• 제목/요약/키워드: Electron contamination

검색결과 155건 처리시간 0.022초

The Simulation on Dose Distributions of the 6 MeV Electron Beam in Water Phantom (6 MeV 전자선의 물팬텀 속의 선량분포에 관한 모의계산)

  • Lee, Jeong-Ok;Jeong, Dong-Hyeok;Moon, Sun-Rock
    • Journal of radiological science and technology
    • /
    • 제23권2호
    • /
    • pp.75-79
    • /
    • 2000
  • This study was performed for the clinical applications applying the Monte Carlo methods. In this study we calculated the absorbed dose distributions for the 6 MeV electron beam in water phantom and compared the results with measured values. The energy data of electron beam used in Monte Carlo calculation is the energy distribution for 6 MeV electron beam which is assumed as a Gaussian form. We calculated percent depth doses and beam profiles for three field sizes of $10{\times}10,\;15{\times}15$, and $20{\times}20\;cm^2$ in water phantom using Monte Carlo methods and measured those data using a semiconductor detector and other devices. We found that the calculated percent depth doses and beam profiles agree with the measured values approximately. However, the calculated beam profiles at the edge of the fields were estimated to be lower than the measured values. The reason for that result is that we did not consider the angular distributions of the electrons in phantom surface and contamination of X-rays in our calculations. In conclusion, in order to apply the Monte Carlo methods to the clinical calculations we are to study the source models for electron beam of the linear accelerator beforehand.

  • PDF

Experimentally Minimized Contaminative Condition of Carbonaceous Artifacts in Transmission Electron Microscope (투과전자현미경에 타소질 불순물의 오염 최소화를 위한 실험 조건)

  • Kim, Young-Min;Choi, Joo-Hyoung;Song, Kyung;Kim, Yang-Soo;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • 제39권1호
    • /
    • pp.73-77
    • /
    • 2009
  • Contaminative artifacts such as carbonaceous materials on carbon-coated microgrids are unavoidable, which is induced by electron beam exposure inside electron microscopes. This phenomenon raise a source to produce confusing information to the samples investigated by analytical TEM, which should be alleviated as much as possible. As experimental precautions for reducing this unwanted effect, the use of $LN_2$ cooled anti-contaminator and pre-illumination of electron beam at low magnification can be helpful. Nevertheless, we should be cautious to set an illumination condition for microanalysis because the contaminative effect is dependent with the types of irradiation situations, which is well known to be a decisive factor for causing the carbonaceous artifacts. Accordingly, it is necessary that optimal illumination to minimize the contaminative effect should be selected for improving the accuracy of microanalysis. In this paper, we introduce the practical method to determine the optimal illumination condition by evaluating the contaminative effect as a function of instrumental spot size, which is directly linked with electron current density.

Assessment of Microbial and Radioactive Contaminations in Korean Cold Duck Meats and Electron-Beam Application for Quality Improvement

  • An, Kyung-A;Jo, Yunhee;Arshad, Muhammad Sajid;Kim, Gui-Ran;Jo, Cheorun;Kwon, Joong-Ho
    • Food Science of Animal Resources
    • /
    • 제37권2호
    • /
    • pp.297-304
    • /
    • 2017
  • Animal-origin food products pose serious threat to public food safety due to high microbial loads. The microbial and radioactive contaminations in commercial cold duck meat products were evaluated. Ten different lots of commercial samples ($C_1-C_{10}$) were classified based on type and smoking process. All samples were highly contaminated (< 4-7 Log CFU/g) with total aerobic bacteria (TAB), yeasts and molds (Y&M), and 7 samples ($C_1-C_7$) were positive for coliforms. Furthermore, three samples were contaminated with Listeria monocytogenes ($C_4-C_6$) and one with Salmonella typhimurium ($C_6$). No radionuclides ($^{131}I$, $^{137}Cs$, and $^{134}Cs$) were detected in any sample. The results of DEFT (direct epifluorescent filter technique)/APC (aerobic plate count), employed to screen pre-pasteurization treatments of products, indicated that smoked samples were positive showing DEFT/APC ratios higher than 4. Notably, the samples showed a serious threat to microbial safety, thus were irradiated with electron-beam (e-beam). The $D_{10}$ values for S. typhimurium and L. monocytogenes were 0.65 and 0.42 kGy, respectively. E-beam application at 3 and 7 kGy resulted in reduction of initial TAB, Y&M, and coliform populations by 3 and 6 log cycles, respectively. Thus, e-beam was proven to be a good decontamination approach to improve the hygiene of cold duck meat.

