• Title/Summary/Keyword: Electromagnetic system

Search Result 2,923, Processing Time 0.029 seconds

Study for electromagnetic compatibility of electric train system (전기철도의 전자기적합성에 관한 고찰)

  • Kim Min-Cheol;Lee Jang-Mu;Han Moon-Soeb
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.883-888
    • /
    • 2005
  • In modern system, electromagnetic environment are going worse with advancing electric and electronic technology, and this electromagnetic environment affect modern electric train system at the point of the safety problem. Therefore, each distributed system that is consisting electric train system have to prove there own electromagnetic compatibility through the field test. These distributed system can be considered as power supply system, signal & communication system and train system. In this study, essential field tests for electromagnetic compatibility of train system based on IEC national standard are suggested.

  • PDF

Performance Analysis of the GPS Receiver System under Electromagnetic Test of the KSL V-I Upper-stage (KSLV-I 상단조립체의 전자파시험에서 GPS 수신기 시스템의 성능분석)

  • Moon, Ji-Hyeon;Kwon, Byung-Moon;Shin, Yong-Sul;Choi, Hyung-Don
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.161-169
    • /
    • 2008
  • This paper introduces test configuration and operation method for the GPS receiver system under electromagnetic test of KSLV-I upper-stage as a system qualification level and describes performance analysis of the test results. The GPS receiver system has clearly passed the electromagnetic test specifications of component level which is based on MIL-STD-461E through several design changes. Under electromagnetic test as a system qualification level, the GPS receiver system normally operates in spite of electromagnetic interferences with other systems. Performance of the GPS receiver system is also, not degraded on the condition of electromagnetic field incidence and electrostatic discharge. The KSLV-I GPS receiver system, as a result, is verified on the electromagnetic condition of the KSLV-I upper-stage.

  • PDF

Design and Analysis of An Electromagnetic System (전자기 시스템의 해석과 설계)

  • Park Seong-Wook;Kim Dong-Hun
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.1
    • /
    • pp.17-19
    • /
    • 2006
  • This paper presents the design of an electromagnetic system such as jumping ring system, and also considers the characteristics of dynamics for system with initial parameter. For the propose of system analysis, the MATLAB tool is to solve coupled differential equations with inductances and mutual inductance. To apply a real electromagnetic system, this paper implements the jumping ring system using design parameters, and analyzes the jumping ring system with proposal step.

Characteristics and Measurement Method of the Underwater Electromagnetic Signature Emitted from a Naval Ship (함정 발생 수중 전자기장 신호의 특성 및 측정 기법)

  • Yang, Chang-Seob;Chung, Hyun-Ju;Shin, Seung-Je
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.11-19
    • /
    • 2006
  • The underwater electromagnetic signatures of a naval ship are mainly generated from three sources which are the permanent and induced magnetic field in the ship's hull and other ferrous components, the cathodic current electromagnetic field established by the Impressed Current Cathodic Protection(ICCP) system or the Sacrificial Anode and the stray electromagnetic fields generated by onboard equipment. These signatures can be minimized by certain design methods or installation of signature reduction equipment. In this paper, we represented the characteristic of the underwater electromagnetic signature and the signature reduction techniques for a naval ship. Also, we measured the electromagnetic field changes emitted from the real ship using the Electric and Magnetic field Measurement System(EMMS). We found that the underwater electromagnetic signature for a naval ship can be used as input or trigger signal in a surveillance system and an influence mine.

3D Microwave Breast Imaging Based on Multistatic Radar Concept System

  • Simonov, Nikolai;Jeon, Soon-Ik;Son, Seong-Ho;Lee, Jong-Moon;Kim, Hyuk-Je
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.1
    • /
    • pp.107-114
    • /
    • 2012
  • Microwave imaging (MI) is one of the most promising and attractive new techniques for earlier breast cancer detection. Microwave tomography (MT) realizes configuration of a multistatic multiple-input multiple-output system and reconstructs dielectric properties of the breast by solving a nonlinear inversion scattering problem. In this paper, we describe ETRI 3D MT system with 3D MI reconstruction program and demonstrate its robustness through some examples of the image reconstruction.

Coil Gun Electromagnetic Launcher (EML) System with Multi-stage Electromagnetic Coils

  • Lee, Su-Jeong;Kim, Ji-Hun;Song, Bong Sob;Kim, Jin Ho
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.481-486
    • /
    • 2013
  • An electromagnetic launcher (EML) system accelerates and launches a projectile by converting electric energy into kinetic energy. There are two types of EML systems under development: the rail gun and the coil gun. A railgun comprises a pair of parallel conducting rails, along which a sliding armature is accelerated by the electromagnetic effects of a current that flows down one rail, into the armature and then back along the other rail, but the high mechanical friction between the projectile and the rail can damage the projectile. A coil gun launches the projectile by the attractive magnetic force of the electromagnetic coil. A higher projectile muzzle velocity needs multiple stages of electromagnetic coils, which makes the coil gun EML system longer. As a result, the installation cost of a coil gun EML system is very high due to the large installation site needed for the EML. We present a coil gun EML system that has a new structure and arrangement for multiple electromagnetic coils to reduce the length of the system. A mathematical model of the proposed coil gun EML system is developed in order to calculate the magnetic field and forces, and to simulate the muzzle velocity of a projectile by driving and switching the electric current into multiple stages of electromagnetic coils. Using the proposed design, the length of the coil gun EML system is shortened by 31% compared with a conventional coil gun system while satisfying a target projectile muzzle velocity of over 100 m/s.

