• Title/Summary/Keyword: Electron-Beam Energy

Search Result 691, Processing Time 0.03 seconds

Effect of Electron Beam Irradiation on the Properties of Softwood Unbleached Kraft Pulp (전자선 전처리에 따른 침엽수 미표백 크라프트 펄프의 특성평가)

  • Kim, Eun Hea;Lee, Ji Young;Jeun, Joon Pyo;Kim, Sun Young;Kim, Chul Hwan;Park, Jong Hye
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.5
    • /
    • pp.68-73
    • /
    • 2015
  • Electron beam irradiation is also an eco-friendly treatment compared to other physical and chemical treatments. In this study, we attempted to evaluate the possibilities of energy savings by applying electron beam irradiation to the refining process. After softwood unbleached kraft pulp (UKP) was irradiated with electron beams at 50 and 100 kGy, it was beaten in a laboratory beater, and then its freeness and fiber properties were analyzed. The physical properties of their fiber handsheet were also and measured. As the irradiation dose of the electron beam and the beating time increased, lower freeness and fiber lengths of the UKP were observed. Handsheets made from UKP that was irradiated by electron beam and beaten showed a reciprocal relationship with the irradiation dose of the electron beam, in particular, the strength of the handsheets decreased dramatically at 100 kGy of irradiation. Therefore, it was confirmed that electron beam irradiation is effective in reducing the beating time or beating energy. But the irradiation dose must be controlled under 50 kGy to minimize the loss of paper strength.

Measurement of Bremsstrahlung Radiation with Electron Beam Energy

  • Srivastava, R.P.;Chaurasia, P.P.;Prasiko, G.;Jha, A.K.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.235-236
    • /
    • 2002
  • A Klystron powered dual photon energy electron linear accelerator 2300 C/D from Varian Associates has been installed in our center. From the radiological safety view as well as treatment planning, the output (contamination) of Bremsstrahlung Radiation with electron beam energy determined accurately. It has been found 0.5% to 4.7% with increasing the electron beam energy which is the clinically not much significant in the treatment of the malignant diseases with the treatment of electron beam.

  • PDF

A Study on Pattern Fabrication using Proximity Effect Correction in E-Beam Lithography (전자빔 리소그래피에서의 근접효과 보정을 이용한 패턴 제작에 관한 연구)

  • Oh, Se-Kyu;Kim, Dong-Hwan;Kim, Seung-Jae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.2
    • /
    • pp.1-10
    • /
    • 2009
  • This study describes the electron beam lithography pattern fabrication using the proximity effect correction. When electron beam exposes into electron beam resist, the beam tends to spread inside the substance (forward scattering). And the electron beam reflected from substrate spreads again (back scattering). These two effects influence to distribution of the energy and give rise to a proximity effect while a small pattern is generated. In this article, an electron energy distribution is modeled using Gaussian shaped beam distribution and those parameters in the model are computed to solidify the model. The proximity effect is analyzed through simulations and appropriate corrections to reducing the proximity effect are suggested. It is found that the proximate effect can be reduced by adopting schemes of dose adjustment, and the optimal dose is determined through simulations. The proposed corrected proximity effect correction is proved by experiments.

  • PDF

Characteristics of Electron Beam Extraction in Large Area Electron Beam Generator

  • Woo, Sung-Hun;Lee, Hong-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.1
    • /
    • pp.10-14
    • /
    • 2004
  • A large area electron beam generator has been developed for industrial applications, for example, waste water cleaning, flue gas treatment, and food pasteurization. The operational principle is based on the emission of secondary electrons from the cathode when ions in the plasma contact the cathode, which are accelerated toward the exit window by the gradient of the electric potential. Conventional electron beam generators require an electron beam scanning mechanism because a small area thermal electron emitter is used. The electron beam of the large area electron beam generator does not need to be scanned over target material because the beam area is considerable. We have fabricated a large area electron beam generator with peak energy of 200keV, and a beam diameter of 200mm. The electron beam current has been investigated as a function of accelerating voltage and distance from the extracting window while its radial distribution in front of the extracting window has been also measured.

