• Title/Summary/Keyword: Electronic modules

Search Result 491, Processing Time 0.029 seconds

Determination Method for Topology Configuration of Hybrid Cascaded H-Bridge Rectifiers

  • Zhuang, Yuan;Wang, Cong;Wang, Chang;Cheng, Hong;Gong, Yingcai;Wang, Hao
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1763-1772
    • /
    • 2016
  • To reduce system complexity and implementation costs, fully-controlled H-bridge (FHB) modules and diode H-bridge PFC (DHB) modules are cascaded to form a hybrid cascaded H-bridge rectifier (HCHR). In this paper, the advantages of such a HCHR over other cascaded rectifiers are analyzed depending on the numbers of FHB modules and DHB modules. Therefore, to assign proper numbers to these two kinds of modules for the HCHR, a configuration determination method is investigated under balanced and imbalanced loads. Three principles are also presented to guide the configuration determination for the HCHR. In addition, the constraints for selecting the step-up ratio and filter inductance are derived based on a phasor diagram analysis. The proposed configuration determination method is validated by simulations under three different conditions in the PSIM environment. Finally, experiments are carried out on a scaled-down prototype where the configuration can be easily adjusted. The feasibility of the proposed theory is then verified by experimental results.

An I/O Bus-Based Dual Active Fault Tolerant Architecture fort Good System Performance

  • Kwak, Seung-Uk;Kim, Jeong-Il;Jeong, Keun-Won;Park, Kyong-Bae;Kang, Kyong-In;Kim, Hyen-Uk;Lee, Kwang-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.515-520
    • /
    • 1998
  • In this paper, we propose a new fault tolerant architecture for high availability systems, where for module internal operations both processor modules perform the same tasks at the same time independently of each other while for module external operations both processor modules act actively. That is, operations of synchronization between dual processor modules except clock synchronization are requested only when module external operations are executed. The architecture can not only improve system availability by reducing system reintegration time but also reduce performance degradation problem due to frequent synchronization between dual processor modules. The clock unit consists of a clock generator and a clock synchronization circuit. This supplies a stable clock signal under clock unit disorder of any processor module or rapid clock signal variation. And this architecture achieves system availability and data credibility by designing as symmetrical form.

  • PDF

The Electrical Characteristics of Spot Light Solar Cell Modules (집광형 태양전지 모듈의 전기적 특성에 관한 연구)

  • Kim, Beum-Jun;Kang, Ey-Goo;Lyu, Se-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.6
    • /
    • pp.440-444
    • /
    • 2011
  • We have analyzed electrical characteristics of spot light solar cell modules and have completed fabrication of spot light solar cell modules. Before we test modules, we have carried about UV test of hologram. As a result of test, we have obtained 165% efficiency of hologram film. the other hand, we obtained 75% efficiency of general films. After we have fabricated solar modules and carried about field test, spot light solar cell modules with hologram have been investigated 17.3 A of Isc and 155.4 W of power.

Outdoor Testing and Degradation of EVA and POE Encapsulated Photovoltaic Modules (옥외 관측을 통한 EVA, POE PV모듈의 열화 연구)

  • Kim, Jeha
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.12
    • /
    • pp.847-852
    • /
    • 2016
  • Using both EVA and POE encapsulants, we fabricated polycrystalline Si PV modules and performed a set of reliability tests of PID, DH, TC, and Complex prior to outdoor installation. The power output with temperatures and insolation as well as I-V characteristics had been monitored under outdoor environments for 18 months. In the entire period, the total power of 3,576 kWh from POE PV modules was observed larger than 3,449 kWh from EVA PV modules by 3.5%. All the PV modules showed a 5.6~9.2% drop in the conversion efficiency. As for the solar power generation, the PV modules performed through PID, TC test revealed distinct difference in between EVA and POE for which the POE PV module produced more power by +11.4% and +6.6%, respectively, as measured in the 18th month. In addition, POE was proved to protect better the solar cells under PID influence.

Implementation of Measuring Modules for Unmanned Remote Supervisory System using Mobile Communication Network (이동통신망을 이용한 무인 원격감시 시스템용 계측 모듈의 구현)

  • Park, Jung-Hoon;Hong, Sung-Hoon;Seo, Kang-Myun;Kang, Moon-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2416-2418
    • /
    • 2000
  • The new-type measuring modules for unmanned remote supervisory system using mobile communication network have been designed in this study. Measuring modules consist of temperature measuring module, humidity measuring module and human body sensing module. And we will design a main part to collect and process informations of each modules, evaluate reliability of combined total system.

