• Title/Summary/Keyword: Electronic Complaints

Search Result 44, Processing Time 0.021 seconds

A Study on the model of CCTV Image Information Integration portal (CCTV 영상자료 통합포털 구축 모델에 관한 연구)

  • Kang, Poo-Reum;Kim, Kui-Nam J.
    • Convergence Security Journal
    • /
    • v.12 no.2
    • /
    • pp.43-51
    • /
    • 2012
  • CCTV would be the effective way in the prevention of abuse, as well as recorded image information evidence of the crime as a significant legal effect. But recorded image information As evidence by utilizing the Complaint/complaint handling, and administrative business processes that are currently operating offline procedural complexity and unnecessary time appear costly, privacy remains an issue to be solved, etc. Runoff. In this paper, incidence rate of offline business processing phase to solve the problems proposed to build unified portal for CCTV image information and the existing studies on the effectiveness of electronic civil service system, previous studies by analyzing e-government in accordance with laws and privacy laws, CCTV image information portal deployment model is applied to data integration occurs are trying to solve the problem effectively.

Related Factors of Severity Rated by Korean Triage and Acuity Scale (KTAS) among Older Adults at the Emergency Departments (일개 지역 응급의료센터 방문 노인의 중증도 영향 요인)

  • Shin, Dong-Soo;Kim, Mi Sook
    • Journal of East-West Nursing Research
    • /
    • v.24 no.2
    • /
    • pp.146-153
    • /
    • 2018
  • Purpose: This study aimed to identify characteristics and severity assessed by Korean Triage and Acuity Scale (KTAS) among 2,496 older adults aged 65 and over who visited an emergency department (ED) located in Chuncheon city. Methods: Data were collected via electronic medical records from two hospitals from January to December of 2016. Chi square test and logistic regression were applied using SPSS 22.0. Results: 53.5% of the participants were women and 17.6% of visits were done by aged 85 and older. ED visits by ambulance were 33.9%. More than two-third of older adults' ED visits were emergent status. Severity of the ED visits of older adults were rated by KTAS. Commonly reported chief complaints of the ED visits were dizziness, dyspnea, chest pain, abdominal pain, and hypoalbuminemia. Among them, dizziness, chest pain, dyspnea, and hypoalbuminemia were related factors for being-emergent condition. Conclusion: Strategies for older adults' chief complaints are needed in order to reduce unexpected ED visits.

A Study on the Efficiency of Horizontal Direction Deck-charge Blasting Method Using Electronic Detonator (전자뇌관을 이용한 수평방향 데크차지 발파공법의 효율성검토 연구)

  • Yoon, Ji-Sun;Hahn, Suk-Ju;Bae, Sang-Hun
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.4
    • /
    • pp.5-11
    • /
    • 2013
  • In close to downtown construction, the main problem is complaints caused by blasting vibration and noise. To reduce blasting vibration and noise, deck-charge blasting method using electronic detonator can be more secure because there is no cut-off problem. And in this method it is possible to blast in horizontal direction. In this study, the efficiency of horizontal direction deck-charge blasting method using electronic detonator is compared to that of the existing blasting method. And the possibility of applying the construction site is evaluated. As a result, the reduction of blasting vibration, noise and secondary breaking has been determined, as well as large-scale blasting in the vibration criterion can be regulated by the overall increase in blasting efficiency.

Capacity Optimizing method of Distributed Generators in Stand-Alone Microgrid Considering Grid Link-Characteristics

  • Han, Soo-Kyeong;Choi, Hyeong-Jin;Cho, Soo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1483-1493
    • /
    • 2018
  • Recently, more power facilities are needed to cope with the increasing electric demand. However, the additional construction of generators, transmission and distribution installations is not easy because of environmental problems and citizen's complaints. Under this circumstance, a microgrid system with distributed renewable resources emerges as an alternative of the traditional power systems. Moreover, the configuration of power system changes with more DC loads and more DC installations. This paper is written to introduce an idea of a genetic algorithm-based solution to determine the optimal capacity of the distributed generators depending on the types of system configuration: AC-link, DC-link and Hybrid-link types. In this paper, photovoltaic, wind turbine, energy storage system and diesel generator are considered as distributed generators and the feasibility of the proposed algorithm is verified by comparing the calculated capacity of each distributed resource with HOMER simulation results for 3 types of system configuration.

A Study on Text Mining Methods to Analyze Civil Complaints: Structured Association Analysis (민원 분석을 위한 텍스트 마이닝 기법 연구: 계층적 연관성 분석)

  • Kim, HyunJong;Lee, TaiHun;Ryu, SeungEui;Kim, NaRang
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.3
    • /
    • pp.13-24
    • /
    • 2018
  • For government and public institutions, civil complaints containing direct requirements of citizens can be utilized as important data in developing policies. However, it is difficult to draw accurate requirements using text mining methods since the nature of the complaint text is unstructured. In this study, a new method is proposed that draws the exact requirements of citizens, improving the previous text mining in analyzing the data of civil complaints. The new text-mining method is based on the principle of Co-Occurrences Structure Map, and it is structured by two-step association analysis, so that it consists of the first-order related word and a second-order related word based on the core subject word. For the analysis, 3,004 cases posted on the electronic bulletin board of Busan City for the year 2016 are used. This study's academic contribution suggests a method deriving the requirements of citizens from the civil affairs data. As a practical contribution, it also enables policy development using civil service data.

Application of Electronic Deck Charge Blasting Method to a Vertical Shaft Excavation (수직구 굴착시 전자뇌관을 이용한 Deck-Charge 발파 시공사례)

  • Kim, Jae-Hong;Kim, Hee-Do;Lee, Jun-Won;Kim, Gab-Soo;Son, Young-Bok;Kim, Jae-Hoon
    • Explosives and Blasting
    • /
    • v.31 no.1
    • /
    • pp.64-75
    • /
    • 2013
  • This case study deals with an excavation blasting carried out at "Sooseo-Pyeongtek ${\bigcirc}$-${\bigcirc}$ section construction site" in the vicinity of residential area. Originally, the sequential blasting (multi-stage blasting) using electric detonators was planed in this area. However, there was a concern that the sequential blasting method could increase the construction cost by delaying the construction period due to possible complaints from local residents. As an alternative, electronic deck blasting technique was taken in order to meet the ground vibration regulation (0.2cm/s, in apartment area) and to keep the construction schedule. The performance of the electronic deck charge blasting was two times better than the sequential blasting with electric detonators and the level of ground vibration was also within the regulatory value (0.2cm/s). In particular, it was shown that the use of electronic detonater eDevII, which was developed for tunnel, could provide more convenient and electrically safer working condition.

ICT Fusion Type Plasma Waste Heat Ventilation System for Improvement of Indoor Air Quality (실내 공기질 개선을 위한 ICT 융복합형 플라즈마 폐열 환기 시스템)

  • Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1215-1220
    • /
    • 2019
  • Currently, each farm bears both the outbreak of foot-and-mouth disease and the damage caused by AI. In addition, complaints about odors in the livestock industry are constantly being recovered and are expected to occur in the future. The purpose of this study is to improve the indoor air quality of enclosed facilities such as barns, houses, pigsty, and etc. This paper develops low-temperature plasma waste heat ventilation system to be installed in ventilation unit location and standardizes heat exchange element, low-temperature plasma lamp, and ballast for enhanced air cleaning function. In addition, this study intends to develop a new control system so that the farmers can connect with existing weather systems, flow fans, and other facility equipment by incorporating ICT.

Analysis of the recognition level of personal information protection of public institutions in the local governments (지방자치단체 공공기관의 개인정보보호에 관한 인식 수준 분석)

  • Jang, Ji-Hye;Mok, Hwa-Jung;Kim, Yeon-Seo;Choi, Jin-Sik;Choi, Chul-Jae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.3
    • /
    • pp.345-350
    • /
    • 2016
  • It is the personal information protection law is prepared, in the government, to develop a personal information protection basic plan has been implemented. However, year after year, complaints caused by infringement of personal information in public institutions has increased. In this paper, the recognition level of analysis related to the protection of personal information of local governments, public institutions through a questionnaire survey, raised the need for improvement.

Comparative Study on the Characteristics of Ground Vibrations Produced from Borehole Blast Tests Using Electronic and Electric Detonators (전자뇌관과 전기뇌관을 사용한 시추공 발파시험에서의 지반진동 특성에 관한 비교 연구)

  • Choi, Hyung-Bin;Won, Yeon-Ho
    • Explosives and Blasting
    • /
    • v.28 no.2
    • /
    • pp.37-49
    • /
    • 2010
  • Ground vibration caused by blasting in the urban area close to structures can give some indirect damage to human body and may lead to structural damage to buildings. At the stage of design or when complaints were filed by residents, the test blasting in borehole, which is most practical for expressing simple vibration wave form quantitatively, is usually chosen for assessing the degree of damage to structures. In this paper, some lessons gained from the application of electronic detonator triggering system in borehole test blasting are presented. The difference in delay time of detonator when borehole is blasted by electronic detonator and electric detonator are discussed. The peak particle velocities measured at the structure embedded in the similar rock layer to main line of tunnel at test site and measured at the road surface just above the tunnel having different overburden layers were analysed to draw their relationship. By comparing the results with those appearing in some published literatures, the usefulness of the borehole test blasting and the importance of delay time of detonator are addressed.

A Case Study of Deep Shaft Blasting for Reducing Ground Vibration in Urban Area (도심지의 대심도 수직구 발파에서 지반진동저감 시공 사례)

  • Hwang, Nam-Sun;Kim, Kyung-Hyun;Kim, Jeoung-Hwan;Jung, Min-Sung;Lee, Hyeung-Jin;Na, Gyeong-Min
    • Explosives and Blasting
    • /
    • v.39 no.2
    • /
    • pp.15-26
    • /
    • 2021
  • Domestic electronic detonators are used widely in many quarry and construction sites since its launch at 2013. In the case of SOC projects conducted in the city, most of them are designed in high-depth to reduce complaints. The high-depth excavation needs a long construction period and huge cost for building shaft and ventilation hole. Mechanical excavation method is applied when safety things are located nearby the site. Solidity of rock and machine's performance affect on the method's efficiency. So as the efficiency is getting lower, the construction period is extended, and the cost is increases as well. This case study is about changing the machine excavation method to the blasting method which is electronic detonator applied at the shaft construction site in the city. This is an example of using electronic detonators on the construction site in reducing blast-noise and vibration while meeting environmental regulatory standards.