• 제목/요약/키워드: Electromagnetic therapy

Search Result 74, Processing Time 0.027 seconds

Clinical Observations of Complex Therapy, including Electroacupuncture and Magnetic-acupuncture, for Treating Peripheral Facial Nerve Palsy (전기와 자기장의 침 자극을 포함한 복합치료가 말초성 안면신경마비에 미치는 영향에 대한 관찰 연구)

  • Oh, Seo Young;Lee, Hyun;Kang, Jae Hui
    • Journal of Acupuncture Research
    • /
    • v.33 no.3
    • /
    • pp.117-127
    • /
    • 2016
  • Objectives : This study was performed to observe the effect of complex therapy, including electro-acupuncture and magnetic-acupuncture, on peripheral facial nerve palsy. Methods : Nine patients with peripheral facial nerve palsy were treated with acupuncture using electrical and magnetic stimulation. Acupoints in the face were stimulated with an electromagnetic field, as widely and as evenly as possible. To evaluate the effects before and after treatment we used Yanagihara's unweighted grading system, House-Brackmann scale, and Sunnybrook facial grading system and image once a week. Results : After treatment, the scores of Yanagihara's unweighted grading system, House-Brackmann scale and Sunnybrook facial grading system each improved (p-value < 0.05). Conclusion : Complex therapy using electro-acupuncture and magnetic-acupuncture might be an effective treatment to improve symptoms of peripheral facial nerve palsy. Further randomized-controlled trials are required to verify the efficacy and results of this study.

Comparison of Multifidus Muscle Activity and Pelvic Tilting Angle During Typing in Nonspecific Lower Back Pain Subjects with and without Visual Biofeedback

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.1
    • /
    • pp.47-52
    • /
    • 2021
  • Purpose: Biofeedback using various ways has helped correct the sitting posture. This study compared the multifidus muscle activity, pelvic and 2nd sacrum tilting angle during typing in nonspecific lower back pain (NCLBP) subjects with and without visual biofeedback. Methods: Thirty subjects with NCLBP were enrolled in this study. An electromyography device was used to measure the multifidus muscle activity. An electromagnetic tracking motion device was used to measure the pelvic and 2nd sacrum tilting angle. The multifidus muscle activity, pelvic, and 2nd sacrum tilting angle were measured before and after typing for 30 minutes in the sitting position. An independent t-test was used to compare the changing values for 30 minutes between the group with and without visual biofeedback. Results: The changing values of the multifidus muscle activity, pelvic, and 2nd sacrum tilting angle were significantly smaller in the group with visual biofeedback than the group without visual biofeedback (p<0.05). Conclusions: In subjects with NCLBP, the visual biofeedback can be recommended to maintain the multifidus muscle activity, pelvic, and 2nd sacrum tilting angle during typing for 30 minutes.

One Case of Facial Nerve Palsy in Herpes Zoster Oticus Treated with electromagnetic therapy stimulator(Whata153) (자기장과 전기 조합 자극기(Whata 153)를 이용한 이성대상포진 안면신경마비 치료 1례 보고)

  • Jo, Seong-Eun;Lee, Hyun
    • Journal of Haehwa Medicine
    • /
    • v.25 no.1
    • /
    • pp.53-62
    • /
    • 2016
  • Objectives : The purpose of this study was to report a case of a patient efficacy of electromagnetic acupuncture using Whata 153 in facial nerve palsy in Herpes zoster oticus. Methods : We treated the patient with magnetic acupuncture combined with electro-acupuncture. Acupuncture points were at the face (BL2, GB14, TE23, ST4, ST6, ST3). All the acupuncture points were stimulated with magnetic field and 4 of them were combined with electro-acupuncture. Results & Conclusions : The improvement of facial movement and symptom was evaluated by Yanagihara grading system(Y-system), House-Brackmann scale(HB scale) and Sunnybrook facial grading system(SFGS). After treatment, all of the scales(Y-system, HB scale and SFGS) and symptom of the patient were improved. From the above results, we suggest that magnetic acupuncture and electro-acupuncture might be effective on facial nerve palsy in Herpes zoster oticus.