A Study on the Electro-magnetic Wave of Inductive Power Transfer System for Light Railway Transit (경량전철용 유도급전 시스템의 전자파 분석 연구)

  • Park, Chan-Bae;Lee, Byung-Song;Lee, Hyung-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1210-1215
    • /
    • 2012
  • Traction motors for driving and power conversion devices using semiconductor switch are equipped with a transportation systems such as an electrical railway system. Power conversion devices have the possibility of malfunction by external electromagnetic waves. As a result, these could affect the safe operation of the railway. Moreover, the electromagnetic waves above safe limits will be harmful to the passengers inside the railway vehicles or anyone working around the rail-track. For this reason, the importance and need about the reliability check and complement of electromagnetic waves generated from the IPT(Inductive Power Transfer) system have been suggested for the safe application of the IPT system to the railway system. In this study, prediction for the electromagnetic wave properties was conducted through FEM(Finite Element Method) analysis of 5kW-class IPT system design model. Next, the 5kW IPT system prototype was made and then the small-scaled railway vehicle was made to mount the IPT system and the energy management system. Finally, the electromagnetic waves generated from the real small-scaled IPT system were measured and analyzed, and then the reliability check of predictions by FEM analysis were carried out.

Electromagnetic Test of the GPS Receiver System for a Satellite Launch Vehicle - Part I. Outline & Emission Test (위성발사체용 GPS 수신기 시스템의 전자파시험 - Part I. 시험개요 및 방사시험)

  • Kwon, Byung-Moon;Moon, Ji-Hyeon;Choi, Hyung-Don;Cho, Gwang-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.329-337
    • /
    • 2007
  • This paper deals with electromagnetic tests of the GPS receiver system that should be developed to satisfy emission and susceptibility requirements for a satellite launch vehicle. Performance of the GPS receiver system against electromagnetic environment that is improved through several tests satisfies all requirements about electromagnetic tests. The outline of the electromagnetic tests and emission test results of CE102, CE106 and RE102 on MIL-STD-461E are described in Part I.

Design and Analysis of Electromagnetic System (자기 시스템의 해석과 설계)

  • Park, S.W.;Oh, J.H.;Yoon, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.520-522
    • /
    • 2005
  • This paper presents the design and analysis of the electromagnetic system such as jumping ring system. Also, we study the characteristics of dynamics for system with initial parameter. For the propose of system control,, first, we simulate the MATLAB tool solving coupled differential equations with electric parameter, inductance and mutual inductances. Therefore, we design a jumping ring system using design results, implement, and analyze the jumping ring system real situation. For the near time, we present a control process, and compare of real system and software technique.

  • PDF

Design and Evaluation of Pulsed Electromagnetic Field Stimulation Parameter Variable System for Cell and Animal Models (세포 및 동물모델용 펄스형 전자기장 자극 파라미터 가변장치 설계 및 평가)

  • Lee, Jawoo;Park, Changsoon;Kim, Junyoung;Lee, Yongheum
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.11-18
    • /
    • 2022
  • An electromagnetic generator with variable stimulation parameters is required to conduct basic research on magnetic flux density and frequency for pulsed electromagnetic fields (PEMFs). In this study, we design an electromagnetic generator that can conduct basic research by providing parameters optimized for cell and animal experimental conditions through adjustable stimulation parameters. The magnetic core was selected as a solenoid capable of uniform and stable electromagnetic stimulation. The solenoid was designed in consideration of the experimental mouse and cell culture dish insertion. A voltage and current adjustable power supply for variable magnetic flux density was designed. The system was designed to be adjustable in frequency and pulse width and to enable 3-channel output. The reliability of the system and solenoid was evaluated through magnetic flux density, frequency, and pulse width measurements. The measured magnetic flux density was expressed as an image and qualitatively observed. Based on the acquired image, the stimulation area according to the magnetic flux density decrease rate was extracted. The PEMF frequency and pulse width error rates were presented as mean ± SD, and were confirmed to be 0.0928 ± 0.0934% and 0.529 ± 0.527%, respectively. The magnetic flux density decreased as the distance from the center of the solenoid increased, and decreased sharply from 60 mm or more. The length of the magnetic stimulation area according to the degree of magnetic flux density decrease was obtained through the magnetic flux density image. A PEMF generator and stimulation parameter control system suitable for cell and animal models were designed, and system reliability was evaluated.