• Title/Summary/Keyword: Electronic instrument

Search Result 300, Processing Time 0.041 seconds

The Design of MSC(Multi-Spectral Camera) System Operation

  • Yong, Sang-Soon;Kong, Jong-Pil;Heo, Haeng-Pal;Kim, Young-Sun;Park, Jong-Euk;Paik, Hong-Yul;Ra, Sung-Woong
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.825-827
    • /
    • 2003
  • Multi-Spectral Camera(MSC) is a payload on the KOMPSAT-2 satellite to perform the earth remote sensing. The instrument images the earth using a push-broom motion with a swath width of 15 km and a ground sample distance (GSD) of 1 m over the entire field of view (FOV) at altitude 685 Km. The instrument is designed to have an on-orbit operation duty cycle of 20% over the mission lifetime of 3 years with the functions of programmable gain/ offset and on-board image data compression/storage. The MSC instrument has one(1) channel for panchromatic imaging and four(4) channel for multi-spectral imaging covering the spectral range from 450nm to 900nm using TDI CCD Focal Plane Array (FPA). In this paper, the architecture and function of MSC hardware including electrical interface and the operation concept which have been established based on the mission requirements are described. And the design and the preparation of MSC system operation are analyzed and discussed.

  • PDF

Instrument of building outer wall window cleaning robot and controller layout that use vacuum adsorption technology (진공흡착 기술을 사용한 건물외벽 유리창 청소 로봇의 구현)

  • Lee, Dong-Kwang;Kim, Myung-Jong;Kwon, Soon-Won;Choi, Mun-Sik;Im, Young-Hoon;Kong, Jung-Shik;Jang, Mun-Suk;Kwon, Oh-Sang;Lee, Eung-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.259-260
    • /
    • 2007
  • 본 논문은 건물 외면의 유리창 청소로봇에 관한 것으로, 더욱 세부적으로는 청소 시스템을 갖춘 로봇을 사람이 닦기 힘들거나 위험한 고층건물이나 아파트 둥의 실외 유리창에 흡착시켜 청소로봇을 이용하여 실외 유리창을 자동으로 닦을 수 있게 하는 건물 외면의 유리창 청소로봇에 관한 것이다. 진공펌프를 사용하여 유리창에 안정적으로 흡착할 수 있도록 하였고, 블루투스를 이용하여 무선 조종이 가능하도록 하여 사용자가 원거리에서 로봇의 청소를 제어할 수 있도록 하였다.

  • PDF

Implementation of 4-Channel Electrolyte Analyzer using ISFET Microsensors (ISFET 마이크로센서를 이용한 4-채널 전해질 분석기의 구현)

  • Bae, S.K.;Kim, K.Y.;Won, C.H.;Cho, B.W.;Kim, C.S.;Sohn, B.K.;Cho, J.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.22-26
    • /
    • 1996
  • In this paper, we designed 4-channel electrolyte analyzer that can measure simultaneousely the 4 electrolytes - pH, $pNa^{+}$, $pCa^{2+}$, and $pK^{+}-$ using 2-point calibration and implemented it. Developed electrolyte analyzer consists of singal processing part, actuator part and control unit for sample flow system. To implement reliable instrument, design considerations are emphasized on flow system and sample chamber that requires small sample volume and prevent air contact with sample solution. In addition to the hardware design, we developed system software which controls full measuring process. After system developed, we verified the system performance by the test measurement for pH, $pNa^{+}$, $pCa^{2+}$, and $pK^{+}$ value.

  • PDF

A Low-Cost Method to Evaluate Absorber Reflectivity Using an Antenna with a Small Radiating Aperture and Frequency-Domain Instrument

  • Oh, Soon-Soo;Lee, Young Hwan
    • ETRI Journal
    • /
    • v.35 no.6
    • /
    • pp.1148-1151
    • /
    • 2013
  • We propose a way to measure the absorber reflectivity at a low cost. Only one simple antenna with a small radiating aperture and a frequency-domain instrument are utilized. The previously used equation for calculating the reflectivity of an absorber is inaccurate, and, therefore, a new equation is derived based on multiple reflection analysis and three test models. Notably, the reflection coefficient of the antenna is included in the derived equation. The accuracy of the proposed method is proven through simulation and measurements. It can be easily applied to a product examination by absorber manufacturers and customers owing to its advantages of simplicity, cost effectiveness, and non-cutting examination.