Response Properties of Meridians for focused variable electromagnetic stimulus (접속형 가변 전자계 자극에 대한 경락반응특성)

  • Lee, Gyoun-Jung;Cho, Dong-Guk;Kim, Soo-Byung;Kwon, Sun-Min;Shin, Tae-Min;Lee, Kyoung-Joung;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1399-1410
    • /
    • 2009
  • It is a method to treat pain using medication, neurotomy, and surgery. And acupuncture, ultrasound, electric treatment, and magnetic treatment are applied as a alternative physiotherapy. Electronic therapy is useful but it can be affected by impedance of skin or subcutaneous tissue. So, percutaneous stimulation is leading therapy, that is very randomly. We developed the system which can stimulate parts of acupuncture point noninvasively using the focused magnetic field. And we designed the magnetic stimulation electrode which is considered efficiency of the magnetic stimulation. It can make similar stimulation with manual acupuncture. To confirm the availability and reliability we compared Meridian Electronic Potential(MEP) change between manual acupuncture and magnetic stimulation. From this result, we found out the MEP changes of manual acupuncture and magnetic stimulation were similar. And there were various response properties as changes of stimulation method, intensity, and frequency. Also, the MEP change can be induced by electromagnetic stimulation. We confirmed that it is possible to use electromagnetic stimulation as a acupoint stimulation or pain treatment instrument.

Effect of Pulsed Electromagnetic Field on MMP-9 and TIMP-1 Levels in Chondrosarcoma Cells Stimulated with IL-1β

  • Caliskan, Serife Gokce;Bilgin, Mehmet Dincer;Kozaci, Leyla Didem
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.7
    • /
    • pp.2701-2705
    • /
    • 2015
  • Chondrosarcoma, the second most common type of bone malignancy, is characterized by distant metastasis and local invasion. Previous studies have shown that treatment by pulsed electromagnetic field (PEMF) has beneficial effects on various cancer cells. In this study, we investigated the effects of PEMF applied for 3 and 7 days on the matrix metalloproteinase (MMP) levels in chondrosarcoma SW1353 cells stimulated with two different doses of $IL-1{\beta}$. SW1353 cells were treated with (0.5 and 5 ng/ml) $IL-1{\beta}$ and PEMF exposure was applied either 3 or 7 days. MMP-9 and TIMP-1 levels were measured in conditioned media by enzyme-linked immunosorbent assay. The results were relative to protein levels. Statistical analyses were performed using one-way analysis of variance (ANOVA). P<0.05 was considered significant. PEMF treatment significantly decreased MMP-9 protein levels in human chondrosarcoma cells stimulated with 0.5 ng/ml $IL-1{\beta}$ at day 7, whereas it did not show any effect on cells stimulated with 5 ng/ml $IL-1{\beta}$. There was no significant change in TIMP-1 protein levels either by $IL-1{\beta}$ stimulation or by PEMF treatment. The results of this study showed that PEMF treatment suppressed $IL-1{\beta}$-mediated upregulation of MMP-9 protein levels in a dual effect manner. This finding may offer new perspectives in the therapy of bone cancer.

Pulsed electromagnetic field potentiates etoposide-induced MCF-7 cell death

  • Woo, Sung-Hun;Kim, Bohee;Kim, Sung Hoon;Jung, Byung Chul;Lee, Yongheum;Kim, Yoon Suk
    • BMB Reports
    • /
    • v.55 no.3
    • /
    • pp.148-153
    • /
    • 2022
  • Etoposide is a chemotherapeutic medication used to treat various types of cancer, including breast cancer. It is established that pulsed electromagnetic field (PEMF) therapy can enhance the effects of anti-cancer chemotherapeutic agents. In this study, we investigated whether PEMFs influence the anti-cancer effects of etoposide in MCF-7 cells and determined the signal pathways affected by PEMFs. We observed that co-treatment with etoposide and PEMFs led to a decrease in viable cells compared with cells solely treated with etoposide. PEMFs elevated the etoposide-induced PARP cleavage and caspase-7/9 activation and enhanced the etoposide-induced down-regulation of survivin and up-regulation of Bax. PEMF also increased the etoposide-induced activation of DNA damage-related molecules. In addition, the reactive oxygen species (ROS) level was slightly elevated during etoposide treatment and significantly increased during co-treatment with etoposide and PEMF. Moreover, treatment with ROS scavenger restored the PEMF-induced decrease in cell viability in etoposide-treated MCF-7 cells. These results combined indicate that PEMFs enhance etoposide-induced cell death by increasing ROS induction-DNA damage-caspase-dependent apoptosis.