The effect of contamination of the etched matal retainer on resin bonding strength (금속 유지장치의 오염이 레진 접착 결합력에 미치는 영향)

  • Park, Ha-Ok;Bang, Mong-Sook
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제18권3호
    • /
    • pp.217-224
    • /
    • 2002
  • The purpose of this study was to evaluate the influence of saliva contamination on the resin bonding of the etched metal retainers. The test samples were made of Verabond, and divided into 3 groups. Retainers in group1 had normally etched metal surfaces. Retainers in group2 had normally etched metal surfaces which were saliva-contaminated for 30 seconds and cleaned with streaming, luke-warm for 1 minute and dried thoroughly. Retainers in group3 had normally etched metal surfaces which were saliva- contaminated for 30 seconds and dried thoroughly without water-cleansing. Each 3 group specimen was watched on SEM. A resin core, 5mm in diameter and 6mm in length, was made of Panavia using Teflon mold on the each specimen. These 3 groups were tested to evaluate shear bond strength, using universal testing machine. The results were as follows : 1. The shear bond strength showed no significant difference between group1 and group2. 2. The shear bond strength showed significant difference between group1 and group3. 3. The shear bond strength significant difference between group2 and group3. 4. Scanning electron microscope photographs of group1 and group2 showed no signs of contamination but of group3 showed somewhat contaminated.

Heterotrophic Bacterial Growth on Hoses in a Neonatal Water Distribution System

  • Buffet-Bataillon, Sylvie;Bonnaure-Mallet, Martine;De La Pintiere, Armelle;Defawe, Guy;Gautier-Lerestif, Anne Lise;Fauveau, Severine;Minet, Jacques
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권4호
    • /
    • pp.779-781
    • /
    • 2010
  • After preliminary tests indicated an increased number of heterotrophic bacteria, we investigated possible sources of contamination in a neonatal intensive care unit (NICU) water distribution system. Scanning electron microscopic examination of flexible metallic hoses associated with the system revealed the presence of a biofilm; partial 16S rDNA sequencing revealed that the biofilm contained Blastomonas natatoria. Purgation of the water system three times a day, reinforced faucet cleaning, decreasing the cold water temperature to $12^{\circ}C$, and six repeated chlorinations at concentrations as high as 2 mg/l were not sufficient to eradicate the bacterial contamination. Replacing all of the rubber-interior flexible metallic hoses with teflon-lined hoses, followed by heating the water to $70^{\circ}C$, successfully controlled the bacteria.

Contamination of the 6MV Linear Accelerator Photon Beam by Electrons (6MV 전자 선형 가속기 광자선의 전자오염)

  • Yoo, Meong-Jin;Kim, Dong-Won;Chung, Woon-Hyuk
    • Journal of Radiation Protection and Research
    • /
    • 제13권1호
    • /
    • pp.21-30
    • /
    • 1988
  • The 6 MV photon beam of a linear accelerator (Mevatron 67) was studied for electron contamination. The surface dose, attributable almost entirely to contamination electrons, has a linear dependence on field width for square fields and an inverse square dependence on distance from the bottom of the fixed head assembly. Build-up and surface dose measurements were taken with and without an acrylic blocking tray in place. Further measurements were made with a copper filter designed to reduce secondary electrons emitted by photon interactions with the acrylic tray. The results are discussed in relation to skin sparing effect for radiation therapy patients. To achieve the maximum skin sparing effect, the selection of the optimum SSD and TSD is needed.

  • PDF

Effect of Blood Contamination on Vickers Microhardness and Surface Morphology of Mineral Trioxide Aggregate

  • Jaehyun Seung;Seong-Jin Shin;Byounghwa Kim;Ji-Myung Bae;Jiyoung Ra
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제51권2호
    • /
    • pp.165-175
    • /
    • 2024
  • This study aimed to investigate the effects of blood contamination on the Vickers hardness and the surface morphology of premixed MTA and compare them with the effects on conventional MTA. The Vickers microhardness of Endocem MTA Premixed Regular (EP) and ProRoot MTA (PM) was assessed after immersion in fetal bovine serum (FBS) and saline. Stem cells from human exfoliated deciduous teeth (SHED) were seeded on MTA after immersion in FBS, saline, and deionized water (DW). Cell adhesion patterns and surface morphology were visualized via scanning electron microscopy (SEM). The surface microhardness of EP and PM in FBS was lower than in saline. However, short-term exposure of PM to FBS did not reduce the microhardness compared to saline. Angular crystals formed in water, while rounded crystals with more air voids appeared in FBS. Favorable SHED attachment occurred in all groups. Overall, the surface hardness of EP and PM decreased after FBS exposure, although PM was less influenced. We suggest minimizing the amount of bleeding when using MTA clinically; nevertheless, PM remains an option with more expected blood contamination than EP. In summary, exposure to FBS decreased mechanical performance but allowed cell adhesion for both MTAs, with PM being more resistant to these changes.

