• 제목/요약/키워드: Electronic Nose

검색결과 287건 처리시간 0.03초

MPEG-V(ISO/IEC 23005) 표준적용이 가능한 전자코 시스템 구현 (Implementation of Electronic Nose System applicable to MPEG-V(ISO/IEC 23005) Standardization)

  • 임해진;최장식;전진영;변형기
    • 센서학회지
    • /
    • 제25권6호
    • /
    • pp.388-393
    • /
    • 2016
  • MPEG-V(ISO/IEC 23005) standardizes normative sensory effects metadata and sensory devices command for adapting the sensory effects between the virtual world and the real world. MPEG-V(Virtual) standardization has been carried out by 3DG(Dimensional Graphics) ad-hoc group inside MPEG Working Group(ISO IEC JTC1/SC29/WG11). For the scent effect, one of the sensory effects within MPEG-V, we proposed an olfactory interaction model including electronic nose and scent display to the ad-hoc group. Recently, we proposed types and elements related to the electronic nose as a sensor defined in MPEG-V standard for olfactory interaction. At the 114th MPEG meeting, the types and elements were consequently reflected on MPEG-V CD(Committee Draft) 4th edition. In this paper, we implement an electronic nose system applicable to MPEG-V standard by using MPEG-V schema, encoder, and decoder in order to assess their adequacy.

Sensor array optimization techniques for exhaled breath analysis to discriminate diabetics using an electronic nose

  • Jeon, Jin-Young;Choi, Jang-Sik;Yu, Joon-Boo;Lee, Hae-Ryong;Jang, Byoung Kuk;Byun, Hyung-Gi
    • ETRI Journal
    • /
    • 제40권6호
    • /
    • pp.802-812
    • /
    • 2018
  • Disease discrimination using an electronic nose is achieved by measuring the presence of a specific gas contained in the exhaled breath of patients. Many studies have reported the presence of acetone in the breath of diabetic patients. These studies suggest that acetone can be used as a biomarker of diabetes, enabling diagnoses to be made by measuring acetone levels in exhaled breath. In this study, we perform a chemical sensor array optimization to improve the performance of an electronic nose system using Wilks' lambda, sensor selection based on a principal component (B4), and a stepwise elimination (SE) technique to detect the presence of acetone gas in human breath. By applying five different temperatures to four sensors fabricated from different synthetic materials, a total of 20 sensing combinations are created, and three sensing combinations are selected for the sensor array using optimization techniques. The measurements and analyses of the exhaled breath using the electronic nose system together with the optimized sensor array show that diabetic patients and control groups can be easily differentiated. The results are confirmed using principal component analysis (PCA).

전자 코를 이용한 한우 등심육의 냉장저장 중 향기 패턴 분석 (Aroma Pattern Analysis of Hanwoo Beef (M. longissimus) using Electronic Nose during Refrigerated Storage)

  • 이성기;김주용;김용선
    • 한국축산식품학회지
    • /
    • 제24권3호
    • /
    • pp.260-265
    • /
    • 2004
  • 본 연구는 전자 코 시스템을 이용하여 센서의 감응도, 주성분 분석, 판별분석을 통해 한우육의 향기 패턴을 구명하고, 이를 pH 및 TBARS 값과 비교함으로써 쇠고기의 신속한 향기 평가방법의 가능성을 모색하기 위해 실시하였다. 시료는 도축 후 24시간이 경과한 쇠고기의 등심을 5$\pm$1$^{\circ}C$에서 7일간 저장하면서 실험에 사용하였다. 저장기간이 증가함에 따라 SY/G, SY/AA, SY/Gh, SY/gCTl, SY/gCT 센서의 감응도(dR/R0) 값은 감소하였으나, SY/LG, T30/1, P10/1, P10/2, P40/1, T70/2, PA2 센서의 dR/R0 값은 증가하였다. 저장 1일과 3일째에서는 dR/R0 값이 SY/AA#, T70/2 센서에서만 유의적인 차이를 보였으나(p<0.05), 저장 7일째에서 저장1일과 비교하였을 때 12개의 센서가 모두 유의적인 차이를 보였다(p<0.05). 감응도의 결과를 주성분 분석으로 mapping 하였을 때 저장 1일에 오른쪽 중간, 3일에 오른쪽 하단, 7일에 왼쪽에 길게 퍼져 군락이 형성되었다. 다시 판별분석으로 mapping을 하면 동일 저장기간내 군락이 집중되고, 저장기간별 군락군이 분산되어 뚜렷하게 구별되었다. 저장기간동안 육의 pH와 TBARS는 모두 어떤 항목과도 상관성을 보이지 않았으나, 모든 센서의 값이 각각 정 또는 역의 높은상관성을 가지고 있었다(p<0.001).

