• Title/Summary/Keyword: Electronic Journal

Search Result 34,284, Processing Time 0.068 seconds

Standardization of Identification-number for Processed Food in Food-traceability-system (가공식품에 대한 이력추적관리번호 부여체계의 표준화 방안)

  • Choi, Joon-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.2
    • /
    • pp.194-201
    • /
    • 2012
  • Facing a number of global food-related accidents, the concept and system for food traceability have been designed and introduced in many countries to manage the food-safety risks. To connect and harmonize the various food traceability-information in food traceability system according to the food supply chain, the coding system of identification-number for food-traceability has to be standardized. The GTIN (Global Trade Item Number) barcode system which has been globally standardized and implemented, is reviewed with the mandatory food-labeling regulation in expiration date of processed foods. The integration of GTIN-13 bar-code system for food-traceability is a crucial factor to expand its function in the food-related industrial areas. In this literature, the standard coding system of identification-number for food-traceability is proposed with 20 digit coding number which is combined with GTIN-13 bar-code (13 digit), expiration date (6 digit), and additional classification code (1 digit). This proposed standard coding system for identification-number has a several advantages in application for prohibiting the sale of hazard goods, food-recall, and inquiring food traceability-information. And also, this proposed coding system could enhance the food traceability system by communicating and harmonizing the information with the national network such as UNI-PASS and electronic Tax-invoice system. For the global application, the identification-number for food-traceability needs to be cooperated with the upcoming global standards such as GTIN-128 bar-code and GS1 DataBar.

DEVELOPMENT OF A LYMAN-α IMAGING SOLAR TELESCOPE FOR THE SATELLITE (인공위성 탑재용 자외선 태양카메라(LIST) 개발)

  • Jang, M.;Oh, H.S.;Rim, C.S.;Park, J.S.;Kim, J.S.;Son, D.;Lee, H.S.;Kim, S.J.;Lee, D.H.;Kim, S.S.;Kim, K.H.
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.3
    • /
    • pp.329-352
    • /
    • 2005
  • Long term observations of full-disk Lyman-o irradiance have been made by the instruments on various satellites. In addition, several sounding rockets dating back to the 1950s and up through the present have measured the $Lyman-{\alpha}$ irradiance. Previous full disk $Lyman-{\alpha}$ images of the sun have been very interesting and useful scientifically, but have been only five-minute 'snapshots' obtained on sounding rocket flights. All of these observations to date have been snapshots, with no time resolution to observe changes in the chromospheric structure as a result of the evolving magnetic field, and its effect on the Lyman-o intensity. The $Lyman-{\alpha}$ Imaging Solar Telescope(LIST) can provide a unique opportunity for the study of the sun in the $Lyman-{\alpha}$ region with the high time and spatial resolution for the first time. Up to the 2nd year development, the preliminary design of the optics, mechanical structure and electronics system has been completed. Also the mechanical structure analysis, thermal analysis were performed and the material for the structure was chosen as a result of these analyses. And the test plan and the verification matrix were decided. The operation systems, technical and scientific operation, were studied and finally decided. Those are the technical operation, mechanical working modes for the observation and safety, the scientific operation and the process of the acquired data. The basic techniques acquired through the development of satellite based solar telescope are essential for the construction of space environment forecast system in the future. The techniques which we developed through this study, like mechanical, optical and data processing techniques, could be applied extensively not only to the process of the future production of flight models of this kind, but also to the related industries. Also, we can utilize the scientific achievements which are obtained throughout the project And these can be utilized to build a high resolution photometric detectors for military and commercial purposes. It is also believed that we will be able to apply several acquired techniques for the development of the Korean satellite projects in the future.

