• Title/Summary/Keyword: Electromagnetic Field

Search Result 1,869, Processing Time 0.025 seconds

Field Distribution Characteristics of A Reverberation Chamber with Different Conditions of Diffuser Arrangement (전자파 진향실 내 확산기 배열 조건에 따른 필드분포 특성)

  • 이광순;이중근;정삼영
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.2
    • /
    • pp.227-233
    • /
    • 2001
  • Electromagnetic field characteristics of Reverberation chamber, which could be applicable for an alternative test facility of electromagnetic interference and radiated electromagnetic susceptibility have been investigated. To obtain the required field uniformity of reverberation chamber, Schroeder method Quadratic Residue Diffuser was designed to be applied to chamber. In this paper, 3 different types of diffusers depending on diffuser's periodic direction have been used to investigate field characteristics of each type by using FDTD numerical method. The results show all 3 types of reverberation chambers have below $\pm$3 dB tolerance of field uniformity characteristics, and the symmetrical, type 3, structure show better results among them.

  • PDF

전자기 성형에서의 테이퍼진 지속집중기의 자기압력에 관한 연구

  • Choe, Jae-Chan;Jo, Yong-Cheol;Lee, Jong-Su;Hwang, Un-Seok;Kim, Nam-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.7 no.2
    • /
    • pp.14-27
    • /
    • 1990
  • Electromagnetic Pulse Forming is the one of the high velocity forming method. When the electric energy which is charged in the capacitor bank is suddenly discharged into the electromagnetic coil, the high magnetic field occurs at the airgap between the electromagnetic coil and workpiece. Thus we can obtain the high electromagnetic pressure, which is proportional to the square of magnetic flux density. This is the basic principle of the electromagnetic pulse forming. In this paper, the equivalent L-R-C circuit is derived by computing the magnetic field and its loss of the total system. Thus, the values of the magnetic flux density and pressure can be obtained from the equation of this circuit. As a result, the computed and measured values of the maximum magnetic flux density and pressure are compared and the characteristics of the tapered field shaper are further discussed as follows; 1) The strength of magnetic flux density and pressure can be controlled by the charged energy and the size of the airgap between the inner field shaper and the workpiece. 2) During the design of the tapered field shaper, the penetration of the magnetic flux through the sharp edge should be considered.

  • PDF

The Measurement of Electromagnetic Wave in Power Cable Tunnel of Underground Utility Tunnel (전력구 내 전자기파에 대한 작업 환경 측정)

  • Kang, Dae Kon;Park, Jai Hak
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Electromagnetic measurements of the power cable tunnel were conducted from August 10 to 20, 2018, in the ${\bigcirc}{\bigcirc}$ city underground utility tunnel. During this period, the average temperature was $31.89^{\circ}C$ and the humidity was 67.56% in power cable tunnel. As a result of the electromagnetic measurement, the highest electric field was 25.3 V/m and the magnetic flux density was $42.6{\mu}T$. The average electric field was 18.56 V/m and the magnetic flux density was $29.32{\mu}T$ in the power cable tunnel. As a result of comparison with the electric equipment technical standard, the electric field in the power cable tunnel was 0.5% of the electric equipment standard and 35.2% of the magnetic flux density. It's similar value that electric field is about robotic vacuum(15.53 V/m), and magnetic flux density is similar value about capsule- type coffee machine ($23.07{\mu}T$). The number of cable lines and the size of the electromagnetic waves were not proportional to each other through comparison of cable lines in the power cable tunnel. It was confirmed that 154 kV, rather than 22.9 kV, could have a greater influence on occupational.

The study of emissive electromagnetic interference DMT PLC(Power Line Communication) (DMT 방식 전력선 통신의 전자파 장애에 관한 연구)

  • Choi, Jong-Pil;Shin, Chull-Chai
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.604-608
    • /
    • 2003
  • In this paper, we studied the radiated electric field of power-line with DMT signal source in the frequency range of $1.7{\sim}30 MHz$. First, we made the midium voltage power-line communication model for PLC and calculated the current through the power-line using the impedance of the power-line model. Second, we calculated the radiated electric field in power range $-50{\sim}-30 dBm$ using the calculated current. Consequently, the calculated emissive electromagnetic field from the DMT signal is similar to the measured result. So this study is applicable to the standard regulation of electromagnetic interference for PLC.

  • PDF

A Study for the Measurement Method of Electromagnetic Field Strength of Power Line Communications Modem (전력선통신모뎀의 전자계강도 측정방법 연구)

  • Jang Dong-Won
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.162-165
    • /
    • 2006
  • This paper describes a measurement method for electromagnetic field strength of power-line communications(PLC) modem. First it outlines the technology used in PLC modems, and the technical regulation being offered to the technology, from the point of view of its effect on electromagnetic compatibility (EMC). The radio spectrum needs protection from other interferers, and there is a regime in place to provide this protection. Difficulties in achieving compatibility between the requirements for radio protection and the requirements for operation of the PLC modem mean that there is no consensus as yet as to how PLC modem components can be made compliant with EMC requirements globally. It is concluded that there is a measurement method according to CISPR standards which satisfy requirements in domestic regulation.

