• Title/Summary/Keyword: Electronic parameters

Search Result 2,459, Processing Time 0.028 seconds

A Load Balancing Method using Partition Tuning for Pipelined Multi-way Hash Join (다중 해시 조인의 파이프라인 처리에서 분할 조율을 통한 부하 균형 유지 방법)

  • Mun, Jin-Gyu;Jin, Seong-Il;Jo, Seong-Hyeon
    • Journal of KIISE:Databases
    • /
    • v.29 no.3
    • /
    • pp.180-192
    • /
    • 2002
  • We investigate the effect of the data skew of join attributes on the performance of a pipelined multi-way hash join method, and propose two new harsh join methods in the shared-nothing multiprocessor environment. The first proposed method allocates buckets statically by round-robin fashion, and the second one allocates buckets dynamically via a frequency distribution. Using harsh-based joins, multiple joins can be pipelined to that the early results from a join, before the whole join is completed, are sent to the next join processing without staying in disks. Shared nothing multiprocessor architecture is known to be more scalable to support very large databases. However, this hardware structure is very sensitive to the data skew. Unless the pipelining execution of multiple hash joins includes some dynamic load balancing mechanism, the skew effect can severely deteriorate the system performance. In this parer, we derive an execution model of the pipeline segment and a cost model, and develop a simulator for the study. As shown by our simulation with a wide range of parameters, join selectivities and sizes of relations deteriorate the system performance as the degree of data skew is larger. But the proposed method using a large number of buckets and a tuning technique can offer substantial robustness against a wide range of skew conditions.

Ion Exchange of Copper from Sulphate Effluent using DOWEX G-26 (황산용액(黃酸溶液)으로부터 DOWEX G-26에 의한 구리의 회수(回收))

  • Nguyen, Nghiem Van;Lee, Jae-Chun;Jha, Manis Kumar;Kim, Min-Seuk;Jeong, Jin-Ki;Hwang, Taek-Sung
    • Resources Recycling
    • /
    • v.17 no.4
    • /
    • pp.37-46
    • /
    • 2008
  • In view of the increasing importance of the waste recycling to meet the strict environmental regulations, the present investigation reports an adsorption process using cationic exchanger DOWEX G-26 for the recovery of copper from the synthetic sulphate solutions containing copper 0.3 to 0.5 mg/ml, similar to the CMP waste effluent of electronic industry. Various process parameters viz. contact time, solution pH, resin dose, and A/R ratio for elution were investigated to recover copper from the effluents. Complete adsorption of copper from the solution was achieved at equilibrium pH 2.5 and aqueous I resin (A/R) ratio of 100 ml/g in 14 minutes contact time. The adsorption of copper on DOWEX G-26 resin was found to follow the Langmuir isotherm and second order reaction. The copper was eluted from loaded resin with dilute sulphuric acid to produce copper-enriched solution.

Practical Approach to the Diagnosis of Pediatric Nasal Bone Fractures (소아 환자의 코뼈 골절 진단을 위한 실제적 접근)

  • Lee, Yulkok;Oh, Sungchan;Cho, Sukjin;Kim, Hyejin;Kang, Taekyung;Choi, Seungwoon;Yoo, Hanbin;Ryu, Seokyong
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.95-100
    • /
    • 2014
  • Purpose: Nasal bone fractures are the most common childhood facial bone fractures, with an incidence of about 39%. While taking a nasal bone x-ray is a common modality used in the emergency department, reports have expressed concerns with its low sensitivity and low specificity. Our study was aimed at comparing accuracy of physical and x-ray examination with that of facial bone computed tomography (CT). Methods: Electronic medical records (EMR) were retrospectively reviewed for patients under the age of 15 who visited our emergency department from January 2010 to December 2011with a chief complaint of nasal pain due to trauma and who had also undergone a nasal bone x-ray and facial bone CT. Patients who had not taken facial bone CT, who had been transferred, and who did not have EMR were excluded. We divided the patients into 2 groups, those who had nasal bone fractures and those without a fracture on their facial bone CT. We analyzed other parameters such as age, sex, and type of fracture to find statistical differences between the two groups. Results: A total of 209 patients were included. The patients with nasal bone fractures on their facial bone CT were older, and their traumas were more violent. Ten patients who had apparent nasal bone fractures on their facial bone CT had no definite signs of a fracture on their plain x-ray. Conclusion: Though facial bone CT is an effective modality in detecting nasal bone fractures, in evaluating younger patients suspected of having nasal bone fractures, prudent use of facial bone CT is needed to reduce unnecessary exposure to radiation.

