• Title/Summary/Keyword: Electronics

Search Result 71,331, Processing Time 0.089 seconds

Investigation of Verification and Evaluation Methods for Tampering Response Techniques Using HW Security Modules (HW 보안 모듈을 활용한 탬퍼링 대응 기술의 검증 및 평가 방안 조사)

  • Dongho Lee;Younghoon Ban;Jae-Deok Lim;Haehyun Cho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.34 no.2
    • /
    • pp.335-345
    • /
    • 2024
  • In the digital era, data security has become an increasingly critical issue, drawing significant attention. Particularly, anti-tampering technology has emerged as a key defense mechanism against indiscriminate hacking and unauthorized access. This paper explores case studies that exemplify the trends in the development and application of TPM (Trusted Platform Module) and software anti-tampering technology in today's digital ecosystem. By analyzing various existing security guides and guidelines, this paper identifies ambiguous areas within them and investigates recent trends in domestic and international research on software anti-tampering. Consequently, while guidelines exist for applying anti-tampering techniques, it was found that there is a lack of methods for evaluating them. Therefore, this paper aims to propose a comprehensive and systematic evaluation framework for assessing both existing and future software anti-tampering techniques. To achieve this, it using various verification methods employed in recent research. The proposed evaluation framework synthesizes these methods, categorizing them into three aspects (functionality, implementation, performance), thereby providing a comprehensive and systematic evaluation approach for assessing software anti-tampering technology in detail.

Added Value of Chemical Exchange-Dependent Saturation Transfer MRI for the Diagnosis of Dementia

  • Jang-Hoon Oh;Bo Guem Choi;Hak Young Rhee;Jin San Lee;Kyung Mi Lee;Soonchan Park;Ah Rang Cho;Chang-Woo Ryu;Key Chung Park;Eui Jong Kim;Geon-Ho Jahng
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.770-781
    • /
    • 2021
  • Objective: Chemical exchange-dependent saturation transfer (CEST) MRI is sensitive for detecting solid-like proteins and may detect changes in the levels of mobile proteins and peptides in tissues. The objective of this study was to evaluate the characteristics of chemical exchange proton pools using the CEST MRI technique in patients with dementia. Materials and Methods: Our institutional review board approved this cross-sectional prospective study and informed consent was obtained from all participants. This study included 41 subjects (19 with dementia and 22 without dementia). Complete CEST data of the brain were obtained using a three-dimensional gradient and spin-echo sequence to map CEST indices, such as amide, amine, hydroxyl, and magnetization transfer ratio asymmetry (MTRasym) values, using six-pool Lorentzian fitting. Statistical analyses of CEST indices were performed to evaluate group comparisons, their correlations with gray matter volume (GMV) and Mini-Mental State Examination (MMSE) scores, and receiver operating characteristic (ROC) curves. Results: Amine signals (0.029 for non-dementia, 0.046 for dementia, p = 0.011 at hippocampus) and MTRasym values at 3 ppm (0.748 for non-dementia, 1.138 for dementia, p = 0.022 at hippocampus), and 3.5 ppm (0.463 for non-dementia, 0.875 for dementia, p = 0.029 at hippocampus) were significantly higher in the dementia group than in the non-dementia group. Most CEST indices were not significantly correlated with GMV; however, except amide, most indices were significantly correlated with the MMSE scores. The classification power of most CEST indices was lower than that of GMV but adding one of the CEST indices in GMV improved the classification between the subject groups. The largest improvement was seen in the MTRasym values at 2 ppm in the anterior cingulate (area under the ROC curve = 0.981), with a sensitivity of 100 and a specificity of 90.91. Conclusion: CEST MRI potentially allows noninvasive image alterations in the Alzheimer's disease brain without injecting isotopes for monitoring different disease states and may provide a new imaging biomarker in the future.

Qualitative and Quantitative Analysis of Paper-Pencil Test Items for Exploring its Appropriateness as a Selection Tool of the Gifted in Science (과학 영재 선발 도구로서 지필 검사의 적합성 탐색을 위한 질적 및 양적 문항 분석)