Research on the Making Technology of Virtual Orchestral Instrument

  • Wang, Yan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.1
    • /
    • pp.77-87
    • /
    • 2017
  • In this paper, we propose an analysis of the sound source of virtual orchestral music in detail by using the production technology of sampling and playback, and technical experiments and verification for the most advanced Hollywood Library series of timbre and the timbre production and control technology of Vienna instrument Pro and other softwares, to find their solutions and come up with the best timbre production method for orchestral music from the perspective of the specific design ideas of the productions of virtual orchestral instruments. The so-called virtual orchestral instruments are non-real orchestral instruments, which are based on the imitation of timbre of real orchestral instruments, processed and synthesized through the scientific and technological means, and produced by the use of electronic equipments or computers. The study of virtual timbre production technology is very important, and it is like the study of composers' creative techniques. Not only scientific and advanced timbre production methods can be obtained from the study, but also new ways of future timbre production are expected to be explored.

A Recording System For Nuclear Radation Detection by Means Of Circular Radial Deflection (원형방사상편향에 의한 방사능계측용 기록장치)

  • 이희용
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.3 no.3
    • /
    • pp.14-21
    • /
    • 1966
  • In this article, a recording system for nuclear radiation detection by means of circular radial deflection as an instrument and its applications are described. In the electronic circuit of the instrument, the linearity of a deflected pulse on a circular sweep is especially contribed by employing a multiplying circuit, not to mention the one of a circular time base itself. A sequence of random pulses was recorded on a circular sweep of the CRT screen by means of one cycle unblanking due to a logic circuit. It seems that the intrument is suitable for measuring a decay curve of a short-lived nuclide and its pulse spectrum

  • PDF

Development of A Multipurpose Passive Type Radon Monitor (다목적 수동형 라돈농도 측정기 개발)

  • Lee, Bong-Jae;Park, Yeong-Ung
    • Radioisotope journal
    • /
    • v.21 no.4
    • /
    • pp.55-65
    • /
    • 2006
  • A passive type radon monitor adopting two silicon PIN detector as radiation detector has been developed, manufactured and test-evaluated. A radiation signal processing circuit has been electronically tested and then the radiation detection characteristics of this instrument has been performance-tested by using reference radon concentration and a reference photon radiation field. As a result, in a electronic performance test, radiation signals from each detector were well observed in each signal processing circuit. The radiation detection sensitivity of this instrument after several test-irradiations to a Cs-137 gamma radiation source and a standard radon concentration appeared to be 1.37 cph/$\mu$Svh-1 and 1.66 pCi/L respectively. The developed radon monitor in this paper could be used conveniently in monitoring of radon concentration in buildings which population utilize in Korea.

  • PDF

Fabrication and Characterization of Portable Electronic Nose System using Gas Sensor Array and Artificial Neural Network (가스센서 어레이와 인공 신경망을 이용한 소형 전자코 시스템의 제작 및 특성)

  • 홍형기;권철한;윤동현;김승렬;이규정
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.99-102
    • /
    • 1997
  • An electronic nose system is an instrument designed far mimicking human olfactory system. It consists generally of gas (odor) sensor array corresponding to olfactory receptors of human nose and artificial neural network pattern recognition technique based on human biological odor sensing mechanism. Considerable attempts to develop the electronic nose system have been made far applications in the fields of floods, drinks, cosmetics, environment monitoring, etc. A portable electronic nose system has been fabricated by using oxide semiconductor gas sensor array and pattern recognition technique such as principal component analysis (PCA) and back propagation artificial neural network The sensor array consists of six thick film gas sensors whose sensing layers are Pd-doped WO$_3$ Pt-doped SnO$_2$ TiO$_2$-Sb$_2$O$_3$-Pd-doped SnO$_2$ TiO$_2$-Sb$_2$O$_{5}$-Pd-doped SnO$_2$+Pd filter layer, A1$_2$O$_3$-doped ZnO and PdCl$_2$-doped SnO$_2$. As an application the system has been used to identify CO/HC car exhausting gases and the identification has been successfully demonstrated.d.

  • PDF

DSP Embeded Hardware for Non-contact Bio-radar Heart and Respiration Rate Monitoring System (DSP를 이용한 비 접촉식 도플러 바이오 레이더 생체신호 모니터링 시스템 임베디드 하드웨어의 개발)

  • Kim, Jin-Seung;Jang, Byung-Jun;Kim, Ki-Doo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.4
    • /
    • pp.97-104
    • /
    • 2010
  • In this paper, we provide an embedded type non-contact bio-radar heart and respiration rate monitoring system. We implemented the rate finding algorithm into the embedded system. The high-speed and reliable real-time signal processor is then tested. To avoid null-point data loss problem, we applied quadrature demodulation. Among several other combining techniques, we suggest arctangent demodulation for quadrature channel combining and DSP is used for real-time signal processing. We also suggest DC-offset compensation technique to preserve the wanted DC components of the IQ signals for accurate demodulation while keeping the dynamic range of the ADC lower. Using Texas Instrument C6711 series DSP and external 12Bit ADC, we implemented proper elliptic digital filter and autocorrelation detection algorithm for robust commercial hand held device.