Development of Auto-spray system to improve the quality of 3D Scanning Quality (3D 스캔 시 품질향상을 위한 스프레이 도포 자동화 장비 개발)

  • Kim, Wonseop;Jo, Jae Heung;Kim, Dongsu;Kim, Donggyoo;Hong, Seokmoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.100-105
    • /
    • 2016
  • The use of 3D scanners has increased gradually according to increasing 3D printer applications. The precision inspection of car parts or electronic components is an important issue not only in the field of mass production, but also in small-scale production. Recently, 3D scanner equipment efficiency and recognition technology has been improved continuously. On the other hand, the spraying time to prepare 3D scanning is time-consuming and has environmental problems. Therefore, an automatic spray system has been in demand by the manufacturing industry. Automatic spray equipment was newly developed for the preparation of a 3D scanner. In this research, the automatic spray system guarantees uniform spray operation. To determine the optimal spray parameters, various spraying methods, solutions and conditions were tested and compared with the experiments. The preparation time for 3D scanning was reduced to 1/10 compared to the manual spraying time, and indicates the optimal spraying conditions through a comparison of various spray coating conditions.

The hyperfine interaction in water-solvent system (물-용매계에서의 초미세 상호작용)

  • Lee, Mi-Nyeong;Kim, Tae-Kwan;Lee, Sung-Ki;Park, Yoon-Chang
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.194-200
    • /
    • 2005
  • The N hyperfine coupling constants ($a_N$) of di-t-butyl nitroxide (DTBN) radicals in water-solvent system were measured with EPR spectroscopy. Various kinds of the solvents with different polarity such as acetone, dimethylsulfoxide (DMSO), methanol, ethanol and 1-propanol were applied and studied. Equilibrium constants for the solvation equilibrium and the solvent parameters ($E_T$, molar transition energy) of various water-solvent system were obtained from the experimental results and are presented. The $a_N$ values were plotted as a function of mole fraction of the solvent. In case of water-DMSO, water-ethanol and water-1-propanol system, slight negative deviations from the straight line were observed. In water-acetone system, the absorption wavelength (${\lambda}$) due to ${\eta}{\rightarrow}{\pi}^{\ast}$ transition increased linearly with the increase of mole fraction of acetone. The relationship between $a_N$ of DTBN and ${\lambda}$ due to ${\eta}{\rightarrow}{\pi}^{\ast}$ transition in water-acetone and water-DMSO system was examined. It was found that the electronic structure of the nitroxide radicals is stablized from the fact that the N hyperfine coupling constants of DTBN radicals are greatly unaffected in the environment of water-solvent system.

A Study on A Mathematical Formulation of Protection Ratio and Its Calculation for Fixed Radio Relay System with Diversity (다이버시티를 갖는 고정 무선 중계 시스템에 대한 보호비의 수학적 표현과 계산에 대한 연구)

  • Suh Kyoung-Whoan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.107
    • /
    • pp.358-367
    • /
    • 2006
  • In this paper, a mathematical formulation of protection ratio and its calculation method are suggested for a radio relay system with diversity techniques. The analysis of protection ratio and its physical meaning have been performed for the space or frequency diversity system, and in particular protection ratios are reviewed in terms of the parameters of diversity improvement factor, which comprises antenna gain, separation distance between antennas, frequency and its difference between carriers, and distance. As one of simulated results, the co-channel protection ratio of 60 dB is obtained for the space diversity system regarding 6.2 GHz, 60 km, 64-QAM, and 25 m between antennas, which gives 15 dB less than the co-channel protection ratio of the non-space diversity system. In addition, the co-channel protection ratio for the frequency diversity system gives 64 dB in case of frequency offset of 0.5 GHz under the same conditions as the space diversity system, which brings about 11 dB less than the co-channel protection ratio of non-frequency diversity system. In consequency, it is interesting to note that the space diversity system is less sensitive to interference in comparison to the frequency diversity system and provides better quality of service for a given interference.

Design and Implementation of Monopole Antenna with Parasitic Element of Spiral Shape and L-Resonator (스파이럴 구조 기생 소자와 L자형 공진기를 갖는 모노폴 안테나 설계 및 구현)

  • Yoon, Kwang-Yeol;Lee, Seungwoo;Kim, Jang-Yeol;Rhee, Seung-Yeop;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.1
    • /
    • pp.11-19
    • /
    • 2013
  • In this paper, we designed and implemented the planar monopole antenna using the coupling effect for the multi-band characteristic. A parasitic element for the multi-band characteristic based on a rectangular patch with single resonance is inserted. Spiral shaped parasitic element is used for minimizing the antenna size and obtaining the multi-resonance characteristic. The frequency characteristics are modified and optimized by varying specific parameters. By inserting an L-shaped resonator at both sides of the feed line which connected through the via hole to the ground plane, unnecessary frequency bands are eliminated. Proposed antenna dimension is $40{\times}60{\times}1mm^3$. It is fabricated on the FR-4 substrate(${\varepsilon}_r$=4.4) using a microstrip line of $50{\Omega}$ for impedance matching. By measurement results, the characteristic of the return loss under -10 dB are 1.714~2.496 GHz, 2.977~4.301 GHz, and 4.721~6.315 GHz, and the radiation patterns have omni-directional shapes.