전자코 시스템을 위한 IEEE 1451.4 TEDS의 새로운 표준화 방안 (The New Way to Standardize IEEE 1451.4 TEDS for Electronic Nose System)

  • 김정도;김동진;정영창;정우석;변형기
    • 전자공학회논문지SC
    • /
    • 제43권1호
    • /
    • pp.21-30
    • /
    • 2006
  • IEEE 1451.4는 센서 및 액츄에이터를 위한 스마트트랜스듀서의 연결 표준안으로 정의되었다. 이 표준은 아날로그 트랜스듀서의 정보를 디지털 형태로 전송한다 이 디지털 형태의 정보를 TEDS(transducer electronic data sheet)라고 부른다. IEEE 1451.4 TEDS는 전자코 시스템에서의 어레이 센서에 대해서는 이용하기가 어렵다. 본 논문은 전자코 시스템에서 센서 인터페이스의 대한 표준화에 대해 분석해보고 새로운 방안을 제안한다.

개인 휴대 단말기 (PDA)를 기반으로 한 휴대용 E-Nose의 개발 (A portable electronic nose (E-Nose) system using PDA device)

  • 양윤석;김용신;하승철;김용준;조성목;표현봉;최창억
    • 센서학회지
    • /
    • 제14권2호
    • /
    • pp.69-77
    • /
    • 2005
  • The electronic nose (e-nose) has been used in food industry and quality controls in plastic packaging. Recently it finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. Moreover, the use of portable e-nose enables the on-site measurements and analysis of vapors without extra gas-sampling units. This is expected to widen the application of the e-nose in various fields including point-of-care-test or e-health. In this study, a PDA-based portable e-nose was developed using micro-machined gas sensor array and miniaturized electronic interfaces. The rich capacities of the PDA in its computing power and various interfaces are expected to provide the rapid and application specific development of the diagnostic devices, and easy connection to other facilities through information technology (IT) infra. For performance verification of the developed portable e-nose system, Six different vapors were measured using the system. Seven different carbon-black polymer composites were used for the sensor array. The results showed the reproducibility of the measured data and the distinguishable patterns between the vapor species. Additionally, the application of two typical pattern recognition algorithms verified the possibility of the automatic vapor recognition from the portable measurements. These validated the portable e-nose based on PDA developed in this study.

Post-processing Technique for Improving the Odor-identification Performance based on E-Nose System

  • Byun, Hyung-Gi
    • 센서학회지
    • /
    • 제24권6호
    • /
    • pp.368-372
    • /
    • 2015
  • In this paper, we proposed a post-processing technique for improving classification performance of electronic nose (E-Nose) system which may be occurred drift signals from sensor array. An adaptive radial basis function network using stochastic gradient (SG) and singular value decomposition (SVD) is applied to process signals from sensor array. Due to drift from sensor's aging and poisoning problems, the final classification results may be showed bias and fluctuations. The predicted classification results with drift are quantized to determine which identification level each class is on. To mitigate sharp fluctuations moving-averaging (MA) technique is applied to quantized identification results. Finally, quantization and some edge correction process are used to decide levels of the fluctuation-smoothed identification results. The proposed technique has been indicated that E-Nose system was shown correct odor identification results even if drift occurred in sensor array. It has been confirmed throughout the experimental works. The enhancements have produced a very robust odor identification capability which can compensate for decision errors induced from drift effects with sensor array in electronic nose system.