  • Lee, Ki-Young;Dong, Hyo-Kwan;Hong, Jun-Eui;Kim, Hyun-Kyung;Jo, Bong-Jae
    • Journal of The Korean Association For Science Education
    • /
    • v.28 no.1
    • /
    • pp.32-46
    • /
    • 2008
  • The purpose of this study was to analyse the qualitative and quantitative characteristics of paper-pencil tests for exploring its appropriateness as a selection tool of the gifted in science. For this purpose, we developed two (internal and external) item analysis frameworks, and applied these frameworks to analyse qualitative characteristics. Also, we analysed the relationship between two characteristics. The results of analysing qualitative characteristics revealed that the portion of items with acceleration context exceeding middle school curriculum level was relatively large, which caused low content validity. Furthermore, there was considerable deviation in content and context by subject matter and year, which caused test unstability. Items measuring knowledge domain was the most prevalent, and too much weight on data interpretation & analysis domain in inquiry process skills. In case of creativity test, the portion of items measuring convergent thinking was much larger than that of divergent or associative thinking. Most of these items were represented by using pictures and tables rather than using graphs. Item types of multiple-choice and short answers were superior to essay types. Discrimination index, on the whole, was appropriate (above 0.3), but item difficulty showed a vast deviation ($0.01{\sim}0.90$). Correlation coefficients among subject matters and test tools were very low, and test reliabilities were also low. Low item difficulty & high discrimination index item types were distinguishable. Items with acceleration context were more discriminating than enrichment context. Implications of developing quality paper-pencil test items in the selection of gifted students are discussed.

Crytallization Behavior of Amorphous ${Si_{1-x}}{Ge_x)$ Films Deposited on $SiO_2$ by Molecular Beam Epitaxy(MBE) ($SiO_2$위에 MBE(Moleculat Beam Epitaxy)로 증착한 비정질 ${Si_{1-x}}{Ge_x)$박막의 결정화거동)

  • Hwang, Jang-Won;Hwang, Jang-Won;Kim, Jin-Won;Kim, Gi-Beom;Lee, Seung-Chang;Kim, Chang-Su
    • Korean Journal of Materials Research
    • /
    • v.4 no.8
    • /
    • pp.895-905
    • /
    • 1994
  • The solid phase crystallization behavior of undoped amorphous $Si_{1-x}Ge_{x}$ (X=O to 0.53) alloyfilms was studied by X-ray diffractometry(XRD) and transmission electron microscopy(TEM). Thefilms were deposited on thermally oxidized 5" (100) Si wafer by MBE(Mo1ecular Beam Epitaxy) at 300'C and annealed in the temperature range of $500^{\circ}C$ ~ $625^{\circ}C$. From XRD results, it was found that the thermal budget for full crystallization of the film is significantly reduced as the Ge concentration in thefilm is increased. In addition, the results also shows that pure amorphous Si film crystallizes with astrong (111) texture while the $Si_{1-x}Ge_{x}$ alloy film crystallzes with a (311) texture suggesting that the solidphase crystallization mechanism is changed by the incorporation of Ge. TEM analysis of the crystallized filmshow that the grain morphology of the pure Si is an elliptical and/or a dendrite shape with high density ofcrystalline defects in the grains while that of the $Si_{0.47}Ge_{0.53}$ alloy is more or less equiaxed shape with muchlower density of defects. From these results, we conclude that the crystallization mechanism changes fromtwin-assisted growth mode to random growth mode as the Ge cocentration is increased.ocentration is increased.

  • PDF

A Retrospective Study of 94 Hypercalcemic Dogs(2002-2004) (94 마리 고칼슘혈증 개들에 대한 회고연구(2002-2004))

  • Cho, Tae-Hyung;Kang, Byeong-Teck;Park, Chul;Jung, Dong-In;Yoo, Jong-Hyun;Kim, Ju-Won;Kim, Ha-Jung;Lim, Chae-Young;Lee, So-Young;Kim, Jung-Hyun;Woo, Eung-Je;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.479-485
    • /
    • 2007
  • A retrospective study of 94 hypercalcemic dogs was performed to find out most common causes that lead to hypercalcemia through investigating dogs referred to the Veterinary Teaching Hospital of Konkuk University from 2002 to 2004. During the study period, hypercalcemia was found in 94 dogs of 19 breeds, and they were evaluated as case group. Control group was made up of 94 dogs of 18 breeds without hypercalcemia admitted for the same study period. For general signalments, there were no significant differences between case and control group with the exception of age distribution. Shih-tzu(17.02%) and Yorkshire terrier(26.60%) was the most common breed in case and control group, respectively. The most common diseases associated with hypercalcemia were chronic renal failure (18.09%), acute renal failure(14.89%), and renal calculi(6.38%). Malignant neoplasia(lymphoma, hemangiosarcoma, chronic lymphocytic leukemia, mammary gland tumor, and multiple myeloma) and endocrinopathies(hyperadrenocorticism, hyperthyroidism, hypoadrenocorticism, and hypothyroidism) occupied 8.5% and 6.4%, respectively. This report is a first retrospective study of hypercalcemic dogs in South Korea.