  • PDF

EDUCATION OF ELECTROMAGNETIC PENETRATION THROUGH NARROW SLOTS IN CONDUCTING SCREEN BY PARALLEL PLATE LOADING (평행평판 장하에 의한 슬릿 침투 전자파의 저감 특성)

  • Park, Eun-Jung;Ju, Chang-Hyun;Kim, Ki-Chai
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.66-68
    • /
    • 2005
  • This paper presents the reduction characteristics of penetrated electromagnetic fields through a narrow slot aperture in a planar conducting screen of infinite extent. When a plane wave is excited to the narrow slot, the aperture electric field is controlled by the parallel plate connected on the slot. The magnitude of penetrated electromagnetic fields through a narrow slot is controlled by electric field distributions on the slot aperture. An integral equation for the aperture electric field on narrow slots is derived and solved by applying Galerkin's method of moments. The results show that the magnitude of the penetrated electromagnetic field can be effectively reduced by installing the parallel plate on the slot aperture.

  • PDF

A Study of Coupled Electromagnetic-Thermal Field Analysis for Temperature Rise Prediction of Power Transformer (전력용 변압기의 온도상승 예측을 위한 전자계-열계 결합해석기법 연구)

  • Ahn, Hyun-Mo;Kim, Min-Soo;Song, Jae-Sung;Hahn, Sung-Chin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1838-1845
    • /
    • 2011
  • This paper deals with coupled electromagnetic-thermal field analysis for thermal fluid analysis of oil immersed power transformer. Electric power losses are calculated from electromagnetic field analysis and are used as input source of thermal field analysis based on computational fluid dynamics(CFD). Particularly, In order to accurately predict the temperature rise in oil immersed power transformer, the thermal problem should be coupled with the electromagnetic problem. Moreover, to reduce analysis region, the heat transfer coefficient is applied to boundary surface of the power transformer model. The coupling method results are compared with the experimental values for verifying the validity of the analysis. The predicted temperature rises show good agreements with the experimental values.

Development of the Electromagnetic Field Water Treater System (전자장 수처리 시스템 개발)

  • Kim, Sang-Uk;Kim, Jin-Hwan;Kim, Bo-Youl;Kim, Young-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.142-145
    • /
    • 2002
  • This paper presents the electromagnetic field water treater system with the high performance for a good quality of water. The electromagnetic field water treater consists of a solion, a solion body. and a high voltage converter. The high voltage converter is controlled by PWM current controller. The high voltage converter of 13W is designed for an isolation operation ramp. an isolation current detector, and an over current protector. Using the high voltage PWM converter, the system with the proposed electromagnetic field water treater can be controlled easily. Simulation and experimental results show the effectiveness of the system strategy proposed for the scale rejection.

  • PDF

The Characteristic of Electric Field Penetration into Infinite Conducting Plane with an Aperture Due to HEMP Incidence (HEMP 파원에 의한 무한 도체 평판 개구의 침투 전계 특성)

  • Lim, Byoung-Jin;Jung, Sung-Woo;Cho, Byung-Doo;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1454-1459
    • /
    • 2010
  • This paper presents the comparison of electric field penetration in Bell laboratories and IEC 61000-2-9 standard when HEMP source penetrates through an aperture in a planar conducting plane of infinite extent. HEMP electric field distributions assume in order to interpret this problem. Integral equation is derived and solved by Galerkin's method of moments for calculating the penetrating electric field. It is shown that penetrated electric field of IEC 61000-2-9 standard is greater than the Bell Laboratories waveform in resonance of lower frequency band, but those waveforms are similar in shape to frequency domain.

Numerical Simulation of Thin Sheet Metal Forming Process using Electromagnetic Force (전자기력을 이용한 박판 성형공정의 해석적 연구)

  • Seo, Y.H.;Heo, S.C.;Ku, T.W.;Song, W.J.;Kang, B.S.;Kim, J.
    • Transactions of Materials Processing
    • /
    • v.17 no.1
    • /
    • pp.35-45
    • /
    • 2008
  • Electromagnetic Forming (EMF) technology such as magnetic pulse forming, which is one of the high velocity forming methods, has been used for the joining and forming process in various industry fields. This method could be derived a series of deformation of sheet metal by using a strong magnetic field. In this study, numerical approach by finite element simulation of the electromagnetic forming process was presented. A transient electromagnetic finite element code was used to obtain the numerical model of the time-varying currents that are discharged through the coil in order to obtain the transient magnetic forces. Also, the body forces generated in electromagnetic field were used as the loading condition to analyze deformation of thin sheet metal workpiece using explicit dynamic finite element code. In this study, after finite element analysis for thin sheet metal forming process with free surface configuration was performed, analytical approach for a dimpled shape by using EMF was carried out. Furthermore, the simulated results of the dimpled shape by EMF were compared with that by a conventional solid tool in view of the deformed shape. From the results of finite element analysis, it is confirmed that the EMF process could be applied to thin sheet metal forming.