• 제목/요약/키워드: Electronic Valve

검색결과 277건 처리시간 0.034초

전자비례감압밸브를 이용한 가변용량형 유압펌프의 다기능 제어 (Multi-function Control of Hydraulic Variable Displacement Pump with EPPR Valve)

  • 정동수;김형의;강이석
    • 한국자동차공학회논문집
    • /
    • 제14권6호
    • /
    • pp.160-170
    • /
    • 2006
  • If hydraulic pump controlled by mechanical type regulator has more than one control function, the construction of regulator will be very complicated and control performance falls drastically. It is difficult to have more than one control function for hydraulic pump controlled by electronic type hydraulic valve due to the inconsistency of controllers. This paper proposes a multi-function control technique which controls continuously flow, pressure and power by using EPPR(Electronic Proportional Pressure Reducing) valve in swash plate type axial piston pump. Nonlinear mathematical model is developed from the continuity equation for the pressurized control volume and the torque balance for the swash plate motion. To simplify the model we make the linear state equation by differentiating the nonlinear model. A reaction spring is installed in servo cylinder to secure the stability of the control system. We analyze the stability and disturbance by using the state variable model. Finally, we review the control performances of flow, pressure and power by tests using PID controller.

Free Floating 구조를 갖는 마이크로 밸브의 제작 (A Fabrication of the Micro Valve with Free Floating Structure)

  • 손미영;문병필;전호승;한진우;김철주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.136-139
    • /
    • 2002
  • Previous valves have initial gap problem, high voltage or high pressure problem. In this paper, various micro valves with free floating structure have been fabricated and tested to solve the initial gap and high pressure problems. The paper presents how to etch Parylene-C which is a valve cap material without A1 mask layer. The maximum flow-rate of fabricated micro valve is$118{\mu\ell}$/min with $370{\mu}m$ orifice size and the leakage at the initial and reverse pressure is not observed.

  • PDF

스월 제어 밸브를 적용한 직접분사식 가솔린 엔진의 희박연소 특성 (Lean burn Combustion Characteristics of Direct Injection Gasoline Engine with Swirl Control Valve)

  • 이민호;문학훈;차경옥
    • 한국분무공학회지
    • /
    • 제9권2호
    • /
    • pp.9-17
    • /
    • 2004
  • The performance characteristics of lean burn system in gasoline engine are mainly affected by the air-fuel mixture in cylinder, gas exchange process of manifold system, exhaust emission of engine, and the electronic engine control system. In order to obtain the effect of performance factors on the optimum conditions of lean burn engine, this study deal with the behavior of mixture formation, gas flow characteristics of air, flow and evaporation analysis of spray droplet in cylinder, vaporization and burning characteristics of lean mixture in the engine, and the control performance of electronic engine control system. The optimum flow conditions were investigated with the swirl and tumble flows in the combustion chamber with swirl control valve. The performance characteristics and optimum condition of flow field in intake system were analyzed by the investigation of inlet flow of air and combustion stabilization on cylinder.

  • PDF

항공기 외장형 정찰 장비용 냉각 시스템의 성능 특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of Cooling System for Aircraft External Reconnaissance Stores)

  • 정대윤;이행복
    • 한국군사과학기술학회지
    • /
    • 제16권1호
    • /
    • pp.74-80
    • /
    • 2013
  • In this paper, we have proposed a vapor cycle refrigeration system as a cooling system to provide cooling air to the aircraft external reconnaissance stores. In the proposed vapor cycle system, receiver which prevents refrigerant from subcooling was eliminated and thermal expansion valve was replaced with electronic expansion valve. The vapor cycle refrigeration system is aimed to provide cooling air to the reconnaissance stores which is added to the aircraft in the form of external store. The wide temperature range of ambient air from the flight conditions can decrease the cooling performance and can make the refrigeration system unstable in low ambient temperature. Performance characteristics of the vapor cycle refrigeration system has been experimented under air conditions which is derived from the flight envelope. From the experiments, the vapor cycle refrigeration system has been proved to provide enough cooling air to the reconnaissance equipment and to be stable under all the flight conditions.