Comparative Investigation of Flavors in Cigarettes by Electronic Nose and GC/MS

  • Lee, Yelin;Park, Jin-Won;Lee, Hwan-Woo;Lee, Seung-Yong;Lee, Hyung-Suk
    • 한국연초학회지
    • /
    • 제35권1호
    • /
    • pp.20-27
    • /
    • 2013
  • An Electronic Nose(E-Nose) and Gas Chromatography/Mass Spectroscopy (GC/MS) are meanwhile conventional technique to analyze volatile materials in many industries (e.g., food, medicine, environment) and have broad acceptance in the analysis of tobacco products. In this study, an experiment where tin oxide gas sensor array responses and GC/MS profiles are used to characterize the volatile compounds of different cigarettes at the same time is performed and the measurements of two instruments are compared for cigarette samples with a known chemical information. E-Nose and GC/MS were employed to differentiate and match flavored cigarettes with commercial tobacco flavoring agents (lavender, vanilla, peppermint, orange, star anise). For verifying reliability of two systems, the analyses were conducted in terms of amount of flavors in each cigarettes using partial least squares (PLS) and with the principal components analysis (PCA). Various chemical sensors and GC/MS data was reduced into two principal factors (PC1, PC2) for being distinguished with visualized regions. Both systems provided adequate results for odor characteristics of cigarettes in this study with each instrument having its own advantages and disadvantages.

전자코를 이용한 검정현미의 산지판별 (Application of Electronic Nose in Discrimination of the Habitat for Black Rice)

  • 조연수;한기영;김정호;김수정;노봉수
    • 한국식품과학회지
    • /
    • 제34권1호
    • /
    • pp.136-139
    • /
    • 2002
  • 검정현미에 내포한 특이한 향기성분을 토대로 수입산 또는 국내산인지의 여부를 전자코로 분석하였다. 주성분 분석 결과 전반적으로 수입산과 국내산의 판별이 뚜렷하게 구별 가능하였다. 또한 인공신경망 분석 프로그램을 이용하여 학습시켜 원산지를 모르는 시료를 분석한 결과 국내산 검정현미가 수입산인지 국내산인지를 구별할 수 있었다. E-Nose 5000을 이용한 결과는 69종의 국내산 검정현미를 국내산으로 판별한 경우가 64종으로 92.75%이었고, 13종의 수입산 검정현미를 수입산으로 판별한 경우는 11종으로 92.31%의 높을 확률로 metal oxide sensor로만 구성된 전자코의 판별정도보다 더 정확하게 구별할 수 있었다.

식품산업 분야에서의 2세대 전자코의 응용과 활용가능성 (Application of the second generation of electronic nose and its useful possibility in food industry)

  • 이수진;노봉수
    • 식품과학과 산업
    • /
    • 제50권4호
    • /
    • pp.50-64
    • /
    • 2017
  • Applications of the second generation of electronic nose in various field such as new food product development, slight rancidity during induction period, classification of similar products, discovery of odor, and odor reduction were reviewed. The possibilities of using electronic noses in areas that are difficult to analyze so far would be done in the future. It is believed that the utility value is expanded not only in the food industry but also in other areas.

재가열 튀김유의 이화학적 특성과 전자코에 의한 향기 패턴 분석 (Physiochemical Properties of Repeated Deep-frying Oil and Odor Pattern Analysis by Electronic Nose System)

  • 김남숙;신정아;이기택
    • 동아시아식생활학회지
    • /
    • 제16권6호
    • /
    • pp.717-723
    • /
    • 2006
  • Chemical characteristics of soybean oil after deep-frying with potato sticks (200 g, 10% w/w of soybean oil) were studied according to the 34 deep-frying times. After consecutive 34 deep-frying, total polyunsaturated FA contents was gradually decreased while the total saturated FA and trans FA were increased. Acid value and peroxide value were increased while iodine value decreased, respectively. The Hunter $L^{\ast}$ value decreased while each $a^{\ast}\;and \;b^{\ast}b$ value were gradually increased. Electronic nose equipped with 12 metal oxide sensors was used for the discrimination of odor pattern of frying oils against the times of deep-trying. The proportions of 1st and 2nd principal component analysis showed 75.97% and 21.23%, respectively. While 6 among total 12 sensors well responded to discrimination of odor in the repented frying oils, suggesting that the odor pattern of each oil after deep-frying would be discriminated against fresh soybean oil, especially after 14 times. From the results, electronic nose could differentiate the degree of quality deterioration of the repeated deep-frying oils.

  • PDF