Investigation of the Emotional Characteristics of White for Designing White Based Products (백색 제품 디자인을 위한 감성적 특성 연구)

  • Na, Noo-Ree;Suk, Hyeon-Jeong;Lee, Jae-In
    • Science of Emotion and Sensibility
    • /
    • v.15 no.2
    • /
    • pp.297-306
    • /
    • 2012
  • In this study we investigated emotional characteristics of various whites which have slightly different nuances to suggest guidelines that help designers to select appropriate colors when designing white based products. The study involved three different procedures. In experiment 1, we selected 20 emotional words through a survey (N=30) among 60 words, which we picked from literature review that was thought to be appropriate to evaluate product colors. In experiment 2, we evaluated the emotional characteristics of 13 basic colors from the I.R.I Hue & Tone 120 system (N=30) using previously selected emotional words, to find relative emotional positions of white in comparison to other colors. Based on the ratings, factor analysis was conducted and consequently four factors were extracted: flamboyant, elegant, clear, and soft. Accordingly, the emotional characteristics of the 13 colors were profiled and compared with those of white. Finally, in experiment 3, we conducted an evaluation of emotional characteristics on 25 whites with different nuances facilitating the four factors obtained in experiment 2. The color stimuli used in experiments were measured in terms of CIE 1976 $L^*a^*b^*$, and regression analysis was performed in order to predict the emotional characteristics through the L, a, and b values of a color, as long as that is perceived as a white. Throughout three empirical studies, we observed three overruling tendencies : First, there are four important factors when evaluating product color - flamboyant, elegance, clearness and softness; second, white is dominantly the most elegant in comparison to other colors; third, the emotional factors of the study were affected by some combinations of attributes of colors rather than by all three-hue, saturation and brightness. In addition, the equations derived from the regression analysis in experiment 3, it is expected that designers may predict the emotional distinction between nuances of white.

  • PDF

Design Anamorphic Lens Thermal Optical System that Focal Length Ratio is 3:1 (초점거리 비가 3:1인 아나모픽 렌즈 열상 광학계 설계)

  • Kim, Se-Jin;Ko, Jung-Hui;Lim, Hyeon-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.409-415
    • /
    • 2011
  • Purpose: To design applied anamorphic lens that focal length ratio is 3:1 optical system to improve detecting distance. Methods: We defined a boundary condition as $50^{\circ}{\sim}60^{\circ}$ for viewing angle, horizontal direction 36mm, vertical direction 12 mm for focal length, f-number 4, $15{\mu}m{\times}15{\mu}m$ for pixel size and limit resolution 25% in 33l p/mm. Si, ZnS and ZnSe as a materials were used and 4.8 ${\mu}m$, 4.2 ${\mu}m$, 3.7 ${\mu}m$ as a wavelength were set. optical performance with detection distance, narcissus and athermalization in designed camera were analyzed. Results: F-number 4, y direction 12 mm and x direction 36 mm for focal length of the thermal optical system were satisfied. Total length of the system was 76 mm so that an overall volume of the system was reduced. Astigmatism and spherical aberration was within ${\pm}$0.10 which was less than 2 pixel size. Distortion was within 10% so there was no matter to use as a thermal optical camera. MTF performance for the system was over 25% from 33l p/mm to full field so it was satisfied with the boundary condition. Designed optical system was able to detect up to 2.9 km and reduce a diffused image by decreasing a narcissus value from all surfaces except the 4th surface. From sensitivity analysis, MTF resolution was increased on changing temperature with the 5th lens which was assumed as compensation. Conclusions: Designed optical system which used anamorphic lens was satisfied with boundary condition. an increasing resolution with temperature, longer detecting distance and decreasing of narcissus were verified.

Evaluation of Planning Dose Accuracy in Case of Radiation Treatment on Inhomogeneous Organ Structure (불균질부 방사선치료 시 계획 선량의 정확성 평가)

