• Title/Summary/Keyword: Electronic instrument

Search Result 302, Processing Time 0.03 seconds

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Kim, Eung-Sik;Kim, Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2433-2440
    • /
    • 2009
  • Whole system and network for supply of electric power and electricity safety are essential element. Electricity safety technology need rating for product and research about certification as product development that is done electric power u-IT cotton flannel mixed with development of u-IT, u-City base technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power u-IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication module about function of product for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in electric leakage, high voltage, Arc, fire detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

A Study on Vibration Control of Port Structure using Immunized PID Controller (Immunized PID 제어기를 이용한 항만 구조물의 진동제어에 관한 연구)

  • Lee, Young-Jin;Lee, Kwon-Soon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.29 no.1
    • /
    • pp.399-404
    • /
    • 2005
  • In this paper, An immunized PID(I-PID) controller based on cell mediated immune response is proposed to improve the control performance of the controller with PID scheme. And it is applied to the vibration of the building structure in the port with active damper systems. The immune system of organism in the real body regulates the antibody and T-cells to protect the attack from the foreign materials which are virus, germ cell, and other antigens. It has similar characteristics that are the adaptation and robustness to overcome disturbances and to control the plant of engineering application. At firstly, we build a model of the T-cell regulated immune response mechanism. We have also designed an I-PID controller focusing on the T-cell regulated immune response of biological immune system. Finally, we show that some computer simulations of the vibraton control for the building structure system with wind force excitation. These results for the proposed method also show that is has performance than other conventional controller design method.

  • PDF

A Study on Super Resolution Algorithm to Improve Spatial Resolution of Optical Signals (광신호의 공간 해상도 향상을 위한 초 분해능 알고리즘 연구)

  • Lee, Byung-Jin;Yu, Bong-Guk;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.1
    • /
    • pp.71-77
    • /
    • 2018
  • The optical time domain reflectometer (OTDR) is the most widely used method to monitor problems with currently installed optical fibers. The OTDR is an instrument designed to test the FTTx network and evaluates the physical properties of the fiber, such as transmission loss and connection loss. It is important to improve the spatial resolution in order to accurately grasp the optical path problems by using the OTDR. When the pulse width is less than twice the distance between the two reflectors, the signals reflected from the two reflectors are reflected without overlap, so that the reflected signal can be distinguished. However, when the pulse width is larger than twice the distance between the two reflectors, so that the reflected signal can not be distinguished. In order to overcome these limitations, this paper proposed a method of improving spatial resolution by applying a super resolution algorithm. As a result of the simulation, the resolution is improved when the super resolution algorithm is applied, and the event interval can be analyzed more precisely.

A Study on the Development of Smart Control Valve (스마트 컨트롤 밸브 개발에 관한 연구)

  • Choi, Young-Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.6
    • /
    • pp.582-590
    • /
    • 2019
  • As Korea's low fertility and aging progress, Korea is facing a social change such as an increase of one generation by entering an aging society that has raised 14% of the population. An effective way to prevent a gas fire accident caused by an increase in one generation in an aging society is to install a control valve to forcibly shut off the gas after a set time. In this study, we developed a valve that can be opened and closed by rotating the valve left and right by transmitting power to the worm gear and the helical gear by using a motor by pressing the switch. It is easy to assemble and inspect by developing a dedicated valve that is easy to attach and detach. It was developed to enhance competitiveness by reducing cost by reducing the number of parts and product size. In addition, through endurance test, it was developed to be used for more than 9 years by repeating ON / OFF once every 12 seconds so that it can operate stably for 10,000 times for 34 hours. The instrument and PCB were designed using solid works and Altium Designer tools. Firmware development was developed in IAR Embedded Workbench environment.

A Study of the normativeness on the Influence of the Memphis on the Comtemporary Fashion Design - Focused on the End of the 20th Century - (멤피스(Memphis)디자인이 현대 패션에 미친 조형적 특징에 관한 연구 -20세기말을 중심으로-)

  • 임영자;한윤숙
    • Journal of the Korean Society of Costume
    • /
    • v.51 no.1
    • /
    • pp.5-20
    • /
    • 2001
  • The purpose of this study suggest the fashion of communication for 21th century fashion. Especially, Memphis fashion have the possibility of communicating through objects. The results of this study are as follows : First, Memphis idea is to make design into a sophisticated, conscious instrument of communication. As the Memphis fashion points out : design is an extraordinary tool for communicating because its intrinsic characteristic is the fact that it is used and distributed anyway, even without communicating anything. The Memphis fashion is trying to connect design and industry to the broader culture within which fashion moves. Second, Using different materials provides not only new structural Possibilities. but - above all - new semantic and metaphoric possibilities, order modes of communication, another language, and even a change of direction, broadening of perspective, appropriation and digestion of new values and the concomitant rejection of traditional structures that renewal always Involves. The memphis fashion works on the fabric of contemporaneity (lurex yarn, latex, chrome metal and steel) and contemporaneity means computers, electronics, a new awareness of the body. mass exercise and tourism. Third, color in Memphis has never been an ideological vehicle. As with decoration it is born tilth the design, forming an integral part of the structure. It alters the objects molecules. It works as a mass, as an intrinsic feature of a certain form and volume. The Memphis fashion was realized the introduction of ultramodern science into such experimental and creative implementation as optical motive, brilliancy of colour of electronic medium in audition to metallic fabric and high technical synthetic fiber. A color tilth pop culture connotations that weaver between technological allusions and Mcdonald's.

