Experimental Study on the Cooling Performance of a Variable Speed $CO_2$ Cycle with Internal Heat Exchanger and Electronic Expansion Valve  

Cho Honghyun (Graduate School of Mechanical Engineering, Korea University)
Ryu Changgi (Graduate School of Mechanical Engineering, Korea University)
Kim Yongchan (Department of Mechanical Engineering, Korea University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.17, no.3, 2005 , pp. 209-215 More about this Journal
Abstract
Since a transcritical $CO_2$ cycle shows lower performance than conventional air conditioners in the cooling mode operation, it is required to enhance the performance of the $CO_2$ cycle by applying advanced technologies and optimizing components. In this study, the cooling performance of a $CO_2$ system measured by varying refrigerant charge amount, compressor frequency, EEV opening and length of internal heat exchanger. As a result, the cooling COP of the basic system without internal heat exchanger was 2.1. The cooling performance of the modified cycle applying internal heat exchanger improved by $4-9\%$ over the basic cycle.
Keywords
Carbon dioxide; Transcritical cycle; Internal heat exchanger(IHX); Electronic expansion valve(EEV);
Citations & Related Records
연도 인용수 순위
  • Reference
1 Hrnjak, P., Richeter, M., Song, S., Kim, M., Bullard, C., 2000, Transcritical $CO_2$ heat pump for residential application, 4th IIR-Gustav Lorentzen Conference, pp. 9-16   DOI   ScienceOn
2 Hafner, A., 2000, Experimental study on heat pump operation of prototype $CO_2$ mobile air conditioning system, 4th IIR-Gustav Lorentzen Conference, pp. 177-184
3 ASHRAE, 1983, Methods of testing for seasonal efficiency of unitary air-conditioner and heat pumps, ASHRAE Standard 116
4 Halozan, H., Rieberer, R., 2000, $CO_2$ as refrigerant-possible applications, 4th IIR-Gustav Lorentzen Conference, pp. 43-50
5 Hwang, Y., Celik, A., Radermacher, R., 2004, Performance of $CO_2$ cycle with a two-stage compressor, Int. Refrigeration and Air Conditioning Conference at Purdue, R105
6 Kim, S., 2002, Study on performance of heat pump for hot water heater and autocascade cycle using $CO_2$, Ph.D. Thesis. Seoul National University, Seoul, KOREA
7 Neksa, P., Rekstad, H., Zakeri, R., Schiefloe, P., 1998, $CO_2$ heat pump water heater: characteristics, system design and experimental results, Int. Journal of Refrigeration, Vol. 21, No. 3. pp. 172-179   DOI   ScienceOn
8 Neksa, P., 2002, $CO_2$ heat pump systems, Int. Journal of Refrigeration, Vol. 25, pp. 421-427   DOI   ScienceOn
9 Hwang, Y., Huff, H., Preissner, R., Radermacher, R., 2001, $CO_2$ transcritical cycles for high temperature application, Proceedings of 2001 ASME Int. Mechanical Engineering Congress in New York, IMECE2001/AES- 23630
10 Hwang, Y., Radermacher, R., 1999, Experimental investigation of the $CO_2$ refrigeration cycle, ASHRAE Transactions, Vol. 105, Pt. 1, pp. 1219-1227