무공해 자동차용 수열원 히트펌프 시스템의 난방 성능에 관한 실험적 연구 (An Experimental Study on the Heating Performance of Coolant Heat Source Heat Pump System for Zero Emission Vehicles)

  • 이대웅
    • 한국자동차공학회논문집
    • /
    • 제22권7호
    • /
    • pp.57-62
    • /
    • 2014
  • This study presented the feasibility of a coolant heat-source heat pump system as an alternative heating system for electrically driven vehicles. Heat pumps are among the most environmentally friendly and efficient heating technologies in residential buildings. In various countries, electric mobiles devices such as EV, PHEV, and FCEV, have been mainly concerned with heat pumps for new mobile markets. The experiments herein were conducted for various ambient temperatures and coolant temperatures to reflect the winter season. The system, a coolant heat-source heat pump, consisted of an inside heat exchanger, an outside heat exchanger, a motor driven compressor, an electronic expansion valve, and plumbing parts. For the experimental results, the maximum heating capacity and air discharge temperature are up to 6.3 kW and $62^{\circ}C$ respectively at an ambient temperature of $10^{\circ}C$, and coolant at $10^{\circ}C$. However, at $-20^{\circ}C$ ambient temperature and $-10^{\circ}C$ coolant temperature, conditions were insufficient to warm the cabin as the air discharge temperature was $13^{\circ}C$.

반복 최소 자승법을 이용한 전자식 스로틀 바디의 PID 이득 자동 조정 (PID Gain Auto Tuning of ETB by Using RLS)

  • 전찬성;김대상;이장명
    • 로봇학회논문지
    • /
    • 제2권1호
    • /
    • pp.1-8
    • /
    • 2007
  • This paper presents a PID automatic gain-tuning algorithm for the electronic throttle valve which is driven by wire. Since the system characteristics of position control for electronic throttle valve are so complicated that both the real time robustness and the manufacturing cost must be considered for mass production. To resolve this paradox, a kind of algorithm called RLS (Recursive Least Square) is adopted for the control of the ETB (Electronic Throttle Body). Using this algorithm, the PID gains can be adjusted automatically with the estimated system parameters. Furthermore, a pre-filter is supplemented for the sake of the robustness against the friction and loads. From the industrial requests for the system, the design specifications are decided as follows: the settling time should be less than 1sec and the overshoot should be kept below 3%. The results of the experiments based on this approach show that the high robustness can be achieved while the system stability is satisfied steadily. A parameter estimation scheme and a gain-tuning algorithm have been properly combined and utilized in this research and the effectiveness is verified through the real experiments.

  • PDF

제동 시스템을 위한 고주파수 ECU의 제어 특성 연구 (Study on the Characteristics of Control by High Frequency ECU for Braking System)

  • 연규봉;정정화
    • 한국산학기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.2428-2434
    • /
    • 2012
  • 본 논문은 제동 시스템에서 전자식 주행안정 제어장치(ESC)의 유압 모듈레이터의 솔레노이드 밸브 제어에 대한 것이다. ESC의 전자제어유니트(ECU)를 제어하기 위한 방법으로 고주파수 제어와 슬로프 제어를 적용하였으며, 서지 압력 및 전자파간섭(EMI) 저감 특성을 연구하였다. 고주파수에서의 전자파 방출을 줄이기 위하여 ECU 출력 단에 슬로프 제어 기능을 추가하였다. 측정결과 제동 시스템에서 고주파수 ECU의 솔레노이드 밸브제어 방법에 따라 서지 압력과 전자파 방출이 저감될 수 있음을 확인하였다. 결론적으로 고주파수 ECU 제어 연구 결과에 의해 제동 시스템 성능을 향상방안을 제시하고자 한다.

