• Title/Summary/Keyword: Electron accelerator

Search Result 253, Processing Time 0.053 seconds

Preliminary Radiological Considerations for X-ray Free Electron Laser Project at PAL

  • Lee, Hee-Seock;Hong, Suk-Mo;Kim, Min-Ho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.1190-1191
    • /
    • 2004
  • New $4^{th}$ generation synchrotron facility, XFEL, is almost similar to previous $3^{rd}$ generation synchrotron facility in the view of radiological aspects and most important positions are a dump and synchrotron radiation beam line. In this paper, tile radiation protection solutions for them and undulator are suggested and discussed.

  • PDF

Angle-Resolved Photoemission Spectroscopy: Momentum-Space Microscope

  • Hwang, Chan-Cuk
    • Applied Microscopy
    • /
    • v.45 no.3
    • /
    • pp.115-118
    • /
    • 2015
  • In this review paper, I'd like to introduce the basics of angle-resolved photoemission spectroscopy (ARPES) and some of my results taken at the Pohang Accelerator Laboratory (PAL), the only synchrotron radiation in South Korea. The results show that ARPES is very useful, in particular, for studying two-dimensional materials. It looks like a microscope in momentum space similar to transmission electron microscope imaging atoms in real space.

Conceptual design of hybrid target for molybdenum-99 production based on heavywater

  • Ali Torkamani ;Ali Taghibi Khotbehsara ;Faezeh Rahmani ;Alexander Khelvas ;Alexander Bugaev ;Farshad Ghasemi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1863-1870
    • /
    • 2023
  • Molybdenum-99 (99Mo) is used for preparing Technetium-99 m (99mTc), which is the most widely used isotope in nuclear medicine. In this work, a study for 99Mo production based on a high-power electron accelerator has been performed as an alternative approach to produce 99mTc. In this study, Monte Carlo MCNPX2.6 code has been used to examine a novel idea of simultaneous hybrid production of 99Mo via both photoneutron and neutron capture reactions using an electron accelerator in heavy water tank. It is expected that this conceptual design including an arrangement of metallic plates of 100Mo and 98Mo produces total activity of 97.5 Ci at the end of 20-h continuous e-beam irradiation (30 MeV, 10 mA).

Phase identification of $C_3N_4$ in CN films prepared by rf plasma chemical vapor deposition and dc magnetron sputtering

  • Fu, Dejun;Wu, Dawei;Zhang, Zhihong;Meng, Xianquan;He, Mengbing;Guo, Huaixi;Peng, Yougui;Fan, Xiangjun
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.s1
    • /
    • pp.140-148
    • /
    • 1998
  • We prepared $C_3N_4$ films by rf plasma enhanced chemical vapor deposition(PCVD) and alternating $C_3N_4$/TiN composite films by dc magnetron sputtering. X-ray diffraction (XRD) and transmission electron diffraction (TED) revealed that the structure of the films is amorphous or polycrystalline, depending on deposition conditions and heat treatment. X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared (FTIR) spectroscopy confirmed the presence of $sp_3\; and sp _2$ hybridized C atoms bonded with N atoms in the tetrahedral and hexagonal configurations, respectively. Graphite-free $C_3N_4$ films were obtained by PCVD under optimal conditions. To prepare well crystallized $C_3N_4$ films by magnetron sputtering, we introduced negatively biased gratings in the sputtering system. CN films deposited at grating voltages (Vg) lower than 400V are amorphous. Crystallites of cubic and $\beta$-$C_3N_4$ were formed at increased voltages.

  • PDF

Chemisorption and orientation of Selenopheneon Si(100)-$2{\times}1$

  • Lee, Han-Koo;Kim, Ki-Jeong;Kim, Hyeong-Do;Shin, Hyun-Joon;Kim, Bong-Soo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.372-372
    • /
    • 2010
  • We have investigated adsorption of selenophene on Si(100) at room temperature using high resolution photoemission spectroscopy (HRPES) and near edge X-ray absorption fine structure (NEXAFS) in the partial electron yield (PEY) mode. The Si 2p, C 1s, Se 3d spectra of selenophene on Si(100) show that selenophene is nondissociatively chemisorbed on Si(100)-$2{\times}1$ through [2+2] cycloaddition. NEXAFS has been conducted to characterize the adsorption geometry of selenophene on Si(100). Since the $\pi^*$ orbital of C=C bond show good angular dependence in carbon K-edge NEXAFS spectra, the angle $53{\pm}5^{\circ}$ determined from NEXAFS spectra. This majority structure is consistent with the [2+2] cycloaddition of selenophene to the dimer of the Si(100)-$2{\times}1$ surface.

  • PDF

A Study on Photon Characteristics Generated from Target of Electron Linear Accelerator for Container Security Inspection using MCNP6 Code (MCNP6 코드를 이용한 컨테이너 보안 검색용 전자 선형가속기 표적에서 발생한 광자 평가에 관한 연구)

  • Lee, Chang-Ho;Kim, Jang-Oh;Lee, Yoon-Ji;Jeon, Chan-hee;Lee, Ji-Eun;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.193-201
    • /
    • 2020
  • The purpose of this study is to evaluate the photon characteristics according to the material and thickness of the electrons incidented through a linear accelerator. The computer simulation design is a linear accelerator target consisting of a 2 mm thick tungsten single material and a 1.8 mm and 2.3 mm thick tungsten and copper composite material. In the research method, First, the behavior of primary particles in the target was evaluated by electron fluence and electron energy deposition. Second, photons occurring within the target were evaluated by photon fluence. Finally, the photon angle-energy distribution at a distance of 1 m from the target was evaluated by photon fluence. As a result, first, electrons, which are primary particles, were not released out of the target for electron fluence and energy deposition in the target of a single material and a composite material. Then, electrons were linearly attenuated negatively according to the target thickness. Second, it was found that the composite material target had a higher photon generation than the single material target. This confirmed that the material composition and thickness influences photon production. Finally, photon fluence according to the angular distribution required for shielding analysis was calculated. These results confirmed that the photon generation rate differed depending on the material and thickness of the linear accelerator target. Therefore, this study is necessary for designing and operating a linear accelerator use facility for container security screening that is being introduced in the country. In addition, it is thought that it can be used as basic data for radiation protection.

Electron Beam -Induced Graft Polymerization of Acrylic Acid on Polypropylene Nonwoven Fabrics(II) (전자빔 가속기를 이용한 폴리프로필렌섬유의 개질(II) - 전자빔의 흡수선량 및 중합조건이 그라프트 공중합에 치는 영향 -)

  • ;N.I. Shtanko
    • Textile Coloration and Finishing
    • /
    • v.15 no.3
    • /
    • pp.154-160
    • /
    • 2003
  • Polypropylene nonwoven fabrics were grafted with acrylic acid by a preirradiation method by using electron beam accelerator. The effect of irradiation dose, storage time, concentration of acrylic acid, reaction temperature, reaction time and Mohr's salt concentration on the degree of grafting were investigated in detail. The grafted Polypropylene nonwoven fabrics were characterized using IR spectroscopy and SEM. The results showed that the degree of grafting increased with increasing absorbed dose and the Mohr's salt in the acrylic acid solution promoted grafting efficiency.

6MV Photon Beam Commissioning in Varian 2300C/D with BEAM/EGS4 Monte Carlo Code

  • Kim, Sangroh;Jason W. Sohn;Cho, Byung-Chul;Suh, Tae-Suk;Choe, Bo-Yong;Lee, Hyoung-Koo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.113-115
    • /
    • 2002
  • The Monte Carlo simulation method is a numerical solution to a problem that models objects interacting with other objects or their environment based upon simple object-object or object-environment relationships. In spite of its great accuracy, It was turned away because of long calculation time to simulate a model. But, it is used to simulate a linear accelerator frequently with the advance of computer technology. To simulate linear accelerator in Monte Carlo simulations, there are many parameters needed to input to Monte Carlo code. These data can be supported by a linear accelerator manufacturer. Although the model of a linear accelerator is the same, a different characteristic property can be found. Thus, we performed a commissioning process of 6MV photon beam in Varian 2300C/D model with BEAM/EGS4 Monte Carlo code. The head geometry data were put into BEAM/EGS4 data. The mean energy and energy spread of the electron beam incident on the target were varied to match Monte Carlo simulations to measurements. TLDs (thermoluminescent dosimeter) and radiochromic films were employed to measure the absorbed dose in a water phantom. Beam profile was obtained in 40cm${\times}$40cm field size and Depth dose was in 10cm${\times}$10cm. At first, we compared the depth dose between measurements and Monte Carlo simulations varying the mean energy of an incident electron beam. Then, we compared the beam profile with adjusting the beam radius of the incident electron beam in Monte Carlo simulation. The results were found that the optimal mean energy was 6MV and beam radius of 0.1mm was well matched to measurements.

  • PDF

Calculation of Energy Spectra for 6 MeV Electron Beam of LINAC Using MCNPX (MCNPX를 이용한 선형가속기의 6 MeV 전자선에 대한 에너지분포 계산)

  • Lee, Jeong-Ok;Jeong, Dong-Hyeok
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.224-231
    • /
    • 2006
  • The electron energy spectra for 6 MeV electron beam were calculated using a MCNPX code. The head of the linear accelerator (ML6M; Mitsubishi, Japan) was modelled for this study. The energy spectrum of the initial electron beam was assumed to be Gaussian and the mean energy was determined by evaluating the measured and calculated values of $R_{50}$ and dose profiles in air. The energy distributions for electrons and photons at the interested points in the head of the linear accelerator were calculated by appling the Initial beam parameters. The effect of contaminant photons on depth dose curves were estimated by the photon energy spectra at the end of the applicator.

  • PDF