• Title/Summary/Keyword: Electron range

Search Result 1,835, Processing Time 0.034 seconds

Construction of a microwave free electron laser and studies of its characteristics (마이크로파 자유전자 레이저의 제작 및 동작특성 연구)

  • 이관철;정기형
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.43-49
    • /
    • 1992
  • A microwave free electron laser which consists of Marx generator, vacuum diode, bifilar helical wiggler, and guide solenoid was designed and constructed. The analysis of the magnetic field distributions of the bifilar helical wiggler and computer simulation of electron trajectories with the perpendicular effect of space charges led to the conclusion that the magnetic field distributions are suitable for the electron beam injection. Output frequency in a single $TE_{11}$

  • PDF

Effectiveness for Beauty Improvement of Geranium essential oil on Skin Troubles by Surfactant (계면활성제에 의해 손상된 피부의 Geranium essential oil 미용증진 효과)

  • Choi, Jeung-Suk
    • Journal of the Korean Society of Fashion and Beauty
    • /
    • v.2 no.2 s.2
    • /
    • pp.101-106
    • /
    • 2004
  • Allergic contact dermatitis is a common skin disease resulting from specific immunologic sensitization to topically applied various allergen. The Purpose of this study was to investigate skin morphologic cahnges by light microscopic and scanning electron Microscope, changes of protein band by SDS-PAGE(SDS-polyacrylamide gel electrophoresis) in the skin effectiveness for beruty improvement of Geranium essential oil on skin troubles by surfactant. The results of the study are as follows, 1. From the observed result of FE-Scanning Electron Microscope, groups treated by Geranium essential oil in group treated Geranium essential oil during 1 week in surfactant treated group during 1 week, the group was repaired in irregularity surface of tissue by alleviate-keratinization of Geranium essential oil. 2. As a result of protein analysis the group treated on surfactant was rised protein upper range of 97,0004a11on by hyper-keratinization and group treated during 1 week by surfactant was decreased protein below range of 43,000dalton.

  • PDF

Development of a Wideband EPR Spectrometer with Microstrip and Loop Antennas

  • Ponomaryov, A.N.;Choi, K.Y.;Suh, B.J.;Jang, Z.H.
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.178-182
    • /
    • 2013
  • We have developed a new non-conventional electron paramagnetic resonance (EPR) spectrometer, in which no resonant cavity was used. We previously demonstrated a wide frequency range operation of an EPR spectrometer using two loop antennas, one for a microwave transmission and the other for signal detection [1]. In contrast to Ref. [1], the utilization of a microstrip antenna as a transmitter enhanced a capability of wide-band operation. The replacement of conventional capacitors with varactor diodes makes resonance condition easily reproducible without any mechanical action during tuning and matching procedure since the capacitance of the diodes is controlled electronically. The operation of the new EPR spectrometer was tested by measuring a signal of 1,1-diphenil-2-picrylhydrazyl (DPPH) sample in the frequency range of 0.8-2.5 GHz.

Monte Carlo Simulation of Ion Implantation Profiles Calibrated for Various Ions over Wide Energy Range

  • Suzuki, Kunihiro;Tada, Yoko;Kataoka, Yuji;Nagayama, Tsutomu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.1
    • /
    • pp.67-74
    • /
    • 2009
  • Monte Carlo simulation is widely used for predicting ion implantation profiles in amorphous targets. Here, we compared Monte Carlo simulation results with a vast database of ion implantation secondary ion mass spectrometry (SIMS), and showed that the Monte Carlo data sometimes deviated from the experimental data. We modified the electron stopping power model, calibrated its parameters, and reproduced most of the database. We also demonstrated that Monte Carlo simulation can accurately predict profiles in a low energy range of around 1keV once it is calibrated in the higher energy region.

The Variation of the Characteristics of DLC Thin films by Pulsed Laser Deposition (레이저 증착변수에 의한 다이아몬드상 카본 박막 특성변화)

  • Sim, Gyeong-Seok;Lee, Sang-Ryeol
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.344-348
    • /
    • 1999
  • Diamond like carbon(DLC) thin films possesed not only marvelous material characteristics such as large thermal conductivity, high hardness and being chemically inert, but also possesed negative electron affinity (NEA) properties. The NEA is an extremely desirable property of the material used in microelestronics and vacuum microelestronics device. DLC films were fabricated by pulsed laser deposition(PLD). Theeffect of the laser energy density and the substrate temperature on the properies of DLC films was investigated. The experiment was accomplished at temperatures in the range of room temperature to $600^{\circ}C$. The laser energy density was in the range of 6 $J/cm^2$ to 16 $J/cm^2$.