Fabrication Method of High-density and High-uniformity Solder Bump without Copper Cross-contamination in Si-LSI Laboratory (실리콘 실험실에 구리 오염을 방지 할 수 있는 고밀도/고균일의 Solder Bump 형성방법)

  • 김성진;주철원;박성수;백규하;이희태;송민규
    • Journal of the Microelectronics and Packaging Society
    • /
    • 제7권4호
    • /
    • pp.23-29
    • /
    • 2000
  • We demonstrate the fabrication method of high-density and high-quality solder bump solving a copper (Cu) cross-contamination in Si-LSI laboratory. The Cu cross-contamination is solved by separating solder-bump process by two steps. Former is via-formation process excluding Cu/Ti under ball metallurgy (UBM) layer sputtering in Si-LSI laboratory. Latter is electroplating process including Ti-adhesion and Cu-seed layers sputtering out of Si-LSI laboratory. Thick photoresist (PR) is achieved by a multiple coating method. After TiW/Al-electrode sputtering for electroplating and via formation in Si-LSI laboratory, Cu/Ti UBM layer is sputtered on sample. The Cu-seed layer on the PR is etched during Cu-electroplating with low-electroplating rate due to a difference in resistance of UBM layer between via bottom and PR. Therefore Cu-buffer layer can be electroplated selectively at the via bottom. After etching the Ti-adhesion layer on the PR, Sn/Pb solder layer with a composition of 60/40 is electroplated using a tin-lead electroplating bath with a metal stoichiometry of 60/40 (weight percent ratio). Scanning electron microscope image shows that the fabricated solder bump is high-uniformity and high-quality as well as symmetric mushroom shape. The solder bumps with even 40/60 $\mu\textrm{m}$ in diameter/pitch do not touch during electroplating and reflow procedures. The solder-bump process of high-uniformity and high-density with the Cu cross-contamination free in Si-LSI laboratory will be effective for electronic microwave application.

  • PDF

Laboratory-scale Microcosm Studies in Assessing Enhanced Bioremediation Potential of BTEX and MTBE under Various Electron Acceptors in Contaminated Soil

  • 오인석;이시진;장순웅
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.368-371
    • /
    • 2003
  • Accidental release of petroleum products from underground storage tank(USTs) is one of the most common causes of groundwater contamination. BTEX is the major components of fuel oils, which are hazardous substances regulated by many nations. In addition to BTEX, other gasoline consituents such as MTBE(methyl-t-buthyl ether), anphthalene are also toxic to humans. Natual attenuation processes include physic, chemical, and biological trasformation. Aerobic and anaerobic biodegradation are believed to be the major processes that account for both containment of the petroleum-hydrocarbon plum and reduction of the contaminant concentrations. Aerobic bioremediation has been highly effective in the remediation of many fuel releases. However, Bioremediation of aromatic hydrocarbons in groundwater and sediments is ofen limited by the inability to provide sufficient oxygen to the contaminated zones due to the low water solubility of oxygen. Anaerobic processes refer to a variety of biodegradation mechanisms that use nitrate, ferric iron, sulfate, and carbon dioxide as terminal electron accepters. The objectives of this study was to conduct laboratory-scale microcosm studies in assessing enhanced bioremediation potential of BTEX and MTBE under various electron accepters(aerobic, nitrate, ferric iron, sulfate) in contaminated Soil. these results suggest that, presents evidence and a variety pattern of the biological removal of aromatic compounds under enhanced nitrate-, Fe(III)-, sulfate-reducing conditions.

  • PDF

Effect of Blood Contamination on the Push-Out Bond Strength and Surface Morphology of Tricalcium Silicate Materials (혈액오염이 Tricalcium Silicate 재료의 압출강도와 표면형태에 미치는 영향)

  • Park, Misun;Kim, Jaehwan;Choi, Namki;Kim, Seonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제43권1호
    • /
    • pp.36-43
    • /
    • 2016
  • The aim of this study was to evaluate the effect of blood contamination on the push-out bond strength and surface morphology of tricalcium silicate materials; Biodentine$^{(R)}$, Theracal$^{(R)}$ and mineral trioxide aggregate. The standardized lumens of root slices prepared from extracted single-root human teeth were filled with Biodentine$^{(R)}$, Theracal$^{(R)}$ and mineral trioxide aggregate by manufacturer's instruction. The specimens were randomly divided into 2 groups (n = 20) for each material and then incubated for 4 days at $37^{\circ}C$; control group (phosphate buffered saline solution) and experimental group (fetal bovine serum). The push-out bond strengths were then measured by a universal testing machine and the surface morphology of each experimental group was analyzed by scanning electron microscope. Biodentine$^{(R)}$ and Theracal$^{(R)}$ showed higher push-out bond strength compared with mineral trioxide aggregate after exposure to fetal bovine serum. A substantial change in the surface morphology of each material was observed after exposure to fetal bovine serum. In conclusion, the push-out bond strengths of Biodentine$^{(R)}$ and Theracal$^{(R)}$ were higher than mineral trioxide aggregate when exposed to blood contamination. Therefore, it is supposed that the use of Biodentine$^{(R)}$ and Theracal$^{(R)}$ is appropriate in the presence of blood.