Evaluate the implementation of Volumetric Modulated Arc Therapy QA in the radiation therapy treatment according to Various factors by using the Portal Dosimetry (용적변조회전 방사선치료에서 Portal Dosimetry를 이용한 선량평가의 재현성 분석)

  • Kim, Se Hyeon;Bae, Sun Myung;Seo, Dong Rin;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.167-174
    • /
    • 2015
  • Purpose : The pre-treatment QA using Portal dosimetry for Volumetric Arc Therapy To analyze whether maintaining the reproducibility depending on various factors. Materials and Methods : Test was used for TrueBeam STx$^{TM}$ (Ver.1.5, Varian, USA). Varian Eclipse Treatment planning system(TPS) was used for planning with total of seven patients include head and neck cancer, lung cancer, prostate cancer, and cervical cancer was established for a Portal dosimetry QA plan. In order to measure these plans, Portal Dosimetry application (Ver.10) (Varian) and Portal Vision aS1000 Imager was used. Each Points of QA was determined by dividing, before and after morning treatment, and the after afternoon treatment ended (after 4 hours). Calibration of EPID(Dark field correction, Flood field correction, Dose normalization) was implemented before Every QA measure points. MLC initialize was implemented after each QA points and QA was retried. Also before QA measurements, Beam Ouput at the each of QA points was measured using the Water Phantom and Ionization chamber(IBA dosimetry, Germany). Results : The mean values of the Gamma pass rate(GPR, 3%, 3mm) for every patients between morning, afternoon and evening was 97.3%, 96.1%, 95.4% and the patient's showing maximum difference was 95.7%, 94.2% 93.7%. The mean value of GPR before and after EPID calibration were 95.94%, 96.01%. The mean value of Beam Output were 100.45%, 100.46%, 100.59% at each QA points. The mean value of GPR before and after MLC initialization were 95.83%, 96.40%. Conclusion : Maintain the reproducibility of the Portal Dosimetry as a VMAT QA tool required management of the various factors that can affect the dosimetry.

  • PDF

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF

The effect of nutritional supply on clinical outcomes and nutritional status in critically ill patients receiving continuous renal replacement therapy (지속적 신대체요법을 받은 중환자에서 영양공급이 임상결과와 영양상태에 미치는 영향)

  • Kim, Ju Yeun;Kim, Ji-Myung;Kim, Yuri
    • Journal of Nutrition and Health
    • /
    • v.48 no.3
    • /
    • pp.211-220
    • /
    • 2015
  • Purpose: This study was designed to investigate whether nutritional supply influences biochemical markers and clinical outcomes in patients who received continuous renal replacement therapy (CRRT) by evaluating adequacy of nutritional supply for patients. Methods: From January 2012 to December 2013, 239 adult patients who received CRRT in the intensive care unit for more than 3 days were included. General information from electronic medical records and nutritional status related biochemical data and clinical outcomes on the first day of CRRT and 2 weeks after CRRT were collected. Results: The rate of delivered energy and protein was 68.06% and 43.13% which was much lower than energy and protein supply based on their requirement. When the patients were divided into two groups according to 70% of energy received rate and 50% of protein received rate, the group with more than 70% of energy received rate showed significant decrease of length of hospital stay (p = 0.007), length of stay in intensive care unit (ICU) (p = 0.008), duration of CRRT (p < 0.001), and APACHE II score (p < 0.001) compared to less than 70% of energy received rate after adjusting for age. In addition, the group with more than 50% of protein received rate showed decreased mortality (p = 0.031), length of hospital stay (p = 0.008), length of ICU stay (p = 0.035), duration of CRRT (p < 0.001), and APACHE II score (p < 0.001) after adjusting for age. We found that the level of hematocrit (p = 0.006) was significantly improved in the group with more than 70% of energy received rate, and the level of TLC (p = 0.049), hematocrit (p = 0.041) was significantly improved in the group with more than 50% of protein received rate. We also found that energy delivery was negatively correlated with length of stay in ICU (p = 0.049) and positively correlated with level of calcium (p = 0.037). In addition, protein delivery was correlated with the levels of serum total protein (p = 0.021), serum albumin (p = 0.048), hematocrit (p = 0.009), and total cholesterol (p = 0.021) when dead patients were included, but was correlated with the levels of hematocrit (p = 0.034) and calcium (p = 0.024) when dead patients were excluded. Conclusion: Proper nutritional delivery may help patients' clinical outcomes for patients receiving CRRT. However, their actual intakes of energy and protein were not adequate for their requirements. Identification of patients with malnutrition is necessary and a multidisciplinary approach for systemic management is also required.

