typical MPC. Then, a comparative study between the proposed Modified Finite Control Set-Model Predictive Controller (MFCS-MPC) and a linear PID controller is provided under the same operating conditions. This study demonstrates that the dynamic response of the control objectives by MFCS-MPC is faster than that of the PID. On the other hand, the PID controller has a lower Total Harmonic Distortion (THD) when compared to the MFCS-MPC at the same average switching. Experimental results validate both methods using a DSP F28335.