MoN 하지층을 이용한 스핀밸브의 자기저항 특성 (Magnetoresistance Properties of Spin Valves Using MoN Underlayer)

  • 김지원;조순철;김상윤;고훈;이창우
    • 한국자기학회지
    • /
    • 제16권5호
    • /
    • pp.240-244
    • /
    • 2006
  • 본 연구에서는 하지층으로 사용한 Mo(MoN)의 두께 변화에 따른 스핀밸브 구조의 자기적 특성과 열처리 결과를 비교 검토하였다. 사용된 스핀밸브는 Si기판/$SiO_2/Mo(MoN)(t{\AA})/NiFe(21\;{\AA})/CoFe(28\;{\AA})/Cu(22\;{\AA})/CoFe(18\;{\AA})/IrMn(65\;{\AA})/Ta(25\;{\AA})$ 구조이다. 또한 본 연구에서는 MoN 하지층을 Si기판에 증착하여 열처리후 특성을 분석하였다. MoN 박막의 질소량이 증가(5 sccm까지)할수록 비저항은 증가하였다. $600^{\circ}C$에서 열처리 후 측정한 XRD 결과를 보면 Si/Mo(MoN) 박막에서 규소화합물을 발견할 수 없었다. MoN을 하지층으로 사용할 경우 $300^{\circ}C$에서 열처리 후 측정한 XPS 결과를 보면 질소 유입량이 5 sccm인 경우가 질소 유입량이 1 sccm인 경우보다 안정적임을 알았다. Mo(MoN) 하지층을 사용한 경우 하지층 두께 변화($45{\AA}$)에 따라 자기저항비와 교환결합력의 변화는 소폭이었다. Mo 하지층의 열처리 온도별 자기저항비는 열처리 전 상온에서 7.0%이었고, $220^{\circ}C$ 열처리 때 7.5%로 증가하였다. 이후 열처리 온도를 $300^{\circ}C$까지 증가 시키면 자기저항비는 7.5%에서 3.5%로 감소하였고, 질소유입량이 변화(5 sccm까지)하여도 유사한 경향을 보였다.

NiO/NiFe/Cu/NiFe 스핀-밸브 샌드위치의 자기저항 특성 (Magneto resistance in NiO/NiFe/Cu/NiFe spin-valve Sandwiches)

  • 김재욱
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권10호
    • /
    • pp.1016-1021
    • /
    • 1997
  • Magneto resistance properties in spin-valve sandwiches with various thickness of nanmagnetic layer in contact with the ferromagnetic NiFe film were investigated. The NiFe layer in contact with the NiO film was pinned by strongly exchange-biased coupling and the free NiFe layer at the film surface induced a sharp change in the magnetoresistance at -5~15Oe due to small coercivity. The NiO/NiFe/Cu/NiFe film showed a magnetoresistance ratio in the range of 2.3~2.9% and a field sensitivity above 2.2%/Oe with various of nonmagnetic layer. The NiO/NiFe/Cu/NiFe film of the field sensitivity above 2.2%/Oe suggests stang possibility of magnetic sensor matter.

  • PDF

내부열교환기 및 전자팽창장치를 적용한 가변속 이산화탄소 사이클의 냉방성능에 관한 실험적 연구 (Experimental Study on the Cooling Performance of a Variable Speed $CO_2$ Cycle with Internal Heat Exchanger and Electronic Expansion Valve)

  • 조홍현;류창기;김용찬
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.209-215
    • /
    • 2005
  • Since a transcritical $CO_2$ cycle shows lower performance than conventional air conditioners in the cooling mode operation, it is required to enhance the performance of the $CO_2$ cycle by applying advanced technologies and optimizing components. In this study, the cooling performance of a $CO_2$ system measured by varying refrigerant charge amount, compressor frequency, EEV opening and length of internal heat exchanger. As a result, the cooling COP of the basic system without internal heat exchanger was 2.1. The cooling performance of the modified cycle applying internal heat exchanger improved by $4-9\%$ over the basic cycle.