A Collaborative Filtering System Combined with Users' Review Mining : Application to the Recommendation of Smartphone Apps (사용자 리뷰 마이닝을 결합한 협업 필터링 시스템: 스마트폰 앱 추천에의 응용)

  • Jeon, ByeoungKug;Ahn, Hyunchul
    • Journal of Intelligence and Information Systems
    • /
    • v.21 no.2
    • /
    • pp.1-18
    • /
    • 2015
  • Collaborative filtering(CF) algorithm has been popularly used for recommender systems in both academic and practical applications. A general CF system compares users based on how similar they are, and creates recommendation results with the items favored by other people with similar tastes. Thus, it is very important for CF to measure the similarities between users because the recommendation quality depends on it. In most cases, users' explicit numeric ratings of items(i.e. quantitative information) have only been used to calculate the similarities between users in CF. However, several studies indicated that qualitative information such as user's reviews on the items may contribute to measure these similarities more accurately. Considering that a lot of people are likely to share their honest opinion on the items they purchased recently due to the advent of the Web 2.0, user's reviews can be regarded as the informative source for identifying user's preference with accuracy. Under this background, this study proposes a new hybrid recommender system that combines with users' review mining. Our proposed system is based on conventional memory-based CF, but it is designed to use both user's numeric ratings and his/her text reviews on the items when calculating similarities between users. In specific, our system creates not only user-item rating matrix, but also user-item review term matrix. Then, it calculates rating similarity and review similarity from each matrix, and calculates the final user-to-user similarity based on these two similarities(i.e. rating and review similarities). As the methods for calculating review similarity between users, we proposed two alternatives - one is to use the frequency of the commonly used terms, and the other one is to use the sum of the importance weights of the commonly used terms in users' review. In the case of the importance weights of terms, we proposed the use of average TF-IDF(Term Frequency - Inverse Document Frequency) weights. To validate the applicability of the proposed system, we applied it to the implementation of a recommender system for smartphone applications (hereafter, app). At present, over a million apps are offered in each app stores operated by Google and Apple. Due to this information overload, users have difficulty in selecting proper apps that they really want. Furthermore, app store operators like Google and Apple have cumulated huge amount of users' reviews on apps until now. Thus, we chose smartphone app stores as the application domain of our system. In order to collect the experimental data set, we built and operated a Web-based data collection system for about two weeks. As a result, we could obtain 1,246 valid responses(ratings and reviews) from 78 users. The experimental system was implemented using Microsoft Visual Basic for Applications(VBA) and SAS Text Miner. And, to avoid distortion due to human intervention, we did not adopt any refining works by human during the user's review mining process. To examine the effectiveness of the proposed system, we compared its performance to the performance of conventional CF system. The performances of recommender systems were evaluated by using average MAE(mean absolute error). The experimental results showed that our proposed system(MAE = 0.7867 ~ 0.7881) slightly outperformed a conventional CF system(MAE = 0.7939). Also, they showed that the calculation of review similarity between users based on the TF-IDF weights(MAE = 0.7867) leaded to better recommendation accuracy than the calculation based on the frequency of the commonly used terms in reviews(MAE = 0.7881). The results from paired samples t-test presented that our proposed system with review similarity calculation using the frequency of the commonly used terms outperformed conventional CF system with 10% statistical significance level. Our study sheds a light on the application of users' review information for facilitating electronic commerce by recommending proper items to users.

Mapping Heterogenous Ontologies for the HLP Applications - Sejong Semantic Classes and KorLexNoun 1.5 - (인간언어공학에의 활용을 위한 이종 개념체계 간 사상 - 세종의미부류와 KorLexNoun 1.5 -)