  • Kim, Chan Yong;Lee, Jae Hee;Kwak, Yong Kook;Ha, Min Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • Purpose: We are to find out the difference of calculated dose of treatment planning system (TPS) and measured dose in case of inhomogeneous organ structure. Materials and Methods: Inhomogeneous phantom is made with solid water phantom and cork plate. CT image of inhomogeneous phantom is acquired. Treatment plan is made with TPS (Pinnacle3 9.2. Royal Philips Electronics, Netherlands) and calculated dose of point of interest is acquired. Treatment plan was delivered in the inhomogeneous phantom by ARTISTE (Siemens AG, Germany) measured dose of each point of interest is obtained with Gafchromic EBT2 film (International Specialty Products, US) in the gap between solid water phantom or cork plate. To simulate lung cancer radiation treatment, artificial tumor target of paraffin is inserted in the cork volume of inhomogeneous phantom. Calculated dose and measured dose are acquired as above. Results: In case of inhomogeneous phantom experiment, dose difference of calculated dose and measured dose is about -8.5% at solid water phantom-cork gap and about -7% lower in measured dose at cork-solid water phantom gap. In case of inhomogeneous phantom inserted paraffin target experiment, dose difference is about 5% lower in measured dose at cork-paraffin gap. There is no significant difference at same material gap in both experiments. Conclusion: Radiation dose at the gap between two organs with different electron density is significantly lower than calculated dose with TPS. Therefore, we must be aware of dose calculation error in TPS and great care is suggested in case of radiation treatment planning on inhomogeneous organ structure.

  • PDF

Study of Coherent High-Power Electromagnetic Wave Generation Based on Cherenkov Radiation Using Plasma Wakefield Accelerator with Relativistic Electron Beam in Vacuum (진공 내 상대론적인 영역의 전자빔을 이용한 플라즈마 항적장 가속기 기반 체렌코프 방사를 통한 결맞는 고출력 전자파 발생 기술 연구)

  • Min, Sun-Hong;Kwon, Ohjoon;Sattorov, Matlabjon;Baek, In-Keun;Kim, Seontae;Hong, Dongpyo;Jang, Jungmin;Bhattacharya, Ranajoy;Cho, Ilsung;Kim, Byungsu;Park, Chawon;Jung, Wongyun;Park, Seunghyuk;Park, Gun-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.6
    • /
    • pp.407-410
    • /
    • 2018
  • As the operating frequency of an electromagnetic wave increases, the maximum output and wavelength of the wave decreases, so that the size of the circuit cannot be reduced. As a result, the fabrication of a circuit with high power (of the order of or greater than kW range) and terahertz wave frequency band is limited, due to the problem of circuit size, to the order of ${\mu}m$ to mm. In order to overcome these limitations, we propose a source design technique for 0.1 THz~0.3 GW level with cylindrical shape (diameter ~2.4 cm). Modeling and computational simulations were performed to optimize the design of the high-power electromagnetic sources based on Cherenkov radiation generation technology using the principle of plasma wakefield acceleration with ponderomotive force and artificial dielectrics. An effective design guideline has been proposed to facilitate the fabrication of high-power terahertz wave vacuum devices of large diameter that are less restricted in circuit size through objective verification.

Basic Study on the Development of Analytical Instrument for Liquid Pig Manure Component Using Near Infra-Red Spectroscopy (근적외선 분광법을 이용한 돈분뇨 액비 성분분석기 개발을 위한 기초 연구)

  • Choi, D.Y.;Kwag, J.H.;Park, C.H.;Jeong, K.H.;Kim, J.H.;Song, J.I.;Yoo, Y.H.;Chung, M.S.;Yang, C.B.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.2
    • /
    • pp.113-120
    • /
    • 2007
  • This study was conducted to measure Nitrogen(N), Phosphate($P_2O_5$), Potassium ($K_2O$), Organic matter(OM) and Moisture content of liquid pig manure by Near Infrared Spectroscopy(NIRS) and to develop an alternative and analytical instrument which are used for measurement of N, $P_2O_5$, $K_2O$, OM, and Moisture contents for liquid pig manure. The liquid pig manure sample's transmittance spectra were measured with a NIRS in the wavelength range of 400 to 2,500 nm. Multiple linear regression and partial least square regression were used for calibrations. The correlation coefficient(RSQ) and standard error of calibration(SEC) obtained for nitrogen were 0.9190 and 2.1649, respectively. The RSQ for phosphate, potassium, organic matter and moisture contents were 0.9749, 0.5046, 0.9883 and 0.9777, and the SEC were 0.5019, 1.9252, 0.1180 and 0.0789, respectively. These results are indications of the rapid determination of components of liquid pig manure through the NIR analysis. The simple analytical instrument for liquid pig manure consisted of a tungsten halogen lamp for light source, a sample holder, a quartz cell, a SM 301 spectrometer for spectrum analyzer, a power supply, an electronics, a computer and a software. Results showed that the simple analytical instrument that was developed can approximately predict the phosphate, organic matter and moisture content of the liquid pig manure when compared to the analysis taken by NIRS. The low predictability value of potassium however, needs further investigation. Generally, the experiment proved that the simple analytical instrument was reliable, feasible and practical for analyzing liquid pig manure.

  • PDF