• Title/Summary/Keyword: Electronic indicator

Search Result 145, Processing Time 0.024 seconds

Indicator-free DNA Chip Array Using an Electrochemical System

  • Park, Yong-Sung;Kwon, Young-Soo;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.4
    • /
    • pp.133-136
    • /
    • 2004
  • This research aims to develop a DNA chip array without an indicator. We fabricated a microelectrode array through photolithography technology. Several DNA probes were immobilized on an electrode. Then, target DNA was hybridized and measured electrochemically. Cyclic-voltammograms (CVs) showed a difference between the DNA probe and mismatched DNA in an anodic peak. This indicator-free DNA chip resulted in a sequence-specific detection of the target DNA.

HC-06 Bluetooth based driver module for emergency LED Multi-Directional Indicator

  • Jung, Joonseok;Kwon, Jongman;Mfitumukiza, Joseph;Jung, Soonho;Lee, Minwoo;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.1
    • /
    • pp.114-119
    • /
    • 2017
  • In this paper we present the search on HC-06 Bluetooth based driver module for emergency LED Multi-Directional Indicator. Nowadays, a growing trends in which electronic displays such as LED, LCD or plasma monitors are being installed in public places like bars, stores, entertainment areas, restaurants, lobbies, etc. In this paper, the study is curried out on efficiency of HC-06 Bluetooth module based controller driver that relates generally to the field of emergency signage management systems for displaying various indicator contents remotely on electronic displays in public and privates venues. It allows user smart devices interaction remotely with digital signage by providing content for displaying on at least one display in a venue. Depending on the emergency case, HC-06 Bluetooth based driver module proves the high efficiency as well as good performance of processing and communicating remotely the indicator based message that is displayed from a venue management control system by using smart devices. The system combines smart device that linked to HC-06 Bluetooth module with ATmega168/328 embedded micro controller which result by switching the displayer containing the digital signage indicator based message.

A Study on the development of wheels' direction indicator (자동차 바퀴 방향 지시기 개발에 관한 연구)

  • Cho, Chong-Duck;Shin, Seung-Sik
    • 전자공학회논문지 IE
    • /
    • v.43 no.4
    • /
    • pp.76-82
    • /
    • 2006
  • Wheels' Direction Indicator, an electronic direction displaying system, provides a driver with information of wheels' direction in real time. The purpose of this study is to develop the system showing on LCD and LED with measuring steering wheel's movement. This system that applies a steering wheel's movement to the data process part will reduce inconvenience that confirms wheels' direction before throughout the open window before driving a car in parking lot.

An Improved Algorithm of Fault Indicator Generation of FRTU in Distribution Automation System (배전자동화시스템에서 전류방향성을 이용한 단말장치의 고장표시 오류 개선 방법)

  • Seo, Jung-Soo;Kim, Hyung-Seung;Lim, Seong-Il;Choi, Myeon-Song;Lee, Seung-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1354-1363
    • /
    • 2014
  • In this paper, an improved method of fault indicator generation algorithm in FRTUs is proposed for the present Distribution Automation System. In order to find fault area, correct FI information should be generated. But when a single line-to-ground fault occurs, FI information is generated in downside of the fault in some circumstance because existing FI algorithm considers only magnitude. It is found that the upside fault current direction if different from the downside fault current direction. Therefore, in order to prevent to generate the wrong fault indication information for FRTU at the downside of the fault, an improved fault indication generation method is developed. Not only the basic conditions are taken into account, but also the directions from the angle difference between zero and positive sequence currents are considered to generated the fault indication information. In case study, the proposed method has been testified and shown the reasonability in generating correct the fault indication information, for many kinds of faults according to conditions.

A Study on the Precision Engine Indicatior(I) (Zero-shift Compensation of the Engine Indicator with a Electronic Device) (고정도 엔진 지압계에 관한 연구 (1) <온도 특성에 의한 영점이동의 보상>)

  • 박상길;문덕홍;안수길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.34-39
    • /
    • 1983
  • Development of modern internal combustion engine requires more precise indicator. In the case of strain gage-strain tube type indicator, thermal expansion of the indicator's fixed part makes zero-shift in spite of water cooling. Therefore, the authors analyzed the cause of zero-shift phenomenon on strain gage-strain tube type indicator and proposed a new device to compensate the zero-shift of indicator by electrical method without detoriorating the dynamic charcteristic. As the results, we found that the zero-shift is varied linearlly according to temperature variation of the indicator's fixed part and appling a new device, we can improve the zero-shift of indicator about 0.63% (0.63 kg/$cm^2$) of full scale, though we got 10% of it without the device at the cylinder head operating temperature (c.a. $200^{\circ}C$).

  • PDF

Development of Automatic Reading System for Steam Sterilization Indicator (스팀 멸균지시제 자동판독시스템 개발)

  • Song, Hyeok;Kim, Jeong-Rae;Lee, Woo-Cheol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.709-714
    • /
    • 2022
  • The color change of the success of the steam sterilization indicator used in steam sterilization is currently being read by relying on the human eye. The result of color change on the success of sterilization can only be accurately read and judged by trained personnel. Developed an automatic reading system for steam sterilization indicators for the current human-dependent system, and developed an automatic reading device system for reading methods that were previously relied on with the human eye to develop a system that is more accurate and easier for anyone to read.

SNP (Single Nucleotide Polymorphism) Detection Using Indicator-free DNA (비수식화 DNA를 이용한 SNP의 검출)

  • Choi, Yong-Sung;Park, Dae-Hee;Kwon, Young-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.224-226
    • /
    • 2003
  • In this paper, we succeeded SNP discrimination of DNA hybridization on microarray using new electrochemical system. Using the electrochemical method with a label-free DNA has Performed DNA chip microarray. This method is based on redox of an electrochemical ligand. We developed scanning system with high performance.

  • PDF

Interturn Fault Diagnosis in Interior Permanent Magnet Synchronous Motors Using Negative-Sequence Impedance (역상 임피던스를 이용한 매립형 영구자석 동기전동기의 권선간 고장진단)

  • Jeong, Hyeyun;Kim, Sang Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.394-401
    • /
    • 2017
  • Fault diagnosis is important due to the increasing demand of using interior permanent magnet synchronous machines (IPMSMs). In particular, an interturn fault is one of the most frequent electrical faults in IPMSMs. This paper proposes a fault indicator for diagnosis of interturn faults in IPMSMs. The fault indicator is developed by negative-sequence impedance. The effectiveness of the fault indicator to diagnose interturn faults was verified through various fault conditions.

Intelligent Diagnosis System for an Electronic Weighting Machine (전자 저울을 위한 지능형 고장 진단 시스템)

  • 김종원;김영구;조현찬;서화일;김두용;이병수
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2001.12a
    • /
    • pp.78-82
    • /
    • 2001
  • Electronic Weighting Machine is used an electronic scale which has many trouble because of broken load cells. In this paper, we propose an intelligent Diagnosis System will for an electronic weighting machine using fuzzy logic. It's purpose be detect of the load cell's trouble. The electronic circuit of system, which call 'junction box', will be connected resistances in a series at circuit of Wheatstone Bridge for monitoring the condition of load cells.