  • Bae, Sun-Mee;Im, Kyoung-Up;Yoon, Ae-Sun
    • Korean Journal of Cognitive Science
    • /
    • v.21 no.1
    • /
    • pp.95-126
    • /
    • 2010
  • This study proposes a bottom-up and inductive manual mapping methodology for integrating two heterogenous fine-grained ontologies which were built by a top-down and deductive methodology, namely the Sejong semantic classes (SJSC) and the upper nodes in KorLexNoun 1.5 (KLN), for HLP applications. It also discusses various problematics in the mapping processes of two language resources caused by their heterogeneity and proposes the solutions. The mapping methodology of heterogeneous fine-grained ontologies uses terminal nodes of SJSC and Least Upper Bounds (LUB) of KLN as basic mapping units. Mapping procedures are as follows: first, the mapping candidate groups are decided by the lexfollocorrelation between the synsets of KLN and the noun senses of Sejong Noun Dfotionaeci(SJND) which are classified according to SJSC. Secondly, the meanings of the candidate groups are precisely disambiguated by linguistic information provided by the two ontologies, i.e. the hierarchicllostructures, the definitions, and the exae les. Thirdly, the level of LUB is determined by applying the appropriate predicates and definitions of SJSC to the upper-lower and sister nodes of the candidate LUB. Fourthly, the mapping possibility ic inthe terminal node of SJSC is judged by che aring hierarchicllorelations of the two ontologies. Finally, the ituorrect synsets of KLN and terminologiollocandidate groups are excluded in the mapping. This study positively uses various language information described in each ontology for establishing the mapping criteria, and it is indeed the advantage of the fine-grained manual mapping. The result using the proposed methodology shows that 6,487 LUBs are mapped with 474 terminal and non-terminal nodes of SJSC, excluding the multiple mapped nodes, and that 88,255 nodes of KLN are mapped including all lower-level nodes of the mapped LUBs. The total mapping coverage is 97.91% of KLN synsets. This result can be applied in many elaborate syntactic and semantic analyses for Korean language processing.

  • PDF

Improving Curing Rate and Physical Properties of Korean Dendropanax Lacquer with Thermal and Photo Initiator by Dual Curing (이중경화법을 이용한 열개시제 및 광개시제가 배합된 황칠도료의 경화속도 촉진 및 물성향상 연구)

  • Hwang, Hyeon-Deuk;Moon, Je-Ik;Park, Cho-Hee;Kim, Hyun-Joong;Hwang, Baik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.4
    • /
    • pp.333-340
    • /
    • 2010
  • The Korean Dendropanax lacquer, made from a natural resinous sap from Dendropanax orbifera Lev., was used as a golden and transparent varnish for the traditional artifacts (armor uits, helmets, arrowheads, etc.) to make them be brilliant golden color. The cured film of the acquer has excellent protective properties such as weatherability, water resistance, and nticorrosive. But, one of disadvantages is that takes a long time and much energy to fulfill curing the lacquer. The chemical constituents of the lacquer contained conjugated diene compounds s the photopolymerizable monomers. These monomers easily polymerized in sunlight to form olden-colored, hard-coating films in a short time. Photooxidation may be one of the most mportant reactions in the chemistry of the lacquer. Although the Korean Dendropanax Lacquer hould be dried to a thoroughly dry stage to achieve optimal film properties, curing with elevated emperatures may be required for the protracted curing time at atmospheric temperature. So we ntended to accelerate the curing rate of the lacquer by dual curing of thermal and radiation uring. The effect of thermal initiator on the thermal curing reaction was evaluated by monitoring he changes in double bond peak with FT-IR. Then the curing rate of the lacquer blended with hermal initiator and photoinitiator together was measured during dual curing using a RPT with V spot curing machine. Thermal initiator not only accelerated the curing rate but also improved he physical property. And the curing rate of the Korean Dendropanax lacquer was improved by ual curing method of thermal and UV curing. According to these results, the application area of he Korean Dendropanax lacquer could be expanded to surface coatings for electronic devices uch as mobile phones or electronics.

Analysis of the Imaging Dose for IGRT/Gated Treatments (영상유도 및 호흡동조 방사선치료에서의 영상장비에 의한 흡수선량 분석)