Development of a neural network method for measuring the energy spectrum of a pulsed electron beam, based on Bremsstrahlung X-Ray

  • Sohrabi, Mohsen;Ayoobian, Navid;Shirani, Babak
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.266-272
    • /
    • 2021
  • In the pulsed electron beam generators, such as plasma focus devices and linear induction accelerators whose electron pulse width is in the range of nanosecond and less, as well as in cases where there is no direct access to electron beam, like runaway electrons in Tokamaks, measurement of the electron energy spectrum is a technical challenge. In such cases, the indirect measurement of the electron spectrum by using the bremsstrahlung radiation spectrum associated with it, is an appropriate solution. The problem with this method is that the matrix equation between the two spectrums is an ill-conditioned equation, which results in errors of the measured X-ray spectrum to be propagated with a large coefficient in the estimated electron spectrum. In this study, a method based on the neural network and the MCNP code is presented and evaluated to recover the electron spectrum from the X-ray generated by collision of the electron beam with a target. Multilayer perceptron network showed good accuracy in electron spectrum recovery, so that for the X-ray spectrum with errors of 3% and 10%, the network estimated the electron spectrum with an average standard error of 8% and 11%, on all of the energy intervals.

A Consideration on the Characteristics of Electron Beam Dose Distributions for Clinical Applications (임상적용을 위한 전자선의 선량분포 특성에 대한 고찰)

  • Cha, Dong-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.65-69
    • /
    • 2010
  • High energy electron beams were to concentrically dose inside a tumor and more energy is a shape decreased of dose. Therefore, it is useful to radiation therapy of a tumor. Also high energy electron beams ionized into collision with a atom in structure material of tissue and it has big changes to dose distribution by multiple scattering. The study had to establish characteristic of electron beams from interaction of electron beams and materials. Experiment method was to measure dependence of electron beam central axis for depth dose curve, field flatness and symmetry and field size dependence. The results were able to evaluate data for a datum pint of electron beam. Also radiotherapy has to be considered for not only energy pencil of lines but characteristic, electron guide and isodose curves distribution.

  • PDF

Calculation of Energy Spectra for 6 MeV Electron Beam of LINAC Using MCNPX (MCNPX를 이용한 선형가속기의 6 MeV 전자선에 대한 에너지분포 계산)

  • Lee, Jeong-Ok;Jeong, Dong-Hyeok
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.224-231
    • /
    • 2006
  • The electron energy spectra for 6 MeV electron beam were calculated using a MCNPX code. The head of the linear accelerator (ML6M; Mitsubishi, Japan) was modelled for this study. The energy spectrum of the initial electron beam was assumed to be Gaussian and the mean energy was determined by evaluating the measured and calculated values of $R_{50}$ and dose profiles in air. The energy distributions for electrons and photons at the interested points in the head of the linear accelerator were calculated by appling the Initial beam parameters. The effect of contaminant photons on depth dose curves were estimated by the photon energy spectra at the end of the applicator.

  • PDF

Radiotherapy Treatment Planning using Computed Tomography in Breast Cancer (유방암에서 CT planning를 이용한 치료계획)

  • 김성규;신세원;김명세
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.59-65
    • /
    • 1992
  • Carcimoma of the breast are first frequency malignancy in women in the world. third frequency in Korea. Radiation therapy in breast cancer were treated through opposed tangential fields with photon beam or electron beam. Density within the field and thickness to tumor are very importent factors determining dose distribution in radiation therapy of electron beam. Radiotherapy traetment planning using computed tomography in Breast cancer are able to ideal dose distribution. Authors concluded as following. 6MeV energy of electron beam propered below 1.5cm in chest wall's thickness or internal mammary lymphnode's depth. 9MeV energy of electron beam from 1.5cm to 2.0cm. 12 MeV energy of electron beam from 2.0cm to 2.5cm.

  • PDF

The Effect of Electron Beam Irradiation on the Extraction of Lignin from Kenaf (케나프로부터 리그닌 추출에 대한 전자선의 영향)

  • Oh, Doori;Jeun, Joon Pyo;Shin, Hye Kyoung;Kang, Phil Hyun
    • Journal of Radiation Industry
    • /
    • v.6 no.2
    • /
    • pp.125-128
    • /
    • 2012
  • Kenaf (Hibiscuc cannabinus L.) is a renewable resource for industry and kenaf lignin is syringyl-guaiacyl lignin. The electron beam irradiated on kenaf core various doses range from 200 to 1,000 kGy to improve delignification. The yield of lignin, which is 2.53 g from 10 g of electron beam irradiated kenaf core. A comparison extracted lignin between from native kenaf core and electron beam irradiated kenaf core was then studied through chemical structure and bonding property by a Fourier transform infrared spectroscopy (FT-IR). Thermal stability of the extracted-purified lignin was performed via differential scanning calorimetry (DSC). These results were explained that electron beam irradiation increased performance of extracting efficiency.