Comparison of EMG Activity of the Posterior Oblique Sling Muscles and Pelvic Rotation During Prone Hip Extension With and Without Lower Trapezius Pre-Activation

  • Jeon, In-cheol;Ha, Sung-min;Hwang, Ui-jae;Jung, Sung-hoon;Kim, Hyun-sook;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.23 no.1
    • /
    • pp.80-86
    • /
    • 2016
  • Background: Prone hip extension (PHE) can be performed to measure the lumbopelvic motor patterns and motions. Imbalances in lumbopelvic muscle activity and muscle weakness can result in instability including pain in lumbopelvic region. The posterior oblique sling (POS) muscles contribute to dynamic lumbopelvic stability. In addition, POS are anatomically aligned with the trapezius muscle group according to shoulder positions. Objects: This study compared the electromyography (EMG) activity of POS and pelvic compensations during PHE with and without pre-activation of lower trapezius muscle (lowT). Methods: Sixteen healthy males were recruited. PHE was performed in randomized order: PHE with and without lowT pre-activation. Surface EMG signals were recorded for biceps femoris (BF), gluteus maximus (GM) (ipsilateral), lumbar multifidus (MF) (bilateral), and the lowT (contralateral). An electromagnetic tracking motion analysis was used to measure the angle of pelvic rotation and anterior tilting. Results: The ipsilateral GM and bilateral MF EMG amplitudes were greater during PHE with lowT pre-activation compared to PHE without lowT pre-activation (p<.05). The BF amplitude during PHE without lowT pre-activation was significantly greater than that during PHE with lowT pre-activation (p<.05). The angles of pelvic rotation and anterior tilting during PHE with lowT pre-activation were significantly smaller compared to PHE without lowT pre-activation (p<.05). Conclusion: PHE with lowT pre-activation, which is aligned with the POS, showed more increased MF and GM muscular activity with smaller lumbopelvic compensations in rotation and anterior tilting compared to PHE without lowT pre-activation.

A Study of Tissue-equivalent Compensator for 10MV X-ray and Co-60 Gamma-ray (고에너지 방사선치료용 조직등가보상체에 관한 고찰)

  • CHOI Tae Jin;HONG Young Rak;LIM Charn Soo;JEUNG Ho Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.47-51
    • /
    • 1985
  • Authors describe some useful data when constructing tissue-equivalent compensators which would compensate tissue deficit in the treatment field of high energy electromagnetic radiation Tissue equivalent compensator is made of lucite. The ratio of compensator thickness to the thickness of tissue deficit depends on radiation energy, field size and the distance from the compensator to patient skin. When the compensator is separated from skin surface, the thickness ratio is always smaller than 1.0. This means that the larger the separation, the contribution to the total dose by means of scattered radiation from a tissue equivalent compensator is smaller. Authors propose that the thickness of lucite as tissue equivalent compensator is 0.57 times tissue deficit and the separation between compensator and skin is at least 15m for Co-60 gamma ray and 25cm for 10MV X-ray.

  • PDF

Treatment of Wallenberg's Syndrome Following Selective Nerve Root Block: A Case Report (요추부 선택적 신경근 차단술 이후 발생한 Wallenberg's Syndrome의 한방복합치료 1례)

  • Park, Seo-Hyun;Kwon, Jeong-Gook;Park, Jae-Won;Keum, Dong-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.26 no.4
    • /
    • pp.107-115
    • /
    • 2016
  • The occurrence of brain stem stroke after lumbar selective nerve root block seem to be an uncommon event comparing it to after cervical selective nerve root block. We recently experienced a 60-year-old man who were diagnosed as left lateral medullary infarction (Wallenberg's syndrome) after lumbar selective nerve root block. He was treated by traditional Korean medicine with acupunture, Pulsed electromagetic therapy (PEMT), herb medicine. The range of motion of upper and lower extremity, manual muscle test, Korean version of Berg balance scale (K-BBS) and Korean version of Barthel index (K-MBI) were adopted to measure the resulting recovery after 4 weeks treatment. Traditional Korean medicine was effective for rehabilitation of patient. Further studies are needed to set up and Korean medical protocol for Wallenberg's syndrome.

The design and Manufacture of Laser Induced Fluorescence Spectroscope Using the High Resolution Charge Coupled Device (고정밀 전하결합장치를 이용한 레이저유도 형광분광기의 설계 및 제작)

  • Kim, Ki-Jun;Lee, Hoo-Seol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.2
    • /
    • pp.129-133
    • /
    • 2005
  • It is very important to use the charge coupled devices (CCDs) in spectrometry because we can study the molecular energy level, molecular structure, absorption or emission, intermolecular reaction, weakly bound molecular energy, photochemistry, fluorescence and photodynamic therapy (PDT). CCD is very essential to study the molecular structure and medical engineering combining laser spectroscopy in the modem physicsal and chemistry. Therefore, this study has designed and manufactured the electromagnetic spectrometry with CCD and then analyzed the printed electronic circuit. In the yesterday, CCD was thought to be used in only broadcasting system. But nowadays, it is used by industrial demand in observations, instrumentations and robotics as the industry develop.

  • PDF