  • Shin, Jung-Suk;Han, Young-Yih;Ju, Sang-Gyu;Shin, Eun-Hyuk;Hong, Chae-Seon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.42-48
    • /
    • 2009
  • Purpose: The introduction of image guided radiation therapy/four-dimensional radiation therapy (IGRT/4DRT) potentially increases the accumulated dose to patients from imaging and verification processes as compared to conventional practice. It is therefore essential to investigate the level of the imaging dose to patients when IGRT/4DRT devices are installed. The imaging dose level was monitored and was compared with the use of pre-IGRT practice. Materials and Methods: A four-dimensional CT (4DCT) unit (GE, Ultra Light Speed 16), a simulator (Varian Acuity) and Varian IX unit with an on-board imager (OBI) and cone beam CT (CBCT) were installed. The surface doses to a RANDO phantom (The Phantom Laboratory, Salem, NY USA) were measured with the newly installed devices and with pre-existing devices including a single slice CT scanner (GE, Light Speed), a simulator (Varian Ximatron) and L-gram linear accelerator (Varian, 2100C Linac). The surface doses were measured using thermo luminescent dosimeters (TLDs) at eight sites-the brain, eye, thyroid, chest, abdomen, ovary, prostate and pelvis. Results: Compared to imaging with the use of single slice non-gated CT, the use of 4DCT imaging increased the dose to the chest and abdomen approximately ten-fold ($1.74{\pm}0.34$ cGy versus $23.23{\pm}3.67$cGy). Imaging doses with the use of the Acuity simulator were smaller than doses with the use of the Ximatron simulator, which were $0.91{\pm}0.89$ cGy versus $6.77{\pm}3.56$ cGy, respectively. The dose with the use of the electronic portal imaging device (EPID; Varian IX unit) was approximately 50% of the dose with the use of the L-gram linear accelerator ($1.83{\pm}0.36$ cGy versus $3.80{\pm}1.67$ cGy). The dose from the OBI for fluoroscopy and low-dose mode CBCT were $0.97{\pm}0.34$ cGy and $2.3{\pm}0.67$ cGy, respectively. Conclusion: The use of 4DCT is the major source of an increase of the radiation (imaging) dose to patients. OBI and CBCT doses were small, but the accumulated dose associated with everyday verification need to be considered.

Sexuality, Contraception, and Induced Abortion among Adolescents and Young Adults in the Export Processing Zones of Korea (미혼여성의 성, 피임, 그리고 인공유산 - 수출공단지역의 사례연구)

  • 조성남
    • Korea journal of population studies
    • /
    • v.19 no.1
    • /
    • pp.93-122
    • /
    • 1996
  • This is a study of the determinants of sexual, contraceptive, and abortion behavior among unmarried female adolescents and young adults, which has emerged as a growing and serious health problem in Korea. As part of a larger project, data were gathered in three export zones: Kuro (Seoul), Kumi (Kyngbuk) Masan Changwon (Kyongnam) ; and the study samples are regrouped into three categories: 1) factory workers, i.e. , the reference group serving as program participants, 2) entertainment workers, and 3) ob-gyn patients. This study indicates that entertainment workers are at highest risk of experiencing premarital sex, STDs, contraceptive failure, unwanted pregnancies, and induced abortion. Of them, 20 percent had STDs as a result of first sexual experience: and about seven tenths had two or more pregnancies due to the adoption of low-efficacy methods. The proportion of those who had ever been pregnant was 60 percent for the group as a whole: 36 percent for the program participants: 64 percent for the entertainment workers ; and 91 percent four the ob-gyn patients. These proportions are exactly the same for abortion in each group, which means that all pregnancies ended in induced abortion. Of the respondents who said that they were sexually active at the time of survey, abortions were very high: 1.6 for the program participants, 2.3 for the entertainment workers, and 1.9 for the ob-gyn patients. About 80 percent of the women had abortions during the first trimester, and two thirds of the first abortions took place between the ages of 20 and 23. About one fourth experienced post-abortion complication, which was highest among the program participants (39 percent). Sixty percent of those with complications visited a hospital or took medicine to treat the problem. Even after the experience of induced abortion, the use of contraception was very low, except among the entertainment workers, whose level of use reached 53 percent. The most obvious recommendation, arising from this research, is that 'good-quality' counselling and family planning services be established under the auspices of both national and local government, particularly targeted for the entertainment workers as well as the factory workers in various textile, electronic, manufacturing, and other industrial sectors. We believe that entertainment sectors should be restructured radically so that young women who work for amusement bars and other entertainment sectors obtain protection from the risk of having unwanted pregnancies, STDs, and induced abortion.

  • PDF