  • PDF

A Study on the Dielectric Properties of Silicone Rubber due to Hardness Variation (경도 변화에 따른 실리콘 고무의 유전 특성에 관한 연구)

  • Lee, Sung-Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.11
    • /
    • pp.916-921
    • /
    • 2012
  • This research measured the dielectric properties of silicone rubber with various hardness in 100 Hz~3 MHz, $30{\sim}170^{\circ}C$ conditions. When the hardness increases from 65 degree to 75 degree, the dielectric loss increased within frequency range of 100 kHz~3 MHz and was a little change in dielectric loss within temperature range of $90^{\circ}C{\sim}170^{\circ}C$. Thermogravimetric Analysis (TGA) showed the weight change rate increased a little while heated until $800^{\circ}C$. Scanning Electron Microscope (SEM) measurement showed that Aluminium Trihydroxide($AlOH_3$) which acts as a reinforcement agent reduced the size of the particles as the hardness increased.

Temperature Dependence of Mn2+ Paramagnetic Ion in a Stoichiometric LiNbO3 Single Crystal

  • Yeom, Tae Ho;Lee, Soo Hyung
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.221-224
    • /
    • 2013
  • Electron paramagnetic resonance (EPR) spectra of $Mn^{2+}$ impurity ion in Stoichiometric $LiNbO_3$ single crystal (SLN) was investigated with an X-band EPR spectrometer in the temperature range of 3 K~296 K. The intensity of EPR spectrum of $Mn^{2+}$ ion was increased to 20 K and decreased again below 20 K as the temperature decreases. The zero-field splitting parameter D decreased as the temperature increases. It was suggested that $Mn^{2+}$ ion substitute for $Nb^{5+}$ ion instead of $Li^+$ ion. No changes for hyperfine interaction of $Mn^{2+}$ ion was obtained in the temperature range of 3 K~296 K.

Chemical and Thermal Characterizations of Electron Beam Irradiated Jute Fibers (전자빔 조사된 황마섬유의 화학적 및 열적 특성분석)

  • Ji, Sang Gyu;Cho, Donghwan;Lee, Byung Cheol
    • Journal of Adhesion and Interface
    • /
    • v.11 no.4
    • /
    • pp.162-167
    • /
    • 2010
  • In the present work, the effect of electron beam irradiation on the chemical and thermal characteristics of cellulose-based jute fibers was explored by means of chemical analysis, electron spin resonance analysis, ATR-FTIR spectroscopy, thermogravimetric analysis and thermomechanical analysis. Jute fiber bundles were uniformly irradiated in the range of 2~100 kGy by a continuous method using a conveyor cartin an electron beam tunnel. Electron beam treatment, which is a physical approach to change the surfaces, more or less changed the chemical composition of jute fibers. It was also found that the radicals on the jute fibers can be increasingly formed with increasing electron beam intensity. However, the electron beam irradiation did not change significantly the chemical functional groups existing on the jute fiber surfaces. The electron beam irradiation influenced the thermal stability and thermal shrinkage/expansion behavior and the behavior depended on the electron beam intensity.

Radiotherapy Technique of High Energy Electron (고에너지 전자선의 방사선 치료 기술)

  • SUH M.W.;PARK J.I.;CHOI H.S.;KIM W.Y.
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 1985
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefore, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed does, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under $3\%$ errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under $5\%$ errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatters; i.e., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

Studies on Dose Distribution and Treatment Technique of High Energy Electron (고(高)에너지 전자선(電子線) 치료(治療)를 위(爲)한 선량분포(線量分布) 및 기술적(技術的) 문제(問題)의 연구(硏究))

  • Lee, D.H.;Chu, S.S.
    • Journal of Radiation Protection and Research
    • /
    • v.3 no.1
    • /
    • pp.6-22
    • /
    • 1978
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefor, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed doses, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under 3% errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under 5% errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatterers; ie., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF