• 제목/요약/키워드: Electron Dose Rate

검색결과 130건 처리시간 0.029초

전기방사된 나일론66 나노웹의 열적·기계적 특성에 전자선 조사가 미치는 영향 (The Effects of Electron Beam Irradiation on Thermal and Mechanical Properties of Electrospun Nylon 66 Nano-web)

  • 전준표;강효경;강필현
    • 방사선산업학회지
    • /
    • 제5권1호
    • /
    • pp.69-73
    • /
    • 2011
  • Polyamide 66 (PA66) nanofibers with Triallyl cyanurate (TAC) were obtained by electrospinning of formic acid and chloroform solution. Electron beam irradiation of PA66 nanofiber with and without TAC was carried out over a range of absorbed doses (20~100 kGy) in nitrogen. The characterization of the irradiated PA66 nanofibers and PA66 nanofibers with TAC was done by scanning electron microscopy (SEM), nuclear magnetic resonance (NMR), thermogravimetric analysis (TGA) and universal testing machine (UTM). The results of the SEM image analysis confirmed that the morphology of PA66 nanofibers was not altered by electron beam. The amount of TAC in PA66 nanofiber with TAC was identified by $^1H-NMR$ analysis. The degradation temperature of PA66 nanofibers with TAC at an absorbed dose of 20~100 kGy was higher than the irradiated PA66 nanofiber without TAC. On the other hand, the decreasing rate of modulus of irradiated PA66 nanofibers with TAC was less than PA66 nanofibers.

저선량 전자선 조사된 국내산 참다래의 이화학적 품질변화 (Physicochemical Changes of Electron Beam-Irradiated Korean Kiwifruits at Low Dose Levels)

  • 김경희;권종숙;이정옥;이병철;박성희;육홍선
    • 한국식품영양과학회지
    • /
    • 제36권5호
    • /
    • pp.603-608
    • /
    • 2007
  • 참다래에 0.3 및 0.6 kGy의 저선량 전자선 조사를 실시한 후 $20^{\circ}C$, 4주간 저장하면서 0, 1, 2, 3 및 4주차에 항산화 활성과 이화학적 품질변화에 미치는 영향을 조사하였다. 수소공여능, pH는 조사에 의한 변화는 없었으며, 비타민 C 함량은 조사구에서 높게 나타났다. 당 함량은 저장기간 동안 후숙이 진행되면서 증가하였으나 조사에 의한 유의차는 나타내지 않았다. 가용성 고형물 함량은 조사구에서 저장초기에 높았으나 저장기간에 따른 증가폭은 적었다. 유기산의 경우 저장 초기에 조사에 의한 변화가 적으면서 조사한 참다래의 경우 저장기간 동안 유기산 함량의 감소폭이 적게 나타났다. 따라서 참다래에 대한 0.6 kGy까지의 전자선 조사는 약간의 후숙 지연 효과를 가지면서 항산화 활성 및 이화학적 품질에는 영향을 미치지 않는 것으로 사료되었다.

Aflatoxin $B_1$이 계배 간조직의 미세구조에 미치는 영향 (The Effect of the Aflatoxin $B_1$ on Liver Tissue of Chick-Embryo)

  • 조자향;전향미;서숙재
    • Applied Microscopy
    • /
    • 제26권2호
    • /
    • pp.123-136
    • /
    • 1996
  • To investigate the effect of aflatoxin $B_1$, on survival rate and ultrastructure of liver during chick embryogenesis electron microscopic methods were used. After injection of aflatoxin $B_1$ into the yolk, ultrastructural changes in the liver of chicken embryo were observed. The results were as followed. 1. 12-day old chicken embryos were treated with single injection of aflatoxin $B_1$ with the dose of $0.0005{\mu}g,\;0.005{\mu}g,\;0.05{\mu}g,\;0.5{\mu}g,\;2.5{\mu}g,\;5.0{\mu}g$ each. Chicken embryos treated with the dose of $0.5{\mu}g$ of aflatoxin $B_1$ had survival rate of 22%. The embryos treated with $2.5{\mu}g$ of aflatoxin $B_1$ hardly survived. 2. Chicken embryos treated with $0.05{\mu}g$ of afatoxin $B_1$ had hatched in 30%, but once hatched, they all survived. 3. After administration of $0.05{\mu}g$ of aflatoxin $B_1$ into the 12-day old chicken embryo, the electron microscopic studies were examined during development stages. The nuclei of hapatocytes became irregularly shaped and the structures of endoplasmic reticulum were changed to spherical types at 20-day old chicken embryo. Also, mitochondria became to be dilated and severe fibrosis was induced in the cytoplasm. However, the hepatocytes became almost normal in 30-day old young chicken.

  • PDF

DESIGN OPTIMIZATION OF RADIATION SHIELDING STRUCTURE FOR LEAD SLOWING-DOWN SPECTROMETER SYSTEM

  • KIM, JEONG DONG;AHN, SANGJOON;LEE, YONG DEOK;PARK, CHANG JE
    • Nuclear Engineering and Technology
    • /
    • 제47권3호
    • /
    • pp.380-387
    • /
    • 2015
  • A lead slowing-down spectrometer (LSDS) system is a promising nondestructive assay technique that enables a quantitative measurement of the isotopic contents of major fissile isotopes in spent nuclear fuel and its pyroprocessing counterparts, such as $^{235}U$, $^{239}Pu$, $^{241}Pu$, and, potentially, minor actinides. The LSDS system currently under development at the Korea Atomic Energy Research Institute (Daejeon, Korea) is planned to utilize a high-flux ($>10^{12}n/cm^2{\cdot}s$) neutron source comprised of a high-energy (30 MeV)/high-current (~2 A) electron beam and a heavy metal target, which results in a very intense and complex radiation field for the facility, thus demanding structural shielding to guarantee the safety. Optimization of the structural shielding design was conducted using MCNPX for neutron dose rate evaluation of several representative hypothetical designs. In order to satisfy the construction cost and neutron attenuation capability of the facility, while simultaneously achieving the aimed dose rate limit (< $0.06{\mu}Sv/h$), a few shielding materials [high-density polyethylene (HDPE)eBorax, $B_4C$, and $Li_2CO_3$] were considered for the main neutron absorber layer, which is encapsulated within the double-sided concrete wall. The MCNP simulation indicated that HDPE-Borax is the most efficient among the aforementioned candidate materials, and the combined thickness of the shielding layers should exceed 100 cm to satisfy the dose limit on the outside surface of the shielding wall of the facility when limiting the thickness of the HDPE-Borax intermediate layer to below 5 cm. However, the shielding wall must include the instrumentation and installation holes for the LSDS system. The radiation leakage through the holes was substantially mitigated by adopting a zigzag-shape with concrete covers on both sides. The suggested optimized design of the shielding structure satisfies the dose rate limit and can be used for the construction of a facility in the near future.

PET/CT실에서 사용되는 주사기 차폐체의 산란선 측정 (Scattering Measurement of Syringe Shield Used in PET/CT)

  • 장동근;박철우;박은태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.375-382
    • /
    • 2020
  • PET/CT is a medical equipment that detects 0.511 MeV of gamma rays. The radiation workers are inevitably exposed to ionizing radiation in the process of handling the isotope. Accordingly, PET/CT workers use syringe shields made of lead and tungsten to protect their hands. However, lead and tungsten are known to generate very high scattering particles by interacting with gamma rays. Therefore, in this study, we tried to find out the effect on the scattering particles emitted from the syringe shield. In the experiment, first, the exposure dose to the hand (Rod phantom) was evaluated according to the metal material (lead, tungsten, iron, stainless steel) using Monte Carlo simulation. The exposure dose was compared according to whether or not plastic is attached. Second, the exposure dose of scattering particles was measured using a dosimeter and lead. As a result of the experiment, the shielding rate of plastics using the Monte Carlo simulation showed the largest difference in dose of about 40 % in lead, and the lowest in iron, about 15 %. As a result of the dosimeter test, when the plastic tape was wound on lead, it was found that the reduction rate was about 15 %, 28 %, and 39 % depending on the thickness. Based on the above results, it was found that 0.511 MeV of gamma ray interacts with the shielding tool to emit scattered rays and has a very large effect on radiation exposure. However, it was considered that the scattering particles could be sufficiently removed with plastics with a low atomic number. From now on, when using high-energy radiation, the shielding tool and the skin should not be in direct contact, and should be covered with a material with a low atomic number.

LID (Lyon Intraoperative Device) 이용한 수술중 방사선치료시 전자선의 선량분포 특성 (The dosimetric Properties of Electron Beam Using Lyon Intraoperative Device for Intraoperative Radiation Therapy)

  • 김계준;박경란;이종영;김희연;성기준;추성실
    • Radiation Oncology Journal
    • /
    • 제10권1호
    • /
    • pp.85-93
    • /
    • 1992
  • 수술중 방사선치료를 환자에 적용하기에 앞서 본원이 보유하고있는 LID를 이용한 전자선의 선량분포 특성을 연구하였다. 이러한 선량 특성에 대한 자료는 적절한 Cone의 모양이나 크기, 에너지를 결정하게하며 빠르고 정확한 계산을 위하여 필요하다. 따라서, 본 저자들은 3-Dimensional Water Phantom Dosimetry System를 이용하여 Cone의 크기, Cone의 모양, 보상필터 사용 유무에 따라 Cone의 출력인자, 조직표면선량, 선축상 최대치 지점, $90\%$의 깊이, 대칭도와 편평도, SSD 보상인자, 선량분포 등을 측정하여 다음과 같은 결과를 얻었다. 1) Cone의 출력인자는 Cone모양에 따라 각각 측정하였으며 Cone의 크기와 에너지가 작을수록 급격하게 감소하는 결과를 보였다. 2) 보상 필터의 하나인 Flattening Filter를 사용한 결과 포면 선량이 6 MeV, 9 MeV, 12 MeV에 대하여 각각 $85.3\%$, $89.2\%$, $93.4\%$였고, 이 보상 필터를 사용하므로 선량률과 beam의 투과율은 감소하지만 치료부위에 따라 beam의 모양을 변형시키며 특히, 표면선량을 $90\%$나 그 이상으로 증가시킬수 있었다. 3) 3차에 걸친 beam의 collimation과 보상 필터를 결합하여 사용한 결과 매우 좋은 beam의 균일성과 편평도 뿐만아니라 $90\%$ 등선량곡선 넓이가 커지는 결과를 보였다. 4) 치료를 위하여 중요한 간격인 SSD 100cm에서 SSD 110cm까지의 출력인자는 측정치와 계산치가 Cone의 크기와 모양, 에너지에 따라 $1\~3\%$의 차이를 보였다.

  • PDF

ESR dosimetry and Dating toward $21^{st}$ Century

  • Ikeya, Motoji
    • 한국자기공명학회논문지
    • /
    • 제6권2호
    • /
    • pp.84-88
    • /
    • 2002
  • Dating and dosimetry using electron spin resonance (ESR) in 20th Century developed at both Yamaguchi University and Osaka University have been reviewed with emphasis on new prospects and strategies in 21th century. Natural radiation have been generating radicals that accumulated in archaeological and geological materials. ESR detects these radicals and the ESR signal intensity is proportional to the radiation dose and therefore the age. The assessment of the total dose of natural radiation and the annual dose rate give their ESR ages. The ESR dating of stalactites and stalagmites ant Akiyoshi cave in Yamaguchi prefecture in 1975 was extended to anthropological dating using bones and tooth enamel excavated in Greek Petralona cave. Fossils of shells and corals gave the ages of marine terraces and sea-level changes. Quartz grains gave the ages of geothermal alteration and fault movements. Future ESR dating of ices at outer planets anf their satellite are also investigated as basic studies for ices od $H_2O,\;CO_2,\;SO_2$ as well as terrestrial hydrates in laboratory. Atomic bomb radiation dosimetry at Hiroshima and Nagasaki using ESR lead to the dosimetry of personnel, Chemobyl and JCO criticality accidents. Monitoring of radiation dose with sensitive materials with tissue equivalence are being developed. finally a new scanning ESR imaging apparatus (a near field microwave microscope) developed in our laboratory gave ESR images of Radicals from fossils to Si-CVD and diamond films as summarized in my book in 2002.

  • PDF

전자선 조사의 채소 종자 및 식물병원성 미생물에 대한 영향 (Effect of Electron Beam Irradiation on Selected Vegetable Seeds and Plant-Pathogenic Microorganisms)

  • 배영민
    • 생명과학회지
    • /
    • 제23권12호
    • /
    • pp.1415-1419
    • /
    • 2013
  • 본 연구에서는 식물병원성 미생물들인 잿빛곰팡이와 Agrobacterium rhizogenes의 전자선에 대한 감수성을 조사하였다. 그 결과, 2 kGy의 전자선량이 잿빛곰팡이의 분생포자 및 Agrobacterium rhizgenes의 세포를 사멸시키는 데에 충분한 것으로 나타났다. 식물 종자의 전자선에 대한 저항성을 조사해 본 결과, 대파, 열무와 오이 종자는 2 kGy의 전자선 조사에서도 발아율이 전혀 영향을 받지 않았고, 쑥갓 종자의 경우에는 발아율에 있어서 근소한 감소를 보였다. 그러나 고추와 상추의 경우에는 전자선 조사에 대해서 대단히 약한 것으로 나타났다. 결과적으로 열무, 오이, 대파 및 쑥갓 종자의 경우에는 식물병원성 미생물의 살균에 필요한 2 kGy의 전자선량을 조사함으로써 발아율에 큰 영향을 미치지 않고 충분한 살균효과를 거둘 수 있을 것으로 판단된다. 그러나 고추와 상추의 경우에는 전자선을 이용한 살균 방법은 사용하기 어려운 것으로 나타났다.