  • PDF

Investigation of Natural Convective Heat Flow Characteristics of Heat Sink (히트싱크의 자연대류 열유동 특성 분석)

  • Jung, Tae Sung;Kang, Hwan Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.27-33
    • /
    • 2013
  • To ensure proper functioning of electrical and mechanical systems, cooling devices are of great importance. A heat sink is the most common cooling device used in many industries such as the semiconductor, electronic instrument, LED lighting, and automotive industries. To design an optimal heat sink, the required surface area for heat radiation should be calculated based on an accurate expectation of the heat flow rate in the target environment. In this study, the convective heat flow characteristics were numerically investigated for a vertically installed typical heat sink and a horizontally installed one in free convection using ANSYS CFX. Comparative experiments were carried out to reveal the quantitative effect of the installation direction on the cooling performance. Moreover, the result was analyzed using the dimensionless correlation with the Nusselt number and Rayleigh number and compared with well-known theories. Finally, it was observed that the cooling performance of the vertically installed heat sink is approximately 10~15% better than that of the one in natural convection.

Development of a Wearable Inertial Sensor-based Gait Analysis Device Using Machine Learning Algorithms -Validity of the Temporal Gait Parameter in Healthy Young Adults-

  • Seol, Pyong-Wha;Yoo, Heung-Jong;Choi, Yoon-Chul;Shin, Min-Yong;Choo, Kwang-Jae;Kim, Kyoung-Shin;Baek, Seung-Yoon;Lee, Yong-Woo;Song, Chang-Ho
    • PNF and Movement
    • /
    • v.18 no.2
    • /
    • pp.287-296
    • /
    • 2020
  • Purpose: The study aims were to develop a wearable inertial sensor-based gait analysis device that uses machine learning algorithms, and to validate this novel device using temporal gait parameters. Methods: Thirty-four healthy young participants (22 male, 12 female, aged 25.76 years) with no musculoskeletal disorders were asked to walk at three different speeds. As they walked, data were simultaneously collected by a motion capture system and inertial measurement units (Reseed®). The data were sent to a machine learning algorithm adapted to the wearable inertial sensor-based gait analysis device. The validity of the newly developed instrument was assessed by comparing it to data from the motion capture system. Results: At normal speeds, intra-class correlation coefficients (ICC) for the temporal gait parameters were excellent (ICC [2, 1], 0.99~0.99), and coefficient of variation (CV) error values were insignificant for all gait parameters (0.31~1.08%). At slow speeds, ICCs for the temporal gait parameters were excellent (ICC [2, 1], 0.98~0.99), and CV error values were very small for all gait parameters (0.33~1.24%). At the fastest speeds, ICCs for temporal gait parameters were excellent (ICC [2, 1], 0.86~0.99) but less impressive than for the other speeds. CV error values were small for all gait parameters (0.17~5.58%). Conclusion: These results confirm that both the wearable inertial sensor-based gait analysis device and the machine learning algorithms have strong concurrent validity for temporal variables. On that basis, this novel wearable device is likely to prove useful for establishing temporal gait parameters while assessing gait.

Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture (손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스)

  • Jang, Ik-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.

Principle and Applications of EELS Spectroscopy in Material Characterizations (재료 분석에서 전자 에너지 손실 스펙트럼 (EELS)의 원리 및 응용 연구)

  • Yoon, Sang-Won;Kim, Kyou-Hyun;Ahn, Jae-Pyoung;Park, Jong-Ku
    • Journal of Powder Materials
    • /
    • v.14 no.3 s.62
    • /
    • pp.157-164
    • /
    • 2007
  • An electron energy loss spectroscopy (EELS) instrument attached on transmission electron microscopy (TEM) becomes a powerful and analytical tool for extracting the noble information of materials using the enhancement of TEM images, elemental analysis, elemental or chemical mapping images, electron energy loss near edge structure (ELNES), and extended energy-loss fine structure (EXELFS). In this review, the principle and applications of EELS which is widely used in material, life, and electronic sciences were introduced.

An experimental study on the reproducibility and the position of centric relation and Myocentric (중심위와 Myocentric의 재현성 및 상호위치에 관한 연구)

  • Lee, Jong-Yeab;Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.24 no.1
    • /
    • pp.45-54
    • /
    • 1986
  • The establishment and/or registration of an optimal or physiologic relationship between the maxillae and mandible has long been a subject of considerable interest and controversy in dentistry. Centric relation has been generally accepted as a repeatable starting point for restoring the mouth. Recently, it has been claimed that an electronic device (Myo-Monitor) will produce an accurate, reproducible occlusal registration at the vertical and horizontal occlusal position most compatible with the muscular of each patient. The objectives of this study was to compare Myo-Monitor centric to centric relation at the points of reproducibility and anteroposterior, superoinferior position. A Vericheck instrument was employed for examining difference in the position and reproducibility of mandible reproduced by the various check bite records. For this study, 8 dental students and dentists who had no missing teeth and no difficulties of mandibular movement were selected. The following three different positions of the mandible were registered (a) centric relation manipulated by means of chin-point technique with Lucia-jig, (b) centric relation manipulated by means of bilateral technique, (c) Myocentric manipulated by Myo-Monitor. From this experiment, the following results were obtained. 1. Bilateral manipulated centric relation was more reproducible than Myocentric in anteroposterior and superoinferior position , but more reproducible than centric relation manipulated by means of chin point technique with Lucia-jig in anteroposoterior position. Centric relation manipulated by means of chin Point technique with Lucia-jig was more reproducible than Myocentric in right anteroposterior and superoinferior position. 2. Centric relation by means of chin point technique with Lucia-jig was posterior($2.16{\pm}0.78mm$) and superior($0.41{\pm}0.16mm$) to centric occlusion. Bilateral manipulated centric relation was posterior($1.68{\pm}0.10mm$) and superior($1.02{\pm}0.45mm$) to centric occlusion. Myocentric was anterior($0.75{\pm}0.70mm$), inferior($0.59{\pm}0.44mm$) to centric occlusion.

  • PDF