A CLINICAL AND RADIOLOGICAL STUDY ON THE EFFECT OF SYNTHETIC BONE IN CLASS II AND III FURACATION INVOLVEMENTS (2급 및 3급 치근이개부 병변에서 합성골이식의 효과에 대한 임상적 및 방사선학적 연구)

  • Yum, Kyu-Sun;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.475-492
    • /
    • 1993
  • The effect of synthetic bone materials was assessed in the patients with pure periodontal class II and III furcation defects. The buccal aspects of the maxillary and mandilular first and second molars were surgically exposed, and synthetic bone materials were interposed between the gingival flap and the furcation defects in the experimental group. The control group were treated without the use of synthetic bone materials by same operator. Probing pocket depth, gingival recession, and loss of attachment, were measured by Michigan O-probe and tooth mobility was evaluated by an electronic mobility tester(Periotest(R), Siemens co. Germany) at preoperation and 3-, 6-, and 12-month postoperation. Standardized radiogrphs were taken at preoperation and 6-month and 12-month postoperation. The postoperative change of clinical parameters and the difference between experimental group and control group were statistically analyzed by Student, t-test. The results were as follows: 1. The probing pocket depth at the 3-, 6-, and 12-month postoperative examination was significantly decreased, compared to that at preoperative examination in both experimental group and control group(P<0.005), but there was no significantly difference between experimental group and control group. 2. The amount of gingival recession at the 3-, 6-, and 12-month postoperative examination was increased, compared to that at the preoperative examination in both experimental and control group(P<0.005). In the case of the class III furcation involvement, the amount of gingival recession at the 3-, 6-, and 12-month postoperative examination was more significantly increased in control group than experimental group(P<0.05). 3. The amount of loss of attachment at the 3-, 6-, and 12-month postoperative examination was significantly decreased, compared to that at the preoperative examination in both experimental and control group in the case of class II furcation involvement, and in experimental group only in the case of furcation III involvement(P<0.005). The amount of loss of attachment at, the 3-, 6-, and 12-month postoperative examination was more significantly decreased in experimental group than control group in the case of the class III furcation involvement(P<0.05), but in the case of class II furcation involvement there was no significant difference between experimental group and control group. 4. The tooth mobility at the 3-, 6-, and 12-month postoperative examination was significantly decreased, compared to that at the preoperative examination in both experimental and control group(P<0.005), but there was no significant difference between experimental group and control group. 5. Radiopacity of furcation area was greatly increased in the experiment group, but there was no radiographic change in the control group.

  • PDF

Development of the EM wave Absorber for Improving the Performance of Hi-Pass System in ITS (ITS에 있어서 Hi-Pass 시스템의 성능 개선을 위한 전파흡수체의 개발)

  • Kim, Dong Il;Kim, Jeong Chang;Joo, Yang Ick
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1505-1510
    • /
    • 2014
  • High-Pass (ETC ; Electronic Toll Collection) system is one of the basic elements, which adopts a wireless communication method using 5.8 GHz and can realize a part of ITS (Intelligent Traffic System). On the other hand, communication errors occur frequently in Hi-Pass system due to signal erros, multi-path reflection, and/or system-to-system interferences. To solve these problems, an EM (Electro-Magnetic) wave absorber can be used. To solve these Problems, we fabricated some samples in the different composition ratios of Carbon, Sendust, and CPE, and it was confirmed that the optimum composition ratio of Carbon : Sendust : CPE is 10 : 40 : 50 wt.%. The complex relative permittivity and complex relative permeability were derived by using the measured data. In addition, the optimum design parameters for the absorber were determined by simulation. Then the absorption abilities were calculated by changing the thickness of the EM wave absorbers. As a result, the optimum thickness of the developed EM wave absorber was 2.85 mm with absorption ability over 22.4 dB at 5.8 GHz. Futhermore, the EM wave absorber was fabricated based on the simulated and designed values. The measured values agreed well with the simulated ones. Therefore, it was clearly shown that the developed EM wave absorber in this paper is to be applied in actual situations.

The Comparative Study of NHPP Software Reliability Model Based on Log and Exponential Power Intensity Function (로그 및 지수파우어 강도함수를 이용한 NHPP 소프트웨어 무한고장 신뢰도 모형에 관한 비교연구)

  • Yang, Tae-Jin
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.6
    • /
    • pp.445-452
    • /
    • 2015
  • Software reliability in the software development process is an important issue. Software process improvement helps in finishing with reliable software product. Infinite failure NHPP software reliability models presented in the literature exhibit either constant, monotonic increasing or monotonic decreasing failure occurrence rates per fault. In this paper, proposes the reliability model with log and power intensity function (log linear, log power and exponential power), which made out efficiency application for software reliability. Algorithm to estimate the parameters used to maximum likelihood estimator and bisection method, model selection based on mean square error (MSE) and coefficient of determination($R^2$), for the sake of efficient model, was employed. Analysis of failure, using real data set for the sake of proposing log and power intensity function, was employed. This analysis of failure data compared with log and power intensity function. In order to insurance for the reliability of data, Laplace trend test was employed. In this study, the log type model is also efficient in terms of reliability because it (the coefficient of determination is 70% or more) in the field of the conventional model can be used as an alternative could be confirmed. From this paper, software developers have to consider the growth model by prior knowledge of the software to identify failure modes which can be able to help.