  • PDF

A Case Study on Determining the Number of Spare Modules in Power Plant Control System Used for Long Term (장기사용 발전소 제어시스템의 예비모듈 수 결정 사례)

  • 정창기;신윤오;박정원;함중걸
    • Journal of Korean Society for Quality Management
    • /
    • v.28 no.1
    • /
    • pp.210-219
    • /
    • 2000
  • When an electronic control system has been used for long time, the electronic control system becomes obsolete and no longer In production. In this case, the existing control system should replace by new system due to shortage of spare modules. However, if the proper number of spare modules are stocked, it may be possible and more economical than to replace by new system to extend the usage period of the existing control system. In this case, it is an important problem to determine the proper number of spare modules. In this paper, a method to determine the proper number of spare modules is presented with an application example.

  • PDF

Temperature Measurement of Photovoltaic Modules Using Non-Contact Infrared System

  • Jovanovic, Ugljesa;Mancic, Dragan;Jovanovic, Igor;Petrusic, Zoran
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.904-910
    • /
    • 2017
  • This paper presents temperature measurement of solar photovoltaic modules using the custom-made system composed of an infrared temperature sensor and a microcontroller. The obtained measurement results are processed, displayed and stored on a PC using the custom-made virtual instrument. The proposed system overcomes some of the problems related to the contact sensor application, and at the same time offers accurate readings and better flexibility. The proposed system is especially suitable for applications where the cost is a limiting factor in the choice of measuring system. The conducted analysis and the obtained results have shown an excellent accuracy of the proposed system in comparison to a high quality thermal imaging camera used as the reference instrument.

A Study on How to Minimize the Luminance Deviation of AC-LED Lighting (교류 LED 조명의 빛 밝기 편차를 최소화하는 방법에 대한 연구)

  • Dong Won Lee;Bong Hee Lee;Byungcheul Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.3
    • /
    • pp.255-260
    • /
    • 2023
  • In order to spread LED lighting, LED lighting technology directly driven by alternating current (AC) commercial power has recently been introduced. Since current does not flow at a voltage lower than the threshold voltage of the LED, a non-conductive section occurs in the current waveform, and the higher the threshold voltage of the LED, the more discontinuous current waveforms are generated. In this paper, multi-LED modules are connected in series so that the threshold voltage can be adjusted according to the number of LED modules. A small number of LED modules are driven at a low instantaneous rectified voltage, and a large number of LED modules are driven at a high instantaneous rectified voltage to lengthen the overall lighting time of AC-LED lighting, thereby minimizing the luminance deviation of AC-LED lighting. In addition, the load current flowing through the LED module is adjusted to be the same as the design current even at the maximum rectified voltage higher than the design voltage, so that the light brightness of the LED module is kept constant. Therefore, even if the rectified voltage applied to the LED module changes, the AC-LED lighting in which the light brightness is constant and the luminance deviation is minimal has been realized.

Development of High Density High Voltage Power Supply for Traveling Wave Tubes (진행파관(TWT) 구동용 고밀도 고전압 전원공급기 개발)

  • Park Y.J;Lee K.S;Lyu S.C.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.256-259
    • /
    • 2003
  • In this paper describes the development testing results of high density High Voltage Power Supply(HVPS) that employ microwave TWTs. The HVPS consist of number of modules connected in series. A new design that adapt resonant circuit and high density pulse transformer to the high voltage modules makes the HVPS much more reliable. Also High voltage Solid-State modulation using fast switching devices(FET's) and the test results of modulator modules development are represented.

  • PDF

Forced Convective Cooling Characteristics with Stacked Modules of Multi-PCBs' in Telecommunication Cabinet (다중 PCB 적층 모듈구조의 정보통신용 캐비넷 강제대류 냉각특성 연구)

  • Kim, W.T.;Kim, K.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.230-239
    • /
    • 1996
  • A multi-faceted experimental investigation has been carried out to study the cooling performance for stacked modules in arrays of heat generating rectangular modules deployed along PCB's in the enclosed cabinet. The main parameters which have an important effect on cooling characteristics are flow velocity, channel spacing, installation of fan unit, attachment of heat sink, and acoustic noise. The results of individual effect are very helpful for the electronic packaging designer. In order to improve the cooling performance, it is certain that the enlargement of channel space is obviously effective, while this id disadvantageous in high density electronic packaging. Each of the paameters is quantitatively examined as cooling performance and the correlation of Reynolds number to Nusselt number is compared with previous study.

  • PDF