Customer Acceptance Procedure for Clinac (21EX-Platinum)

  • 홍동기;이우석;권경태;박광호;김정만
    • 대한방사선치료학회지
    • /
    • 제16권2호
    • /
    • pp.43-61
    • /
    • 2004
  • 목적 : 환자의 치료에 있어서 정확한 장비의 설치와 성능 평가는 치료의 질을 향상시키는데 중요한 요소라고 할 수 있으며 사용자가 장비의 특성과 사용 방법을 숙달하고 업무를 수행하는 것이 매우 중요하다고 생각한다. 그러므로 방사선 치료기를 설치하고 방사선 치료를 하기 전에 사용자가 직접 장비의 설치와 성능 평가에 참여하고 특성을 파악하여 이해하는 것이 필요하다. 본 연구에서는 CAP의 과정과 성능 평가결과를 소개하고자 한다. 대상 및 방법 : 선형가속기 21EX(varian, USA)를 대상으로 설치 시부터 성능 검사까지 전 과정을 평가하였고 성능평가는 크게 radiation survey, mechanical test, radiation isocenter test, beam performance, dosimetry, enhanced dynamic wedge로 구분하여 X-omat film(kodark), 선량 측정 장비(multidata, densitometer, electrometa)를 이용하여 실시하였다. 또한 선형가속기에 부착된 MLC(millenium, 120leaf)와 EPID(portal vision)의 성능 평가는 별도로 실시하였다. 결과 : Survey meter를 이용하여 측정한 leakage는 허용 범위 이하의 선량이 검출되었고 mechanical test에서 collimator, gantey, couch rotation은 1mm 이하였고 육안으로 평가한 angle은 digital이 ${\pm}1^{\circ}$이내에 mechanical은 ${\pm}5^{\circ}$이내였다. 또한 light field와 cross-hair의 직선성 검사도 1mm이내로 평가되었다. (A)symmetrical jaw field는 upper/lower 모두 ${\pm}0.5mm$이내였다. X-omat film을 이용한 radiation isocenter test는 1mm 이하였고 light field와 radiation field 의 일치성 검사는 ${\pm}1mm$ 이내였으며 선량 측정 장비를 이용하여 측정한 $\%DD$는 photon energy는 모두 ${\pm}1\%$ 이내로 electron energy는 $90\%,\;80\%,\;50\%,\;30\%$를 측정한 결과 허용 범위 내에서 평가되었다. photon 과 electron energy의 flateness는 각각 $2.3\%$(기준 $3\%$)이내, $3\%$(기준 $4.5\%$)이내이고 symmetry는 $0.45\%$(기준 $2\%$), $0.3\%$(기준 $2\%$)이내에서 평가 할 수 있었다. 그리고 dosimetry test는 sort term, MU setting, rep rate, dose rate accuracy를 photon과 electron energy 별로 MU와 gantry angle을 바꿔가면서 측정한 결과 허용범위 오차이내에 포함되는 것을 확인 할 수 있었다. EPID(portal vision)의 Exact-Arm의 기계적인 검사는 vertical, lateral, longitudinal은 허용범위 내에서 동작했으며 명암과 해상도 검사도 05.mm의 니크롬선이 선명하게 나타났으며 phantom의 음영도 뚜렷하게 나타났다. Multileaf collimator(MLC)검사는 leaf이 isocenter의 중심에 정확하게 배열되었으며 재현성 검사도 정상적으로 동작하였다. 결론 : Clinac 21EX 장치의 customer acceptance를 통해서 향후의 환자의 치료를 하는데 있어 장치의 안정성을 확인 할 수 있었으며 치료 전의 선형가속기와 주변장치의 특성을 파악 할 수 있어서 장비 사용에 있어서 어려움을 감소시킬 수 있으리라고 생각된다. 또한 사용자가 적극적으로 참여함으로써 앞으로 환자를 치료하는데 있어서도 많은 도움이 되리라 생각한다.

  • PDF

전자스핀공명을 이용한 저밀도 폴리에틸렌의 방사선 열화 검지 (Detection of Radiation Degradation of LDPE by ESR Spectroscopy)

  • 김기엽;이청;류부형
    • 한국안전학회지
    • /
    • 제20권1호
    • /
    • pp.81-86
    • /
    • 2005
  • This study has investigated radiation degradation of low density polyethylene(LDPE). Samples were irradiated up to 800kGy using a $Co^{60}\;\gamma-ray$ at a dose rate of 5kGy/hr in the presence of air atmosphere at room temperature. After irradiation, storing for 2 weeks, free radical measurement of LDPE has established by electron spin resonance(ESR). ESR measurement showed that free radical concentration(FRC) was increased with radiation dose and decreased with the time. The radical types showed alkyl, allyl, and peroxy radical with the irradiation, these changed to peroxy radical with the time.